Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Recognition of binary x-ray systems utilizing the doppler effect

The possibility of recognizing the duality of a single class of X-ray systems utilizing the Doppler effect is studied. The procedure is based on the presence of a period which coincides with the orbital period at the intensity of the radiation in a fixed energy interval of the X-ray component of a binary system.

Novak, B. L.↗

Human perception of ionizing radiation

Here, in this work, we address the question of whether humans can perceive ionizing radiation. We conducted a thorough review of the clinical and experimental literature related to ionizing radiation, with a focus on its acute effects. Specifically, we examined the three domains of X-ray perception found in animals (abdominal, olfactory, and retinal), which led us to instances of ionizing radiation-induced hearing and taste sensory phenomena in humans thus suggesting that humans can perceive X-rays across various sensory modalities via multiple mechanisms. We also analyzed literature to understand the mechanisms associated with reported symptoms, this led us to the concept of radiomodulation, an understudied modulatory effect of sub-ablative ionizing radiation doses on neurons. Based on this review of the literature we propose the hypothesis that a significant radiomodulation mechanism is the formation of reactive oxygen species from radiolysis which activates immune and sensory signal transduction mechanisms specifically related to the redox activity in TRP and K+ channels. Additionally, we find evidence to support the previous claims of perception stemming from Cherenkov radiation and ozone production which are perceived using canonical sensory modalities. Finally, for we provide a concise summary of the applications of ionizing radiation in clinical imaging and therapy, as well as prospects for future developments of radiation technologies for biomedical and fundamental research.

Ionizing radiation↗

A combined MeV-neutron and x-ray source for the National Ignition Facility

We report that in support of future radiation-effects testing, a combined environment source has been developed for the National Ignition Facility (NIF), utilizing both NIF’s long-pulse beams, and the Advanced Radiographic Capability (ARC) short pulse lasers. First, ARC was used to illuminate a gold foil at high-intensity, generating a significant x-ray signal > 1 MeV. This was followed by NIF 10 ns later to implode an exploding pusher target filled with fusionable gas for neutron generation. The neutron and x-ray bursts were incident onto a retrievable, close-standoff diagnostic snout. With separate control over both neutron and x-ray emission, the platform allows for tailored photon and neutron fluences and timing on a recoverable test sample. The platform exceeded its initial fluence goals, demonstrating a neutron fluence of 2.3 ×10 13 n/cm 2 and an x-ray dose of 7 krad.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The hard X-ray emission spectra from accretion columns in intermediate polars

We consider the hard (greater than 2 keV) X-ray emission from accretion columns in an intermediate polar system, GK Per, using a simple settling solution. The rate of photon emission per logarithmic energy interval can be fitted with a power law, E(exp -gamma), with gamma approximately 2.0, in agreement with observations. This index is only weakly dependent on the mass accretion rate, dot-M, for dot-M in the range of a few times 10(exp 16-18) g/s. The peak energy of the photon spectra (after photoelectric absorption) is expected to be E(sub p) approximately (5 keV) gamma(exp -1/3) (N(sub H)/10(exp 23)/sq cm)(exp 1/3) where N(sub H) is the hydrogen column density along the line of sight. The observed spectra of GK Per and possibly of V1223 Sgr suggest N(sub H) approximately 10(exp 23)/sq cm. This large N(sub H) may be due to partially ionized preshock column material. Alternatively, we also consider absorption by the cool outer parts of an accretion disk. In this case the photoelectric absorption depth in the disk is a sensitive function of inclination. For GK Per the required inclination is approximately 83 deg. For mass accretion rates larger than a critical rate of approximately 10(exp 18) g/s, X-ray emission from the column accretion is significantly affected by radiation drag. Although the mass accretion rate increases dramatically during outbursts, the observed hard (greater than 2 keV) X-ray luminosity will not rise proportionately. The slope and peak energy of the outburst spectra are only weakly affected. We conclude that the observed X-ray spectra can be explained by this simple analytic solution and that the production of hard X-rays from the accretion shock at the magnetic poles in the intermediate polars is in general agreement with the observations. However, since the X-ray emission and absorption depend on the mass accretion rate in a complicated manner, observed hard X-ray luminosities (greater than 2 keV) are not a good indicator of the mass accretion rate in the X-ray emitting regions.

Yi, Insu↗

Evidence of Morphological Change in Sulfur Cathodes upon Irradiation by Synchrotron X-rays

While the development of lithium–sulfur battery cathodes has benefited substantially from the use of in situ and ex situ X-ray absorption studies, the degree of undesired influence from synchrotron radiation has not been studied. In this study, we present evidence of severe beam damage on sulfur cathodes under irradiation by synchrotron X-rays. Specifically, X-ray fluorescence mapping with relatively low dosage was conducted to observe the morphological changes after conducting X-ray absorption spectroscopy (XAS). Under open-circuit conditions, the morphology of the sulfur spontaneously changes and tends to migrate out of the region of XAS sampling. Our work indicates that effort should be placed in first obtaining a no-change/stable open-circuit baseline when attempting to conduct in operando studies of lithium–sulfur batteries using synchrotron radiation with an energy of <7.7 keV and a flux of >6 × 10 12 photons s –1 .

25 ENERGY STORAGE↗

High gas throughput SOLPS-ITER simulations extending the ITER database to strong detachment

Abstract SOLPS-ITER simulations performed for Q DT = 10, P SOL = 100 MW burning plasmas on ITER extend the existing database to high values of separatrix averaged neon impurity concentration (⟨ c Ne ⟩ ≈ 6%) and divertor neutral pressure (⟨ p div ⟩ > 25 Pa) in order to determine the heat flux mitigation capability of these scenarios and whether strongly detached states are accessible. In the existing database of ITER simulations, the level of detachment was limited to cases where the integral ion flux to the outer target was greater than 80% of the value at rollover, with the impurity radiation localized near the target. With the possibility of narrow heat flux channels and increased deposited power due to tile shaping, it is important to explore operation at a higher degree of detachment. Two series of simulations were explored to extend the database of SOLPS simulations. By increasing the deuterium and neon puff rates proportionally, the peak divertor energy flux ( q ⊥,max ) is decreased from 5 to 3 MW m −2 while ⟨ p div ⟩ increased from 11 to 27 Pa. By increasing only the neon puff, q ⊥, max can be reduced to <1MW m −2 while ⟨ p div ⟩ is maintained at ∼ 11 Pa. As the neon puff level is increased, the position of the impurity radiation peak is shifted towards the X-point. At the highest neon puff levels with steady-state solutions, the electron temperature is reduced below 1 eV across 50 cm of each divertor target. The new cases extend previously observed tight relationships in power and momentum loss factors to low electron temperature improving their utility for highly detached regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Manufacturability-based optical design optimization for advanced Kirkpatrick–Baez X-ray focusing mirrors

The advanced Kirkpatrick–Baez (AKB) mirror setup is an effective and compelling solution to provide stable X-ray nano-focusing for synchrotron radiation or free-electron laser beamlines. We propose an AKB mirror design optimization approach to mitigate the difficulties associated with mirror fabrication by minimizing the total slope ranges of the four curved mirrors while achieving the expected focusing performance. In the optimization, we have considered geometry constraints to ensure the beam acceptance with the required clear aperture, the diffraction-limited focal size with the adequate numerical aperture, and the desired mirror gaps for adjustment and the necessary working distance for the sample stage. Additionally, practical constraints linked to mirror metrology and fabrication, such as mirror length limits and curvature uncertainty in measurement, are taken into account. Furthermore, progressive objective optimization eliminates the need for any initial guess, fully automating the AKB optimization process. This approach facilitates the development of an elegant Wolter-I or Wolter-III type AKB design solution that satisfies these multiple constraints. In cases where constraints cannot be simultaneously satisfied, the optimization results provide valuable insights into areas where trade-offs need to be considered. Simulations with ray tracing and wavefront propagation validate the optimized AKB design showing high tolerance to the beam incident angle.

36 MATERIALS SCIENCE↗

X-ray structure of the Cygnus Loop.

X-ray emission from the Cygnus Loop was observed in the energy region around 0.2 to 1 keV with a collector that focused X-rays along one dimension while scanning across the nebula. The total integrated intensity is 13 nanoerg per square centimeter per second. The one-dimensional X-ray structure has the same angular size - about 3 degrees - as the outermost boundaries of the optical filaments. There is no increase in X-ray emission at the center of the nebula nor at the strong feature that is seen in certain radio maps. The X-ray spectrum is consistent with thermal radiation from a hot plasma at a temperature of about 4 million K.

Gorenstein, P.↗

On the properties of matter in neutron stars

A qualitative description of the interior of a neutron star is presented, giving attention also to the validity of the 'isotropic fluid' approximation. The atmosphere and surface of a neutron star are considered together with aspects concerning nuclear and solid state physics in the crust, the liquid interior, the hyperon core, neutron star models, and pulsar observations. Accretion processes are also investigated, taking into account such topics as the Eddington limit, accretion rates, the death of pulsars, changes of the surface composition of neutron stars by accretion, questions of X-ray emission, and aspects of gamma radiation emission.

Boerner, G.↗

X-ray structure of the Cygnus loop

An X-ray surface brightness map of the Cygnus Loop in the energy range 0.15-0.85 keV is presented. The X-ray distribution is compared with the optical and radio pictures of the Loop. The location of the center of the supernova shell as derived from the X-ray data is in excellent agreement with the apparent optical and radio centers. We obtain a mean diameter for the X-ray shell of 2.75 (+ or - 0.2) deg. The X-ray spectral data yield a characteristic thermal temperature averaged over the Loop of 2.9 million (+ or - 1.5 million) K. We have calculated anew X-ray parameters for adiabatic blast waves using X-ray production spectra which include line radiation. These parameters are compared with the results of the present experiment. An age of 18,000 years, initial blast energy equal to 3 times 10 to the 50-th power ergs, and ambient interstellar density of 0.25 per cu cm are found.

Rappaport, S.↗

Nuclear Science Symposium, 21st, Scintillation and Semiconductor Counter Symposium, 14th, and Nuclear Power Systems Symposium, 6th, Washington, D.C., December 11-13, 1974, Proceedings

Papers are presented dealing with latest advances in the design of scintillation counters, semiconductor radiation detectors, gas and position sensitive radiation detectors, and the application of these detectors in biomedicine, satellite instrumentation, and environmental and reactor instrumentation. Some of the topics covered include entopistic scintillators, neutron spectrometry by diamond detector for nuclear radiation, the spherical drift chamber for X-ray imaging applications, CdTe detectors in radioimmunoassay analysis, CAMAC and NIM systems in the space program, a closed loop threshold calibrator for pulse height discriminators, an oriented graphite X-ray diffraction telescope, design of a continuous digital-output environmental radon monitor, and the optimization of nanosecond fission ion chambers for reactor physics. Individual items are announced in this issue.

Source record↗

Results of ionization measurements in the middle atmosphere

Positive-ion electrical-conductivity measurements, which are now performed with 4-cm diameter meteorological rocket payloads, provide a simple means of monitoring the NO concentration in the mesosphere, as well as the ionization variability. A wavelike dynamical structure is observed at low latitudes. Parachute-borne Gerdien mobility analyzers show, in addition, ion mobility spectra which spread from much greater to much less than that expected for simple gas-phase ions in the mesosphere and also indicate an ion clustering chain in the stratosphere. Large particulate ions apparently form in the daytime and grow very large at night. An instrument combining the mobility analyzer with a flashing source of ionizing radiation could be used as an NO(x) spectrometer.

Croskey, C. L.↗

Soft X-ray spectrum of a hot plasma

The spectrum of radiation emitted by a hot optically thin plasma with abundances and equilibrium ionization balance appropriate to interstellar conditions has been calculated. The results at wavelengths shorter than 200 A are discussed for material in the electron-temperature range from 160,000 to 100 million K.

Raymond, J. C.↗

Solar energetic photon transients - 50 keV-100 MeV

The observed properties of solar transient photon impulses between a few keV and 100 MeV recorded by the SMM are compared and reasons for continued monitoring of solar photon transients are discussed. Various solar flare events observed are reviewed, along with gamma ray measurements. It is calculated that the emission of energetic photons is due to ion and electron interactions with matter, with both species undergoing acceleration at close time intervals. The gamma ray events and microwave emissions showed time structures similar to previously recorded X ray emissions. Bursts of all three radiation types have displayed a quasi-periodicity of less than 10 sec. Data on the 2.223 MeV neutron capture line have shown a decay in line intensity to take about 50 sec, consistent with Monte Carlo calculation for a He-3/H abundance of 0.00005.

Chupp, E. L.↗

Space Radiation Effects on Graphite-Epoxy Composite Materials

Radiation effects on engineering properties, dimensional stability, and chemistry on state of the art composite systems were characterized. T300/934 graphite-epoxy composite was subjected to 1.0 MeV electron radiation for a total dose of 1.0 x 10(10) rads at a rate of 5.0 x 10(7) rads/hour. This simulates a worst case exposure equivalent to 30 years in space. Mechanical testing was performed on he 4-ply unidirectional laminates over the temperature range of -250 F (116K) to +250 F (394K). A complete set of in-plane tensile elastic and strength properties were obtained (E sub 1, E sub 2, nu sub 12, G sub 12, X sub T, Y sub T, and S). In addition electron microscopy was used to study and analyze the fracture surfaces of all specimens tested. Results indicate that little difference in properties is noted at room temperature, but significant differences are observed at both low and elevated temperatures.

Milkovich, S. M.↗

Microwave signature of thick-target electron beams in solar flares

The steady-state behavior of a flux of nonthermal electrons injected into a fully ionized thick target is examined. Owing to the (inverse square) energy dependence of the Coulomb collisional cross section, it is found that injected electron distributions that are monotonically decreasing functions of electron energy develop at finite depths into distributions that have 'humps' in velocity space; the electron energy corresponding to the hump correlates with the overlying particle column density to the target. This results in a two-stream unstable situation. The distribution is constantly being relaxed by quasi-linear relaxation and re-created by collisions; in this way a steady nonthermal level of Langmuir plasma waves is created, and these waves in turn produce microwave plasma radiation with a typical flux of 3 x 10 to the -16th erg/sq cm-sec. This flux can be enhanced by a factor of up to 100 by a high level of low-frequency (such as ion-acoustic) turbulence, which prevents quasi-linear relaxation for a sufficient fraction of the path length.

Emslie, A. G.↗