Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Requirements Development Issues for Advanced Life Support Systems: Solid Waste Management

Long duration missions pose substantial new challenges for solid waste management in Advanced Life Support (ALS) systems. These possibly include storing large volumes of waste material in a safe manner, rendering wastes stable or sterilized for extended periods of time, and/or processing wastes for recovery of vital resources. This is further complicated because future missions remain ill-defined with respect to waste stream quantity, composition and generation schedule. Without definitive knowledge of this information, development of requirements is hampered. Additionally, even if waste streams were well characterized, other operational and processing needs require clarification (e.g. resource recovery requirements, planetary protection constraints). Therefore, the development of solid waste management (SWM) subsystem requirements for long duration space missions is an inherently uncertain, complex and iterative process. The intent of this paper is to address some of the difficulties in writing requirements for missions that are not completely defined. This paper discusses an approach and motivation for ALS SWM requirements development, the characteristics of effective requirements, and the presence of those characteristics in requirements that are developed for uncertain missions. Associated drivers for life support system technological capability are also presented. A general means of requirements forecasting is discussed, including successive modification of requirements and the need to consider requirements integration among subsystems.

Levri, Julie A.↗

The Algorithm Theoretical Basis Document for the Derivation of Range and Range Distributions from Laser Pulse Waveform Analysis for Surface Elevations, Roughness, Slope, and Vegetation Heights

The primary purpose of the GLAS instrument is to detect ice elevation changes over time which are used to derive changes in ice volume. Other objectives include measuring sea ice freeboard, ocean and land surface elevation, surface roughness, and canopy heights over land. This Algorithm Theoretical Basis Document (ATBD) describes the theory and implementation behind the algorithms used to produce the level 1B products for waveform parameters and global elevation and the level 2 products that are specific to ice sheet, sea ice, land, and ocean elevations respectively. These output products, are defined in detail along with the associated quality, and the constraints, and assumptions used to derive them.

Brenner, Anita C.↗

V/STOL tilt rotor study. Volume 5: A mathematical model for real time flight simulation of the Bell model 301 tilt rotor research aircraft

A mathematical model for real-time flight simulation of a tilt rotor research aircraft was developed. The mathematical model was used to support the aircraft design, pilot training, and proof-of-concept aspects of the development program. The structure of the mathematical model is indicated by a block diagram. The mathematical model differs from that for a conventional fixed wing aircraft principally in the added requirement to represent the dynamics and aerodynamics of the rotors, the interaction of the rotor wake with the airframe, and the rotor control and drive systems. The constraints imposed on the mathematical model are defined.

P B Harendra↗

Dosimetric comparison of photon and proton treatment techniques for chondrosarcoma of thoracic spine

Chondrosarcomas are relatively radiotherapy resistant, and also delivering high radiation doses is not feasible owing to anatomic constraints. In this study, the feasibility of helical tomotherapy for treatment of chondrosarcoma of thoracic spine is explored and compared with other available photon and proton radiotherapy techniques in the clinical setting. A patient was treated for high-grade chondrosarcoma of the thoracic spine using tomotherapy. Retrospectively, the tomotherapy plan was compared with intensity-modulated radiation therapy, dynamic arc photon therapy, and proton therapy. Two primary comparisons were made: (1) comparison of normal tissue sparing with comparable target volume coverage (plan-1), and (2) comparison of target volume coverage with a constrained maximum dose to the cord center (plan-2). With constrained target volume coverage, proton plans were found to yield lower mean doses for all organs at risk (spinal cord, esophagus, heart, and both lungs). Tomotherapy planning resulted in the lowest mean dose to all organs at risk amongst photon-based methods. For cord dose constrained plans, the static-field intensity-modulated radiation therapy and dynamic arc plans resulted target underdosing in 20% and 12% of planning target volume2 volumes, respectively, whereas both proton and tomotherapy plans provided clinically acceptable target volume coverage with no portion of planning target volume2 receiving less than 90% of the prescribed dose. Tomotherapy plans are comparable to proton plans and produce superior results compared with other photon modalities. This feasibility study suggests that tomotherapy is an attractive alternative to proton radiotherapy for delivering high doses to lesions in the thoracic spine.

61 RADIATION PROTECTION AND DOSIMETRY↗

Microsimulation of Energy and Flow Effects from Optimal Automated Driving in Mixed Traffic

In this paper we study the energy and traffic impact of a proposed Anticipative Cruise Controller in a PTV VISSIM microsimulation environment. We dissect our controller into two parts: 1. the unconnected mode, active when following a human-driven vehicle, and 2. the connected mode, active when following another automated vehicle equipped with connectivity. Probabilistic constraints balance safety considerations with inter-vehicle compactness, and vehicle constraints for acceleration capabilities are expressed through the use of powertrain maps. Emergent highway traffic scenarios are then modeled using time headway distributions from empirical traffic data. To study the impact of automation over a range of demands of free-flow to stop-and-go, we vary vehicle flux from low to high and vary automated vehicle penetration from low to high. When examining all-human driving scenarios, network capacity failed to meet demand in high-volume scenarios, such as rush-hour traffic. We further find that with connected automated vehicles introduced, network capacity was improved to support the high-volume scenarios. Finally, we examine energy efficiencies of the fleet for conventional, electric, and hybrid vehicles. We find that automated vehicles perform at a 10%-20% higher energy efficiency over human drivers when considering conventional powertrains, and find that automated vehicles perform at a 3%-9% higher energy efficiency over human drivers when considering electric and hybrid powertrains. Due to secondary effects of smoothing traffic flow and reducing unnecessary braking, energy benefits also apply to human-driven vehicles that interact with automated ones. Such simulated humans were found to drive up to 10% more energy-efficiently than they did in the baseline all-human scenario.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ACCOUNTING FOR COSMIC VARIANCE IN STUDIES OF GRAVITATIONALLY LENSED HIGH-REDSHIFT GALAXIES IN THE HUBBLE FRONTIER FIELD CLUSTERS

Strong gravitational lensing provides a powerful means for studying faint galaxies in the distant universe. By magnifying the apparent brightness of background sources, massive clusters enable the detection of galaxies fainter than the usual sensitivity limit for blank fields. However, this gain in effective sensitivity comes at the cost of a reduced survey volume and, in this Letter, we demonstrate that there is an associated increase in the cosmic variance uncertainty. As an example, we show that the cosmic variance uncertainty of the high-redshift population viewed through the Hubble Space Telescope Frontier Field cluster Abell 2744 increases from ∼35% at redshift z ∼ 7 to ≳ 65% at z ∼ 10. Previous studies of high-redshift galaxies identified in the Frontier Fields have underestimated the cosmic variance uncertainty that will affect the ultimate constraints on both the faint-end slope of the high-redshift luminosity function and the cosmic star formation rate density, key goals of the Frontier Field program.

79 ASTRONOMY AND ASTROPHYSICS↗

Annual report for DOE VTO

Carbon fiber (CF)/polymer composites are a transformative class of high-performance, lightweight material, where high aspect-ratio CFs reinforce a polymer matrix and exceed the strength of steel alloys at a fraction of the density. Despite the advantages of such a class of material, the broader implementation of CF composites in a range of automotive, aerospace, and energy applications is hindered by limitations of current manufacturing methods. These current techniques (e.g., hand lay-up, wet filament winding) are costly and impose severe limitations on fiber placement, orientation, and angle, and thus a composite’s ultimate properties. Today’s CF composites are expensive to manufacture, limited in form factor, and utilize costly and sub-optimal continuous filament CF. Advanced additive manufacturing (AM) processes, combined with computational design optimization and new approaches to resin development, offer alternative design and manufacturing paradigms that have the realistic potential to lift these constraints. Such integrated AM approaches could thus help to realize the full potential of CF composite materials. One relevant application of CF composite materials where manufacturing constraints limit the cost-benefit ratio is in the manufacture of high-performance composite pressure vessels for onboard compressed natural gas (CNG) storage. Current CNG storage vessels (Types 3–5) are made from load-bearing filament-wound carbon-fiber composite and are ~3.5 times as expensive as an all-metallic Type-1 vessel. This cost is invariably tied to the complex and labor-intensive nature of conventional filament winding processes and the large volumes of expensive high tensile-strength CF tow feedstock required in manufacture. Our proposed approach to CNG storage vessel manufacture is based on a combination of AM technologies for CF composite printing and design optimization tools that were pioneered at Lawrence Livermore National Laboratory (LLNL), with advances in resin/composite formulation enabled by chemical and nano-material modification. Through the successful development of this technology, LLNL seeks to demonstrate the capability for advanced CNG storage vessel manufacture at reduced cost with no reduction in performance versus the most advanced, extant Type-5 designs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Standardized development of computer software. Part 1: Methods

This work is a two-volume set on standards for modern software engineering methodology. This volume presents a tutorial and practical guide to the efficient development of reliable computer software, a unified and coordinated discipline for design, coding, testing, documentation, and project organization and management. The aim of the monograph is to provide formal disciplines for increasing the probability of securing software that is characterized by high degrees of initial correctness, readability, and maintainability, and to promote practices which aid in the consistent and orderly development of a total software system within schedule and budgetary constraints. These disciplines are set forth as a set of rules to be applied during software development to drastically reduce the time traditionally spent in debugging, to increase documentation quality, to foster understandability among those who must come in contact with it, and to facilitate operations and alterations of the program as requirements on the program environment change.

Tausworthe, R. C.↗

Interplanetary program to optimize simulated trajectories (IPOST). Volume 4: Sample cases

The Interplanetary Program to Optimize Simulated Trajectories (IPOST) is intended to support many analysis phases, from early interplanetary feasibility studies through spacecraft development and operations. The IPOST output provides information for sizing and understanding mission impacts related to propulsion, guidance, communications, sensor/actuators, payload, and other dynamic and geometric environments. IPOST models three degree of freedom trajectory events, such as launch/ascent, orbital coast, propulsive maneuvering (impulsive and finite burn), gravity assist, and atmospheric entry. Trajectory propagation is performed using a choice of Cowell, Encke, Multiconic, Onestep, or Conic methods. The user identifies a desired sequence of trajectory events, and selects which parameters are independent (controls) and dependent (targets), as well as other constraints and the cost function. Targeting and optimization are performed using the Standard NPSOL algorithm. The IPOST structure allows sub-problems within a master optimization problem to aid in the general constrained parameter optimization solution. An alternate optimization method uses implicit simulation and collocation techniques.

Hong, P. E.↗

Interplanetary Program to Optimize Simulated Trajectories (IPOST). Volume 2: Analytic manual

The Interplanetary Program to Optimize Space Trajectories (IPOST) is intended to support many analysis phases, from early interplanetary feasibility studies through spacecraft development and operations. The IPOST output provides information for sizing and understanding mission impacts related to propulsion, guidance, communications, sensor/actuators, payload, and other dynamic and geometric environments. IPOST models three degree of freedom trajectory events, such as launch/ascent, orbital coast, propulsive maneuvering (impulsive and finite burn), gravity assist, and atmospheric entry. Trajectory propagation is performed using a choice of Cowell, Encke, Multiconic, Onestep, or Conic methods. The user identifies a desired sequence of trajectory events, and selects which parameters are independent (controls) and dependent (targets), as well as other constraints and the cost function. Targeting and optimization is performed using the Stanford NPSOL algorithm. IPOST structure allows subproblems within a master optimization problem to aid in the general constrained parameter optimization solution. An alternate optimization method uses implicit simulation and collocation techniques.

Hong, P. E.↗

Toxicity After Central versus Peripheral Lung Stereotactic Body Radiation Therapy: A Propensity Score Matched-Pair Analysis

Purpose: To compare toxicity after stereotactic body radiation therapy (SBRT) for “central” tumors—within 2 cm of the proximal bronchial tree or with planning tumor volume (PTV) touching mediastinum—versus noncentral (“peripheral”) lung tumors. Methods and Materials: From November 2005 to January 2011, 229 tumors (110 central, 119 peripheral; T1-3N0M0 non–small-cell lung cancer and limited lung metastases) in 196 consecutive patients followed prospectively at a single institution received moderate-dose SBRT (48-60 Gy in 4-5 fractions [biologic effective dose=100-132 Gy, α/β=10]) using 4-dimensional planning, online image-guided radiation therapy, and institutional dose constraints. Clinical adverse events (AEs) were graded prospectively at clinical and radiographic follow-up using Common Terminology Criteria for Adverse Events version 3.0. Pulmonary function test (PFT) decline was graded as 2 (25%-49.9% decline), 3 (50.0%-74.9% decline), or 4 (≥75.0% decline). Central/peripheral location was assessed retrospectively on planning CT scans. Groups were compared after propensity score matching. Characteristics were compared with χ{sup 2} and 2-tailed t tests, adverse events with χ{sup 2} test-for-trend, and cumulative incidence using competing risks analysis (Gray's test). Results: With 79 central and 79 peripheral tumors matched, no differences in AEs were observed after 17 months median follow-up. Two-year cumulative incidences of grade ≥2 pain, musculoskeletal, pulmonary, and skin AEs were 14%, 5%, 6%, and 10% (central) versus 19%, 10%, 10%, and 3% (peripheral), respectively (P=.31, .38, .70, and .09). Grade ≥2 cardiovascular, gastrointestinal, and central nervous system AEs were rare (<1%). Two-year incidences of grade ≥2 clinical AEs (28% vs 25%, P=.79), grade ≥2 PFT decline (36% vs 34%, P=.94), grade ≥3 clinical AEs (3% vs 7%, P=.48), and grade ≥3 PFT decline (0 vs 10%, P=.11) were similar for central versus peripheral tumors, respectively. Pooled 2-year incidences of grades 4 and 5 AEs were <1% and 0%, respectively, in both the prematched and matched groups. Conclusion: Moderate-dose SBRT with these techniques yields a similarly safe toxicity profile for both central and peripheral lung tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-540: Volumetric Modulated Total Body Irradiation Using a Rotational Lazy Susan-Like Immobilization System

Purpose: Traditional extended SSD total body irradiation (TBI) techniques can be problematic in terms of patient comfort and/or dose uniformity. This work aims to develop a comfortable TBI technique that achieves a uniform dose distribution to the total body while reducing the dose to organs at risk for complications. Methods: To maximize patient comfort, a lazy Susan-like couch top immobilization system which rotates about a pivot point was developed. During CT simulation, a patient is immobilized by a Vac-Lok bag within the body frame. The patient is scanned head-first and then feet-first following 180° rotation of the frame. The two scans are imported into the Pinnacle treatment planning system and concatenated to give a full-body CT dataset. Treatment planning matches multiple isocenter volumetric modulated arc (VMAT) fields of the upper body and multiple isocenter parallel-opposed fields of the lower body. VMAT fields of the torso are optimized to satisfy lung dose constraints while achieving a therapeutic dose to the torso. The multiple isocenter VMAT fields are delivered with an indexed couch, followed by body frame rotation about the pivot point to treat the lower body isocenters. The treatment workflow was simulated with a Rando phantom, and the plan was mapped to a solid water slab phantom for point- and film-dose measurements at multiple locations. Results: The treatment plan of 12Gy over 8 fractions achieved 80.2% coverage of the total body volume within ±10% of the prescription dose. The mean lung dose was 8.1 Gy. All ion chamber measurements were within ±1.7% compared to the calculated point doses. All relative film dosimetry showed at least a 98.0% gamma passing rate using a 3mm/3% passing criteria. Conclusion: The proposed patient comfort-oriented TBI technique provides for a uniform dose distribution within the total body while reducing the dose to the lungs.

60 APPLIED LIFE SCIENCES↗

SU-E-T-566: Comparison of VMAT and IMRT for Whole Abdomen Radiation Therapy (WART)

Purpose: Whole Abdomen Radiation Therapy (WART) is used in the treatment of desmoplastic small round cell tumors as well as other tumors with peritoneal dissemination. Intensity modulated radiation therapy (IMRT) is conventionally used to cover the multiple planning target volumes (PTVs) while sparing nearby critical structures, but this approach often requires two isocenters and ≥20 individual treatment fields. Four-field volumetric arc therapy (VMAT) can produce clinically similar treatment plans with the potential to reduce treatment time substantially. Here we examine treatment times and plan robustness for patients undergoing WART. Methods: Twenty patients undergoing WART at our institution were included in this study. Twelve IMRT and 8 VMAT plans utilized upper and lower abdominal isocenters and met similar dose constraints. Treatment times were tabulated from start of daily kV imaging to beam delivery end. Daily treatment couch coordinates were also recorded. From these couch coordinates, difference between actual and planned separation between isocenters was computed. Plan robustness with regard to PTV coverage within the region of field overlap was analyzed for 3 VMAT and 3 IMRT plans assuming a 2σ deviation in isocenter location. Results: The average treatment time for VMAT was 15 minutes shorter than for IMRT (27 minutes vs. 42 minutes). The average deviation in isocenter separation was 0.0 – 0.1 cm in each direction, with a standard deviation of 0.2 – 0.3 cm. Compared with IMRT plans, VMAT plans showed similar loss in PTV coverage for increasing isocenter displacement and similar dose inhomogeneity with decreasing isocenter displacement. Conclusion: Use of VMAT results in substantial time-savings for 2-isocenter whole abdomen radiotherapy plans. VMAT plans show robustness similar to IMRT with respect to isocenter displacement. VMAT should be considered for these very complicated treatments to minimize risk of patient movement during therapy and maximize treatment delivery efficiency.

60 APPLIED LIFE SCIENCES↗

The evolution of CO2 on Mars

At the surface, the atmosphere of Mars contains approximately 95.3 percent CO2 by volume. At the Viking Lander 1 (VL1) site, the total surface pressure varied with the season between about 6.89 and 8.94 mbar. Questions related to the observed CO2 pressure on Mars are explored. Several published estimates of the total amount of CO2 outgassed over the history of Mars, varying between 140 and 3000 mbar, are shown in a table. It is pointed out that the study of likely reservoirs for outgassed CO2 has focused mainly on the polar caps and regolith. Constraints on the formation of transitory pockets of moist soil are discussed, taking into account heat requirements, supply of water, and constraints related to pressure. Attention is also given to chemical considerations, implications for the current status of CO2 reservoirs, and scenarios for the evolution of CO2 pressure.

Kahn, R.↗

I 2 S-LWR microchannel heat exchanger design and experimental validation

The Integral Inherently Safe Light Water Reactor (I 2 S-LWR) includes primary-to-secondary coolant heat exchangers located in the downcomer of the reactor pressure vessel. A microchannel heat exchanger (MCHX) configuration is selected to meet the limited available volume and high heat duty requirements. The design, modeling, and optimization of the liquid-liquid MCHX is outlined. In addition, the performance of a MCHX test section representative of the I 2 S-LWR MCHX design is validated experimentally. Experimental results show that heat transfer and pressure drop correlations developed for larger, macroscale channels lead to accurate predictions of performance. Additionally, this study shows that an MCHX can deliver the required heat duties within the available space and pressure drop constraints of the overall I2 S-LWR design.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Contralateral Esophagus-Sparing Technique to Limit Severe Esophagitis Associated With Concurrent High-Dose Radiation and Chemotherapy in Patients With Thoracic Malignancies

Purpose: Severe (Radiation Therapy Oncology Group [RTOG] grade 3 or greater) esophagitis generally occurs in 15% to 25% of non–small cell lung cancer (NSCLC) patients undergoing concurrent chemotherapy and radiation therapy (CCRT), which may result in treatment breaks that compromise local tumor control and pose a barrier to dose escalation. Here, we report a novel contralateral esophagus-sparing technique (CEST) that uses intensity modulated radiation therapy (IMRT) to reduce the incidence of severe esophagitis. Methods and Materials: We reviewed consecutive patients with thoracic malignancies undergoing curative CCRT in whom CEST was used. The esophageal wall contralateral (CE) to the tumor was contoured as an avoidance structure, and IMRT was used to guide a rapid dose falloff gradient beyond the target volume in close proximity to the esophagus. Esophagitis was recorded based on the RTOG acute toxicity grading system. Results: We identified 20 consecutive patients treated with CCRT of at least 63 Gy in whom there was gross tumor within 1 cm of the esophagus. The median radiation dose was 70.2 Gy (range, 63-72.15 Gy). In all patients, ≥99% of the planning and internal target volumes was covered by ≥90% and 100% of prescription dose, respectively. Strikingly, no patient experienced grade ≥3 esophagitis (95% confidence limits, 0%-16%) despite the high total doses delivered. The median maximum dose, V45, and V55 of the CE were 60.7 Gy, 2.1 cc, and 0.4 cc, respectively, indicating effective esophagus cross-section sparing by CEST. Conclusion: We report a simple yet effective method to avoid exposing the entire esophagus cross-section to high doses. By using proposed CE dose constraints of V45 <2.5 cc and V55 <0.5 cc, CEST may improve the esophagus toxicity profile in thoracic cancer patients receiving CCRT even at doses above the standard 60- to 63-Gy levels. Prospective testing of CEST is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Constraints on brane inflation and cosmic strings

By considering simple, but representative, models of brane inflation from a single brane-antibrane pair in the slow roll regime, we provide constraints on the parameters of the theory imposed by measurements of the cosmic microwave background (CMB) anisotropies by WMAP (Wilkinson Microwave Anisotropy Probe) including a cosmic string component. We find that inclusion of the string component is critical in constraining parameters. In the most general model studied, which includes an inflaton mass term, as well as the brane-antibrane attraction, values n{sub s}<1.02 are compatible with the data at 95% confidence level. We are also able to constrain the volume of the warped throat region (modulo factors dependent on the warp factor) and the value of the inflaton field to be <0.66M{sub P} at horizon exit. We also investigate models with a mass term. These observational considerations suggest that such models have r<2 Multiplication-Sign 10{sup -5}, which can only be circumvented in the fast roll regime, or by increasing the number of antibranes. Such a value of r would not be detectable in any CMB polarization experiment likely in the near future, but the B-mode signal from the cosmic strings could be detectable. We present forecasts of what a similar analysis using PLANCK data would yield and find that it should be possible to rule out G{mu}>6.5 Multiplication-Sign 10{sup -8} using just the TT, TE and EE power spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-BRB-14: Dosimetric Effects at Air- Tissue Boundary Due to Magnetic Field in MR-Guided IMRT/VMAT Delivery for Head and Neck Cancer

Purpose: The advent of the MR-Linac enables real-time and high soft tissue contrast image guidance in radiation therapy (RT) delivery. Potential hot-spots at air-tissue interfaces, such as the sphenoid sinus, in RT for head and neck cancer (HNC), could potentially occur due to the electron return effect (ERE). In this study, we investigate the dosimetric effects of ERE on the dose distribution at air-tissues interfaces in HNC IMRT treatment planning. Methods: IMRT plans were generated based on planning CT’s acquired for HNC cases (nasopharynx, base of skull and paranasal sinus) using a research planning system (Monaco, v5.09.06, Elekta) employing Monte Carlo dose calculations with or without the presence of a transverse magnetic field (TMF). The dose in the air cavity was calculated in a 1 & 2 mm thick tissue layer, while the dose to the skin was calculated in a 1, 3 and 5 mm thick tissue layer. The maximum dose received in 1 cc volume, D1cc, were collected at different TMF strengths. Plan qualities generated with or without TMF or with increasing TMF were compared in terms of commonly-used dose-volume parameters (DVPs). Results: Variations in DVPs between plans with and without a TMF present were found to be within 5% of the planning CT. The presence of a TMF results in <5% changes in sinus air tissue interface. The largest skin dose differences with and without TMF were found within 1 mm of the skin surface Conclusion: The presence of a TMF results in practically insignificant changes in HNC IMRT plan quality, except for skin dose. Planning optimization with skin DV constraints could reduce the skin doses. This research was partially supported by Elekta Inc. (Crowley, U.K.)

60 APPLIED LIFE SCIENCES↗