Wide range nuclear magnetic resonance detector using integrated circuits
Wide-range nuclear magnetic resonance probe design including integrated circuits, RF coil, and coaxial cable for use with high field cryogenic magnets
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Wide-range nuclear magnetic resonance probe design including integrated circuits, RF coil, and coaxial cable for use with high field cryogenic magnets
Astronaut electrode-amplifier helmet harness for cable and radiotelemetry acquisition of EEG, EGO, EMG and blood pressure data on noninterference basis
Hot-wire anemometer remote operation, discussing coaxial cable length, terminal connection and bridge current
Universal electrical connector for use with various types of electric cable, inserts, and pin styles is described. Connector may be used over variety of environmental conditions. Details of construction are discussed. Illustrations of connector are included.
Fabrication is described of waterproof electrical connector assembly for use with Teflon jacketed cables and constructed so that assembly will remain sealed under extreme environmental conditions. Conditions are specified as: pressure from vacuum to atmospheric; temperature from 280 K to 450 K; exposure to saturated steam; and steam suddenly introduced into vacuum.
Procedures for achieving electromagnetic compatibility in electronic and electrical equipment for aerospace ground stations are investigated. The application of shielding theory to good design is treated and standards of good practice are outlined for bonding, grounding, wiring, and cabling. Some aspects of filter design are explained, and suggestions are given for the application of filters to electronic and electrical equipment.
A digital computer program was developed which analyzes any radial rib antenna with ribs radiating from a central hub. The program has the capability for calculating the antenna surface contour (reversed pillowing effect), the optimum rib shape for minimizing the rms surface error, and the actual rms surface error. Rib deflection due to mesh tension and catenary cable tension can also be compensated for, and the pattern from which the mesh gores are cut can be determined.
Solid state detector technology was applied to the fabrication and testing of cadmium sulfide and silicon narrow slit detector/preamplifier subassemblies. Fabrication of the silicon detector and the cadmium sulfide detectors was accomplished by utilizing cadmium sulfide cells and silicon cells. Fabrication of the preamplifiers for both silicon and cadmium sulfide slit type detectors was also carried out. The design of these preamplifiers was adjusted to ascertain that the limiting noise source of the detector/preamplifier subassembly is the detector and the input cable.
Interdisciplinary research in needs analysis, communications technology studies, and systems synthesis is reported. Existing and planned educational telecommunications services are studied and library utilization of telecommunications is described. Preliminary estimates are presented of ranges of utilization of educational telecommunications services for 1975 and 1985; instructional and public television, computer-aided instruction, computing resources, and information resource sharing for various educational levels and purposes. Communications technology studies include transmission schemes for still-picture television, use of Gunn effect devices, and TV receiver front ends for direct satellite reception at 12 GHz. Two major studies in the systems synthesis project concern (1) organizational and administrative aspects of a large-scale instructional satellite system to be used with schools and (2) an analysis of future development of instructional television, with emphasis on the use of video tape recorders and cable television. A communications satellite system synthesis program developed for NASA is now operational on the university IBM 360-50 computer.
An example of advanced technology transfer from the Little Joe, Surveyor, Comsat, re-entry and Apollo age to everyday fire protection needs is presented. Utilizing the principle of sublimation cooling for thermostatic temperature control, the material meets a wide range of fire retardancy and heat transmission control requirements. Properties vary from flexible tape for conduits and electrical cables to rigid coatings for column protection, with a broad spectrum of sublimation temperatures available. The material can be applied in the field or in the factory, utilizing mass production techniques, yielding a product that is reliable, effective, widely available and low in cost.
The methods, techniques, and devices used in testing various electrical and electronic apparatus are presented. The items described range from semiconductor package leak detectors to automatic circuit analyzer and antenna simulators for system checkout. In many cases the approaches can result in considerable cost savings and improved quality control. The testing of various electronic components, assemblies, and systems; the testing of various electrical devices; and the testing of cables and connectors are explained.
A discrete capacitance liquid level system developed is specifically for slush hydrogen, but applicable to LOX, LN2, LH2, and RP1 without modification is described. The signal processing portion of the system is compatible with conventional liquid level sensors. Compatibility with slush hydrogen was achieved by designing the sensor with adequate spacing, while retaining the electrical characteristics of conventional sensors. Tests indicate excellent stability of the system over a temperature range of -20 C to 70 C for the circuit and to cryogenic temperatures of the sensor. The sensor was tested up to 40 g's rms random vibration with no damage to the sensor. Operation with 305 m of cable between the sensor and signal processor was demonstrated. It is concluded that this design is more than adequate for most flight and ground applications.
The structural testing is described of an Apollo Telescope Mount (ATM) cable arch and beam assembly, using static loads to simulate the critical conditions expected during transportation and launch of the ATM. All test objectives were met. Stress and deflection data show that the assembly is structurally adequate for use in the ATM.
Existing material technology was applied to the development of a collapsible transparent window suitable for manned spacecraft structures. The effort reported encompasses the evaluation of flame retardants intended for use in the window matrix polymer, evaluation of reinforcement angle which would allow for a twisting pantographing motion as the cylindrical window is mechanically collapsed upon itself, and evaluation of several reinforcement embedment methods. A fabrication technique was developed to produce a reinforced cylindrical space window of 45.7 cm diameter and 61.0 cm length. The basic technique involved the application of a clear film on a male-section mold; winding axial and girth reinforcements and vacuum casting the outer layer. The high-strength transparent window composite consisted of a polyether urethane matrix reinforced with an orthogonal pattern of black-coated carbon steel wire cable. A thin film of RTV silicone rubber was applied to both surfaces of the urethane. The flexibility, retraction system, and installation system are described.
A selection of new hand tools, modifications of existing tools, and techniques developed in the course of NASA research and development projects are presented. The items are presented in two sections: tools for cable and connector applications, and tools for welding applications. Safety is emphasized, together with ease of operation and use in restricted areas or hazardous environments. The discussions are directed primarily toward the technician engaged in assembly or maintenance of mechanical or electrical equipment.
The document covers interconnecting wire harnesses defined in the design standard, including type 8, flat conductor cable. Volume breadth covers installations of groups of harnesses in a major assembly and the associated post installation inspections and electrical tests. Knowledge gained through experience on the Saturn 5 program coupled with recent advances in techniques, materials, and processes was incorporated into this document.
This paper describes a complete electroencephalographic acquisition and transmission system, designed to meet the needs of a large hospital with multiple critical care patient monitoring units. The system provides rapid and prolonged access to a centralized recording and computing area from remote locations within the hospital complex, and from locations in other hospitals and other cities. The system includes quick-on electrode caps, amplifier units and cable transmission for access from within the hospital, and EEG digitization and telephone transmission for access from other hospitals or cities.
Results of an experimental study of electrical losses in superconductor magnets. Preliminary 60-Hz ac loss data are presented for coils constructed of Nb3Sn ribbon, Nb-Ti cable, and multifilament Nb-Ti. Losses have been measured for different size coils up to approximately 20 cm in diameter. Of the conductor types tested, Nb3Sn ribbon has the lowest losses for ac operation. In Nb3Sn-ribbon coils of different sizes, the loss per unit length of conductor is shown to decrease with a decrease in the rate of change of current and to increase, in general, with increase in coil size. An important aspect of the study is the high degree of repeatability of the data.