Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

ZPPR Test Bed (ZTB) Pre-Conceptual Design Report

Authorized by the Nuclear Energy Innovation Capabilities Act (NEICA), the National Reactor Innovation Center (NRIC) provides private sector technology developers access to strategic infrastructures and assets for commercial nuclear energy research, development, demonstration, and deployment activities. The mission is to support a timely and cost-effective path to the licensing and commercialization of new nuclear energy systems. To meet these needs, NRIC is developing two reactor demonstration test beds at Idaho National Laboratory (INL), the ZPPR Test bed (ZTB) and the EBR-II Test bed (ETB). ZTB will support the demonstration of systems that operate at less than 500 kWt. The baseline objective is for the ZPPR Cell to act as a confinement structure capable of siting reactors that utilize Safeguards Category 1 material for operations. The major areas addressed in the pre-conceptual design include: • Installation of an access door • Electrical Power • Heat Removal • Ventilation in the Cell • Reactor Installation Along with the design for ZTB, a concept of operations (COP) has also been developed. The COP is intended to facilitate a common understanding of ideas, challenges, and issues. As systems continue to evolve in complexity System Engineers and Project Directors will utilize and update the COP to develop and sustain a common vision of the system for stakeholders.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Specification 01000S, Building XXX Institutional General Plant Project

Design and construct a high-bay facility with penthouse mechanical area that meets the physical and functional requirements as described in this document. Using the Modular High Bay Programming Plan, contractor shall validate programming requirements including equipment to be installed; room sizes and quantities; heating, ventilation, and air- conditioning (HVAC) and electrical requirements, including sizing of equipment based on heat load; and other specific needs. Contractor shall provide the design development, engineering, construction drawings, construction and construction administration services required to completely define, document, and construct the facility to the requirements described in the Building XXX Programming Plan and those referenced herein.

42 ENGINEERING↗

Hotel Room Computational Fluid Dynamics to Investigate Airborne Pathogen Dispersal Patterns

A hotel room unit consisting of a bedroom and bathroom was modelled using computational fluid dynamics (CFD) to investigate airborne pathogen dispersal patterns. The full-scale model includes a ‘typical’ hotel room configuration, furniture, and vents. The air sources and sinks include a bathroom vent, a heating, ventilation, and cooling (HVAC) unit located in the bedroom, and a ½” gap at the bottom of the entry door. In addition, the entry door and window can be opened or closed, as desired. Three key configuration simulations were conducted: 1) both the bathroom vent and HVAC were on, 2) only the HVAC was on, and 3) only the bathroom vent was on. If the HVAC air is from a fresh, clean source, or passes through a high-efficiency filter/UV device, then the first configuration is the safest, as contaminated air is highly reduced. The second configuration is also safe, but does not benefit from the outsourcing of potentially-infected air, such as contaminated air flowing through an ineffective filter. The third configuration should be avoided, as the bathroom vent causes air to flow from the hallway, which can be of dubious origin. The CFD simulations also showed that recirculation and swirling regions tend to accumulate the largest concentrations of heavier airborne particles, pathogens, dust, etc. These regions are associated with the largest turbulence kinetic energy (TKE) , and tend to occur in areas with flow recirculation and corners. Therefore, TKE presents a reasonable metric to guide the strategic location of pathogen mitigation devices. The simulations show complex flow patterns with distinct upper and lower flow regions, swirling flow, and significant levels of turbulent mixing. These simulations provide intriguing insights that can be applied to help mitigate pathogen aerosol dispersal, generate building design guidelines, as well as provide insights for the strategic placement of mitigation devices, such as ultraviolet (UV) light, supplemental fans, and filters.

54 ENVIRONMENTAL SCIENCES↗

National Park Service Bus Electrification Study: 2020 Report

This report summarizes important considerations for implementing BEBs in the three national park fleets, detailing information about current buses at each fleet, electric bus demonstration vehicles, as well as performance evaluations of BEBs in Zion, Bryce, and Yosemite. Results include in-use data collection results reporting metrics such as average bus speed, energy usage per trip, and daily distance traveled, as well as effects of high heating, ventilation, and air conditioning (HVAC) system use to both heat and cool the buses, emissions estimations before and after use of electric buses, operating costs, electric vehicle infrastructure, maintenance, and bus driver user experience survey information. Analysis results from this project will help the NPS understand how BEBs and future expansion of BEBs could assist in meeting their bottom line and operational goals and assist NPS in choosing appropriate locations for future BEB deployments.

33 ADVANCED PROPULSION SYSTEMS↗

Hamilton: Flexible, Open Source $10 Wireless Sensor System for Energy Efficient Building Operation

Sensors for improving building performance are rapidly populating the market, driven in part by the drive to reduce greenhouse gas emissions resulting from energy production as well as improve the interior environment for healthy and more productive spaces. UC Berkeley has led wireless sensor development over the past 25 years (e.g., Telos mote), with the Hamilton (named after Alexander Hamilton on the US $10 bill) as the most recent. The Hamilton sensor was designed as a low-cost high-performance sensor that is modular and interoperable. The objective of the Hamilton project was to create, evaluate and establish the technological foundations for secure and easy to deploy building energy efficiency applications utilizing pervasive, low-cost wireless sensors integrated with traditional Building Management Systems (BMS), consumer-sector building components, and powerful data analytics. The project included iterative hardware design, incorporating a high-performance database (BTrDb, http://btrdb.io/), creating and iterating the development of secure data middleware (BOSSwave, WAVE/WAVEMQ), working with and pushing the development of an open-source tiny operating system RiotOS, and implementing and improving protocols such as Thread/OpenThread and TCP/IP. The hardware benefited from careful design to drive down the cost; the design included a System-on-a-Chip (SoC), chip antenna, single crystal and five passive components. Careful design of the operating system created a low-power design to enable a long life with small batteries. The hardware included several sensors: temperature, radiant temperature, relative humidity, magnetometer, accelerometer, and light, with an optional occupancy (Passive InfraRed) sensor. The project was the basis of several applications, both internal to the research team and other researchers and professionals at other institutions. Several applications used the sensor hardware as the basis for other complex devices. Other applications used the sensors to improve building performance through interoperating with the building Heating Ventilation and Air-Conditioning (HVAC) system, such as using occupancy and/or distributed temperature sensing to reduce HVAC zone energy while still providing thermal comfort and to reduce peak loads in small commercial buildings. We demonstrated cloud-based energy analytics, implemented a schedule and a Model Predictive Controller in a small commercial building to optimize HVAC energy, occupancy and electricity price. Initial integration of these technological innovations was performed through the creation of execution containers containing the WAVE agent and various driver, proxy, or building system function logic. The research added to the understanding of efficient sensor hardware, secure middleware, time-series data management (high performance database), efficient communication protocols, and interoperating with applications and building systems. The project showed the technical effectiveness and economic feasibility of creating a low-cost, modular, and easy-to-deploy sensor. Through conversations with multiple end users, the research team discovered that many customers wanted data management and services in addition to the sensors. HamiltonIOT developed packages of sensors, border router, and data services to provide a seamless “plug-and-play” sensor deployment. Some customers were willing to pay for higher quality sensors (such as light); some customers wanted a robust enclosure (waterproof).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tritiated Sulfur Hexafluoride Disposition Strategies

Tritium (T 2 ) is a radioactive isotope of hydrogen that is produced in nuclear fission reactions and is often used in nuclear fusion reactions and accelerator-based applications for medical isotope production. As a hydrogen isotope, tritium can readily bind to hydroxyl radicals (OH), forming tritiated water (HTO or T 2 0), and to carbon atoms. Tritium decays to helium-3 ( 3 He) via beta-decay with max decay energy of 18.6 keV. While it is not an external radiation hazard, it can be an internal radiation hazard if tritium is inhaled, ingested, or absorbed through the skin. In applications where tritium is handled, tritium confinement is performed using different barriers to minimize releases to the environment. For gaseous (elemental), liquid (oxide), and metal (hydride) tritium, process piping and components provide the primary confinement function. Secondary tritium confinement is typically provided by inert (i.e. non-flammable gases such as nitrogen, argon, or helium) gloveboxes which are connected to a tritium stripper system. Primary tritium confinement barriers typically produce low volumes of high tritium concentrations of tritiated methane from carbon in steels or organic materials along with tritiated water/tritium oxide (e.g. HTO) and tritiated ammonia from reactions with oxygen and nitrogen. Tritium escaping primary confinement into secondary confinement atmospheres (e.g. gloveboxes) produce higher volumes of lower activity contamination than found in process piping. Tritium contamination also occurs by leaks or tritium permeation/diffusion through confinement materials. Tritium from inside primary confinement barriers will diffuse or leak out of the primary confinement barrier and usually into the air, if the system is inside an air hood or ventilated hot cell, or into the secondary confinement (e.g. glovebox) atmosphere which is either exhausted or stripped based on the function of the secondary confinement (glovebox) system. Accelerator based processes for medical isotope production represent an atypical tritium contamination challenge. In medical isotope production, deuterium supply gas is ionized and accelerated to a tritium gas target to produce neutrons that are then used to produce the medical isotopes through additional nuclear fission reactions. To create large voltage differentials for accelerator operations, an electrical insulation medium is needed to prevent or rapidly quench electric discharges. A common electrical insulation medium utilized in accelerator applications is sulfur hexafluoride (SF 6 ) gas. SF 6 has a high dielectric strength and allows for the construction of smaller accelerator systems compared to other electrical insulation mediums such as air or dry nitrogen. Due to tritium permeation/diffusion through accelerator process and confinement materials, there is the possibility that tritium can contaminate the electrical insulation medium of the accelerator. Tritium contaminated SF 6 creates a material without any obvious processes for managing the contamination, reuse, or disposal of the used SF 6 . This document will discuss possible management strategies for tritium contaminated SF 6 for accelerator-based processes for Molybdenum-99 (Mo-99) production.

07 ISOTOPE AND RADIATION SOURCES↗

Smart Labs Final Report Summer 2021

The Smart Labs Project at Los Alamos National Laboratory (LANL) is an initiative derived from The University of California, Irvine and is part of the Department of Energy’s (DOE) Better Buildings Challenge. These carbon abatement strategies aim to reduce energy consumption of laboratories while also maintaining health and safety requirements. Smart Labs designs incorporate seven key principles which are: digital control systems, demand-based ventilation, low power-density demand-based lighting, exhaust fan discharge velocity optimization, pressure drop optimization, fume hood flow optimization, and commissioning with automated cross-platform fault detection. As the ALDCP Smart Labs team for the summer of 2021, the scope of the project is to determine the energy savings within building 03-1698 (Material Science Laboratory - MSL). Over the past couple of years, the Sustainability Group has been adding Smart Labs upgrades into the MSL building and the summer team would like to understand the impact made for the overall energy consumption/demand and safety for the building, determine the overall return on investment (ROI), and recommend more Smart Labs upgrades that can be added to the MSL building. The goal is to enable the UI FOD (Utilities and Infrastructure Facility Operation Division) to promote more Smart Labs projects in the future and further the reputation LANL and DOE facilities have of being leading examples of developers of high performing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Science and Technology Review June 2021

When the COVID-19 pandemic hit, Lawrence Livermore National Laboratory scientists came together, leveraging many different disciplines and technologies to address this global challenge. Livermore focused on three areas of research: creating alternatives for medical equipment in short supply, such as ventilators and nasal swabs; developing methods to help detect the SARS-CoV-2 virus responsible for COVID-19; and designing medical countermeasures such as antibodies and antivirals to combat the disease.

36 MATERIALS SCIENCE↗

Supercritical CO2 sterilization of N95 Masks

A preliminary investigation of the use of supercritical carbon dioxide for treating of 3M 1860 N95 masks was undertaken to evaluate a potential route to low-cost, scalable, sterilization of personal protective equipment for multiple reuse in hospital settings. Upon entering the supercritical regime, the normally distinct liquid and gaseous phases of CO 2 merge into a single homogeneous phase that has density, short-range order, and solvation capacity of a liquid, but the volume-filling and permeation properties that of a gas. This enables supercritical CO2 to function as a vehicle for delivery of biocidal agents such peracetic acid into microporous structures. The potentially adverse effect of a liquid-to-gas phase transition on mask filter media is avoided by conducting cleaning operations above 31 C, the critical temperature for carbon dioxide. A sample of fifteen 3M 1860 N95 masks was subjected to ten consecutive cycles of supercritical CO 2 cleaning to determine its effect on mask performance. These 15 masks, along with 5 control samples then underwent a battery of standardized tests at the CDC NIOSH NPPTL research facility in Pittsburgh, PA. The data from these tests strongly suggest (but do not prove) that supercritical carbon dioxide do not damage 3M 1860 N95 masks. Additional tests conducted during this project confirmed the compatibility of supercritical CO 2 with ventilator tubing that, like N95 masks, has been in short supply during portions of the COVID-19 pandemic and cannot be sterilized by conventional means. Finally, a control experiment was also conducted to examine the effect of supercritical CO 2 on a BSL-2 surrogate virus, vesicular stomatitis virus (VSV), Indiana serotype strain. In the absence of biocidal additives, supercritical CO 2 exhibited no measurable lethality against VSV. This surrogate virus experiment suggests that a biocidal additive such as peracetic acid will be necessary to achieve required sterilization metrics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technical analysis of filter testing at the U.S. Department of Energy Filter Test Facility

The U.S. Department of Energy (DOE) technical standard DOE-STD-3020-2015 requires verification testing at the Filter Test Facility (FTF) of high-efficiency particulate air (HEPA) filters to be installed in nuclear facility (Hazard Category 1, 2, 3, and radiological facilities) confinement ventilation systems, or to be installed in habitability systems (e.g., filters for protection of workers required to act for the control and mitigation of emergency situations). Filters in these applications perform a safety function in accident situations, are designated as important to safety, or are necessary for habitability systems. Different FTFs have operated for decades, and results of tests are available to examine the need for and benefits of continued execution of 100 percent QA verification testing. The objective of this study and resulting report was to assess the need for 100 percent QA testing at the current FTF in Maryland, based on an examination of a database of test results from 2013 to August 2020. Filters that require independent testing per DOE-STD-3020-2015 to be installed in nuclear facilities are sent to the FTF before being shipped to the facilities. The FTF examines the documentation (e.g., certificates of compliance, results of particle penetration and airflow resistance testing by the manufacturers, labels affixed to filters and packages, and other requirements specified in purchase orders by the nuclear facility operators), implements visual inspections of the physical state of the filters, and checks the dimensions of frames. Filters that meet the documentation and visual inspection requirements are subjected to particle penetration and airflow resistance testing. In case of rejections, the filters are shipped back to the manufacturers, at the cost of the manufacturers, for replacement. Filters that pass all tests are shipped to the nuclear facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Similar Exposure Group [Stick Welding without LEV - Manganese - RiskLevel 4]

This memorandum is presented to summarize quantitative worker exposure data collected while performing shielded metal arc welding (“SMAW” or “stick”) without local exhaust ventilation (LEV) and to validate if the appropriate risk level has been assigned to this task using Bayesian Decision Analysis (BDA). The purpose of this exposure assessment is to determine if it can be stated with at least 75% certainty that the true exposure profile (i.e., 95 th percentile) of the SEG is at or below the risk level currently assigned to this SEG.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Distribution System Operator with Transactive (DSO+T) Study

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution System Operator with Transactive (DSO+T) Study: Volume 1 (Main Report)

The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. Using a highly interdisciplinary co-simulation and valuation framework, this assessment encompasses the entire electrical delivery system from bulk system generation and transmission, through the distribution system, to the modeling of individual customer buildings and flexible assets (including heating, ventilation, and air conditioning [HVAC] units, water heaters, batteries, and electric vehicles). The study exercises a transactive energy retail market coordination scheme designed to integrate with an existing day-ahead and real-time competitive wholesale electricity market. Software decision-making agents are designed for the retail market operator as well as various price-responsive flexible assets. The engineering and economic performance of the transactive energy scheme is studied for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DSO+T: Transactive Energy Coordination Framework (DSO+T Study: Volume 3)

This report describes a transactive energy coordination scheme designed to integrate into existing day-ahead and real-time wholesale energy markets. This scheme was evaluated in the Distribution System Operator with Transactive (DSO+T) study to assess the engineering and economic performance of the transactive energy coordination of a large-scale deployment of distributed energy resources (DER). Transactive agents were developed for a range of DERs (heating, ventilation, and air conditioning units, water heaters, batteries, and electric vehicles) that optimize flexibility over a 48-hour horizon and adjust their strategy in response to changes in real-time prices. A transactive energy coordination scheme, executed by a DSO retail market operator, aggregates these DER bids from participating customers and clears them against a DSO supply curve using a double auction market mechanism. The process of constructing the price-quantity DSO supply curve includes distribution-level transportation constraints (for example, substation congestion limits) and forecast locational marginal price of the DSO’s connected transmission node. The resulting day-ahead and real-time quantities are then bid into a competitive wholesale market operated by an independent system operator. This report also details additional capabilities for proper marketplace simulation such as wholesale price, weather, and load forecasting. The report concludes with a discussion of lessons learned and key design features required to ensure successful operation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Barriers to Broader Utilization of Fault Detection Technologies for Improving Residential HVAC Equipment Efficiency

Faults in residential heating, ventilating, and air conditioning (HVAC) equipment may occur due to poor installation practices or develop over time, and these faults can negatively impact system efficiency, thermal comfort, and equipment lifespan. Automated fault detection and diagnostic (AFDD) technologies identify energy wasting HVAC faults, such as low indoor airflow and improper refrigerant charge, and guide technicians in improving system efficiency. For residential HVAC, AFDD consists of a range of fault detecting and diagnostic capabilities, sensor configurations, and target applications. AFDD technology can either be permanently installed by the original equipment manufacturer (OEM) using embedded sensors or as an add-on product either during or after installation. Additionally, several advanced installation tools and refrigerant gauge sets include AFDD features for temporary use during equipment installation and tune-ups. Some technologies can detect a fault but have limited diagnostic capabilities. For example, a single-point measurement from the home's thermostat or energy monitor can provide certain fault detection capability by analyzing the equipment runtime or energy consumption. These technologies, though limited at determining the cause of a given fault, may have significant energy savings potential due to their low cost and prevalence in the residential HVAC market. Despite the potential benefits, fault detection technologies face many technical and market barriers preventing broad adoption. Beyond the cost barriers due to the added sensor requirements and technology development, fault detection technologies face many implementation and adoption barriers such as installer training, customer awareness, standardized communication protocols, and methods of test for evaluating accuracy. The purpose of this whitepaper is to characterize market and technical barriers impeding broader utilization of fault detection technology for residential HVAC energy efficiency applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pathway to Zero Energy Windows: Advancing Technologies and Market Adoption

As of 2021, buildings account for 39.1% of total U.S. primary energy use and 75% of total U.S. electricity use. Much of this energy is used to maintain a comfortable indoor environment. The building envelope consists of transparent and opaque elements that serve as a controllable barrier to help maintain the indoor environment regardless of external conditions. The envelope also allows the exchange of light and air, as well as other transfers with the external environment when it is beneficial for the building occupants. By leveraging desirable external environmental conditions (e.g., fresh air and natural light) and mitigating the influence of undesirable conditions (e.g., moisture, hot or cold temperatures, wind), the building envelope can reduce the need for space conditioning and electric light, and thus reduce energy use associated with lighting and heating, cooling, and ventilation equipment. In turn, high-performance building envelopes can reduce the substantial CO 2 emissions associated with energy use to satisfy heating, cooling, and lighting needs in buildings. The U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) Emerging Technologies program supports R&D for technologies, systems, and software tools that can contribute to reductions in building energy use. Emerging Technologies funding is distributed competitively through solicitations (e.g., Funding Opportunity Announcements and National Lab Calls, which in general are open to applications from industry, academia, national laboratories, and other entities) and other mechanisms. This document focuses on R&D for windows and window system technologies and will provide guidance for BTO's investments in developing the next generation of high-performance, affordable, cost competitive windows, as well as integrated daylighting and shading technologies in partnership with industry and researchers. This document also addresses areas where DOE invests in software and design tools that translate sophisticated and complex physics into easy-to-use energy performance and optimization methods used by industry and other stakeholders for implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Completion of initial reduced-order model for flammable refrigerant dispersal in residential spaces

Environmental regulations aimed at reducing global warming impacts of HVAC&R refrigerants have resulted in the phase-out of chlorofluorocarbons (CFCs) in 2010 and hydrochlorofluorocarbons (HCFCs) by 2030 in developed countries with additional restrictions on the use of hydrofluorocarbons (HFCs) set to take effect in 2036. Many of the remaining alternative refrigerants that have lower global warming potential (GWP) and that are suitable for use in HVAC&R systems (e.g., propane, difluoromethane) are flammable to some degree. Flammable refrigerants introduce new challenges and hazards to property and personal safety related to potential deflagration during system maintenance or due to leakage of the refrigerant accumulating in the conditioned space. Standards have been developed to set maximum charge limits for flammable refrigerants in HVAC&R systems; however, existing safety standards and codes still restrict their use. The bodies that maintain and update these codes need publicly available, science-based information to enable credible guidelines for setting safe charge limits for different flammable refrigerants in different HVAC&R applications. In 2016, the Alliance for Responsible Atmospheric Policy, the Air-Conditioning Heating and Refrigeration Institute (AHRI), ASHRAE, the U.S. Department of Energy (DOE), and the State of California began efforts to develop such information. As part of this effort, Oak Ridge National Laboratory (ORNL) began the current, ongoing project to examine imposed charge limits for flammable refrigerants and identify reasonable adjustments to these limits when found appropriate. Past tasks under this project have included development of experimentally vetted, computational fluid dynamics (CFD) simulation approaches to study the results of leakage of flammable refrigerants from various HVAC&R systems into different types of commercial and residential spaces. In this report, we discuss recent efforts to develop a predictive model of the flammable volume fraction and accumulated refrigerant mass in a single-room residential space resulting from the leak of a flammable refrigerant from a small room air conditioning (RAC) unit. The eventual goal is development of a model suitable for public release which could simulate a range of scenarios. In discussions with the AHRTI Flammable Refrigerant Subcommittee (FRS) at the beginning of this effort, a total of 9 input parameters were chosen for consideration including room area, room/door opening area, ventilation fan flow rate, unit/leak height, leak area, leak rate, total refrigerant charge, refrigerant molecular weight, and state of the unit fan.

42 ENGINEERING↗