Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Effects of Controlled Cooling-Induced Ferrite–Pearlite Microstructure on the Cold Forgeability of XC45 Steel

The combination of hot/warm and cold forging with an intermediate controlled cooling process is a promising approach to saving costs in the manufacture of automobile parts. In this work, the effects of the ferrite–pearlite microstructure, which formed after controlled cooling, on the cold forgeability of a medium-carbon steel were investigated. Different specimens for both normal and notched tensile tests were directly heated to high temperature and then cooled down at different cooling rates, producing different ferrite volume fractions, ranging from 6.69 to 40.53%, in the ferrite–pearlite microstructure. The yield strength, ultimate tensile strength, elongation rate, percentage reduction of area, and fracture strain were measured by tensile testing. The yield strength, indicating deformation resistance, and fracture strain, indicating formability, were used to evaluate the cold forgeability. As the ferrite volume fraction increased, the cold forgeability of the dual-phase ferritic–pearlitic steel improved. A quantitatively relationship between the ferrite volume fraction and the evaluation indexes of cold forgeability for XC45 steel was obtained from the test data. To validate the mathematical relationship, different tensile specimens machined from real hot-forged workpieces were tested. There was good agreement between the predicted and measured values. Our predictions from the relationship for cold forgeability had an absolute error less than 5%, which is acceptable for industrial applications and will help to guide the design of combined forging processes.

36 MATERIALS SCIENCE↗

Ionic liquid-based hybrid absorption cycle for water heating, dehumidification, and cooling

Water heating, dehumidification and space cooling are responsible for significant energy consumption in buildings. A potential energy saving measure is to develop hybrid systems that can utilize the sensible and latent heats removed in space cooling to heat water. In this paper, we present experimental results on a hybrid system that utilizes the latent heat released in the dehumidification process for water heating. This system absorbs water vapor from the air and transfers the heat of phase change into the process water. The absorbed water vapor is then liberated in a desorber and subsequently condensed in a condenser, while its latent heat is transferred to the process water. The condensed water vapor can then be either drained (if dehumidification is desired), or utilized in an evaporative cooling process (if sensible space cooling is desired). In essence, the system can exchange both sensible and latent heats with its ambient. The main innovations implemented in the system are (1) a semi-open absorption system architecture to lower the system cost, (2) a membrane-based absorber to alleviate the liquid entrainment issue encountered in the conventional packed bed absorbers and (3) an ionic liquid that eliminates the crystallization risks and minimizes corrosion issues normally associated with LiBr-based absorption systems. Furthermore, a water heating thermal COP of 1.4 is achieved at 30°C, 70% RH ambient conditions.

42 ENGINEERING↗

Design optimization of integrated cooling inserts in modular Fischer-Tropsch reactors

Sustainable production of liquid fuels and feedstocks from atmospheric CO 2 through carbon recycling technologies is necessary to broaden decarbonization efforts and further reduce global emissions. Fischer–Tropsch (FT) reactors can address this challenge by providing storable, high-value liquid hydrocarbon fuels and feedstocks from syngas generated through reductive CO 2 utilization. FT technology, however, is most cost effective at large-scale, fixed-site plants and does not effectively address the smaller, globally distributed CO 2 point sources. Alternatively, smaller, modular reactors can be composed together to the specific scale of the emission source, yielding a flexible solution that enables more widespread deployment. In these modular reactors, thermal management using a finned cooling insert embedded within the catalyst matrix is critical to maintaining the performance and viability. Thus, in this work, topology optimization is used to determine the cooling insert geometry that maximizes reactor productivity while preventing auto-thermal runaway. Optimal designs are generated for varying number of constituent fins and over a range of maximum operating temperatures. Constraints including minimum feature length-scales and prescribed cooling insert material are imposed on the designs to enhance manufacturability. The impact of design features such as insert tapering and increased length scale hierarchy is automatically revealed by the systematic design framework employed. Here, this approach thus generates novel optimal geometries while automating, accelerating, and enhancing the design process compared to traditional heuristic approaches for cooling insert design in modular FT reactors.

30 DIRECT ENERGY CONVERSION↗

Utilization of waste heat from a commercial GT for freshwater production, cooling and additional power: Exergoeconomic analysis and optimization

In this work, a multigeneration system is proposed for power, cooling and freshwater production. The waste heat from a SIEMENS SGT6-2000E GT is utilized to drive a supercritical CO 2 recompression Brayton cycle (SCRBC) and multi-effect desalination (MED) with thermal vapor compressor (TVC), while the waste heat from the pre-cooler of the SCRBC is utilized to drive an absorption cooling cycle. Detailed thermodynamic, exergy and exergoeconomic analyses are performed for the proposed multigeneration system using Engineering Equation Solver (EES). A sensitivity study is also performed to study the effects of the main operational parameters on the proposed system performance. Finally, multi-objective optimization using a genetic algorithm approach in EES is carried out to reach the optimal design. The proposed system can consume 34.2% less energy input and reduce CO 2 emission by 39.3% compared to the stand-alone systems for power, cooling and freshwater production. The results show that the energy utilization factor and exergy efficiency of the proposed system are improved by 33.6% and 14.3%, respectively, while the total unit product cost is reduced by 11.3% compared to the stand-alone GT cycle. Further, from exergoeconomic optimization, the proposed system can produce 132.4 MW of power, 7.09 MW of cooling and 650 kg/s of freshwater at energy utilization factor of 57.5%, exergy efficiency of 39.7% and total unit product cost of 16.3 $/GJ.

42 ENGINEERING↗

Component-Level Analysis of Heating and Cooling Loads in the U.S. Residential Building Stock

The residential building sector accounts for a substantial portion of total energy consumption in the United States and offers a significant opportunity for energy reduction and decarbonization through improvements in energy efficiency. Heating and air conditioning are the primary contributors to residential energy usage and electricity system peak demand. However, due to the diversity of the housing stock and the complexity of factors affecting heating and cooling demand, identifying the relative contributions to heating and cooling loads poses challenges. To address this, we applied the ResStock analysis tool to simulate 550,000 building energy models, providing statistical representation of residential buildings in the contiguous United States. We introduced outputs that quantified the heating and cooling influence of different components of a home, such as air leakage, envelope components (ceilings, walls, windows, foundations), internal heat gains from people, lighting, plug loads, and duct losses and gains. Leveraging the granularity of ResStock, we present a dataset to enable deeper understanding of the contributors to heating and cooling loads as a function of housing characteristics such as location, envelope efficiency, and building type. This work aims to support prioritization of research and development and informed decision-making for residential building decarbonization.

building simulation↗

Heat and mass transfer during a sudden loss of vacuum in a liquid helium cooled tube - Part III: Heat deposition in He II

A sudden loss of vacuum can be catastrophic for superconducting particle accelerators. In such an event, air leaks into the liquid-helium-cooled accelerator beamline tube and condenses on its inner surface, causing rapid boiling of the helium and dangerous pressure build-up. Understanding the coupled heat and mass transfer processes is important for the design of the beamline cryogenic system. Our past experimental study on nitrogen gas propagating in a copper tube cooled by normal liquid helium (He I) has revealed a nearly exponential slowing down of the gas front. A theoretical model that accounts for the interplay of the gas dynamics and the condensation was developed, which successfully reproduced various key observations. However, since many accelerator beamlines are actually cooled by superfluid helium (He II) in which the heat transfer is via a non-classical thermal counterflow mode, we need to extend our work to the He II cooled tube. This paper reports our systematic measurements using He II and the numerical simulations based on a modified model that accounts for the He II heat-transfer characteristics. By tuning the He II peak heat-flux parameter in our model, we have reproduced the observed gas dynamics in all experimental runs. The fine-tuned model is then utilized to reliably evaluate the heat deposition in He II. Finallly, this work not only advances our understanding of condensing gas dynamics but also has practical implications to the design codes for beamline safety.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cooling dynamics of two titanium alloys during laser powder bed fusion probed with in situ X-ray imaging and diffraction

Metal parts produced by laser powder bed fusion (LPBF) additive manufacturing exhibit characteristic microstructures comparable to those observed in laser welding. The primary cause of this characteristic microstructure is rapid, localized heating and cooling cycles, which result in extreme thermal gradients where material solidification is followed by fast cooling in the solid state. The final microstructure and mechanical performance are also influenced by pore formation caused by melt pool fluid dynamics. Here, we use high speed, in situ X-ray diffraction to probe the kinetics of cooling and solid-solid phase transitions after laser melting in two aerospace titanium alloys: Ti-6Al-4V, an α + β alloy; and Ti-5Al-5V-5Mo-3Cr, a near-β alloy. We complement these diffraction studies with in situ X-ray imaging to probe melt pool dynamics and pore formation. From these two complementary probes, we quantify pore formation during melting and the subsequent microstructural evolution as the material rapidly cools after solidification. These results are critical for understanding defect formation and residual stress development in different titanium alloys under LPBF conditions and can help inform process models to predict final part performance.

36 MATERIALS SCIENCE↗

Evaluating direct vessel injection accident-event progression of AP1000 and key figures of merit to support the design and development of water-cooled small modular reactors

The passive safety systems (PSSs) within water-cooled reactors are meticulously engineered to function autonomously, requiring no external power source or manual intervention. They depend exclusively on inherent natural forces and the fundamental principles of reactor physics, such as gravity, natural convection, and phase changes, to manage, alleviate, and avert the release of radioactive materials into the environment during accident scenarios like a loss-of-coolant accident (LOCA). PSSs are already integrated into such operating commercial reactors as the Advanced Pressurized Reactor-1000 MWe (AP1000) and the Water-Water Energetic Reactor-1200 MWe (WWER-1200) are adopted in most of the upcoming small modular reactor (SMR) designs. Examples of water-cooled SMR PSSs are the passive emergency core-cooling system (ECCS), passive containment cooling system (PCCS), and passive decay-heat removal system, the designs of which vary based on reactor system-design requirements. However, understanding the accident-event progression and phases of a LOCA is pivotal for adopting a specific PSS for a new SMR design. This study covers the accident-event progression for direct vessel injection (DVI) small-break loss-of-coolant accident (SB-LOCA), associated physics phenomena, knowledge gaps, and important figures of merit (FOMs) that may need to be evaluated and assessed to validate thermal-hydraulics models with an available experimental dataset to support new SMR design and development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Using solar availability factors to adjust cool-wall energy savings for shading and reflection by neighboring buildings

The extent to which a solar-reflective “cool” wall can reduce a building's cooling load in summer or increase its heating load in winter scales with the wall's incident solar radiation, or solar availability. We assess how the solar availability at the wall of a central (modeled) building is affected by a neighboring wall across an urban canyon by calculating the central wall's solar availability factor (SAF), defined as the ratio of sunlight incident on the central wall in the presence of the neighboring wall to that incident in the absence of the neighboring wall. Cool-wall heating, ventilation, and air conditioning (HVAC) energy savings simulated for an isolated central building (no neighbors) can be multiplied by SAFs to account for interactions with neighboring walls. Monthly values of SAF were evaluated in 17 climates across the United States, including three in California, for north, east, south, and west central walls, over a wide range of canyon aspect ratio (height/width). Results for four representative aspect ratios—0.2, 1, 2, and 10—are presented. In Fresno, CA, monthly SAF ranges from 0.90 to 0.96 for central walls facing north, east, south, or west when the aspect ratio is 0.2 (two-story single-family homes across a street) and both the central and neighboring walls are conventional (albedo 0.25). Monthly SAFs decrease as aspect ratio rises, falling to 0.06–0.24 at an aspect ratio of 10 (adjacent 10-story buildings on the same side of the street). An example worked for a two-story single-family home in Fresno on the west side of a residential street yields SAFs of 0.47 (north), 0.92 (east), 0.50 (south), and 0.63 (west) to apply to the cool-wall annual HVAC energy savings computed for an isolated central building. Shading and reflection reduce the home's annual HVAC energy cost savings by 31%.

14 SOLAR ENERGY↗

Italian WEEE management system and treatment of end-of-life cooling and freezing equipments for CFCs removal

Highlights: • Italian data about WEEE management in the period 2005–2010 have been reported. • In 2001–2004 CFC release was monitored and Po Valley resulted as main source region. • The Italian directive on WEEE management was enacted in 2005 but took effect in 2008. • The CFC analytic procedures of the audit assessments have been discussed. - Abstract: This study presents and analyzes the data of the Italian system for take-back and recovery of waste electrical and electronic equipments (WEEEs) in the start-up period 2008–2010. The analysis was focused particularly on the data about the treatment of end-of-life cooling and freezing equipments. In fact, the wastes of cooling and freezing equipments have a high environmental impact. Indeed, in their compressor oil and insulation polyurethane (PU) foams chlorofluorocarbon (CFC) ozone-depleting gases are still present. In the period 2001–2004 Northern Italy resulted the main source in Europe of CFCs. The European Directive on WEEE management was enacted in 2002, but in Italy it was implemented by the legislative Decree in 2005 and it became operational in 2008. Actually, in 2008 the national WEEE Coordination Centre was founded in order to organize the WEEE pick-up process and to control collection, recovery and recycling targets. As a result, in 2010 the average WEEE collection per capita exceeded the threshold of more than 4 kg per inhabitant, as well as cooling and freezing appliances represented more than one fourth of the Italian WEEE collection stream. During the treatment of end-of-life cooling and freezing equipments, CFCs were recovered and disposed principally by burner methods. The analyses of defined specimens collected in the treatment facilities were standardized to reliably determine the amount of recovered CFCs. Samples of alkaline solid salt, alkaline saline solution, polyurethane matrix and compressor oil collected during the audit assessment procedure were analyzed and the results were discussed. In particular, the analysis of PU samples after the shredding and the warm pressing procedures measured a residual CFCs content around 500–1300 mg/kg of CFCs within the foam matrix.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Formation of Arctic Stratocumuli Through Atmospheric Radiative Cooling

Stratocumulus clouds are important to the Arctic climate because they are prevalent and exert a strong radiative forcing on the surface. However, relatively little is known about how stratocumulus clouds form in the Arctic. In this study, radiative transfer calculations are used to show that the timescale over which stably stratified Arctic temperature and water vapor profiles cool to saturation is less than typical residence times for individual air parcels in the Arctic. This result is consistent with previous studies in suggesting that elevated stratocumulus can form naturally through clear-sky radiative cooling during all seasons, without assistance from frontal lifting or other atmospheric forcing. Single column model simulations of the cloud formation process, after radiative cooling has resulted in saturation in a stably stratified profile, suggest that stratocumulus cloud properties are sensitive to the characteristics of the environment in which the formation process takes place. For example, sensitivity tests suggest that clouds may attain liquid water paths of over 50 g/m 2 if they form in moist environments but may become locked in a low-liquid water path quasi steady state or dissipate within hours if they form in dry environments. A potential consequence of these sensitivities is that when an Arctic stratocumulus layer forms by radiative cooling, it is more likely to become optically thick, optically thin, or dissipate than it is to obtain an intermediate optical thickness. This could help explain why the cloudy and radiatively clear atmospheric states are so prevalent across the Arctic.

54 ENVIRONMENTAL SCIENCES↗

Observed Increase in Tropical Cyclone‐Induced Sea Surface Cooling Near the U.S. Southeast Coast

Abstract Tropical cyclones (TCs) induce substantial upper‐ocean mixing and upwelling, leading to sea surface cooling. In this study, we explore changes in TC‐induced cold wakes along the United States (U.S.) Southeast and Gulf Coasts during 1982–2020. Our study shows a significant increase in TC‐induced sea surface temperature (SST) cooling of about 0.20°C near the U.S. Southeast Coast over this period. However, for the U.S. Gulf Coast, trends in TC‐induced SST cooling are insignificant. Analysis of the large‐scale oceanic environments indicate that the increasing TC‐induced cold wakes near the Southeast coast have been predominantly caused by the cooling of subsurface waters in that region. This upper‐ocean change is attributed to the enhancement of surface pressure gradient across land‐sea boundary and the associated increase in alongshore winds over there. Further analysis with climate models reveals the important role of anthropogenic forcings in driving these changes in the atmospheric circulation response along the U.S. Southeast Coast.

54 ENVIRONMENTAL SCIENCES↗

Combinatorial measurement of critical cooling rates in aluminum-base metallic glass forming alloys

Direct measurement of critical cooling rates has been challenging and only determined for a minute fraction of the reported metallic glass forming alloys. Here, we report a method that directly measures critical cooling rate of thin film metallic glass forming alloys in a combinatorial fashion. Based on a universal heating architecture using indirect laser heating and a microstructure analysis this method offers itself as a rapid screening technique to quantify glass forming ability. We use this method to identify glass forming alloys and study the composition effect on the critical cooling rate in the Al–Ni–Ge system where we identified Al 51 Ge 35 Ni 14 as the best glass forming composition with a critical cooling rate of 10 4 K/s.

36 MATERIALS SCIENCE↗

Global assessment of the carbon–water tradeoff of dry cooling for thermal power generation

Water scarcity and climate change are dual challenges that could potentially threaten energy security. Yet, integrated water–carbon management frameworks coupling diverse water- and carbon-mitigation technologies at high spatial heterogeneity are largely underdeveloped. Here we build a global unit-level framework to investigate the CO 2 emission and energy penalty due to the deployment of dry cooling—a critical water mitigation strategy—together with alternative water sourcing and carbon capture and storage under climate scenarios. We find that CO 2 emission and energy penalty for dry cooling units are location and climate specific (for example, 1–15% of power output), often demonstrating notably faster efficiency losses than rising temperature, especially under the high climate change scenario. Despite energy and CO 2 penalties associated with alternative water treatment and carbon capture and storage utilization, increasing wastewater and brine water accessibility provide potential alternatives to dry cooling for water scarcity alleviation, whereas CO 2 storage can help to mitigate dry cooling-associated CO 2 emission tradeoffs when alternative water supply is insufficient. By demonstrating an integrative planning framework, our study highlights the importance of integrated power sector planning under interconnected dual water–carbon challenges.

42 ENGINEERING↗

Heating and cooling of ligand-coated colloidal nanocrystals in solid films and solvent matrices

Ligand-to-nanocrystal heating and subsequent cooling to the environmental medium is investigated with infrared pump, electronic probe (IPEP) spectroscopy. Compared to solid films, solvated nanocrystals show faster ligand-to-nanocrystal heat equilibration (c. 11 ps versus c. 17 ps). Solvated nanocrystals also display more cooling of the hot ligand–nanocrystal complex on the experimentally measured time-scale, emphasizing the thermally insulating nature of semiconductor nanocrystal solids. Although heating transfer rates among solvents are all between 150 ps and 330 ps, cooling of the nanocrystal–ligand complex is slower, on average, in chlorinated solvents (c. 315 ps) compared to deuterated hydrocarbon solvents (c. 215 ps). Differences between chlorinated and hydrocarbon solvents show the importance of matching the vibrational energies of the solvent and the ligands for increasing the rate of heat transfer. Increases in the cooling time for poorer hydrocarbon solvents, in which nanocrystals aggregated, such as toluene, compared to better solvents, like methylcyclohexane, indicate that penetration of solvent into the ligand layer facilitates improved heat transfer to the matrix.

36 MATERIALS SCIENCE↗

Cryogenic performance of a cryocooler-cooled superconducting undulator

A cryocooler-cooled superconducting undulator has been installed and operated with beam at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The device consists of a dual-core 42-pole magnet structure that is cooled to 4.2 K with a system of four cryocoolers operating in a zero-boil-off configuration. This effort represents the culmination of a development program to establish concept feasibility and evaluate cryostat design and cryocooler-based refrigeration. Cryostat performance is described including cool-down/warm-up, steady-state operation, cooling margin, and the impact of beam during operation in the APS storage ring. Plans for future devices with longer magnets, which will incorporate lessons learned from the development program, are also discussed.

43 PARTICLE ACCELERATORS↗

Post-recombination early Universe cooling by translation–internal inter-conversion: The role of minor constituents

Little is known of the mechanism by which H and H{sub 2}, the principal constituents of the post-re-combination early Universe, cooled sufficiently to permit cluster formation, nucleosynthesis, and, eventually, the formation of structured objects. Radiative decay primarily cools the internal modes of H{sub 2}, as Δj = − 2 jumps accompany quadrupolar emission. This, however, would be a self-limiting mechanism. In this work, a translational energy cooling mechanism based on collision-induced, translation-to-internal mode conversion, is extended, following an earlier study [A. J. McCaffery and R. J. Marsh, J. Chem. Phys. 139, 234310 (2013)] of ensembles comprising H{sub 2} in a H atom bath gas. Here, the possible influence of minor species, such as HD, on this cooling mechanism is investigated. Results suggest that the influence of HD is small but not insignificant. Conversion is very rapid and an overall translation-to-internal energy conversion efficiency of some 5% could be expected. This finding may be of use in the further development of models of this complex phase of early Universe evolution. An unexpected finding in this study was that H{sub 2} + HD ensembles are capable of very rapid translation-to-internal conversion with efficiencies of >40% and relaxation rates that appear to be relatively slow. This may have potential as an energy storage mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of system size and cooling rate on the structure and properties of sodium borosilicate glasses from molecular dynamics simulations

We present that borosilicate glasses form an important glass forming system in both glass science and technologies. The structure and property changes of borosilicate glasses as a function of thermal history in terms of cooling rate during glass formation and simulation system sizes used in classical molecular dynamics (MD) simulation were investigated with recently developed composition dependent partial charge potentials. Short and medium range structural features such as boron coordination, Si and B Qn distributions, and ring size distributions were analyzed to elucidate the effects of cooling rate and simulation system size on these structure features and selected glass properties such as glass transition temperature, vibration density of states, and mechanical properties. Neutron structure factors, neutron broadened pair distribution functions, and vibrational density of states were calculated and compared with results from experiments as well as ab initio calculations to validate the structure models. The results clearly indicate that both cooling rate and system size play an important role on the structures of these glasses, mainly by affecting the 3B and 4B distributions and consequently properties of the glasses. It was also found that different structure features and properties converge at different sizes or cooling rates; thus convergence tests are needed in simulations of the borosilicate glasses depending on the targeted properties. Lastly, the results shed light on the complex thermal history dependence on structure and properties in borosilicate glasses and the protocols in MD simulations of these and other glass materials.

36 MATERIALS SCIENCE↗