Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Implementation of CMFD Acceleration Scheme in PROTEUS-MOC

The PROTEUS-MOC code is a three-dimensional (3D) transport code, which is being developed at Argonne National Laboratory under the DOE-NE's Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. It provides a fully consistent 3D discretization of the transport equation by combining the two-dimensional (2D) method of characteristics (MOC) for the planar direction with the discontinuous Galerkin method for the treatment of the axial variable. PROTEUS-MOC uses the unstructured finite element method (FEM) and thus allows the explicit representation of any extruded geometries. It also has a capability of massively parallel computation in energy group, angle, plane, and space using a top-level GMRES linear algebra solver. For parallel computation in space, it uses an unstructured domain decomposition by adapting METIS. The computational burden for direct heterogeneous core calculations based on unstructured geometries is excessive for practical reactor problems, and hence it is essential to implement an efficient acceleration scheme in PROTEUS-MOC. Recently, the coarse mesh finite difference (CMFD) method, which was originally applied to the nodal diffusion methods, has been successfully applied to the MOC transport solvers, resulting in a remarkable reduction in the number of fission source iterations. In addition, a modified CMFD method has been developed to overcome the limitation of the conventional CMFD that is applicable only to neutronics solvers with a conservative discretization. This CMFD method was derived to be consistent with the FEM, which is based on a nonconservative discretization. In this method, the neutron balance in each coarse mesh is enforced by introducing a pseudo absorption cross section (PAXS), and the well-established alternating solution process of CMFD and transport calculations is employed to accelerate source convergence. This modified CMFD acceleration scheme was adopted in PROTEUS-MOC to accelerate the fission source iteration. Pin-cell and assembly based CMFD schemes have been implemented by defining individual pin cells or assemblies as a coarse mesh. For this, an algorithm to map the finite elements to coarse meshes was developed, and the routines were developed to determine the coupling coefficients and PAXS of the CMFD equations from the transport solution. Preliminary performance tests were carried out using the C5G7 benchmark problem. This paper presents the main features of this CMFD acceleration scheme and the preliminary test results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of cell-based diffusion acceleration for the slice balance approach

In this work, we perform analysis on the use of cell-based diffusion acceleration methodologies to accelerate the convergence of transport solutions discretized with the slice balance approach (SBA) on unstructured polygonal grids.We investigated both linear diffusion synthetic acceleration (DSA) and non linear diffusion acceleration (NDA), including its partial-current variant (pNDA). DSA and NDA were both shown to diverge for intermediate ranges of mesh optical thicknesses. However, pNDA and Krylov methods like GMRES and Broyden stabilized the acceleration schemes, including problems with degenerate cells formed by mesh refinement. (author)

42 ENGINEERING↗

PIP-II Particle Accelerator Project

The PIP-II project is an essential upgrade of Fermilab’s particle accelerator complex. Groundbreaking occurred in March 2019. The upgrade will enable Fermilab’s accelerators to generate an unprecedented stream of neutrinos—subtle, subatomic particles that could hold the key to understanding the universe’s evolution—by creating the world’s most intense high-energy neutrino beams. This capability positions Fermilab to be the world leader in accelerator-based neutrino research. It enables the scientific program for the international, Fermilab-hosted Deep Underground Neutrino Experiment (DUNE) and Long-Baseline Neutrino Facility (LBNF). The key to PIP-II is power. When the PIP-II project is complete, Fermilab will be able to generate proton beams greater than 1 megawatt—60 percent higher than current capabilities. These powerful beams of protons will in turn create intense beams of neutrinos. Future PIP-II upgrades will triple the lab’s current beam power. PIP-II’s high-intensity proton beams will provide a flexible platform for the long-term future of the Fermilab accelerator complex and the U.S. accelerator-based particle physics program.

Fermilab, Fermilab↗

On Reproducibility of Collective Acceleration of Protons in a Plasma-Anode Diode System

The article deals with the investigation of the conditions of reproducibility of the results of collective acceleration of protons in a high-current relativistic electron beam of nanosecond duration passing through a plasma bunch. A quantitative criterion of reproducibility in the system of an anode with a dielectric insert and a cylindrical cathode was the neutron yield in a nuclear reaction with the threshold about 2 MeV, which was measured by a silver-activated detector after each operation of the accelerator. Generation of an azimuthally-homogeneous electron beam and plasma in the area of the dielectric insert on the anode and the use of lenses in the region of electron beam drift resulted in the stabilization of the accelerating process. After optimization, the neutron yield scatter in a series of 30 pulses was at the level ±5% of the average value, which corresponded to the accelerated proton energy scatter ±3%. The conditions of best reproducibility coincided with those where the main group of protons reached their maximum values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visualization of the unburned gas flow field ahead of an accelerating flame in an obstructed square channel

The effect of blockage ratio on the early phase of the flame acceleration process was investigated in an obstructed square cross-section channel. Flame acceleration was promoted by an array of top-and bottom-surface mounted obstacles that were distributed along the entire channel length at an equal spacing corresponding to one channel height. It was determined that flame acceleration is more pronounced for higher blockage obstacles during the initial stage of flame acceleration up to a flame velocity below the speed of sound of the reactants. The progression of the flame shape and flame area was determined by constructing a series of three-dimensional flame surface models using synchronized orthogonal schlieren images. A novel schlieren based photographic technique was used to visualize the unburned gas flow field ahead of the flame front. A small amount of helium gas is injected into the channel before ignition, and the evolution of the helium diluted unburned gas pocket is tracked simultaneously with the flame front. Using this technique the formation of a vortex downstream of each obstacle was observed. The size of the vortex increases with time until it reaches the channel wall and completely spans the distance between adjacent obstacles. A shear layer develops separating the core flow from the recirculation zone between the obstacles. The evolution of oscillations in centerline flame velocity is discussed in the context of the development of these flow structures in the unburned gas. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linear Accelerator-Based Intensity-Modulated Total Marrow Irradiation Technique for Treatment of Hematologic Malignancies: A Dosimetric Feasibility Study

Purpose: To investigate the dosimetric feasibility of linear accelerator-based intensity-modulated total marrow irradiation (IM-TMI) in patients with hematologic malignancies. Methods and Materials: Linear accelerator-based IM-TMI treatment planning was performed for 9 patients using the Eclipse treatment planning system. The planning target volume (PTV) consisted of all the bones in the body from the head to the mid-femur, except for the forearms and hands. Organs at risk (OAR) to be spared included the lungs, heart, liver, kidneys, brain, eyes, oral cavity, and bowel and were contoured by a physician on the axial computed tomography images. The three-isocenter technique previously developed by our group was used for treatment planning. We developed and used a common dose-volume objective method to reduce the planning time and planner subjectivity in the treatment planning process. Results: A 95% PTV coverage with the 99% of the prescribed dose of 12 Gy was achieved for all nine patients. The average dose reduction in OAR ranged from 19% for the lungs to 68% for the lenses. The common dose-volume objective method decreased the planning time by an average of 35% and reduced the inter- and intra- planner subjectivity. Conclusion: The results from the present study suggest that the linear accelerator-based IM-TMI technique is clinically feasible. We have demonstrated that linear accelerator-based IM-TMI plans with good PTV coverage and improved OAR sparing can be obtained within a clinically reasonable time using the common dose-volume objective method proposed in the present study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward laser ablation Accelerator Mass Spectrometry of actinides

A project to measure neutron capture cross sections of a number of actinides in a reactor environment by Accelerator Mass Spectrometry (AMS) at the ATLAS facility of Argonne National Laboratory is underway. This project will require the precise and accurate measurement of produced actinide isotopes in many (>30) samples irradiated in the Advanced Test Reactor at Idaho National Laboratory with neutron fluxes having different energy distributions. The AMS technique at ATLAS is based on production of highlycharged positive ions in an electron cyclotron resonance (ECR) ion source followed by acceleration in the ATLAS linac and mass-to-charge (m/q) measurement at the focus of the Fragment Mass Analyzer. Laser ablation was selected as the method of feeding the actinide material into the ion source because we expect it will have higher efficiency and lower chamber contamination than either the oven or sputtering techniques, because of a much narrower angular distribution of emitted material. In addition, a new multi-sample holder/changer to allow quick change between samples and a computer-controlled routine allowing fast tuning of the accelerator for different beams, are being developed. An initial test run studying backgrounds, detector response, and accelerator scaling repeatability was conducted in December 2010. The project design, schedule, and results of the initial test run to study backgrounds are discussed.

99 GENERAL AND MISCELLANEOUS↗

Positive-ion accelerator mass spectrometry at ATLAS: Peaks and pits

Electron Cyclotron Resonance (ECR) ion sources and the production of multiple-charge positive ions with high efficiency in combination with a heavy-ion accelerator have opened the way to an alternative and complementary version of accelerator mass spectrometry (AMS). A notable strength of positive-ion over traditional AMS is the capability of ultra-high sensitivity detection of radioactive isotopes of noble gases, in particular 37 Ar (t 1/2 = 35 d) and 39 Ar (269 y). The complete dissociation of molecular ions in the ECR and in particular of hydride ions of neighboring stable isotopes results in superior isotopic separation. However, the use of high charge states, necessary for acceleration to high energy, entails the existence of severe transmission degeneracies with stable ions having nearly equal mass-to-charge ratios, in addition to that of stable isobaric ions. Separation or discrimination of these parasitic ions require powerful and sophisticated dispersive systems at detection stage. In conclusion, we review here work performed and in progress at the ATLAS facility of Argonne National Laboratory (ANL) where an ECR ion source, a Radio-Frequency Quadrupole (RFQ), a superconducting linear accelerator and a Gas-Filled Magnet (GFM) are used as an AMS setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an accelerator-based neutron source to prototype Mo-99 production, Part II: A liquid LBE loop under a high vacuum

To provide US domestic supply of Mo-99 without using high-enriched uranium (HEU), a subcritical uranium target assembly (UTA) is irradiated by an accelerator-based neutron source to create Mo-99 through fission. Part I of this work discusses the design of a liquid lead–bismuth eutectic (LBE) windowless target for an accelerator-based neutron source development. Part II discusses how to couple this windowless target to an accelerator operating at an ultra-high vacuum and the subcritical UTA cooled by water at room temperature. Due to the windowless design of the target, the liquid LBE flow shares an ultra-high vacuum (<1.3 × 10 -7 Pa or 10 -9 Torr) space with the accelerator. As a result of this shared vacuum space, the LBE system must operate at a high vacuum (10 -3 ~10 -6 Pa or 10 -5 ~10 -8 Torr). A magnetic rotary motion feedthrough unit utilizes magnetic fluid to allow rotation of the pump while maintaining a high vacuum environment. Prior to testing the LBE system under vacuum, a pump curve measurement is performed to estimate flowrate in the system. This measurement also generates data on orifice loss coefficients, which are compared to correlations in literature. The second experiment investigates vacuum level in the LBE system during operation. High vacuum is maintained (10 -3 ~10 -5 Pa or 10 -5 ~10 -7 Torr) during system operation, and a residual gas analyzer (RGA) scan shows that partial pressures of residual gases in the LBE system lower over the duration of LBE system operations. The third experiment investigates the gravity driven liquid LBE flowing out of the target chamber in the return line, which is partially full. If the liquid LBE is not drained quickly enough, flooding in the target chamber could occur. The coefficient n in the Manning equation is found to be around 0.008 s/m 1/3 . The last experiment performed is a demonstration that a vacuum jacket could provide sufficient thermal insulation to allow coupling between 300 °C LBE loop and a water tank at room temperature. In conclusion, the results from these experiments have influenced the development of the neutron source for the future commercial scale Mo-99 production system.

43 PARTICLE ACCELERATORS↗

Proposed new accelerator design for homeland security x-ray applications

Two goals for security scanning of cargo and freight are the ability to determine the type of material that is being imaged, and to do so at low radiation dose. One commonly used technique to determine the effective Z of the cargo is dual-energy imaging, i.e. imaging with different x-ray energy spectra. Another technique uses the fact that the transmitted x-ray spectrum itself also depends on the effective Z. Spectroscopy is difficult because the energy of individual x rays needs to be measured in a very high count-rate environment. Typical accelerators for security applications offer large but short bursts of x-rays, suitable for current-mode integrated imaging. In order to perform x-ray spectroscopy, a new accelerator design is desired that has the following features: 1) increased duty factor in order to spread out the arrival of x-rays at the detector array over time; 2) x-ray intensity modulation from one delivered pulse to the next by adjusting the accelerator electron beam instantaneous current so as to deliver adequate signal without saturating the spectroscopic detector; and 3) the capability to direct the (forward peaked) x-ray intensity towards high-attenuation areas in the cargo (“fan-beam-steering”). Current sources are capable of 0.1% duty factor, although usually they are operated at significantly lower duty factors (~0.04%), but duty factors in the range 0.4-1.0% are desired. The higher duty factor can be accomplished, e.g., by moving from 300 pulses per second (pps) to 1000 pps and/or increasing the pulse duration from a typical 4 μs to 10 μs. This paper describes initial R&D to examine cost effective modifications that could be performed on a typical accelerator for these purposes, as well as R&D for fan-beam steering.

43 PARTICLE ACCELERATORS↗

Guiding and Ionization Blueshift in Ablative Capillary Waveguide Accelerators

Laser wakefield acceleration (LWFA) in plasmas has been demonstrated with gradients which are orders of magnitude greater than the limit on conventional Radio Frequency accelerators. However, the acceleration length is limited by two factors, the dephasing length and the Rayleigh range of the laser pulse. Dephasing length is the distance in which electrons overtake the laser pulse and can be increased by decreasing plasma density. Alternatively the interaction length can be extended by orders of magnitude by using ablative wall discharge capillary targets, in which a plasma is preformed with a transverse density profile capable of guiding the focused laser. We have demonstrated guiding of high intensity laser pulses from the HERCULES laser over 3 cm for powers up to 35 TW. The quality of the laser spot can be retained and the intensity remains high even at the exit of the capillary. The transmitted laser spectrum shows blueshifting due to field ionization by the laser pulse. This ionization might enhance electron injection at low electron density for LWFA GeV accelerators. The field ionization affects carbon atoms and ions from the ablated capillary, which are not present in hydrogen-filled capillaries. This creates an additional challenge to guiding compared to hydrogen-filled capillaries. However, the setup and materials are easier to come by. The use of these capillary targets may also be of interest to other high intensity laser-plasma interactions requiring long interaction lengths such as high harmonic generation from gases and plasmas, or x-ray lasing in underdense plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Fast, Electromagnetically Driven Supersonic Gas Jet Target For Laser Wakefield Acceleration

Laser-Wakefield acceleration (LWFA) promises electron accelerators with unprecedented electric field gradients. Gas jets and gas-filled capillary discharge waveguides are two primary targets of choice for LWFA. Present gas jets have lengths of only 2-4 mm at densities of 1-4x10{sup 19} /cm{sup 3}, sufficient for self-trapping and acceleration to energies up to {approx}150 MeV. While 3 cm capillary structures have been used to accelerate beams up to 1 GeV, gas jets require a well-collimated beam that is {>=}10 mm in length and <500 {mu}m in width, with a tunable gas density profile to optimize the LWFA process. This paper describes the design of an electromagnetically driven, fast supersonic gas valve that opens in <100 {mu}s, closes in <500 {mu}s and can operate at pressures beyond 1000 psia. The motion of the valve seat (flyer plate) is measured using a laser probe and compared with predictions of a model. The valve design is based on an optimization of many parameters: flyer plate mass and durability, driver bank speed and stored energy for high rep-rate (>10 Hz) operation, return spring non-linearity and materials selection for various components. Optimization of the valve dynamics and preliminary designs of the supersonic flow patterns are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics design of a 100 keV acceleration grid system for the diagnostic neutral beam for international tokamak experimental reactor

This paper describes the physics design of a 100 keV, 60 A H{sup -} accelerator for the diagnostic neutral beam (DNB) for international tokamak experimental reactor (ITER). The accelerator is a three grid system comprising of 1280 apertures, grouped in 16 groups with 80 apertures per beam group. Several computer codes have been used to optimize the design which follows the same philosophy as the ITER Design Description Document (DDD) 5.3 and the 1 MeV heating and current drive beam line [R. Hemsworth, H. Decamps, J. Graceffa, B. Schunke, M. Tanaka, M. Dremel, A. Tanga, H. P. L. De Esch, F. Geli, J. Milnes, T. Inoue, D. Marcuzzi, P. Sonato, and P. Zaccaria, Nucl. Fusion 49, 045006 (2009)]. The aperture shapes, intergrid distances, and the extractor voltage have been optimized to minimize the beamlet divergence. To suppress the acceleration of coextracted electrons, permanent magnets have been incorporated in the extraction grid, downstream of the cooling water channels. The electron power loads on the extractor and the grounded grids have been calculated assuming 1 coextracted electron per ion. The beamlet divergence is calculated to be 4 mrad. At present the design for the filter field of the RF based ion sources for ITER is not fixed, therefore a few configurations of the same have been considered. Their effect on the transmission of the electrons and beams through the accelerator has been studied. The OPERA-3D code has been used to estimate the aperture offset steering constant of the grounded grid and the extraction grid, the space charge interaction between the beamlets and the kerb design required to compensate for this interaction. All beamlets in the DNB must be focused to a single point in the duct, 20.665 m from the grounded grid, and the required geometrical aimings and aperture offsets have been calculated.

43 PARTICLE ACCELERATORS↗

Supra-bubble regime for laser acceleration of cold electron beams in tenuous plasma

Relativistic electrons can be accelerated by an ultraintense laser pulse in the 'supra-bubble' regime, that is, in the blow-out regime ahead of the plasma bubble (as opposed to the conventional method, when particles remain inside the bubble). The acceleration is caused by the ponderomotive force of the pulse, via the so-called snow-plow mechanism. The maximum energy gain, DELTAgammaapproxgamma{sub g}a, is attained when the particle Lorentz factor gamma is initially about gamma{sub g}/a, where gamma{sub g} is the pulse group speed Lorentz factor, and a is the laser parameter, proportional to the laser field amplitude. The scheme operates at a < or approx. gamma{sub g}, yielding DELTAgamma of up to that via wakefield acceleration for the same plasma and laser parameters, DELTAgammaapproxgamma{sub g}{sup 2}. The interaction length is shorter than that for the wakefield mechanism but grows with the particle energy, hindering acceleration in multiple stages.

43 PARTICLE ACCELERATORS↗

Simulation of particle acceleration in the PLASMONX project

In this paper I will present some numerical studies and parameter scans performed with the electromagnetic, rela-tivistic, fully-self consistent particle-in-cell (PIC) code ALaDyn (Acceleration by LAser and DYNamics of charged particles), concerning electron acceleration via plasma waves in the framework of the INFN-PLASMONX (PLASma acceleration and MONochromatic X-ray production) project. In particular I will focus on the modelling of the SITE (Self Injection Test Experiment) which will be a relevant part of the commissioning of the FLAME laser. Some issues related to the quality of the accelerated bunch will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Charge, Multi-MeV Electron Bunches Accelerated in Moderate Laser-Plasma Interaction Regime

Experiments, and simulations have shown that quasi-monoenergetic electron bunches can be accelerated from the background electron plasma population up to relativistic energies. Theoretical work indicated that with a proper choice of laser, plasma, and injection parameters the acceleration of electron bunches with small energy spread and short bunch length can occur in moderate intensity regime. Here we present the results of an experiment on electron acceleration carried out at the IPCF-CNR's Intense Laser Irradiation Laboratory in Pisa, within a wide national collaboration leaded by INFN named PLASMONX. High-charge, multi-MeV electron bunches were accelerated in moderated intensity regime by focusing the laser beam on a laminar gaseous target produced by a supersonic gas-jet. The laser-gas interaction was studied via interferometry, and Thomson scattering while the electron bunches were detected and characterised using a phosphor screen coupled with a magnetic spectrometer or a dosimetric detector. In some cases highly collimated electron bunches with moderate energy spread were observed, while the generation of high-charge, MeV energies electron bunches were obtained with high reproducibility for each gases tested.

43 PARTICLE ACCELERATORS↗

Particle Accelerator Applications: Ion and Electron Irradiation in Materials Science, Biology and Medicine

Although the developments of particle accelerators are devoted to basic study of matter constituents, since the beginning these machines have been applied with different purposes in many areas also. Today particle accelerators are essential instruments for science and technology. This work presents an overview of the main application for direct particle irradiation with accelerator in material science, biology and medicine. They are used for material synthesis by ion implantation and charged particle irradiation; to make coatings and micromachining; to characterize broad kind of samples by ion beam analysis techniques; as mass spectrometers for atomic isotopes determination. In biomedicine the accelerators are applied for the study of effects by charged particles on cells. In medicine the radiotherapy by electron irradiation is widely used, while hadrontherapy is still under development. Also, they are necessary for short life radioisotopes production required in radiodiagnostic.

36 MATERIALS SCIENCE↗

The Scanning Electron Microscope As An Accelerator For The Undergraduate Advanced Physics Laboratory

Few universities or colleges have an accelerator for use with advanced physics laboratories, but many of these institutions have a scanning electron microscope (SEM) on site, often in the biology department. As an accelerator for the undergraduate, advanced physics laboratory, the SEM is an excellent substitute for an ion accelerator. Although there are no nuclear physics experiments that can be performed with a typical 30 kV SEM, there is an opportunity for experimental work on accelerator physics, atomic physics, electron-solid interactions, and the basics of modern e-beam lithography.

99 GENERAL AND MISCELLANEOUS↗