Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,514 records · Page 85

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

The Global Spectra-Trait Initiative: A database of paired leaf spectroscopy and functional traits associated with leaf photosynthetic capacity (v1.0.0)

The Global Spectra-Trait Initiative (GSTI) aims to generate generalizable spectra trait models using reflectance data to predict leaf traits associated with the photosynthesis capacity of leaves. It comprises a synthesized dataset of leaf trait data, input datasets and code. Leaf traits include the maximum carboxylation rate of rubisco (Vcmax), the maximum electron transport rate (Jmax), the dark respiration, as well as the prediction of leaf nitrogen, leaf mass per area (LMA), and leaf water content (LWC). The dataset comprises >7500 paired observations from around 400 species from a broad range of biomes. This dataset comprises a zip file of the GSTI GitHub repository (https://github.com/plantphys/gsti), the synthesized database (.csv) and database metadata files. This dataset was updated on 2025-12-12 with minor edits to mirror the accepted manuscript version and GitHub release (Version 1.0.0 (ESSD accepted version)). Edits included minor changes to the project documentation on GitHub and removal of 12 duplicate entries from the database.

54 ENVIRONMENTAL SCIENCES↗