Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

the Cryogenic Underground Observatory for Rare Events: Status and Prospects

The Cryogenic Underground Observatory for Rare Events (CUORE) is a large-scale double beta decay experiment utilizing cryogenic bolometers that is currently being commissioned at the Gran Sasso National Laboratory (LNGS) in Italy. Its primary focus is to search for the neutrinoless double beta decay of 130Te with a projected sensitivity to Majorana neutrino masses near the inverted mass hierarchy region. The detector is composed of 988 5x5x5-cm 3 TeO 2 crystals of natural isotopic composition arranged in 19 towers of 52 crystals each, all housed in a common dilution refrigerator. A single CUORE-like tower, CUORE-0, was assembled and operated as a stand-alone detector for a period of approximately two years. In this report, the results from CUORE-0 and the current status and physics potential of CUORE are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermal conductance modeling and characterization of the SuperCDMS-SNOLAB sub-Kelvin cryogenic system

The detectors of the Super Cryogenic Dark Matter Search experiment at SNOLAB (SuperCDMS SNOLAB) will operate in a seven-layered cryostat with thermal stages between room temperature and the base temperature of 15 mK. The inner three layers of the cryostat, which are to be nominally maintained at 1 K, 250 mK, and 15 mK, will be cooled by a dilution refrigerator via conduction through long copper stems. Bolted and mechanically pressed contacts, at and cylindrical, as well as exible straps are the essential stem components that will facilitate assembly/dismantling of the cryostat. These will also allow for thermal contractions/movements during cooldown of the sub-Kelvin system. To ensure that these components and their contacts meet their design thermal conductance, prototypes were fabricated and cryogenically tested. The present paper gives an overview of the SuperCDMS SNOLAB sub-Kelvin architecture and its conductance requirements. Results from the conductance measurements tests and from sub-Kelvin thermal modeling are discussed.

43 PARTICLE ACCELERATORS↗

Cryogenic pressurized storage with hump-reinforced vacuum jacket

A cryogenic hydrogen storage vessel includes an outer vacuum vessel, a reinforcement ring on the outer vacuum vessel, an inner pressure vessel inside of the outer vacuum vessel, and a vacuum space between the outer vacuum vessel and the inner pressure vessel. One embodiment of the cryogenic hydrogen storage vessel includes an outer vacuum vessel; a hump-shaped reinforcement ring on the outer vacuum vessel, the hump-shaped reinforcement ring including an external hump portion that protrudes from the hump-shaped reinforcement ring and an internal recess in the hump-shaped reinforcement ring; an inner pressure vessel inside of the outer vacuum vessel, a vacuum space between the outer vacuum vessel and the inner pressure vessel, and a composite support ring in the vacuum space extending from the hump-shaped reinforcement ring on the outer vacuum vessel to the inner pressure vessel, the composite support ring nested in the recess in the hump-shaped reinforcement ring.

Aceves, Salvador M.↗

Ortho-H2 refueling for extended cryogenic pressure vessel dormancy

A cryogenic hydrogen storage system reduces hydrogen loss by providing an initial supply of hydrogen wherein the initial hydrogen has an initial para/ortho hydrogen ratio. The initial hydrogen having an initial para/ortho hydrogen ratio is adjusted to produce final hydrogen having a final para/ortho hydrogen ratio with a greater amount of ortho hydrogen, The cryogenic hydrogen storage system is refueled with the final hydrogen having a final para/ortho hydrogen ratio with a greater amount of ortho hydrogen.

08 HYDROGEN↗

Cryogenic pressurized storage with hump-reinforced vacuum jacket

A cryogenic hydrogen storage vessel includes an outer vacuum vessel, a reinforcement ring on the outer vacuum vessel, an inner pressure vessel inside of the outer vacuum vessel, and a vacuum space between the outer vacuum vessel and the inner pressure vessel. One embodiment of the cryogenic hydrogen storage vessel includes an outer vacuum vessel; a hump-shaped reinforcement ring on the outer vacuum vessel, the hump-shaped reinforcement ring including an external hump portion that protrudes from the hump-shaped reinforcement ring and an internal recess in the hump-shaped reinforcement ring; an inner pressure vessel inside of the outer vacuum vessel, a vacuum space between the outer vacuum vessel and the inner pressure vessel, and a composite support ring in the vacuum space extending from the hump-shaped reinforcement ring on the outer vacuum vessel to the inner pressure vessel, the composite support ring nested in the recess in the hump-shaped reinforcement ring.

Aceves, Salvador M.↗

An upgraded cryogenic test stand for HL-LHC cryo-assemblies

The Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles has been upgraded to test cryo-assemblies for the high-luminosity LHC upgrade (HL-LHC). The test requirements of these new cryo-assemblies required additional capabilities of the test stand cryogenic system, including controlled cool-down and warm-up, helium recovery after a quench, and operation at higher pressures. Most of these upgrades were completed to support a zero-magnet test in late 2020, with the remainder of the upgrades completed to support the first pre-series cryo-assembly test in early 2022. An overview of the design and initial operating experience of the upgraded test stand cryogenic system and associated process controls system are presented in this paper.

Rabehl, Roger J.↗

Vacuum manufacture of cryogenic pressure vessels for hydrogen storage

In one aspect the present disclosure relates to a method of manufacturing a cryogenic pressure vessel. The method may include providing a metal lined, composite wrapped vessel which has a boss. The method may further include securing an inlet to the boss, and then encapsulating the metal lined, composite wrapped vessel within a metallic layer in a vacuum controlled environment to form an encapsulated inner tank subassembly. The method may further include securing at least one support to an exterior of the encapsulated inner tank subassembly, and within the controlled vacuum environment, applying a metal coating over the encapsulated inner tank subassembly and the at least one support to form a metal coated, encapsulated inner tank subassembly. The method may further include, within the controlled vacuum environment, encapsulating the metal coated, encapsulated inner tank subassembly within a metallic vacuum jacket, which forms the cryogenic pressure vessel.

Aceves, Salvador M.↗

Effective Field Theory Analysis and Active Neutron Veto Design for the Cryogenic Dark Matter Search

Astrophysical measurements and cosmological predictions suggest the exists of a large amount of matter in the universe that does not interact via electromagnetic forces. This non-luminescent matter, known dark matter, exists in halos that encompass and are within galaxies, including the Milky Way. Therefore, dark matter particles should should be directly detectable by experiments on Earth, such as the Super Cryogenic Dark Matter Search (SuperCDMS). Dark matter is assumed to be low mass (< 100 GeV/c2) and interact via the weak force using either a spin-independent or spin-dependent coupling. However, making incorrect assumptions about dark matter interactions can lead to misleading results. Because interactions with dark matter particles are rare, direct detection experiments must be able to shield for or reject backgrounds to very low levels. Low energy neutron backgrounds that make it to the detectors are especially dangerous, because they cannot be easily distinguished from the expected dark matter signal. Scintillator doped with a high neutron-capture cross-section material can be used to detect neutrons via their resulting gamma rays. Examples of such detectors using liquid scintillator have been successfully used in past high-energy physics (HEP) experiments. However, a liquid scintillator can leak and is not as amenable to modular or complex shapes as a solid scintillator. The light outputs and efficiencies of gadolinium-loaded polystyrene-based scintillators have been explored using a wide variety of gadolinium compounds with varying concentrations. Collection strategies using a wavelength shift- ing (WLS) fiber and silicon photomultipliers (SiPMs) were also evaluated as a possible neutron veto for an upgrade to SuperCDMS SNOLAB. The scattering of dark matter particles off nuclei in direct detection experiments can be described in terms of a multidimensional effective field theory (EFT). A new systematic analysis technique is developed using the EFT approach and Bayesian inference methods to exploit, when possible, the energy-dependent information of the detected events, experimental efficiencies, and backgrounds. Highly dimensional likelihoods are calculated over the mass of the weakly interacting massive particle (WIMP) and multiple EFT coupling coefficients, which can then be used to set limits on these parameters and choose models (EFT operators) that best fit the direct detection data. Expanding the parameter space beyond the standard spin-independent isoscalar cross section and WIMP mass reduces tensions between previously published experiments. Combining these experiments to form a single joint likelihood leads to stronger limits than when each experiment is considered on its own. Simulations using two nonstandard operators (O3 and O8) are used to test the proposed analysis technique in up to five dimensions and demonstrate the importance of using multiple likelihood projections when determining constraints on WIMP mass and EFT coupling coefficients. In particular, this shows that an explicit momentum dependence in dark matter scattering can be identified. CDMSlite Run 2 was a search for Weakly Interacting Massive Particles (WIMPs) with a cryogenic 600 g Germanium detector operated deep underground. It was operated in a mode optimizing sensitivity to WIMPs of relatively low mass, 2 - 20 GeV, while sacrificing background rejection. An EFT analysis of CDMSlite Run 2 data from SuperCDMS Soudan is presented here. A binned likelihood Bayesian analysis was performed on the data, optimizing over the parameters of EFT interactions and the recoil energy spectra due to the dominant Compton scattering and tritium backgrounds. Recoil energy regions within 5σ of known activation peaks were removed from the analysis. The Bayesian evidences of the resulting likelihoods show that CDMSlite Run 2 data is entirely consistent with the background models with no EFT interaction necessary. Upper limits on the WIMP mass and coupling coefficients amplitudes and phases are presented for each EFT operator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Cryogenic Control System for the Vertical Test Area at Jefferson Lab

The Vertical Test Area at Jefferson Lab, consisting of eight vertical dewars, recently received a major upgrade by replacing the original (1995) cryogenic control system. A new, state-of-the-art, distributed control system (DC S) based on Programmable Logic Controllers (PLCs) was installed and commissioned. The new system increases facility throughput, reliability and cryogenic efficiency, while improving safety. The system employs a touchscreen graphical user interface and a highly redundant architecture on an Ethernet backbone.

Davis, K.↗

Precooling system utilizing cryogenic liquid fuels for fueling pressurized vehicle gaseous onboard storage tank system with controlled dispensing temperatures

A method and a precooling system are provided for precooling gaseous fuel supplied for fueling pressurized gaseous vehicle onboard storage tank systems. The precooling system is used in pressurized gaseous fueling stations with source fuels in cryogenic state, such as liquid hydrogen (LH2) and liquefied nature gas (LNG). A thermal buffer heat exchanger includes a heat exchanger medium, and a cold loop and a warm loop contained in the heat exchanger medium. A control unit is configured for controlling cryogenic fuel supplied to the cold loop for cooling the thermal buffer heat exchanger. The thermal buffer heat exchanger enables precooling high pressure gaseous fuel to a preset temperature supplied to a dispenser supplying high pressure gaseous fuel to refuel a vehicle onboard storage tank system.

Elgowainy, Amgad A.↗

Cryogenic testing of the first HL-LHC Q1/Q3 cryo-assembly at Fermilab

In early 2023, Fermilab is conducting horizontal cryogenic testing of the first Q1/Q3 cryo-assembly for the high-luminosity LHC upgrade (HL-LHC). The cryo-assembly was installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of this test include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressure up to 18 bar with full helium recovery after a quench. This paper presents the operational experience gained from this first test.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Fermilab SSR1 and HB650 Synoptic and EPICS remote cryogenic control system

The 325MHz Single Spoke Resonator 1 (SSR1) Cryomodule (CM) has a 5.3-meter length, and it has 288-liter liquid helium @ 4.5K mode. The High Beta 650 MHz (HB650) CM contains six elliptical cavity cryomodules, has a 9.9-meter overall length and it has 530-liter liquid helium. The SSR1 and HB650 CM had been tested at Fermilab Cryomodule Test Facility (CMTF). Their cryogenic control system includes the Siemens Process Control System S7-400, Automation Direct DL205 PLC, and remote synoptic HMI/EPICS Phoebus GUI. This paper presents a method which has been successfully used by Fermilab PIP2 IT cryogenic remote on-line, real-time control systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monitoring Helium Cryogen Usage with iFix Software at IB1 Test Facility

At the IB1 facility of the Applied Physics and Superconducting Technology Directorate within the Cryogenic Division at Fermilab, Liquid Helium is essential to the testing activities. The test stands require large amounts of Helium to test the thermal and superconducting cavities and magnets. The Liquid Helium that enters the test stand is monitored through a series of valves and controls to determine the start and stop for monitoring time. There are 3 phases of cryogen usage that must be considered for each stand, cooldown, warming and overnight mode. With a new system in place, cold hour tracking will be more objective and precise within each test stand ensuring better calculations for User s fees which are charged to various groups that employ the facility and aid replenishment of Helium and continual operation at IB1.

Trillo, Angelica↗

PIP-II Linac Cryogenic Distribution System Design Challenges

The PIP-II linac Cryogenic Distribution System (CDS) is characterized by extremely small heat inflows and robust mechanical design. It consists of a Distribution Valve Box (DVB), Intermediate Transfer Line, Tunnel Transfer Line, comprising 25 Bayonet Cans, and ends with a Turnaround Can. Multiple helium streams, each characterized by distinct helium parameters, flow through each of these elements. The CDS geometry allows maintaining an acceptable pressure drop for each helium stream, considering the planned flows and helium parameters in different operation modes. This is particularly crucial for the return line of helium vapors, which return from cryomodules to the cold compressors and thus have very restrictive pressure drop requirements. On both sides of the DVB there are fixed supports for process pipes. One of the DVB design challenges was to route the process pipes in such a way that their shape provided sufficient compensation for thermal shrinkage. This ensures th at the forces resulting from thermal shrinkage acting on the cryogenic valves remain at a level acceptable to the manufacturer. The required thermal budget of the CDS was achieved by thermo-mechanical optimization of its components, like process pipes fixed supports in Bayonet Cans.

43 PARTICLE ACCELERATORS↗

Cryogenic testing of HL-LHC Q1/Q3 cryo-assemblies at Fermilab

Fermilab is conducting horizontal cryogenic testing of Q1/Q3 cryo-assemblies for the high-luminosity LHC upgrade (HL-LHC). Cryo-assemblies are installed on the upgraded Fermilab horizontal test stand previously used for testing the LHC inner triplet quadrupoles. The cryogenic process requirements of these tests include controlled cool-down and warm-up with a 100 K maximum temperature differential between the two ends of the cold mass, operation of a 1.3 bar, 1.9 K bath of subcooled superfluid helium during power testing and magnetic measurements, and operation at pressure up to 18 bar with full helium recovery after a quench. This paper presents the operational experience gained from the first tests as well as improvement for subsequent tests.

Rabehl, R. [Fermilab] (ORCID:0000000311130030)↗

Cryogenic Gear System for ADMX Tuning Cavity

The Axion Dark Matter Experiment (ADMX) searches for axions by converting them into detectable photons using resonant microwave cavities at cryogenic temperatures. A precise tuning system is needed to adjust cavity frequency without adding thermal load or electromagnetic interference. This project developed and tested a 1000 to 1 gear reduction system made from PEEK, a low thermal conductivity plastic with good dimensional stability and self lubrication at low temperatures. A compound gear train design of five 3 to 1 stages and one 4 to 1 stage achieves high reduction within a 40 mm diameter compact housing. Prototypes were 3D printed and later CNC machined in PEEK using Fusion 360 and Bantam Tools to confirm manufacturability. Prototype testing showed smooth gear engagement and no slipping. The final gearbox improves cavity tuning precision for axion searches while protecting cryogenic conditions.

Ortega, Giancarlo [Marquette U.]↗

Fermilab PIP-II CDS and CM Cryogenic Controls System

Details on Final design for Cryogenic Electrical & Controls System for Fermilab' s next-gen particle accelerator PIP-II. Electrical Controls System includes instrumentation and controls of Cryogenics Distribution System and Cryomodules. Design includes Siemens PCS7 Controls System with 26 Remote IO Rittal Cabinets and 48 Relay Racks for Temperature Readouts, Valve Positioners, Level, Heater Controls etc. Electrical Drawings and Design have been completed with focus now on fabrication of the 26 Rittal Cabinets and 48 Relay Racks. All materials have been procured. EPICS will be used as a SCADA system communicating to S7 Controllers via OPC UA.

Patel, Pratik [Fermilab]↗

Experimental and Computational Study of Weld Drop-Through Hydraulic Effects in Multi-Layer Concentric Pipes Servicing Cryogenic Liquid Hydrogen

The Cryogenic Moderator System (CMS) at the Oak Ridge National Laboratory (ORNL)-Spallation Neutron Source (SNS) supplies liquid hydrogen, through vacuum insulated transfer lines to the moderators. The welding process used to make the transfer lines produces weld drop-through, which can constrict the flow of hydrogen and/or cause thermal bridges between adjacent layers. To ensure proper operation of the CMS it is therefore necessary to conduct a flow test to verify the pressure drop caused by the welds. Measurements in as-built piping sections intended to provide liquid hydrogen service to the SNS-CMS system were performed to test the effect of weld penetrations into the fluid flow area focusing on pressure drop effects. The reference test sections were designed using prototypical piping dimensions, materials and expected penetration welds. A numerical study using Computational Fluid Dynamics (CFD) tools in the transfer lines provided a conversion factor from the pressure drop measured in the lines with water to the expected pressure drop using liquid cryogenic hydrogen. The results show evidence of a maximum pressure drop modification in water of 78 KPa in the tested parts, which scales to liquid hydrogen as PHydrogen = 5.2 KPa. The maximum measured equivalent blockage area percentage was found in the as-built TDM transfer line spool 2 with a value of 31%. The measured values obtained in the as-built transfer lines provided accurate values to estimate the expected total pressure drop in the CMS system providing operational limits for the current recirculatory capacity. The effect of the weld drop-through in hydrogen evacuation capacity scenarios was better evaluated as a result of this study.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗