Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condition monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Spectroscopic Online Monitoring: Using a Multi-Track Visible Spectrometer to Facilitate a Mass Balance Study in a Simulated TALSPEAK Process

Nuclear energy is a promising low-carbon energy candidate to meet the increased demand for green energy, where the integration of fuel recycling can have significant benefits for material usage and waste reduction. Utilizing in situ monitoring tools can provide ample opportunities to better control and safeguard nuclear material recycle processes while also offering knowledge and insight into real-time solution properties. The simultaneous measurement of analytical targets in multiple process locations can enable real-time mass balance and material accountancy calculations. This is demonstrated here with a mass balance study of Nd 3+ on countercurrent aqueous/organic metal extraction within a single centrifugal contactor. The Nd 3+ concentration was simultaneously monitored at the inlets and outlets of both aqueous and organic phases using a visible absorbance detector that allowed for the simultaneous measurement of up to six locations. The Nd 3+ concentration was calculated by using chemical data science algorithms, where model training sets were collected on a single track of the detector. The discussion includes addressing the challenges of using a model collected on a single track and applying it as a model across the other tracks on the detector. Each track of the detector corresponds to one measurement location on the contactor. The difference in the integrated moles of Nd 3+ between the inlet and outlet at the end of the experiment was near zero, indicating that the mass balance of this experiment was maintained. Overall, the online spectroscopic monitoring was able to follow changing solution conditions and accurately measure the concentration of Nd 3+ in different locations within the contactor system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and validation of a mathematical model of heart rate response to fluid perturbation

Physiological closed-loop controlled (PCLC) medical devices monitor and automatically adjust the patient’s condition by using physiological variables as feedback, ideally with minimal human intervention to achieve the target levels set by a clinician. PCLC devices present a challenge when it comes to evaluating their performance, where conducting large clinical trials can be expensive. Virtual physiological patients simulated by validated mathematical models can be utilized to obtain preclinical evidence of safety and assess the performance of the PCLC medical device during normal and worst-case conditions that are unlikely to happen in a limited clinical trial. A physiological variable that plays a major role during fluid resuscitation is heart rate (HR). For in silico assessment of PCLC medical devices regarding fluid perturbation, there is currently no mathematical model of HR validated in terms of its predictive capability performance. This paper develops and validates a mathematical model of HR response using data collected from sheep subjects undergoing hemorrhage and fluid infusion. The model proved to be accurate in estimating the HR response to fluid perturbation, where averaged between 21 calibration datasets, the fitting performance showed a normalized root mean square error (NRMSE) of 7.41 ± 2.8%. The model was also evaluated in terms of model predictive capability performance via a leave-one-out procedure (21 subjects) and an independent validation dataset (6 subjects). Two different virtual cohort generation tools were used in each validation analysis. The generated envelope of virtual subjects robustly met the defined acceptance criteria, in which 95% of the testing datasets presented simulated HR patterns that were within a deviation of 50% from the observed data. In addition, out of 16000 and 18522 simulated subjects for the leave one-out and independent datasets, the model was able to generate at least one virtual subject that was close to the real subject within an error margin of 9.56 ± 3.15% and 11.1 ± 1.22% NRMSE, respectively. In conclusion, the model can generate valid virtual HR physiological responses to fluid perturbation and be incorporated into future non-clinical simulated testing setups for assessing PCLC devices intended for fluid resuscitation.

59 BASIC BIOLOGICAL SCIENCES↗

The Prompt Processing System and Data Quality Monitoring in the ProtoDUNE-SP Experiment

The DUNE Collaboration is conducting an experimental program (named protoDUNE) which involves a beam test of two large-scale prototypes of the DUNE Far Detector at CERN operating in 2018-2019. The volume of data to be collected by the protoDUNE-SP (the single-phase detector) will amount to a few petabytes and the sustained rate of data sent to mass storage is in the range of a few hundred MB per second. After collection the data is committed to storage at CERN and transmitted to Fermi National Accelerator Laboratory in the US for processing, analysis and long-term preservation. The protoDUNE experiment requires substantial Data Quality Monitoring capabilities in order to ascertain the condition of the detector and its various subsystems. We present the design of the protoDUNE Prompt Processing System, its deployment at CERN and its performance during the data challenges and actual data taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Watchdog for ARM Radar Network Operations

WARNO is a software system designed to monitor the radars in the ARM Radar Network. It allows real time monitoring and tracking of instrument state and condition. It provides a web portal on the front end to interact with users, a REST API webpoint for interactions with third party systems, and an internal distributed architecture to allow it to be deployed at multiple sites.

Source record↗

Improved quality metrics for association and reproducibility in chromatin accessibility data using mutual information

Correlation metrics are widely utilized in genomics analysis and often implemented with little regard to assumptions of normality, homoscedasticity, and independence of values. This is especially true when comparing values between replicated sequencing experiments that probe chromatin accessibility, such as assays for transposase-accessible chromatin via sequencing (ATAC-seq). Such data can possess several regions across the human genome with little to no sequencing depth and are thus non-normal with a large portion of zero values. Despite distributed use in the epigenomics field, few studies have evaluated and benchmarked how correlation and association statistics behave across ATAC-seq experiments with known differences or the effects of removing specific outliers from the data. Here, we developed a computational simulation of ATAC-seq data to elucidate the behavior of correlation statistics and to compare their accuracy under set conditions of reproducibility. Using these simulations, we monitored the behavior of several correlation statistics, including the Pearson’s R and Spearman’s ρ coefficients as well as Kendall’s τ and Top–Down correlation. We also test the behavior of association measures, including the coefficient of determination R 2 , Kendall’s W, and normalized mutual information. Our experiments reveal an insensitivity of most statistics, including Spear man’s ρ, Kendall’s τ, and Kendall’s W, to increasing differences between simulated ATAC-seq replicates. The removal of co-zeros (regions lacking mapped sequenced reads) between simulated experiments greatly improves the estimates of correlation and association. After removing co-zeros, the R 2 coefficient and normalized mutual information display the best performance, having a closer one-to-one relationship with the known portion of shared, enhanced loci between simulated replicates. When comparing values between experimental ATAC-seq data using a random forest model, mutual information best predicts ATAC-seq replicate relationships. Collectively, this study demonstrates how measures of correlation and association can behave in epigenomics experiments. We provide improved strategies for quantifying relationships in these increasingly prevalent and important chromatin accessibility assays.

59 BASIC BIOLOGICAL SCIENCES↗

In situ neutron and synchrotron diffraction of La0.9Sr0.1Co1-yFeyO3 (y=0, 0.25, 0.75, 1)

Powder La0.9Sr0.1Co1-yFeyO3 (y=0, 0.25, 0.75, 1) samples were probed via in situ neutron (POWGEN, Spallation Neutron Source, Oak Ridge National Laboratory) and synchrotron (11-BM, Advanced Photon Source, Argonne National Lab) diffraction cycling between methane and air at temperatures ranging from room temperature to 850 C. Mail in neutron data (POWGEN) was collected on the samples at room temperature and 10 K. Additionally, gas production under similar reaction conditions as the in situ diffraction as monitored by Gasboard 3100 (California State University, Fullerton) is also included.

catalysis↗

Flexible Distributed Energy & Water from Waste for Food and Beverage Industry

Food and beverage plants inherently consume a large quantity of water and generate a high volume of wastewater rich in organic content. On one hand, water discharge regulations are getting more stringent over the time, necessitating the use of different technologies to reduce the amount of wastewater and improve the effluent water quality. On the other hand, growing energy and water costs are driving the plants to extract and reuse valuable energy and water from the wastewater stream. An integrated waste-tovalue system uses a combination of anaerobic digester (AD), reciprocating gas engine/boiler, membrane bioreactor (MBR), and reverse osmosis (RO) to recover valuable energy as heat and/or electricity as well as purify the water for reuse. While individual anaerobic digestion and membrane bioreactors are being used in increasing numbers, there is a growing need to integrate them together in a waste-to-value system for enhanced energy and water recovery. However, currently operation of these systems relies heavily on the plant operator to perform periodic sampling and off-line lab analysis to monitor the system performance, detect any abnormal condition due to variations in the wastewater and decide on appropriate remedial action needed. This leads to a conservative design and operation of these systems to avoid any potential upsets that can destabilize the system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review of Quantitative Monitoring Methodologies for Emissions Verification and Accounting for Carbon Dioxide Capture and Storage for California’s Greenhouse Gas Cap-and-Trade and Low-Carbon Fuel Standard Programs

The Cap-and-Trade and Low Carbon Fuel Standard (LCFS) programs being administered by the California Air Resources Board (CARB) include Carbon Dioxide Capture and Storage (CCS) as a potential means to reduce greenhouse gas (GHG) emissions. However, there is currently no universal standard approach that quantifies GHG emissions reductions for CCS and that is suitable for the quantitative needs of the Cap-and-Trade and LCFS programs. CCS involves emissions related to the capture (e.g., arising from increased energy needed to separate carbon dioxide (CO 2 ) from a flue gas and compress it for transport), transport (e.g., by pipeline), and storage of CO 2 (e.g., due to leakage to the atmosphere from geologic CO 2 storage sites). In this project, we reviewed and compared monitoring, verification, and accounting (MVA) protocols for CCS from around the world by focusing on protocols specific to the geologic storage part of CCS. In addition to presenting the review of these protocols, we highlight in this report those storage-related MVA protocols that we believe are particularly appropriate for CCS in California. We find that none of the existing protocols is completely appropriate for California, but various elements of all of them could be adopted and/or augmented to develop a rigorous, defensible, and practical surface leakage MVA protocol for California. The key features of a suitable surface leakage MVA plan for California are that it: (1) informs and validates the leakage risk assessment, (2) specifies use of the most effective monitoring strategies while still being flexible enough to accommodate special or site-specific conditions, (3) quantifies stored CO 2 , and (4) offers defensible estimates of uncertainty in monitored properties. California’s surface leakage MVA protocol needs to be applicable to the main CO 2 storage opportunities (in California and in other states with entities participating in California’s Cap-and-Trade or LCFS programs), specifically CO 2 -enhanced oil recovery (CO 2 -EOR), CO 2 injection into depleted gas reservoirs (with or without CO 2 -enhanced gas recovery (CO 2 -EGR)), as well as deep saline storage. Regarding the elements of an effective surface leakage MVA protocol, our recommendations for California are that: (1) both CO 2 and methane (CH 4 ) surface leakage should be monitored, especially for enhanced recovery scenarios, (2) emissions from all sources not directly related to injection and geologic storage (e.g., from capture, or pipeline transport) should be monitored and reported under a plan separate from the surface leakage MVA plan that is included as another component of the quantification methodology (QM), (3) the primary objective of the surface leakage MVA plan should be to quantify surface leakage of CO 2 and CH 4 and its uncertainty, with consideration of best-practices and state-of-the-art approaches to monitoring including attribution assessment, (4) effort should be made to monitor CO 2 storage and migration in the subsurface to anticipate future surface leakage monitoring needs, (5) detailed descriptions of specific monitoring technologies and approaches should be provided in the MVA plan, (6) the main purpose of the CO 2 injection project (CO 2 -EOR, CO 2 -EGR, or pure geologic carbon sequestration (GCS)) needs to be stated up front, (7) approaches to dealing with missing data and quantifying uncertainty need to be described, and (8) post-injection monitoring should go on for a period consistent with or longer than that prescribed by the U.S. EPA.

54 ENVIRONMENTAL SCIENCES↗

Unsupervised Machine Learning for Evaluation of Aging in Explosive Pressed Pellets

This project is an evaluation of the changes in the dimensional geometry of pressed explosive powder pellets when stored for prolonged periods under unmonitored storage conditions. Through the application of Structural Health Monitoring (SHM) techniques, questions to be answered by this investigation are what, if any, effect has the long-term storage of the pellets had on their physical attributes and, if changes have occurred, are the resulting differences of significant magnitude to affect the performance of the pellets. This resulting report includes a summary of the relevant background information, explanation of the SHM approach used to analyze the available data, presentation and discussion of the results, concluding remarks, and an accompanying appendix containing the MATLAB program developed for the project.

36 MATERIALS SCIENCE↗

Evaluating the Long-Term Ecological Responses to Riparian Ecosystem Restoration at the Fort Benning, Georgia Military Installation

Riparian and instream restorations are commonly implemented to improve ecosystem condition. However, very few restoration activities are monitored for multiple years to assess long-term effectiveness. At the Department of Defense’s Fort Benning Military Installation (FBMI) in west-central Georgia, two experimental restoration projects (ephemeral drainage revitalization and instream habitat augmentation [i.e., coarse woody debris (CWD) additions]) were implemented ~14 years ago with the goal of reducing environmental impacts of military training activities. A SERDP project found that instream restoration improved some aspects of ecosystem function and community structure but not others. The objective of the current study was to re-evaluate the effect of these restoration practices on stream ecosystem processes ~14 years after implementation.

54 ENVIRONMENTAL SCIENCES↗

Abstract for CRADA between National Energy Technology Laboratory and Shell International Exploration & Production, Inc

Introducing CO₂ into geothermal systems as a working fluid in reservoirs can enhance geothermal conductivity, production, and pressure maintenance. A cross-disciplinary interaction of geothermal reservoir stimulation and CO₂ utilization satisfies renewable energy demands and operations that support sustainable energy infrastructure. Challenges to implementing CO₂-stimulated geothermal enhancement (CS-GE) include (1) accurately characterizing and imaging CO₂-stimulated geothermal reservoirs; (2) quantitatively inferring CS-GE evolution under current and future engineered conditions for cost effective operations; and (3) monitoring resources by improving observational methods to advance the understanding of complex geothermal systems for sweep efficiency and, ultimately, cost effectiveness. NETL and Shell will collaborate under this CRADA to develop software to image key features, including CO₂-stimulated fracture imaging, CO₂ fluid sweep imaging and heat transfer and exchange imaging by leveraging available datasets and applying advanced Artificial Intelligence/Machine Learning (AI/ML), multi-level data analytics and data/information fusion to better understand the comprehensive mechanisms of CO₂-stimulated geothermal systems.

15 GEOTHERMAL ENERGY↗

Defining Detection Limits for Continuous Monitoring Systems for Methane Emissions at Oil and Gas Facilities

Networks of fixed-point continuous monitoring systems are becoming widely used in the detection and quantification of methane emissions from oil and gas facilities in the United States. Regulatory agencies and operators are developing performance metrics for these systems, such as minimum detection limits. Performance characteristics, such as minimum detection limits, would ideally be expressed in emission rate units; however, performance parameters such as detection limits for a continuous monitoring system (CMS) will depend on meteorological conditions, the characteristics of emissions at the site where the CMS is deployed, the positioning of CMS devices in relation to the emission sources, and the amount of time allowed for the CMS to detect an emission source. This means that certifying the performance of a CMS will require test protocols with well-defined emission rates and durations; initial protocols are now being used in field tests. Field testing results will vary, however, depending on meteorological conditions and the time allowed for detection. This work demonstrates methods for evaluating CMS performance characteristics using dispersion modeling and defines an approach for normalizing test results to standard meteorological conditions using dispersion modeling.

Chen, Qining (ORCID:0000000316908091)↗

Physiological response in pilot/back-seat man during aerial combat maneuvers in F-4E aircraft.

Comparison of objective/subjective physiological data between the pilot and the back-seat man during training within the G maneuvering envelope. It appears that the psychological requirements for the pilot to be mentally alert and physiologically adapted to a continually changing environment places additional responsibility on him to the extent the physiological signs monitored are indicative of a high stress condition and are increased by a significant amount over the back-seat man who is, in most instances, riding passively.

Leverett, S. D., Jr.↗

Correlation of ERTS-1 and aircraft optical data with water quality parameters of Charlotte Amalie Harbor, St. Thomas, Virgin Islands

The author has identified the following significant results. Attempts to correlate optical aircraft remote sensing of water quality with the optical data from the ERTS-1 satellite using calibrated imagery of Charlotte Amalie harbor, St. Thomas, Virgin Islands are reported. The harbor at Charlotte Amalie has a concentration of a number of factors affecting water quality: untreated sewage, land runoff, and sediment from navigation and dredging operations. Calibration procedures have been originated and applied to ERTS-1 and I2S camera imagery. The results indicate that the ERTS-1 and I2S imagery are correlated with optical in situ measurements of the harbor water. The aircraft green photographic and ERTS-1 MSS-4 bands have been found most suitable for monitoring the scattered light levels under the conditions of the investigation. The chemical parameters of the harbor water were found to be correlated to the optical properties for two stations investigated in detail. The biological properties of the harbor water (chlorophyll and carotenoids), correlate inversely with the optical data near the pollution sources compared to further away. Calibration procedures developed in this investigation were essential to the interpretation of the photographic and ERTS-1 photometric responses.

Coulbourn, W. C.↗

Boundaries of ERTS and aircraft data within which useful water quality information can be obtained

Calibration procedures have been devised and applied to ERTS-1, multispectral, true color, and false color imagery. The results indicate that the ERTS and multispectral imagery are correlated with optical in situ measurements of the harbor water. Correlation is extended to true and false color imagery through in situ optical measurements of the harbor water. The best photometric accuracy is achieved with multispectral aerial imagery and the use of bulk MSS tape. The aircraft green photographic and ERTS-1 MSS-4 bands have been found most suitable for monitoring the scattered light levels under the conditions of this investigation. The application of satellite or aircraft for optical remote sensing depends upon the physical scale and frequency of sensing since both sensor systems generally have sufficient photometric sensitivity. The chemical parameters of the harbor water were found to be correlated to the optical properties for two stations investigated in detail.

Egan, W. G.↗

A generalized correlation of experimental flat-plate collector performance

A generalized collector performance correlation was derived and shown by experimental verification to be of the proper form to account for the majority of the variable conditions encountered both in outdoor and in indoor collector tests. This correlation permits a determination of collector parameters which are essentially nonvarying under conditions which do vary randomly (outdoors) or conditions which vary in a controlled manner (indoors - simulator). It was shown that correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs; (2) collector performance prediction under conditions that differ from the conditions of the test program; and (3) monitoring performance degradation effects.

Simon, F. F.↗