Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Using”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

High resolution absorption spectroscopy of exploding wire plasmas using an x-pinch x-ray source and spherically bent crystal

We present here the use of absorption spectroscopy of the continuum radiation from x-pinch-produced point x-ray sources as a diagnostic to investigate the properties of aluminum plasmas created by pulsed power machines. This technique is being developed to determine the charge state, temperature, and density as a function of time and space under conditions that are inaccessible to x-ray emission spectroscopic diagnostics. The apparatus and its characterization are described, and the spectrometer dispersion, magnification, and resolution are calculated and compared with experimental results. Spectral resolution of about 5000 and spatial resolution of about 20 {mu}m are demonstrated. This spectral resolution is the highest available to date in an absorption experiment. The beneficial properties of the x-pinch x-ray source as the backlighter for this diagnostic are the small source size (<5 {mu}m), smooth continuum radiation, and short pulse duration (<0.1 ns). Results from a closely spaced (1 mm) exploding wire pair are shown and the general features are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct observation of fatigue in epitaxially grown Pb(Zr,Ti)O 3 thin films using second harmonic piezoresponse force microscopy

In this study, we present a direct observation of fatigue phenomena in epitaxially grown Pb(Zr 0.2 Ti 0.8 )O 3 (PZT)thin films using second harmonic piezoresponse force microscopy (SH-PFM). We observed strong correlation between the SH-PFM amplitude and phase signals with the remnant piezoresponse at different switching cycles. The SH-PFM results indicate that the average fraction of switchable domains decreases globally and the phase delays of polarization switching differ locally. In addition, we found that the fatigue developed uniformly over the whole area without developing region-by-region suppression of switchable polarization as in polycrystalline PZTthin films.

36 MATERIALS SCIENCE↗

Elemental and magnetic sensitive imaging using x-ray excited luminescence microscopy

We demonstrate the potential of x-ray excited luminescence microscopy for full-field elemental and magnetic sensitive imaging using a commercially available optical microscope, mounted on preexisting synchrotron radiation (SR) beamline end stations. The principal components of the instrument will be described. Bench top measurements indicate that a resolution of 1 {mu}m or better is possible; this value was degraded in practice due to vibrations and/or drift in the end station and associated manipulator. X-ray energy dependent measurements performed on model solar cell materials and lithographically patterned magnetic thin film structures reveal clear elemental and magnetic signatures. The merits of the apparatus will be discussed in terms of conventional SR imaging techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Communication: A vibrational study of propargyl cation using the vacuum ultraviolet laser velocity-map imaging photoelectron method

By employing the vacuum ultraviolet (VUV) laser velocity-map imaging photoelectron (VUV-VMI-PE) method, we have obtained a vibrationally resolved photoelectron spectrum of gaseous propargyl radical [C{sub 3}H{sub 3}(X{sup 2}B{sub 1})] in the energy range of 0-4600 cm{sup -1} above its ionization energy. The cold C{sub 3}H{sub 3} radicals were produced from a supersonically cooled radical beam source based on 193 nm ArF photodissociation of C{sub 3}H{sub 3}Cl. The VUV-VMI-PE spectrum of C{sub 3}H{sub 3} thus obtained reveals a Franck-Condon factor (FCF) pattern with a highly dominant origin band along with weak vibrational progressions associated with excitations of the C-C {nu}{sub 5}{sup +}(a{sub 1}) and C{identical_to}C {nu}{sub 3}{sup +}(a{sub 1}) symmetric stretching modes and the CCH {nu}{sub 7}{sup +}(b{sub 1}) out-of-plane bending mode of C{sub 3}H{sub 3}{sup +}(X{sup 1}A{sub 1}). The {nu}{sub 5}{sup +}(a{sub 1}) vibrational frequency of 1120 cm{sup -1} determined in the present study is lower than the value deduced from the recent Ar-tagged infrared photodissociation study by 102 cm{sup -1}, confirming the highly accurate vibrational frequency predictions obtained by the most recent state-of-the-art ab initio quantum calculations. The observation of the FCF disallowed {nu}{sub 7}{sup +}(b{sub 1}) mode is indicative of vibronic interactions. The discrepancy observed between the FCF pattern determined in the present study and that predicted by a recent high-level quantum theoretical investigation can be taken as evidence that the potential energy surfaces used in the latter theoretical study are in need of improvement in order to provide a reliable FCF prediction for the C{sub 3}H{sub 3}/C{sub 3}H{sub 3}{sup +} photoionization system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real time x-ray studies during nanostructure formation on silicon via low energy ion beam irradiation using ultrathin iron films

Real time grazing incidence small angle x-ray scattering and x-ray fluorescence (XRF) are used to elucidate nanodot formation on silicon surfaces during low energy ion beam irradiation of ultrathin iron-coated silicon substrates. Four surface modification stages were identified: (1) surface roughening due to film erosion, (2) surface smoothing and silicon-iron mixing, (3) structure formation, and (4) structure smoothing. The results conclude that 2.5 Multiplication-Sign 10{sup 15} iron atoms in a 50 nm depth triggers surface nanopatterning with a correlated nanodots distance of 25 nm. Moreover, there is a wide window in time where the surface can have correlated nanostructures even after the removal of all the iron atoms from the sample as confirmed by XRF and ex-situ x-ray photoelectron spectroscopy (XPS). In addition, in-situ XPS results indicated silicide formation, which plays a role in the structure formation mechanism.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Nanoparticle size and morphology control using ultrafast laser induced forward transfer of Ni thin films

We have developed a nanoparticle (NP) printing technique using Ni thin film lift-off from glass substrates after ultrafast irradiation in air. Unique interactions of ultrafast laser pulses with thin films allow for control over NP faceting and size distributions. Control is achieved by changing the laser fluence, film thickness, and film-substrate distance. We demonstrate 20 nm Ni film removal from substrates and rapid NP printing, with size distributions centered at a 6 nm diameter. When the Ni film thickness is lowered to 10 nm, NPs are printed with distributions peaked at a 2 nm diameter.

36 MATERIALS SCIENCE↗

Use of soft x-ray diagnostic on the COMPASS tokamak for investigations of sawteeth crash neighborhood and of plasma position using fast inversion methods

The soft x-ray diagnostic is suitable for monitoring plasma activity in the tokamak core, e.g., sawtooth instability. Moreover, spatially resolved measurements can provide information about plasma position and shape, which can supplement magnetic measurements. In this contribution, fast algorithms with the potential for a real-time use are tested on the data from the COMPASS tokamak. In addition, the soft x-ray data are compared with data from other diagnostics in order to discuss possible connection between sawtooth instability on one side and the transition to higher confinement mode, edge localized modes and productions of runaway electrons on the other side.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intense ion beam neutralization using underdense background plasma

Producing an overdense background plasma for neutralization purposes with a density that is high compared to the beam density is not always experimentally possible. We show that even an underdense background plasma with a small relative density can achieve high neutralization of intense ion beam pulses. Using particle-in-cell simulations, we show that if the total plasma electron charge is not sufficient to neutralize the beam charge, electron emitters are necessary for effective neutralization but are not needed if the plasma volume is so large that the total available charge in the electrons exceeds that of the ion beam. Several regimes of possible underdense/tenuous neutralization plasma densities are investigated with and without electron emitters or dense plasma at periphery regions, including the case of electron emitters without plasma, which does not effectively neutralize the beam. Over 95% neutralization is achieved for even very underdense background plasma with plasma density 1/15th the beam density. We compare results of particle-in-cell simulations with an analytic model of neutralization and find close agreement with the particle-in-cell simulations. Further, we show experimental data from the National Drift Compression experiment-II group that verifies the result that underdense plasma can neutralize intense heavy ion beams effectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control of thermal gradient using thermoelectric coolers for study of thermal effects

Thermoelectric coolers based on the Peltier effect have been utilized to control temperature gradient to study thermal effects in both bulk and thin film samples. The temperature gradient is controlled by two coolers and the polarity of the thermal gradient can be reversed by reversing an electric driven voltage. With appropriate controlled thermal gradient using this technique, the Nernst and the Seebeck effects can be measured in both bulk and thin film samples free of spurious contributions. In an arbitrary direction of thermal gradient, the Seebeck and the Nernst components can be decomposed from the measured signal based on the symmetry of the effects in a magnetic field.

47 OTHER INSTRUMENTATION↗

Selective deuterium ion acceleration using the Vulcan petawatt laser

We report on the successful demonstration of selective acceleration of deuterium ions by target-normal sheath acceleration (TNSA) with a high-energy petawatt laser. TNSA typically produces a multi-species ion beam that originates from the intrinsic hydrocarbon and water vapor contaminants on the target surface. Using the method first developed by Morrison et al. [Phys. Plasmas 19, 030707 (2012)], an ion beam with >99% deuterium ions and peak energy 14 MeV/nucleon is produced with a 200 J, 700 fs, >10{sup 20}W/cm{sup 2} laser pulse by cryogenically freezing heavy water (D{sub 2}O) vapor onto the rear surface of the target prior to the shot. Within the range of our detectors (0°–8.5°), we find laser-to-deuterium-ion energy conversion efficiency of 4.3% above 0.7 MeV/nucleon while a conservative estimate of the total beam gives a conversion efficiency of 9.4%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring correlated electronic and vibrational spectral dynamics using line shapes in two-dimensional electronic-vibrational spectroscopy

Two-dimensional electronic-vibrational (2DEV) spectroscopy is an experimental technique that shows great promise in its ability to provide detailed information concerning the interactions between the electronic and vibrational degrees of freedom in molecular systems. The physical quantities 2DEV is particularly suited for measuring have not yet been fully determined, nor how these effects manifest in the spectra. In this work, we investigate the use of the center line slope of a peak in a 2DEV spectrum as a measure of both the dynamic and static correlations between the electronic and vibrational states of a dye molecule in solution. We show how this center line slope is directly related to the solvation correlation function for the vibrational degrees of freedom. We also demonstrate how the strength with which the vibration on the electronic excited state couples to its bath can be extracted from a set of 2DEV spectra. These analytical techniques are then applied to experimental data from the laser dye 3,3′-diethylthiatricarbocyanine iodide in deuterated chloroform, where we determine the lifetime of the correlation between the electronic transition frequency and the transition frequency for the backbone C = C stretch mode to be ∼1.7 ps. Furthermore, we find that on the electronic excited state, this mode couples to the bath ∼1.5 times more strongly than on the electronic ground state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Size-dependent mechanical properties of Mg nanoparticles used for hydrogen storage

Magnesium (Mg) hydride is a promising hydrogen storage material, yet its application has been limited by the slow hydrogen sorption kinetics. Recently, Mg nanoparticles have shown significant improvement of hydrogen storage properties in terms of dimensional stability upon cycling with the trend that the smaller the particle, the better the sorption kinetics. Since the volume change during sorption generates stress, leading to plastic deformation, the fundamentals of the mechanical deformation of the Mg particles are a significant issue. By using in situ transmission electron microscope compression tests and atomistic simulations on Mg nanoparticles, it was observed that deformation in the larger particles was dominated by the nucleation of 〈a〉-type dislocations from stress concentrations at the contact surface, while the smaller particles deformed more homogeneously with greater distribution of multiple types of dislocation sources. Importantly, this improvement of plastic deformation with decrease in size is orientation-independent. First-principles calculations suggest that this improved plasticity can be explained by the nearly-isotropic ideal shear strength for Mg, which becomes more important in smaller nanoparticles. As a result, the smaller Mg nanoparticles demonstrated better plastic stability to accommodate volume change upon hydrogen storage cycling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging the inside of thick structures using cosmic rays

The authors present here a new method to image reinforcement elements inside thick structures and the results of a demonstration measurement performed on a mock-up wall built at Los Alamos National Laboratory. The method, referred to as “multiple scattering muon radiography”, relies on the use of cosmic-ray muons as probes. The work described in this article was performed to prove the viability of the technique as a means to image the interior of the dome of Florence Cathedral Santa Maria del Fiore, one of the UNESCO World Heritage sites and among the highest profile buildings in existence. Its result shows the effectiveness of the technique as a tool to radiograph thick structures and image denser object inside them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗