Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Level crossings, excess times, and transient plasma–wall interactions in fusion plasmas

Based on a stochastic model for intermittent fluctuations in the boundary region of magnetically confined plasmas, an expression for the level crossing rate is derived from the joint distribution of the process and its derivative. From this the average time spent by the process above a certain threshold level is obtained. This provides novel predictions of plasma–wall interactions due to transient transport events associated with a radial motion of blob-like structures in the scrape-off layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Communication: XUV transient absorption spectroscopy of iodomethane and iodobenzene photodissociation

Time-resolved extreme ultraviolet (XUV) transient absorption spectroscopy of iodomethane and iodobenzene photodissociation at the iodine pre-N{sub 4,5} edge is presented, using femtosecond UV pump pulses and XUV probe pulses from high harmonic generation. For both molecules the molecular core-to-valence absorption lines fade immediately, within the pump-probe time-resolution. Absorption lines converging to the atomic iodine product emerge promptly in CH{sub 3}I but are time-delayed in C{sub 6}H{sub 5}I. We attribute this delay to the initial π → σ{sup *} excitation in iodobenzene, which is distant from the iodine reporter atom. We measure a continuous shift in energy of the emerging atomic absorption lines in CH{sub 3}I, attributed to relaxation of the excited valence shell. An independent particle model is used to rationalize the observed experimental findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

About the parametrizations utilized to perform magnetic moments measurements using the transient field technique

The experimental study of nuclear magnetic moments, using the Transient Field technique, makes use of spin-orbit hyperfine interactions to generate strong magnetic fields, above the kilo-Tesla regime, capable to create a precession of the nuclear spin. A theoretical description of such magnetic fields is still under theoretical research, and the use of parametrizations is still a common way to address the lack of theoretical information. In this contribution, a review of the main parametrizations utilized in the measurements of Nuclear Magnetic Moments will be presented, the challenges to create a theoretical description from first principles will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Near interface traps in SiO{sub 2}/4H-SiC metal-oxide-semiconductor field effect transistors monitored by temperature dependent gate current transient measurements

This letter reports on the impact of gate oxide trapping states on the conduction mechanisms in SiO{sub 2}/4H-SiC metal-oxide-semiconductor field effect transistors (MOSFETs). The phenomena were studied by gate current transient measurements, performed on n-channel MOSFETs operated in “gate-controlled-diode” configuration. The measurements revealed an anomalous non-steady conduction under negative bias (V{sub G} > |20 V|) through the SiO{sub 2}/4H-SiC interface. The phenomenon was explained by the coexistence of a electron variable range hopping and a hole Fowler-Nordheim (FN) tunnelling. A semi-empirical modified FN model with a time-depended electric field is used to estimate the near interface traps in the gate oxide (N{sub trap} ∼ 2 × 10{sup 11} cm{sup −2}).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transient enhancement of magnetization damping in CoFeB film via pulsed laser excitation

Laser-induced spin dynamics of in-plane magnetized CoFeB films has been studied by using time-resolved magneto-optical Kerr effect measurements. While the effective demagnetization field shows little dependence on the pump laser fluence, the intrinsic damping constant has been found to be increased from 0.008 to 0.076 with the increase in the pump fluence from 2 mJ/cm{sup 2} to 20 mJ/cm{sup 2}. This sharp enhancement has been shown to be transient and ascribed to the heating effect induced by the pump laser excitation, as the damping constant is almost unchanged when the pump-probe measurements are performed at a fixed pump fluence of 5 mJ/cm{sup 2} after irradiation by high power pump pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Defect identification based on first-principles calculations for deep level transient spectroscopy

Deep level transient spectroscopy (DLTS) is used extensively to study defects in semiconductors. We demonstrate that great care should be exercised in interpreting activation energies extracted from DLTS as ionization energies. We show how first-principles calculations of thermodynamic transition levels, temperature effects of ionization energies, and nonradiative capture coefficients can be used to accurately determine actual activation energies that can be directly compared with DLTS. Our analysis is illustrated with hybrid-functional calculations for two important defects in GaN, which have similar thermodynamic transition levels and shows that the activation energy extracted from DLTS includes a capture barrier that is temperature dependent, unique to each defect, and, in some cases, large in comparison to the ionization energy. By calculating quantities that can be directly compared with the experiment, first-principles calculations thus offer powerful leverage in identifying the microscopic origin of defects detected in DLTS.

Activation energies↗

Solvent-dependent complex reaction pathways of bromoform revealed by time-resolved X-ray solution scattering and X-ray transient absorption spectroscopy

The photochemical reaction pathways of CHBr3 in solution were unveiled using two complementary X-ray techniques, time-resolved X-ray solution scattering (TRXSS) and X-ray transient absorption spectroscopy, in a wide temporal range from 100 ps to tens of microseconds. By performing comparative measurements in protic (methanol) and aprotic (methylcyclohexane) solvents, we found that the reaction pathways depend significantly on the solvent properties. In methanol, the major photoproducts are CH3OCHBr2 and HBr generated by rapid solvolysis of iso-CHBr2-Br, an isomer of CHBr3. In contrast, in methylcyclohexane, iso-CHBr2-Br returns to CHBr3 without solvolysis. In both solvents, the formation of CHBr2 and Br is a competing reaction channel. From the structural analysis of TRXSS data, we determined the structures of key intermediate species, CH3OCHBr2 and iso-CHBr2-Br in methanol and methylcyclohexane, respectively, which are consistent with the structures from density functional theory calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep level transient spectroscopy investigation of ultra-wide bandgap ($\bar201$) and ($001$) β -Ga 2 O 3

Here, this work reports on a comprehensive examination of the electrical and thermal properties of vertical Schottky diodes fabricated on ($\bar201$) and ($001$)-oriented samples of β-Ga 2 O 3 . The temperature-dependent current–voltage (I–V) and capacitance–voltage (C–V) data were gathered and analyzed down to 60 K. Deep level transient spectroscopy (DLTS) was used to study bulk and interface defects in the two materials from approx. 325 K down to 60 K. In the bulk ($\bar201$) material, an electron trap was observed at E C -0.46 eV, with a capture cross section of 1.6 x 10 -14 cm 2 and a lambda-corrected maximum trap density of 9.08 x 10 15 cm -3 . These results and others indicate that the electron trap is a strong candidate for the well-known E1 defect in β-Ga 2 O 3 based on recent investigations. Additionally, in the ($\bar201$) material, the smooth modulation typical of interface states is evident at temperatures below 275 K. The ($001$) samples manifested what is likely the E2* electron trap at E C -0.68 eV, with a capture cross section of 1.64 x 10 -15 cm 2 and a lambda-corrected maximum trap density of 8.85 x 10 15 cm -3 . The presence of the E2* defect, in particular, is a contrast to the findings of recent DLTS investigations on β-Ga 2 O 3 , which report that E2* emerged only after low-energy proton irradiation. These results help to further map out the defect signatures found in β-Ga 2 O 3 materials, which are of vital importance in the design and fabrication of future β-Ga 2 O 3 devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

Identification of the defect dominating high temperature reverse leakage current in vertical GaN power diodes through deep level transient spectroscopy

Deep level defects in wide bandgap semiconductors, whose response times are in the range of power converter switching times, can have a significant effect on converter efficiency. We use Deep Level Transient Spectroscopy (DLTS) to evaluate such defect levels in the n- drift layer of vertical GaN (v-GaN) power diodes with VBD ~ 1500 V. DLTS reveals three energy levels that are at ~0.6 eV (highest density), ~0.27 eV (lowest density) and ~ 45 meV (a dopant level) from the conduction band. Dopant extraction from Capacitance-Voltage measurement test (C-V) at multiple temperatures enables trap density evaluation, and the ~0.6 eV trap has a density of 1.2 × 10 15 cm -3 . Here, the 0.6 eV energy level and its density are similar to a defect that is known to cause current collapse in GaN based surface conducting devices (like HEMTs). Analysis of reverse bias currents over temperature in the v-GaN diodes indicates a predominant role of the same defect in determining reverse leakage current at high temperatures, reducing switching efficiency.

42 ENGINEERING↗

Asynchronous x-ray multiprobe data acquisition for x-ray transient absorption spectroscopy

Laser pump X-ray Transient Absorption (XTA) spectroscopy offers unique insights into photochemical and photophysical phenomena. X-ray Multiprobe data acquisition (XMP DAQ) is a technique that acquires XTA spectra at thousands of pump-probe time delays in a single measurement, producing highly self-consistent XTA spectral dynamics. In this work, we report two new XTA data acquisition techniques that leverage the high performance of XMP DAQ in combination with High Repetition Rate (HRR) laser excitation: HRR-XMP and Asynchronous X-ray Multiprobe (AXMP). HRR-XMP uses a laser repetition rate up to 200 times higher than previous implementations of XMP DAQ and proportionally increases the data collection efficiency at each time delay. This allows HRR-XMP to acquire more high-quality XTA data in less time. AXMP uses a frequency mismatch between the laser and x-ray pulses to acquire XTA data at a flexibly defined set of pump-probe time delays with a spacing down to a few picoseconds. AXMP introduces a novel pump-probe synchronization concept that acquires data in clusters of time delays. Further, the temporally inhomogeneous distribution of acquired data improves the attainable signal statistics at early times, making the AXMP synchronization concept useful for measuring sub-nanosecond dynamics with photon-starved techniques like XTA. In this paper, we demonstrate HRR-XMP and AXMP by measuring the laser-induced spectral dynamics of dilute aqueous solutions of Fe(CN) 6 4₋ and [Fe II (bpy) 3 ] 2+ (bpy: 2,2'-bipyridine), respectively.

47 OTHER INSTRUMENTATION↗

Analytical model for laser-induced transient grating measurements of thermal diffusivity in non-opaque materials

The thermal transport and elastic properties of materials are often measured using the laser-induced transient grating spectroscopy (TGS) technique. The analysis of the TGS signal usually involves fitting well-known expressions, derived assuming the limiting cases of opaque or transparent materials, to the measured data. In this paper, the system of thermoelastic equations is analytically solved for an isotropic homogeneous material assuming finite laser penetration depth, which is an important consideration when the penetration depth is on the order of the acoustic wavelength. The need to use such a solution is discussed and compared to the expression for opaque material. The solution is benchmarked against TGS signal measured on single-crystal silicon with {100} surface orientation and is found to significantly improve the accuracy of the calculated thermal diffusivity as compared to using the expression for opaque material.

36 MATERIALS SCIENCE↗

Modeling transient edge plasma transport with dynamic recycling

The work presents numerical simulation studies of the role that dynamic plasma recycling on the main wall and divertor target surfaces plays in transient edge plasma transport phenomena, such as edge localized modes (ELMs). The studies are performed by coupling the edge plasma transport code UEDGE [Rognlien et al., J. Nucl. Mater. 196–198, 347 (1992)] and the wall reaction–diffusion transport code FACE [Smirnov et al., Fusion Sci. Technol. 71, 75 (2017)]. The two-dimensional, time-dependent, two-way coupling of the codes, in a realistic tokamak geometry, is accomplished using the Integrated Plasma Simulator framework [Elwasif et al., in 18th Euromicro Conference on Parallel, Distributed and Network-Based Processing (PDP 2010), Pisa, Italy (IEEE, 2010), pp. 419–427] for all modeled material plasma boundaries. The simulations show that dynamic plasma recycling has substantially different characteristics on the main wall and on the divertor plates. It is demonstrated that during an ELM cycle the outer wall can dynamically absorb and release a number of particles comparable to that expelled by the ELM from the core plasma, by far exceeding the dynamic retention capacity of the divertor surfaces. The resulting evolution of the edge and divertor plasma conditions during an ELM cycle is analyzed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hiding in plain sight: The prevalence and impact of trions and Fermi polarons in transient absorption spectroscopy experiments of 2D semiconductors

Transient absorption (TA) spectroscopy is one of the most popular experimental methods to measure the excited state lifetimes and charge carrier recombination mechanisms in two dimensional (2D) semiconductors. This fundamental information is essential for designing and optimizing the next generation of ultrathin and lightweight 2D semiconductor-based optoelectronic devices. However, the interpretation of TA spectroscopy data varies across the community. The community lacks a unifying physical explanation for how and why experimental variables such as incident light intensity, sample-substrate interactions, and/or applied bias affect TA spectral data. This Perspective (1) compares the physical chemistry TA literature to nanomaterial physics literature from a historical perspective, (2) reviews multiple physical explanations that the TA community developed to explain spectral features and experimental trends, (3) provides a unifying explanation for how and why trions—and, more generally, Fermi polarons—contribute to TA spectra, and (4) quantifies the extent to which various physical interpretations and data analysis procedures yield different timescales and mechanisms for the same set of experimental results. We highlight the importance of considering trions/Fermi polarons in TA measurements and their implications for advancing our understanding of 2D material properties.

2D materials↗

Accelerating plasma and radiation surface science using transient grating spectroscopy

A facility for the investigation of in situ radiation-materials and plasma-materials interaction is demonstrated with tungsten, using transient grating spectroscopy as a probe of thermal diffusivity and surface acoustic wave speed. Helium plasma exposure at 645 °C to 1.18 × 10 18 cm −2 helium, until the growth of tungsten fuzz, showed an increase in surface acoustic wave speed at the near-surface from 2542 ± 1 m s −1 up to 2565 ± 1 m s −1 , followed by a greater drop to 2499 ± 7 m s −1 . No observable change in thermal diffusivity was present for plasma exposure alone. A separate 10.26 MeV self-ion-irradiation of tungsten to a dose of 7.92 dpa showed a reduction in both thermal diffusivity from 61.4 ± 1.4 mm 2 s −1 to 36.0 ± 0.7 mm 2 s −1 , following trends seen in existing studies, and surface acoustic wave speed from 2647.8 ± 0.6 m s −1 to 2640.0 ± 0.4 m s −1 . Facilities like these are poised to rapidly close critical knowledge gaps regarding the coupled effects of plasma and radiation damage for materials in fusion systems.

Accelerated plasmas↗

Decreasing the amplitude of macroscopic quantum fluctuations in the case of transient SRS

It is shown experimentally that, under the conditions of transient stimulated Raman scattering, pumping by two successive orthogonally polarised laser pulses makes it possible to reduce the amplitude of macroscopic quantum energy fluctuations of a Stokes pulse by a factor of 4 in comparison with single-shot pumping. An energy dispersion of 0.9 % for the first Stokes component is obtained in hydrogen at a relative energy dispersion of ytterbium laser pulses of 0.4 %. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser-induced transient magnons in Sr 3 Ir 2 O 7 throughout the Brillouin zone

Although ultrafast manipulation of magnetism holds great promise for new physical phenomena and applications, targeting specific states is held back by our limited understanding of how magnetic correlations evolve on ultrafast timescales. Using ultrafast resonant inelastic X-ray scattering we demonstrate that femtosecond laser pulses can excite transient magnons at large wavevectors in gapped antiferromagnets and that they persist for several picoseconds, which is opposite to what is observed in nearly gapless magnets. Overall, our work suggests that materials with isotropic magnetic interactions are preferred to achieve rapid manipulation of magnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dislocation theory of steady and transient creep of crystalline solids: Predictions for olivine

In applications critical to the geological, materials, and engineering sciences, deformation occurs at strain rates too small to be accessible experimentally. Instead, extrapolations of empirical relationships are used, leading to epistemic uncertainties in predictions. To address these problems, we construct a theory of the fundamental processes affecting dislocations: storage and recovery. We then validate our theory for olivine deformation. This model explains the empirical relationships among strain rate, applied stress, and dislocation density in disparate laboratory regimes. It predicts the previously unexplained dependence of dislocation density on applied stress in olivine. The predictions of our model for Earth conditions differ from extrapolated empirical relationships. For example, it predicts rapid, transient deformation in the upper mantle, consistent with recent measurements of postseismic creep.

36 MATERIALS SCIENCE↗