Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systems Performance Lab”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Modeling and Simulation of Tank Pressure Control using Zero-Boiloff Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Dynamic modeling and transient studies of a solid-sorbent adsorber for CO{sub 2} capture

The U.S. Department of Energy’s Carbon Capture Simulation Initiative (CCSI) is dedicated to accelerating the commercialization of carbon capture technologies from discovery to development, demonstration, and ultimately the widespread deployment to hundreds of power plants. In this multi-lab initiative in partnership with academic and industrial institutions, the National Energy Technology Laboratory (NETL) leads the development of a multi-scale modeling and simulation toolset for rapid evaluation and deployment of carbon capture systems. One element of the CCSI is focused on optimizing the operation and control of carbon capture systems since this can have a significant impact on the extent and the rate at which commercial-scale capture processes will be scaled-up, deployed, and used in the years to come. Capture processes must be capable of operating over a wide range of transient events, malfunctions, and disturbances, as well as under uncertainties. As part of this work, dynamic simulation and control models, methods, and tools are being developed for CO{sub 2} capture and compression processes and their integration with a baseline commercial-scale supercritical pulverized coal (SCPC) power plant. Solid-sorbent-based post-combustion capture technology was chosen as the first industry challenge problem for CCSI because significant work remains to define and optimize the reactors and processes needed for successful sorbent capture systems. Sorbents offer an advantage because they can reduce the regeneration energy associated with CO{sub 2} capture, thus reducing the parasitic load. In view of this, the current paper focuses on development of a dynamic model of a solid-sorbent CO{sub 2} adsorber-reactor and an analysis of its transient performance with respect to several typical process disturbances. A one-dimensional, non-isothermal, pressure-driven dynamic model of a two-stage bubbling fluidized bed (BFB) adsorber-reactor is developed in Aspen Custom Modeler (ACM). The BFB stages are of overflow-type configuration where the solids leave the stage by flowing over the overflow-weir. Each bed is divided into three regions, namely emulsion, bubble, and cloud-wake regions. In all three regions, the model considers mass and energy balances. Along with the models of the BFB stages, models of other associated hardware are developed and integrated in a single flowsheet. A valid pressure-flow network is developed and a lower-level control system is designed so that the overall CO{sub 2} capture can be maintained at a desired level in face of the typical disturbances. The dynamic model is used for studying the transient responses of a number of important process variables as a result of the disturbances that are typical of post-combustion CO{sub 2} capture processes.

20 FOSSIL-FUELED POWER PLANTS↗

The Sensor Dilemma in Intelligent Transportation Systems

Intelligent Transportation Systems (ITS) are at the forefront in advancing the way we interact and perceive with the transportation network. This revolution is fueled by the significant advancement in sensor perception technologies such as Radar, LiDAR and Video Imaging which are the most popular modalities for ITS. Real-time perception data from these sensors allows intelligent infrastructure side decision making to improve the energy, efficiency and safety at traffic intersections. As traffic departments across the United States are transitioning from traditional loop detectors / emulators and embracing newer technologies, they are often left with a dilemma in choosing a sensor technology for infrastructure-based perception which is reliable, inexpensive, easy to setup and has robust performance in varying weather conditions. However, choosing a sensor which checks all boxes is not straightforward as every sensor type has unique benefits and drawbacks. Radar is excellent at detecting long range vehicles and weather resistance but lacks high resolution. LiDAR is expensive and weather-sensitive, while cameras provide rich visual data at a low cost but are constrained by lighting and visibility. This study examines Radar, LiDAR and camera sensors capabilities to ascertain whether any of these qualifies as the "best" sensor for ITS perception. Through this evaluation, we hope to draw attention to the necessity of National Renewable Energy Laboratory's (NREL) Infrastructure Perception and Control (IPC) framework which presents a multi-sensor track data fusion engine to assimilate multiple data streams in order to provide robust and reliable perception. While no single sensor can meet all the demands of ITS, a hybrid approach combining multiple sensor modalities like Radar, LiDAR and cameras, offers the most robust solution for enhancing the safety and efficiency in intelligent transportation systems.

33 ADVANCED PROPULSION SYSTEMS↗

Multi-physics Preconditioning for Thermally Activated Batteries

Thermal batteries, also known as molten-salt batteries, are single-use reserve power systems activated by pyrotechnic heat generation, which transitions the solid electrolyte into a molten state. The simulation of these batteries relies on multiphysics modeling to evaluate performance and behavior under various conditions. This paper presents advancements in scalable preconditioning strategies for the Thermally Activated Battery Simulator (TABS) tool, enabling efficient solutions to the coupled electrochemical systems that dominate computational costs in thermal battery simulations. We propose a hierarchical block Gauss-Seidel preconditioner implemented through the Teko package in Trilinos, which effectively addresses the challenges posed by tightly coupled physics, including charge transport, porous flow, and species diffusion. The preconditioner leverages scalable subblock solvers, including smoothed aggregation algebraic multigrid (SA-AMG) methods and domain-decomposition techniques, to achieve robust convergence and parallel scalability. Strong and weak scaling studies demonstrate the solver’s ability to handle problem sizes up to 51.3 million degrees of freedom on 2048 processors, achieving near sub-second setup and solve times for the end-to-end electrochemical solve. These advancements significantly improve the computational efficiency and turnaround time of thermal battery simulations, paving the way for higher-resolution models and enabling the transition from 2D axisymmetric to full 3D simulations.

25 ENERGY STORAGE↗

THE USE OF DI WATER TO MITIGATE DUSTING FOR ADDITION OF DWPF FRIT TO THE SLURRY MIX EVAPORATOR

The Defense Waste Processing Facility (DPWF) presently is in the process to determine means to reduce water utilization in the Slurry Mix Evaporator (SME) process, thus reducing effluent and processing times. The frit slurry addition system mixes the dry frit with water, yielding approximately a 50 weight percent slurry containing frit and the other fraction water. This slurry is discharged into the SME and excess water is removed via boiling. To reduce this water load to the SME, DWPF has proposed using a pneumatic system in conveying the frit to the SME, in essence a dry delivery system. The problem associated with utilizing a dry delivery system with the existing frit is the generation of dust when discharged into the SME. The use of water has been shown to be effective in the mining industry as well in the DOE complex to mitigate dusting. The method employed by SRNL to determine the quantity of water to mitigate dusting in dry powders was effective, between a lab and bench scale tests. In those tests, it was shown that as high as five weight percent (wt%) of water addition was required to mitigate dust from batches of glass forming minerals used by the Waste Treatment Plant at Hanford, Washington. The same method used to determine the quantity of water to mitigate dusting was used in this task to determine the quantity of water to mitigate this dusting using as-received frit. The ability for water to mitigate dusting is due to its adhesive properties as shown in Figure 1-1. Wetting the frit particles allows for the smaller frit particles (including dust) to adhere to the larger frit particles or to agglomerate into large particles. Fluids other than water can also be used, but their adhesive properties are different than water and the quantity required to mitigate dusting is different, as was observed in reference 1. Excessive water, a few weight percentages greater than that required to mitigate dusting can cause the resulting material not to flow. The primary objective of this task is to perform bench scale testing on various frits that have been used at DWPF or in test programs at SRNL to determine the quantity of de-ionized (DI) water required to mitigate dusting per mass basis of frit. The quantity of DI water required was determined visually by observing the effluent port of the mixer, and DI water addition was made to the point where no visible dust was observed leaving the effluent port. A total of eight different frits were selected for testing. Secondary objectives in this task include the following: (1) Video taping of the de-dusting procedure, (2) Particle size distribution analyses of the dry and wetted frits at the weight fraction of water required for de-dusting, (3) Plate flow tests to determine angle of flow and quantity of material remaining on plate at 90 degrees, (4) Microscopy of dry and wetted frit, and (5) Effect of excess water for selected frits on plate flow. The above analyses were performed within one hour of water addition, to minimize the effect of evaporative water losses. To better understand the size of dust particles, perform settling tests on selected frits and capture the fines. Analyze the fines for particle size distribution. Finally, it is expected that the surface area of frit is an important parameter in the quantity of water required for dust mitigation. An analysis of particle size distribution (PSD) data of as-received frit analyzed by SRNL over the past two to three years will be performed to determine the variation in the distribution of as-received frit. The following objectives were stated in the Technical Task Request4 as objectives that given adequate time would provide insight in helping DWPF in assessing equipment or processes for de-dusting and processing of dry frit. Due to time constraints, commercial methods for dedusting are provided. These results are detailed in section 3.7. Obtain design information from Hanford with respective to equipment used for dedusting. Suggestions on enhanced design features, such as flush water, pipe air purges, humidified compressed air, options for agitation, and other base (SRNL) knowledge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Building and Commissioning of the Batch Pyrolysis Plant in Studsvik, Sweden - 12447

After a sequence of lab scale and bench scale trials the building of a pyrolysis plant could begin at the Studsvik site in Sweden. The facility is primarily aimed at treatment of uranium contaminated organic waste originating at fuel manufacturing plants and other facilities where the main contamination is uranium. The plant is an extension/addition to the already operating incinerator. In order to further widen the waste acceptance criteria the design of the off-gas treatment system does not have the same design as that of the incinerator. The building of the facility began in April 2011, and the first heating of the facility took place in late December, 2011. The site acceptance tests are planned for January, as are the first inactive trials aimed at optimisation of process control. The facility is planned to be operating with radioactive materials from February 2012. The pyrolysis unit is primarily aimed at treatment of uranium contaminated waste, under conditions that facilitate leaching and recovery of the uranium from the ashes. However, a number of other uses are conceivable. The batch fed pyrolysis unit, with its chosen design of the off-gas treatment system, enables treatment of some waste fractions that are difficult to treat in the incinerator. For instance small campaigns, i.e. smaller quantities of waste (typically <5 tonnes), or waste containing high levels of chlorine and sulphur are possible to treat in the pyrolysis unit. The pyrolysis unit is also expected to perform well in the treatment of other 'difficult' waste fractions, for instance waste containing pyrophoric materials, or other types of waste that benefit from the high level of process control, i.e. control of temperature and atmosphere throughout the process, that can be obtained in the pyrolysis unit compared to the incinerator. Furthermore, treatment in the pyrolysis unit minimises the risk of cross contamination between different waste treatment campaigns. This feature is obtained thanks to the low gas flow rates in the vessel, which means that a higher retention of nuclides in the ashes is obtained, but also through a design that facilitates cleaning of the pyrolysis vessel and the system beyond this, or even exchanging the most critical components, such as the pyrolysis vessel itself, if need be. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hazard and Operability Study for the Ammonia Fuel Systems at the National Transportation Research Center

Oak Ridge National Laboratory’s (ORNL’s) Buildings and Transportation Science Division (BTSD) plans to operate research engines fueled by ammonia in two engine test cells at the National Transportation Research Center (NTRC). A scientific need has recently emerged to evaluate the suitability of liquid anhydrous ammonia as a low-lifecycle-carbon fuel source for difficult-to-electrify transportation sectors, including the marine sector. Therefore, BTSD plans to install an ammonia storage and delivery system to 2360 HVC engine research labs L125 (Cell 3) and L111 (Cell 7) capable of delivering 35 and 75 lb/h, respectively. These laboratories are specifically designed to allow for engine and fuels research and development, and they have existing safety systems for mitigating risks associated with toxics and flammables. Anhydrous ammonia is toxic and flammable, and the system will use relatively large quantities compared with standard gas bottles. Ammonia is one of the most widely produced chemicals in the world, and the hazards associated with toxicity and flammability are well understood. Ammonia storage for use in engine research at NTRC is anticipated to take the form of an ammonia tank with capacity of 1,000 water gallons; this quantity will remain below the threshold quantity of 10,000 lb (~2,000 gal) used both by the US Environmental Protection Agency for reporting under the Emergency Planning and Community Right to Know Act and for Risk Management Program requirements, and also by the US Occupational Safety and Health Administration for Process Safety Management requirements. ORNL’s Environmental Protection Services Division was also consulted to verify that the quantities of ammonia anticipated to be used would be in compliance with environmental regulations. The Environmental Protection Services Division staff confirmed that the anticipated quantities fall below ORNL’s permit thresholds. However, because of the hazards associated with anhydrous ammonia, the quantities to be used, and the limited experience with similar quantities of ammonia at ORNL, BTSD decided to perform a hazard and operability (HazOp) study on the ammonia storage and delivery system.

33 ADVANCED PROPULSION SYSTEMS↗

Detecting isolated resonance curves using fixed frequency voltage control tests

Isolated resonance curves, or isolas, are resonance branches of the harmonically forced system that exist separately from the main nonlinear forced response curve, leading to excessive vibrations. Traditional stepped or swept sine simulations and tests rely on continuation along the frequency parameter, typically resulting in a jump phenomenon along the primary resonance branch, prior to the disconnected isola. The main objective of this research is to propose an approach to identify isolated resonance curves by performing continuation along the input amplitude that initializes the response from a low-amplitude solution in the linear regime. Furthermore, this is achieved with the open-loop fixed frequency voltage control method that continues along the shaker voltage parameter and measures the so-called S-curves, which are theoretically a continuous solution branch that connect to the isola. The methodology is demonstrated on a fixture-wing-pylon assembly with a vibro-impact nonlinearity localized in a pylon subcomponent attachment. Multi-harmonic balance simulations are deployed to compute both the nonlinear forced response curves and S-curves to demonstrate the isola detection strategy on a reduced-order finite element model of the nonlinear system. Swept sine and fixed frequency voltage control tests are then conducted on the physical structure to demonstrate the isola detection experimentally, revealing the existence of the large amplitude vibrations that are undetected in the forces levels and frequencies measured with traditional frequency sweeping.

Characterization and Analytical Technique↗

Demonstrating magnetic field robustness and reducing temporal T1 noise in transmon qubits through magnetic field engineering

The coherence of superconducting transmon qubits is often disrupted by fluctuations in the energy relaxation time (T1), limiting their performance for quantum computing. While background magnetic fields can be harmful to superconducting devices, we demonstrate that both trapped magnetic flux and externally applied static magnetic fields can suppress temporal fluctuations in T1 without significantly degrading its average value or qubit frequency. Using a three-axis Helmholtz coil system, we applied calibrated magnetic fields perpendicular to the qubit plane during cooldown and operation. Remarkably, transmon qubits based on tantalum-capped niobium (Nb/Ta) capacitive pads and aluminum-based Josephson junctions (JJs) maintained T1 lifetimes near 300 μs even when cooled in fields as high as 600 mG. Both trapped flux up to 600 mG and applied fields up to 400 mG reduced T1 fluctuations by more than a factor of two, while higher field strengths caused rapid coherence degradation. We attribute this stabilization to the polarization of paramagnetic impurities, the role of trapped flux as a sink for non-equilibrium quasiparticles (QPs), and partial saturation of fluctuating two-level systems (TLSs). These findings challenge the conventional view that magnetic fields are inherently detrimental and introduce a strategy for mitigating noise in superconducting qubits, offering a practical path toward more stable and scalable quantum systems.

Abdisatarov, Bektur [Fermilab; Jefferson Lab]↗

High Temperature Syngas Cleanup Technology Scale-up and Demonstration Project

Gasification is a technology for clean energy conversion of diverse feedstocks into a wide variety of useful products such as chemicals, fertilizers, fuels, electric power, and hydrogen. Existing technologies can be employed to clean the syngas from gasification processes to meet the demands of such applications, but they are expensive to build and operate and consume a significant fraction of overall parasitic energy requirements, thus lowering overall process efficiency. RTI International has developed a warm syngas desulfurization process (WDP) utilizing a transport-bed reactor design and a proprietary attrition-resistant, high-capacity solid sorbent with excellent performance replicated at lab, bench, and pilot scales. Results indicated that WDP technology can improve both efficiency and cost of gasification plants. The WDP technology achieved ~99.9% removal of total sulfur (as either H 2 S or COS) from coal-derived syngas at temperatures as high as 600°C and over a wide range of pressures (20-80 bar, pressure independent performance) and sulfur concentrations. Based on the success of these tests, RTI negotiated a cooperative agreement with the U.S. Department of Energy for precommercial testing of this technology at Tampa Electric Company’s Polk Power Station IGCC facility in Tampa, Florida. The project scope also included a sweet water-gas-shift process for hydrogen enrichment and an activated amine process for 90+% total carbon capture. Because the activated amine process provides some additional non-selective sulfur removal, the integration of these processes was expected to reduce overall sulfur in the syngas to sub-ppmv concentrations, suitable for most syngas applications. The overall objective of this project was to mitigate the technical risks associated with the scale up and integration of the WDP and carbon dioxide capture technologies, enabling subsequent commercial-scale demonstration. The warm syngas cleanup pre-commercial test unit was designed and constructed on schedule and under budget and was operated for approximately 1,500 total hours utilizing ~20% of the IGCC’s total syngas as feed (~1.5 MM scfh of dry syngas). The WDP system reduced total sulfur levels to ~10 ppmv (~99.9% removal) from raw syngas that contained as high as 14,000 ppmv of total sulfur. The integration of WDP with the activated amine process enabled further reduction of total sulfur in the final treated syngas to the anticipated sub-ppmv concentrations (>99.99% removal), suitable for stringent syngas applications such as chemicals, fertilizers, and fuels. Techno-economic assessments by RTI and by third parties indicate potential for significant (up to 50%) capital and operating cost reductions for the entire syngas cleanup block when WDP technology is integrated with a broad spectrum of conventional and emerging carbon capture or acid gas removal technologies. This final scientific/technical report covers the pre-FEED, FEED, EPC, commissioning, and operation phases of this project, as well as system performance results. In addition, the report addresses other parallel-funded R&D efforts focused on development and testing of trace contaminant removal process (TCRP) sorbents, a direct sulfur recovery process (DSRP), and a novel sorbent for warm carbon dioxide capture, as well as pre-FEED, FEED, and techno-economic studies to consider the potential benefit for use of WDP for polygeneration of electric power and ammonia/urea fertilizers.

01 COAL, LIGNITE, AND PEAT↗

Demonstrating Load-Shaping Capabilities of Cost Minimizing Heat Pump Water Heater Controls with Varying Price Profiles

Increased penetration of photovoltaics and electrification of traditionally gas appliances are exacerbating existing challenges in cost-effectively balancing electricity grid supply and demand. Decarbonization without incurring expensive transmission and distribution system capacity increases requires shifting building loads from peak demand times to peak renewable production times. Grid operators are evaluating new ways of encouraging load shifting, including using time-varying price structures to provide a financial incentive. If devices incorporate price-responsive controls, a price profile could be designed to yield a wide variety of load curves as needed to optimize grid functionality. Heat pump water heaters (HPWHs) are an ideal device for price-responsive controls because the storage tank enables them to optimize the timing of electricity consumption without impacting hot water delivery service. This paper presents work demonstrating how price-responsive controls for HPWHs can provide different load profiles, as needed to stabilize the grid, in response to different price profiles. HPWH manufacturers now include web API and CTA-2045 communication capabilities which enable sending load shaping control signals. Pilot studies and preliminary programs have utilized these capabilities with uniform control strategies to reduce 4-9 PM electricity consumption. However, no studies have developed flexible controls capable of both a) responding to constantly varying price profiles and b) customizing logic to match the needs of each HPWH. Berkeley Lab's CalFlexHub project is pioneering price-driven load flexibility by developing and deploying cost-minimizing controls utilizing setpoint setting signals for fleets of HPWHs in response to varying price profiles. Control development is based on simulations using the Flexible Heat Pump Water Heater Performance Predictor which captures the control decisions of a residential, integrated HPWH manufacturer’s on-board controller. The proposed cost-reducing controls respond to constantly changing price profiles, providing the ability to change the price profile to generate load curves as needed to maintain grid stability. Preliminary simulations studying the load shaping capabilities of price-responsive controls on a fleet of 60 HPWHs have demonstrated an average of a) 135.4% increases in load during low-price periods, b) >36.8% reductions in electricity peak-price period, and c) 6.2% electricity cost savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bacterial Communities of Diverse Drosophila Species: Ecological Context of a Host–Microbe Model System

Drosophila melanogaster is emerging as an important model of non-pathogenic host–microbe interactions. The genetic and experimental tractability of Drosophila has led to significant gains in our understanding of animal–microbial symbiosis. However, the full implications of these results cannot be appreciated without the knowledge of the microbial communities associated with natural Drosophila populations. In particular, it is not clear whether laboratory cultures can serve as an accurate model of host–microbe interactions that occur in the wild, or those that have occurred over evolutionary time. To fill this gap, we characterized natural bacterial communities associated with 14 species of Drosophila and related genera collected from distant geographic locations. To represent the ecological diversity of Drosophilids, examined species included fruit-, flower-, mushroom-, and cactus-feeders. In parallel, wild host populations were compared to laboratory strains, and controlled experiments were performed to assess the importance of host species and diet in shaping bacterial microbiome composition. We find that Drosophilid flies have taxonomically restricted bacterial communities, with 85% of the natural bacterial microbiome composed of only four bacterial families. The dominant bacterial taxa are widespread and found in many different host species despite the taxonomic, ecological, and geographic diversity of their hosts. Both natural surveys and laboratory experiments indicate that host diet plays a major role in shaping the Drosophila bacterial microbiome. Despite this, the internal bacterial microbiome represents only a highly reduced subset of the external bacterial communities, suggesting that the host exercises some level of control over the bacteria that inhabit its digestive tract. Finally, we show that laboratory strains provide only a limited model of natural host–microbe interactions. Bacterial taxa used in experimental studies are rare or absent in wild Drosophila populations, while the most abundant associates of natural Drosophila populations are rare in the lab.

59 BASIC BIOLOGICAL SCIENCES↗

Continuation of the University of Michigan Sounding Rocket Program

This interim report gives the activity on this grant through 31 October 1998, and the planned activities for the next fiscal year. A Project Initiation Conference (PIC) was held at the Wallops Flight Facility (WFF), with planning for the launch of flight 36.174 in Fall 1998. However, following the PIC, the WFF personnel decided that the experiment telemetry system had to be completely rewired, which required substantial design and wiring changes on the experiment side of the payload. These costs had not been anticipated in the FY98 budget, and used up considerable resources of the experimenters. In addition, the telemetry re-design was not completed until Fall 1998, so that there was no opportunity for a launch in 1998 (the Jupiter window closes in late November 1998 and it will reopen in late summer 1999). A Design Review was held by telecon with WFF personnel on 26 October 1998, with plans for the 36.174 launch now in late August 1999 with a launch window which extends into winter 2000. On a more positive note, we have been developing a vacuum UV calibration chamber in Michigan's Space Physics Research Lab, for future measurements of our experiment components, and this facility is now undergoing initial measurements of various calibration lamps in preparation for testing of the telescope UV reflective efficiency. This facility will greatly increase our ability to optimize our experiment for UV efficiency, which has been lacking in the past, and it will be made available for support of other NASA missions at Michigan and for visitors from other institutions. For the next flight 36.174, the following activities will be accomplished: (1) prepare the experiment, including replacement and upgrading of critical components, at University of Michigan; (2) pre-integrate the payload at the Wallops Flight Facility; (3) perform final far-UV calibration of instrument (4) perform final alignment, integration, and electrical checks at WSMR; (5) launch payload from WSMR and check condition of recovered payload; (6) perform post-flight calibration, if necessary and applicable (7) reduce and analyze flight data. The following pages contain information from the experimenter package for the Design Review for the next flight, 36.174, listing the plans, changes, and schedule for this flight.

Clarke, John↗

Experimental Studies on the Effect of Impact Processes on the Formation and Evolution of Amino Acids

Introduction: A critical step in the emergence of life on Earth was the synthesis of larger organic molecules from simple building blocks such as NH3, CO2, H2O, and CH3OH. The presence of amino acids and other complex organics in comets and meteorites demonstrates that widespread organic synthesis likely occurred across the early solar system. Building on previous work [e.g., 1-3], we systematically explore impact-driven chemical evolution of exogenous organics and their precursors. Collisional processes may also have provided a source of energy for the formation of more complex organics from endogenous building blocks. The high flux of impactors to Earth immediately prior to and during the origins of life suggests that impacts could have played a critical role. Key Questions: 1. How are the formation and evolution of amino acids affected by the presence of a mineral matrix during cometary and asteroidal impacts onto the early Earth? 2. Do some minerals (e.g., phyllosilicates) provide a more robust protective framework or reactive surface site for amino-acid formation and/or polymerization? 3. Does the abundance of ices and/or amino acids relative to that of the mineral matrix affect the formation and evolution of amino acids? 4. Are there impact velocities/shock pressures at which formation or polymerization of amino acids is favored or precluded? Experimental Approach: This study systematically examines the conditions under which amino acids and other organic molecules can form, be polymerized, and/or be destroyed during impact events into particulate regolith simulants. Variable parameters include the modal composition of this regolith (silicate matrices, ratios of ices, silicates, and amino acids) and impact velocities/shock pressures. Impacts experiments were performed using the two-stage light-gas gun (LGG), vertical gun (VG), and flat-plate accelerator (FPA) in the Experimental Impact Lab at JSC. FPA experiments were performed over a range of shock pressures (11.3-31.5 GPa) using CM chondrite simulant mixed with amino acids at ratios of 0:10, 1:10, 1:103, and 1:106 (amino acid:host). Techniques for mixing cometary ices have been optimized and test runs have been performed using the LGG (see figure below). Analysis: Post-impact, samples are heated in water to extract amino acids and peptides. Extracts are characterized via liquid chromatography-mass spectrometry (LC-MS) and the mineralogies of solid residues are characterized using X-ray diffraction, scanning electron microscopy and transmission electron microscopy. Additional LC-MS and mineralogical analyses are underway.

Eve L Berger↗

Sediment Properties: E-Area Completion Project

To accommodate a future need for additional waste disposal facilities at the Savannah River Site, the Solid Waste Management Division (SWMD) designated nine additional plots for development (Kasraii 2007; SRS 2010); these plots are collectively known as the E Area Completion Project (ECP). Subsurface samples were collected from ECP plots 6, 7, 8 and 9 (Figure 1) for chemical and physical property analyses to support Performance Assessment (PA) and Special Analyses (SA) modeling. This document summarizes the sampling and analysis scheme and the resultant data, and provides interpretations of the data particularly in reference to existing soil property data. Analytical data in this document include: gamma log, cone penetrometer log, grain size (sieve and hydrometer), water retention, saturated hydraulic conductivity (falling head permeameter), porosity, dry bulk density, total organic carbon, x-ray diffraction, and x-ray fluorescence data. SRNL provided technical and safety oversight for the fieldwork, which included completion of eight soil borings, four geophysical logs, and the collection of 522 feet of core and 33 Shelby tubes from ECP plots 6, 7, 8, and 9. Boart Longyear provided sonic drilling and logging services. Two soil borings were completed at each location. The first set of boreholes extended into (but did not fully penetrate) the Warley Hill Formation. These boreholes were continuously cored, then geophysically (gamma ray) logged. The recovered core was split, photographed, and described; one half of the core was archived at SRS's Core Lab facilities, and the remaining half was consumed as necessary for testing at SRS and off-site labs. Core descriptions and geophysical data were used to calculate target elevations for Shelby tube samples, which were obtained from the second set of boreholes. Shelby tubes were shipped to MACTEC Engineering and Consulting Inc. (MACTEC) in Atlanta for physical property testing. SRNL deployed their Site Characterization and Analysis Penetrometer System (SCAPS) cone penetrometer test (CPT) truck at ECP plots 6, 7, 8 and 9 to collect inferred lithology data for the vadose zone. Results from this study are used to make recommendations for future modeling efforts involving the ECP plots. The conceptual model of the ECP hydrogeology differs from the conceptual model of the current ELLWF disposal area in that for the ECP plots, the topography (ground surface) is generally lower in elevation; The Upland and top of Tobacco Road lithostratigraphic units are missing (eroded); The water table occurs lower in elevation (i.e., it occurs in lower stratigraphic units); and the Tan Clay Confining Zone (TCCZ) often occurs within the vadose zone (rather than in the saturated zone). Due to the difference in the hydrogeology between the current ELLWF location and the ECP plots, different vadose zone properties are recommended for the ECP plots versus the properties recommended by Phifer et al. (2006) for the current disposal units. Results from this study do not invalidate or conflict with the current PA's use of the Upper and Lower Vadose Zone properties as described by Phifer et al. (2006) for the current ELLWF disposal units. The following modeling recommendations are made for future modeling of the ECP plots where vadose zone properties are required: (1) If a single vadose zone property is preferred, the properties described by Phifer et al. (2006) for the Upper Vadose Zone encompass the general physical properties of the combined sands and clays in the ECP vadose zone sediments despite the differences in hydrostratigraphic units. (2) If a dual zone system is preferred, a combination of the Lower Zone properties and the Clay properties described by Phifer et al. (2006) are appropriate for modeling the physical properties of the ECP vadose zone. The Clay properties would be assigned to the Tan Clay Confining Zone (TCCZ) and any other significant clay layers, while the Lower Zone properties would be assigned for the remainder of the vadose zone. No immediate updates or changes are recommended for the saturated zone properties for modeling of the ECP plots. The hydrogeology and saturated hydraulic conductivity values resulting from the ECP work are consistent with existing data for the area. The following recommendations are provided for consideration in future work: (1) When the database is next updated, we recommend checking/refining hydrostratigraphic interpretations (picks) in addition to revising physical property data for both the vadose zone and saturated zone. (2) Results from this work suggest that separate ECP vadose zone properties may be appropriate for the various ECP plots. Consideration should be given to the fact that the plots toward the northwest (ECP plots 6, 7 and 8) all have the TCCZ within the vadose zone whereas the TCCZ occurs within the saturated zone to the east (ECP plot 9). (3) Further data may be needed at ECP plot 7.

54 ENVIRONMENTAL SCIENCES↗

Complete Iodine Loading of NO-Aged Ag 0 -Functionalized Silica Aerogel (Milestone Report)

In off-gas treatment systems within a nuclear fuel reprocessing plant, capture materials will be exposed to a gas stream for extended periods during their lifetime. This gas stream may be at elevated temperature and could contain water, NO x gas, or a variety of other constituents. For this reason, it is important to understand the effects of long-term exposure, or aging, on proposed capture materials. One material under consideration for iodine sequestration is silver-functionalized silica aerogel (Ag 0 -aerogel). The aim of this study was to determine the effect of extended exposure at 150°C to an air stream containing NO on the iodine capture capacity of Ag 0 -aerogel. Ag 0 -aerogel was provided by the Pacific Northwest National Laboratory (PNNL), which manufactures the material at a lab scale. Prior to aging, the material has an iodine loading capacity of approximately 290 mg I/g Ag 0 -aerogel. Previous studies have aged the material in a dry air stream or in a moist air stream for up to 6 months. Both tests resulted in a 22% loss in iodine capacity. Aging the material in a static 2% NO 2 environment for up to 2 months results in a 15% loss of iodine capacity.3 In this study, exposure of Ag 0 -aerogel to 1% NO at 150°C for 2 months produced a loss of 43% in iodine loading capacity. This is largest loss observed for aerogel aging studies to date. The performance of Ag 0 -aerogel in this study was compared to the performance of reduced silver mordenite (Ag 0 Z) in similar studies. Ag 0 Z is a zeolite mineral considered to be the current standard technology for iodine removal from off-gas streams of a potential US used fuel processing plant. In an aging study exposing Ag 0 Z to 1% NO for 2 months, an iodine capacity loss of over 80% was observed. This corresponds to a silver utilization of 13.5% for 2 month NO-aged Ag 0 Z, compared to 57% silver utilization for 2 month NO-aged aerogel. While iodine loading capacity and silver utilization are critical parameters in evaluating these materials, other properties must also be considered when selecting the appropriate material (e.g., relative material densities and potential waste form production technology). The resistance of Ag 0 -aerogel to NO is promising, and investigations of this material for use in iodine capture should continue to be pursued.

36 MATERIALS SCIENCE↗

Optimization of Energy Storage System Economics and Controls by Incorporating Battery Degradation Costs in REopt

The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.

battery↗

Nonlinear programming optimization of a single-stack electrodialysis desalination system for cost efficiency

Electrodialysis (ED) presents a competitive method for desalinating brackish waters. In this work, we perform cost optimization of a single-stack ED system across a range of feed salinities and water recoveries while optimizing operating voltage, number of cell pairs, and cell length. The results of our optimization show that the levelized cost of water (LCOW) increases with an increase in feed salinity. The outcomes of our optimization show that cost-optimal design generally increases cell length while decreasing cell pair number and operating voltage with an increase in salinity. These trends are nonlinear, with the number of cell pairs and applied voltage exhibiting local maxima when operating at low salinity and high recovery. We discuss the underlying mechanism for cell length becoming a leveraging design parameter by inspecting the length-dependent profiles of key electrochemical properties of the ED cell. Finally, we present how increasing performance metrics and decreasing costs impact LCOW, demonstrating that innovations that decrease counter-current diffusion have resulted in the highest decrease of LCOW.

42 ENGINEERING↗