Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Methods for separating components

Method for concentrating components through a distillation column are disclosed. A process stream is provided containing hydrocarbons, carbon dioxide, and water. The process stream is passed into the distillation column at a bottom portion of the distillation column. The process stream is fractionally distilled in the distillation column, forming an overhead vapor stream, a middle fluid stream, and a bottoms liquid stream. The middle fluid stream is removed from a middle location of the distillation column. The bottoms liquid stream is removed from the distillation column. The overhead vapor stream is removed from the distillation column. The middle fluid stream consists of a first portion of the carbon dioxide and a first portion of the hydrocarbons. The bottoms liquid stream consists of a second portion of the hydrocarbons as a first phase and substantially all the water as a second phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Estimation of Deposition Behavior of Supersaturated Silicic Acid around Geological Disposal Facility - 19137

For safety evaluation about the geological disposal system, the leakage of radionuclides with groundwater flow is estimated by considering the groundwater flow through the manmade and natural barriers. In such an estimate, we should also consider the influence of cement materials used for the construction of the disposal facility system. Cement material including high alkalinity alters groundwater condition up to 13 in pH and dissolves numerous silicate materials, which release silicic acid to groundwater. Since this groundwater mixes with natural groundwater downstream, supersaturated silicic acid will be produced with the decrease of pH to 8 around the repository system. Thus, in this study, the behavior of supersaturated silicic acid in a flow system was examined by using the column packed with amorphous silica particles under the condition of constant hydraulic head. The packed length is 20 mm or 40 mm, and the supersaturated silicic acid solution was continuously injected into the column. Here, the supersaturated silicic acid was adjusted by mixing with distilled water of pH 8 just before the solution was injected into the column. In the results, the supersaturated silicic acid quickly deposited in the packed column, and colloidal silicic acid was not detected at the outlet of the column. The deposition amount of supersaturated silicic acid in the column decreased with time, and became larger in the longer column. Besides, the flow rate decreased with the deposition of supersaturated silicic acid. Thus, this study monitored the decrease rate of permeability with the supply amount of silicic acid. In the results, the change rate did not depend on packed length. This suggested that even with a short packed length, by considering the amount of precipitation of supersaturated silicic acid, it is possible to estimate the change in permeability similarly to the case of a long packed length. Such a decrease effect in permeability may contribute to retarding the migration of radionuclides around the repository. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Custom Machine to Convey Radiologically Impacted Cohesive Soils to the Orion ScanSortSM System - 20382

An established method to reduce the volume of material required to be disposed of as radioactive waste is conveyor-based sorting of potentially radiologically impacted soils. With the Orion ScanSortSM system, potentially impacted soils are conveyed beneath radiation detectors and sorted into above and below criteria bins based on the detectors' response. Confident measurements can only be efficiently achieved when the soil column being conveyed has a reasonably consistent geometry. Highly cohesive soils present a very significant challenge as they tend to clump and adhere to the conveyor hopper, strike-off bar, and belt skirting. This causes voids and valleys in the soil column that affect the measurement geometry and reduce the confidence in the measurement. The reduction in confidence necessitates a longer residence time (i.e. reduction in conveyor belt speed and processing rates) or that the soils in highly unfavorable geometries be dispositioned as impacted or segregated for resurvey (should site logistics support that option). These outcomes may increase the volume of material required to be dispositioned as radiological waste and have a negative impact on project cost and schedule. To minimize impact to sorting operations, Wood designed and built a customized Extruder, to optimize the soil column prior to assay. The design was developed and refined to minimize the volume of highly cohesive soils presented in highly unfavorable geometries in the soil column in order to confidently assess and disposition such soils in a high-production environment. The Extruder is a customized 90 cm wide flat conveyor that has an oversized hopper with a pair of motor-driven rollers that force the soils in the hopper through an opening of adjustable height. The soils are extruded through the opening to produce a soil column that is ∼75 cm wide and ∼8-18 cm deep with a design rate of 225 metric tons/hr. The Extruder was recently deployed with the Orion ScanSort{sup SM} System to a site in northeast Ohio. The site has highly cohesive soils that result from the weathering of glacial sediments and consist of clay and clay loam, resulting in poor drainage and high moisture content. The project infrastructure only supported two bins of material (above and below criteria), which necessitated that soils with unfavorable geometries be discharged into the above criteria bin, along with material determined to have been contaminated. The Extruder was extremely successful in producing a stable soil column with favorable geometries for radiological assay. During production, less than 0.5% (by mass) of the soils processed were presented in unsatisfactory geometries requiring disposition as radioactive waste. The Extruder did not get clogged due to the cohesive soils (as is typical with conventional conveyors) and required very little maintenance, again minimizing impacts to sorting operations. The conveyor belt speed was operated at 14 cm/s with a typical belt loading of ∼109 kg/m resulting in a mean process rate of ∼49 metric tons/hr. The process rate was constrained by other project logistics, rather than by the capabilities of the Extruder, which was operated at less than 20% of the maximum design speed (75 cm/s). It is concluded that the Extruder is highly likely to produce a stable highly cohesive soil column suitable for efficient and confident radiological assay in production environments of 250 short tons/hr or more. The Extruder has the capability to drastically reduce the duration and costs of projects with radiologically impacted highly cohesive soils. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Testing of Crystalline Silicotitanate to Support Tank-Side Cesium Removal System Operations - 20458

The direct feed of waste from the Hanford tank farms to the Low-Activity Waste Facility at the Hanford Waste Treatment and Immobilization Plant requires an intermediate treatment step that prepares the waste for vitrification. Washington River Protection Solutions (WRPS) selected a near-tank treatment system known as the Tank-Side Cesium Removal (TSCR) system to perform the required intermediate treatment functions. The approach in the TSCR system is to filter waste supernatant with a sintered metal dead-end filter and then use a series of ion exchange columns to remove cesium; this system has several similarities to the Tank Closure Cesium Removal system that has been deployed on the Savannah River Site. The ion exchange media proposed for use is crystalline silicotitanate (CST), which is a non-elutable media with a high affinity for cesium. Because the media is non-elutable, loaded columns will be blown down with compressed air, moved into interim storage, and replaced with new columns when cesium capacity is reached. The assumed extent and rate of drying that could be achieved in the TSCR column geometry lacked confirmation by experimental data. In addition, once the columns are loaded with cesium, they generate flammable gases (primarily hydrogen) via radiolysis acting on any resident liquids, i.e., moisture, remaining in the media bed. An assessment of available information on CST concluded that gas generation data that bounds expected operational conditions were needed to support the TSCR system safety basis and planned operations. Working with WRPS, Pacific Northwest National Laboratory (PNNL) designed and conducted testing with CST media to address the need for (a) representative in-column drying data, and (b) bounding flammable gas generation data. Drying testing was performed using a full-height column with a diameter of approximately 2 inches with injected air at temperatures of 18 deg. C and 30 deg. C. Gas generation testing was conducted in an engineered bunker that allowed simultaneous irradiation of up to eight samples at a time. These two experimental approaches used at PNNL for the CST testing are summarized and the major outcomes are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stationary phase deposition based on onium salts

Onium salt chemistry can be used to deposit very uniform thickness stationary phases on the wall of a gas chromatography column. In particular, the stationary phase can be bonded to non-silicon based columns, especially microfabricated metal columns. Non-silicon microfabricated columns may be manufactured and processed at a fraction of the cost of silicon-based columns. In addition, the method can be used to phase-coat conventional capillary columns or silicon-based microfabricated columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory differential simulation design method of pressure absorbers for carbonization of phenolate solution by carbon dioxide in coal-tar processing

A laboratory differential simulation method is used for the design of carbonization columns at coal-tar processing in which phenols are regenerated from phenolate solution by carbon dioxide absorption. The design method is based on integration of local absorption rates of carbon dioxide along the column. The local absorption rates into industrial phenolate mixture are measured in a laboratory model contactor for various compositions of the gas and liquid phases under the conditions that ensure the absorption rates in the laboratory absorber simulate the local rates in the industrial column. On the bases of the calculations, two-step carbonization columns were designed for 30000 t/year of the phenolate solution treatment by carbon dioxide. The absorption proceeds at higher pressure of 500 kPa and temperatures from 50 to 65 C, pure carbon dioxide is used and toluene is added. These conditions have the following favourable effects: (I) significant size reduction of the columns, (ii) it is possible to process more concentrated solutions without danger of silting the columns by crystallization of NaHCO{sub 3} on the packing. (iii) small amount of inert gas is released, (iv) lower alkalinity and better separability of the organic phase (phenols with toluene) from water phase (soda or bicarbonate solution) in separators.

01 COAL, LIGNITE, AND PEAT↗

Heat exchanges in fast, high-performance liquid chromatography. A complete thermodynamic study

The successive physical transformations of the mobile phase that take place in very high pressure liquid chromatography were studied based on the formalism of classical thermodynamics. The eluent is initially under atmospheric pressure (P{sup 0}) and at ambient temperature (T{sub ext}). In a first step, it is compressed to a high pressure (P{sub max} of the order of 1 kbar) in the pump heads of the chromatograph. In a second step, the pressurized eluent is transferred to the inlet of the chromatographic column, along which, in a third step, it is decompressed to atmospheric pressure. Both the compression and the decompression of the fluid were considered to take place under conditions that can be either adiabatic or nonadiabatic and either reversible or irreversible. Applications of the first and second principles of thermodynamics allow the determination of the heat and energy exchanged between the eluent and the external surroundings during each transformation. Experimental data were acquired using acetonitrile as the mobile phase. The true state equation, {rho}(P, T), of liquid acetonitrile was used in the theoretical calculations. A series of four different flow rates (0.55, 0.85, 1.15, and 1.45 mL/min, corresponding to inlet pressures of 357.2, 559.5, 765.1, and 972.9 bar, respectively), were applied to a 2.1 x 100 mm column packed with 1.7-{micro}m bridged ethane-silicon hybrid particles. Thermocouples were used to measure the eluent temperature before and after its passage through the column. These data provide estimates of the variation of the internal energy of the eluent. The heat lost through the external wall of the column during the eluent decompression was estimated by measuring the surface temperature of the column tube under steady state. Both the compression and the decompression of acetonitrile were found to be nonadiabatic and irreversible transformations. The results showed that, during the eluent decompression, the heat released by the friction forces serves four different purposes: (1) it increases the eluent entropy at constant temperature (for 35%); (2) it increases the temperature of the eluent (for 5%); (3) it provides heat to the laboratory atmosphere (for 5%); and (4) it provides some work inside the column (for 5%). This quantitative heat balance description accounts well for the actual performance of the new, very high pressure liquid chromatographic technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous Separation of Protactinium-230 and Uranium-230 Isotopes from a Proton-Irradiated Thorium Matrix

The use of radioisotopes in cancer therapy is becoming increasingly important. As a potential candidate for targeted alpha therapy, 230 U (t 1/2 = 20.8 d), the decay daughter of 230 Pa (t 1/2 = 17.4 d) is currently being investigated for cancer treatment. For radioisotopes to be used in biomedicine, they must be radiochemically pure and free from carrier interference. This can be challenging given their short half-life. Thus, in this study, radiological separation methods for harvesting isotopes for use in biomedicine must be simple, fast, and capable of obtaining the required purity levels. Herein, we demonstrate a new rapid method for the separation of 230 U and 230 Pa from a proton-irradiated 232 Th metal target and from coproduced fission products with high recovery and purity. A dual-column approach was used, in which the first column was an anion exchange (AX) column and the second column was a DGA column. The MP-1 AX resin was used for the primary separation of the three major components (U, Pa, and Th, as well as fission products), and the DGA column was used for further purification of the separated 230 U. The method is simple and allows for straightforward separation of U, Pa, Th, and fission products; also, the entire process from target dissolution to shipment of 230 U could be completed in 3 days with an overall 230 U recovery yield of 96 ± 3%. Additionally, separated 230 Pa fractions can be used to harvest ingrown 230 U after initial separation.

DGA resin↗

Cryogenic distillation facility for isotopic purification of protium and deuterium

Isotopic purification of the protium and deuterium is an important requirement of many physics experiments. A cryogenic facility for high-efficiency separation of hydrogen isotopes with a cryogenic distillation column as the main element is described. The instrument is portable, so that it can be used at the experimental site. It was designed and built at the Petersburg Nuclear Physics Institute, Gatchina, Russia. Fundamental operating parameters have been measured including a liquid holdup in the column packing, the pressure drops across the column and the purity of the product at different operating modes. A mathematical model describes expected profiles of hydrogen isotope concentration along the distillation column. An analysis of ortho-parahydrogen isomeric composition by gas chromatography was used for evaluation of the column performance during the tuning operations. The protium content during deuterium purification (≤100 ppb) was measured using gas chromatography with accumulation of the protium in the distillation column. A high precision isotopic measurement at the Institute of Particle Physics, ETH-Zurich, Switzerland, provided an upper bound of the deuterium content in protium (≤6 ppb), which exceeds all commercially available products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Permeable Reactive Biobarriers for In Situ Cr(VI) Reduction: Bench Scale Tests Using Cellulomonas sp. Strain ES6

Chromate (Cr(VI)) reduction studies were performed in bench scale flow columns using the fermentative subsurface isolate Cellulomonas sp. strain ES6. In these tests, columns packed with either quartz sand or hydrous ferric oxide (HFO)-coated quartz sand, were inoculated with strain ES6 and fed nutrients to stimulate growth before nutrient-free Cr(VI) solutions were injected. Results show that in columns containing quartz sand, a continuous inflow of 2 mg/L Cr(VI) was reduced to below detection limits in the effluent for durations of up to 5.7 residence times after nutrient injection was discontinued proving the ability of strain ES6 to reduce chromate in the absence of an external electron donor. In the HFO-containing columns, Cr(VI) reduction was significantly prolonged and effluent Cr(VI) concentrations remained below detectable levels for periods of up to 66 residence times after nutrient injection was discontinued. Fe was detected in the effluent of the HFO-containing columns throughout the period of Cr(VI) removal indicating that the insoluble Fe(III) bearing solids were being continuously reduced to form soluble Fe(II) resulting in prolonged abiotic Cr(VI) reduction. Thus, growth of Cellulomonas within the soil columns resulted in formation of permeable reactive barriers that could reduce Cr(VI) and Fe(III) for extended periods even in the absence of external electron donors. Other bioremediation systems employing Fe(II)-mediated reactions require a continuous presence of external nutrients to regenerate Fe(II). After depletion of nutrients, contaminant removal within these systems occurs by reaction with surface-associated Fe(II) that can rapidly become inaccessible due to formation of crystalline Fe-minerals or other precipitates. The ability of fermentative organisms like Cellulomonas to reduce metals without continuous nutrient supply in the subsurface offers a viable and economical alternative technology for in situ remediation of Cr(VI)-contaminated groundwater through formation of permeable reactive biobarriers (PRBB).

54 ENVIRONMENTAL SCIENCES↗

Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: Analysis of human plasma and cerebrospinal fluid

Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

59 BASIC BIOLOGICAL SCIENCES↗

Process Intensification in Multicomponent Distillation: A Review of Recent Advancements

Process Intensification (PI) is an emerging concept in chemical engineering that describes the design innovations that lead to significant shrinkage in size and boost in efficiency of a process plant. Distillation, the most commonly used separation technique in the chemical industry, is a crucial component of PI. We systematically discuss the following aspects of PI in non-azeotropic multicomponent distillation: 1) Introducing thermal couplings to eliminate intermediate reboilers and condensers to save energy and capital cost; 2) Improving operability of thermally coupled columns by means of eliminating vapor streams in thermal couplings with only liquid transfers or column section rearrangement; 3) Enabling double and multi-effect distillation of thermally coupled configurations to further reduce heat duty; 4) Performing simultaneous heat and mass integration among thermally coupled columns to reduce the number of columns and heat duty; and 5) Conducting any thermally coupled distillation in n-product streams using 1 to n - 2 column shells with operable novel dividing wall columns. We demonstrate these aspects of PI through examples to illustrate how they lead to compact, easy-to-operate, energy efficient and cost effective multicomponent distillation system designs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Numerical modeling of elution peak profiles in supercritical fluid chromatography. Part I-Elution of an unretained tracer

When chromatography is carried out with high-density carbon dioxide as the main component of the mobile phase (a method generally known as 'supercritical fluid chromatography' or SFC), the required pressure gradient along the column is moderate. However, this mobile phase is highly compressible and, under certain experimental conditions, its density may decrease significantly along the column. Such an expansion absorbs heat, cooling the column, which absorbs heat from the outside. The resulting heat transfer causes the formation of axial and radial gradients of temperature that may become large under certain conditions. Due to these gradients, the mobile phase velocity and most physico-chemical parameters of the system (viscosity, diffusion coefficients, etc.) are no longer constant throughout the column, resulting in a loss of column efficiency, even at low flow rates. At high flow rates and in serious cases, systematic variations of the retention factors and the separation factors with increasing flow rates and important deformations of the elution profiles of all sample components may occur. The model previously used to account satisfactorily for the effects of the viscous friction heating of the mobile phase in HPLC is adapted here to account for the expansion cooling of the mobile phase in SFC and is applied to the modeling of the elution peak profiles of an unretained compound in SFC. The numerical solution of the combined heat and mass balance equations provides temperature and pressure profiles inside the column, and values of the retention time and efficiency for elution of this unretained compound that are in excellent agreement with independent experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An optimization approach for cryogenic distillation-based protium removal systems in magnetic fusion energy fuel cycles

Tritium inventory reduction for fusion power plants is central to the successful adoption of fusion energy. The advent of direct internal recycling in deuterium-tritium fusion fuel cycle design has led to significant reduction in startup tritium inventory estimates for fusion power plants but requires an isotope rebalancing and protium removal (IRPR) system to ensure acceptable isotopic fuel composition. Cryogenic distillation is a potential solution for near-term deployment in an IRPR system due to its demonstrated performance in similar operating regimes. Using protium removal in the fuel cycle as the primary performance metric, this paper presents an optimization methodology for a single-column continuous cryogenic distillation-based IRPR system for a 500 MW fus magnetic fusion device. Distillation column optimization was performed using the CryOgenic Distillation For Isotopic Separation of Hydrogen (CODFISH) code developed at Savannah River National Laboratory. The distillation column design presented maximizes direct recycling of hydrogen isotopes from the fusion chamber exhaust to the fueling system while minimizing IRPR system steady-state tritium inventory. The optimized IRPR distillation column presented achieves direct recycling of 60 % of the hydrogen isotopes in the fusion chamber exhaust with an estimated steady-state system tritium inventory <30 g. In conclusion, the optimized IRPR distillation column operation was then used to estimate the design requirements for a detritation column to treat the IRPR system effluent stream.

CryOgenic distillation↗

Process design of the piperazine advanced stripper for a 460 MW NGCC

The Texas Carbon Management Program is conducting a Front-End Engineering Design (FEED) for Piperazine with the Advanced Stripper™ (PZAS™) at a natural gas combined cycle power plant in west Texas. Here, this paper presents the design of the advanced stripper system with an emphasis on the selection of packing type, packing height, column diameter, and heat exchanger size, demonstrates the effect of ambient temperature swing on the regeneration energy requirement, and investigates two alternate process configurations that provide better energy performance than PZAS™. The design uses 2 stripper trains, and each train uses two cold cross exchangers, one hot cross exchanger, a stripper column, a CO 2 exchanger, and a condenser. Each column consists of two sections of random packing with RSR 2 packing at the top and RSR 3 packing at the bottom, with a total packed height of 7.5 m. The cold exchanger was designed with an NTU of 6, the hot exchanger with an NTU of 2, and the CO 2 exchanger with an NTU of 5. At 0.4 rich loading and 0.2 lean loading, this design resulted in a heat duty of 2.85 GJ/tonne CO 2 . The heat duty can vary up to 3.1 GJ/tonne CO 2 due to lower rich loading at higher summer temperature, but the absolute steam requirement is 8–15% lower in the summer. An alternate design, PZAS with hot rich bypass, is proposed, which can reduce the equivalent work of stripping by 1.5–3.5% compared to PZAS at low heat exchanger size, due to a reduction in stripper driving force. Using a hot rich bypass increases the vapor fraction of the total rich bypass stream from 0.3 to 1 mol% compared to using the warm rich bypass, which also contributes to a reduction in lost work in the column. PZAS with hot rich bypass outperforms PZAS in energy requirement below a packing height of 15 m, but fails to do so above 15 m of packing due to a column pinch that results in little change in LMTD of the column. PZAS with hot rich bypass has the potential to minimize capital cost in addition to reducing energy requirement as it requires less packing to strip CO 2 than PZAS and requires only one cross exchanger with 8 heat transfer units.

03 NATURAL GAS↗

Metallography and fuel cladding chemical interaction in fast flux test facility irradiated metallic U-10Zr MFF-3 and MFF-5 fuel pins

Abstract The Mechanistic Fuel Failure (MFF) series of metal fuel irradiations conducted in the Fast Flux Test Facility (FFTF) provides an important potential comparison between data generated in the Experimental Breeder Reactor (EBR-II) and that expected in a larger-scale fast reactor. The irradiations were the beginning tests to qualify U-10wt%Zr as a driver fuel for FFTF. The FFTF core, with a 91.4 cm tall fuel column and a chopped cosine neutron flux profile, operated with a peak cladding temperature at the top of the fuel column, but developed peak burnup at the centerline of the core. This places the peak fuel temperature midway between the core center and the top of fuel, lower in the fuel column than in previous EBR-II experiments that had a 32-cm height core. The MFF-3 and MFF-5 qualification assemblies operated in FFTF to >10 at% burnup, and performed very well with no cladding breaches. The MFF-3 assembly operated to 13.8 at% burnup with a peak inner cladding temperature of 643°C, and the MFF-5 assembly operated to 10.1 at% burnup with a peak inner cladding temperature of 651°C. Because of the very high operating temperatures for both the fuel and the cladding, data from the MFF assemblies are most comparable to the data obtained from the EBR-II X447 experiment, which experienced two pin breaches. The X447 breaches were strongly influenced by a large amount of fuel/cladding chemical interaction (FCCI). The MFF pins benefitted from different axial locations of high burnup and peak cladding temperature, which helped to reduce interdiffusion between rare earth fission products and stainless steel cladding. Post-irradiation examination evidence illustrates this advantage. Comparing other performance data of the long MFF pins to prior EBR-II test data, the MFF fuel inside the cladding grew less axially, and the gas release data did not reveal a definitive difference.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In situ nitrogen removal from leachate by bioreactor landfill with limited aeration

The feasibility of simultaneous nitrification and denitrification in a bioreactor landfill with limited aeration was assessed. Three column reactors, simulating bioreactor landfill operations under anaerobic condition (as reference), intermittent forced aeration and enhanced natural aeration were hence established, where aerated columns passed through two phases, i.e., fresh landfill and well-decomposed landfill. The experimental results show that limited aeration decreased nitrogen loadings of leachate distinctly in the fresh landfill. In the well-decomposed landfill, the NH{sub 4}{sup +}-N of the input leachate could be nitrified completely in the aerated landfill columns. The nitrifying loadings of the column cross section reached 7.9 g N/m{sup 2} d and 16.9 g N/m{sup 2} d in the simulated landfill columns of intermittent forced aeration and enhanced natural aeration, respectively. The denitrification was influenced by oxygen distribution in the landfill column. Intermittent existence of oxygen in the landfill with the intermittent forced aeration was favorable to denitrify the NO{sub 2}{sup -}-N and NO{sub 3}{sup -}-N, indicated by the high denitrification efficiency (>99%) under the condition of BOD{sub 5}/TN of more than 5.4 in leachate; locally persistent existence of oxygen in the landfill with enhanced natural aeration could limit the denitrification, indicated by relatively low denitrification efficiency of about 75% even when the BOD{sub 5}/TN in leachate had an average of 7.1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction Chromatographic Methods in the Sample Preparation Sequence for Thermal Ionization Mass Spectrometric Analysis of Plutonium Isotopes

A sample preparation sequence for actinide isotopic analysis by TIMS is described that includes column-based extraction chromatography as the first separation step, followed by anion exchange column separations. The sequence is designed to include a wet ashing step after the extraction chromatography to prevent any leached extractant or oxalic acid eluent reagents from interfering with subsequent separations, source preparation, or TIMS ionization. TEVA-resin and DGA-resin materials, containing extractants that consist only of C, N, O, and H atoms, were investigated for isolation of plutonium. Radiotracer level studies confirmed expected high yields from column-based separation procedures. Femtogram-level studies were carried out with TIMS detection, using multiple isotopic spikes through the separation sequence. Pu recoveries were 87% and 86% for TEVA- and DGA-resins separations respectively. The Pu recoveries from 400 {mu}L anion-exchange column separations were 89% and 93% for trial sequences incorporating TEVA and DGA-resin. Thus, a prior extraction chromatography step in the sequence did not interfere with the subsequent anion exchange separation when a simple wet ash step was carried out in between these column separations. The average measurement efficiency, for Pu, encompassing the chemical separation recoveries and the TIMS ionization efficiency, was 2.73 {+-} 0.77% (2-sigma) for the DGA-resin trials and 2.67 {+-} 0.54% for the TEVA-resin trials, compared to 3.41% and 2.37% (average 2.89%) for two spikes in the experimental set. These compare with an average measurement efficiency of 2.78 {+-} 1.70%, n = 33 from process benchmark analyses using Pu spikes processed through a sequence of oxalate precipitation, wet ash, iron hydroxide precipitation, and anion exchange column separations. We conclude that extraction chromatography can be a viable separation procedure as part of a multistep sequence for TIMS sample preparation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗