Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Surface Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Discrimination of Seismic Events (2006–2020) in North Korea Using P/Lg Amplitude Ratios from Regional Stations and a Bivariate Discriminant Function

Two events of magnitude (m b ) 3.6–3.8 occurred in southern North Korea (NK) on 27 June 2019 and 11 May 2020. Although these events were located ~330–400 km from the known nuclear test site, the fact that they occurred within the territory of NK, a country with a recent history of underground nuclear tests, made them events of interest for the monitoring community. In this work, we used P/Lg ratios from regional stations to categorize seismic events that occurred in NK from 2006 to May 2020, including these two recent events, the six declared NK nuclear tests, and the cavity collapse and triggered earthquakes that followed the 3 September 2017 nuclear explosion. We were able to separate the cavity collapse from the population of nuclear explosions. However, based on P/Lg ratios, the distinction between the earthquakes and the cavity collapse is ambiguous. The performed discriminant analyses suggest that combining Pg/Lg and Pn/Lg ratios results in improved discriminant power compared with any of the ratio types alone. We used the two ratio types jointly in a quadratic discriminant function and successfully classified the six declared nuclear tests and the triggered earthquakes that followed the September 2017 explosion. Our analyses also confirm that the recent southern events of June 2019 and May 2020 are both tectonic earthquakes that occurred naturally.

58 GEOSCIENCES↗

The Seismic Signature of a High-Energy Density Physics Laboratory and Its Potential for Measuring Time-Dependent Velocity Structure

The Z Machine at Sandia National Laboratories is a pulsed power facility for high-energy density physics experiments that can shock materials to extreme temperatures and pressures through a focused energy release of up to ~ 25 MJ in < 100 nanoseconds. It has been in operation for more than two decades and conducts up to ~ 100 experiments, or “shots,” per year. Based on a set of 74 known shot times from 2018, we determined that Z Machine shots produce detectable ~ 3–17 Hz ground motion 12 km away at the Albuquerque Seismological Laboratory, New Mexico (ANMO), borehole seismograph, with peak signal at ~ 7 Hz. The known shot waveforms were used to create a three-component template, leading to the detection of 2339 Z Machine shots since 1998 through single-station cross-correlation. Local seismic magnitude estimates range from local magnitude (M L ) —2 to —1.3 and indicate that only a small fraction of the shot energy is transmitted by seismic phases observable at 12 km distance. The most recent major facility renovation, which was intended to decrease mechanical dissipation, is associated with an abrupt decrease in observed seismic amplitudes at ANMO despite stable maximum shot energy. The highly repetitive impulsive sources are well suited to coda-wave interferometry to investigate time-dependent velocity structures. Relative velocity variations (dv/v) show an annual cycle with amplitude of ~ 0.2%. Local minima are observed in the late spring, and dv/v increases through the summer monsoon rainfall, possibly reflecting patchy saturation as rainfall infiltrates near the eastern edge of the Albuquerque basin. Importantly, the cumulative results demonstrate that forensic seismology can provide insight into long-term operation of facilities such as pulsed-power laboratories, and that their recurring signals may be valuable for studies of time-dependent structure

54 ENVIRONMENTAL SCIENCES↗

Comparison of Pyranometers and Reference Cells on Fixed and One-axis Tracking Surfaces

Photovoltaic (PV) system perfomance is monitored by a wide variety of sensors. These instruments range from secondary standard pyranometers to photodiode-based pyranometers to reference cells. Although instruments are mounted in the plane of array of the modules a wide range of results have been obtained. Some of these difference have been assumed to come from systematic uncertainties associated with the irradiance sensors. This study is an attempt to quantify these differences by comparing the output of selected thermopile-based pyranometers to photodiode-based pyranometers and reference cells on a horizontal surface, a fixed-tilt surface, and a one-axis tracking surface. This analysis focuses on clear-sky results from two sites with different climatic conditions. Several important features were observed. Photodiode-based pyranometers and reference cells produce widely different results under clear skies, especially at larger angles-of-incidence even though both instruments are based on measuring the short circuit current of solar cells. The difference is caused by the scattering of light as it passes through the glazing of the reference cell or the diffuser lens of the photodioded- base pyranometer. Both instruments are shown to have similar response to the spectral distribution of the irradiance when compared to the thermopile-based pyranometer that has a response nearly independent of the wavelength of light used by PV modules.

14 SOLAR ENERGY↗

Relative Humidity Controls Ammonia Loss from Urea Applied to Loblolly Pine

In the United States of America, approximately 600,000 ha of southern pine are fertilized with urea each year, with NH3 volatilization losses ranging from <1% to >50% depending on environmental conditions. Previous work showed that timing of rainfall after urea application plays a significant role in controlling NH3 loss, but the effect of other environmental variables is not well understood. We conducted ten 29-d studies under different environmental conditions during two years to identify important variables controlling NH3 loss from urea applied to loblolly pine (Pinus taeda L.) at 200 kg N ha-1. Ammonia loss was measured with dynamic chambers that adjusted the rate of air flow through the system based on wind speed at 1 cm above the soil surface. Regression analysis indicated that a variable related to initial water content of the forest floor and a variable related to relative humidity (RH) during the study explained 85 to 94% of the observed variability in NH3 loss. Relatively high initial water content followed by consistently high RH led to large NH3 losses. In contrast, low initial water contents resulted in slow rates of NH3 loss, which increased when elevated RH led to an increase in the water content of the forest floor. These results indicate that RH can play a significant role in NH3 loss by accelerating urea dissolution and by increasing or decreasing the water content of the forest floor, which in turn can affect the rate of urea hydrolysis.

54 ENVIRONMENTAL SCIENCES↗

Remediation of Technetium in Vadose Zone Sediments Using Ammonia and Hydrogen Sulfide Gases

The feasibility of applying a combination of H 2 S and NH 3 gases for Tc-99 remediation in vadose zone sediments evaluated in laboratory experiments showed a significant mobility decrease from 75 to 95% leachable Tc-99 in untreated sediments to 15 to 48% leachable Tc-99 after gas treatment. Individual H 2 S or NH 3 gas treatment of sediments had little lasting effect. For the combined gas treatment, the H 2 S gas created reducing conditions at the pore water/mineral interface that pertechnetate was temporarily reduced/precipitated. The NH 3 gas created alkaline pore water, which induces some mineral dissolution and subsequent aluminosilicate precipitation as the pH neutralizes, which may coat Tc-99 surface phases and render them less mobile. Surface phase analysis showed Tc-99 associated with weathered basalt clasts and sulfur, possibly from the precipitation of TcS x . Treatment performance was nearly the same at different Tc-99 concentration (34 to 6500 pCi/g), water content (1 to 8%), and gas injection rate, but was sensitive to gas concentrations. Low gas concentrations (< 3%) had insufficient reductant or slower mineral dissolution. High gas concentrations (>30%) formed NH 4 SH precipitate. The 15 - 23% mobile Tc-99 remaining after gas treatment may be caused by limited time for aluminosilicates to precipitate in experiments. Nitrogen species concentrations showed no nitrate or nitrite production and a significant decrease in the sediment microbial population over three months, suggesting nitrification of added ammonia was inhibited. Overall, this study showed that combined H 2 S and NH 3 gas treatment of low water content sediments was a robust technology to significantly decrease Tc-99 mobility.

54 ENVIRONMENTAL SCIENCES↗

Surveillance of Site A and Plot M report for 2010.

The results of the environmental surveillance program conducted at Site A/Plot M in the Palos Forest Preserve area for Calendar Year 2010 are presented. Based on the results of the 1976-1978 radiological characterization of the site, a determination was made that a surveillance program be established. The characterization study determined that very low levels of hydrogen-3 (as tritiated water) had migrated from the burial ground and were present in two nearby hand-pumped picnic wells. The current surveillance program began in 1980 and consists of sample collection and analysis of surface and subsurface water. The results of the analyses are used to monitor the migration pathway of hydrogen-3 contaminated water from the burial ground (Plot M) to the hand-pumped picnic wells and monitor for the presence of radioactive materials in the environment of the area. Hydrogen-3 in the Red Gate Woods picnic wells was still detected this year, but the average and maximum concentrations were significantly less than found earlier. Hydrogen-3 continues to be detected in a number of wells, boreholes, dolomite holes, and a surface stream. Analyses since 1984 have indicated the presence of low levels of strontium-90 in water from a number of boreholes next to Plot M. The results of the surveillance program continue to indicate that the radioactivity remaining at Site A/Plot M does not endanger the health or safety of the public visiting the site, using the picnic area, or living in the vicinity.

54 ENVIRONMENTAL SCIENCES↗

The Jump-Off Velocity of an Impulsively Loaded Spherical Shell

We consider a constant temperature spherical shell of isotropic, homogeneous, linearly elastic material with density ρ and Lamé coefficients λ and μ. The inner and outer radii of the shell are r i and r o , respectively. We assume that the inside of the shell is a void. On the outside of the shell, we apply a uniform, time-varying pressure p(t). We also assume that the shell is initially at rest. We want to compute the jump-off time and velocity of the pressure wave, which are the first time after t = 0 at which the pressure wave from the outer surface reaches the inner surface. This analysis computes the jump-off velocity and time for both compressible and incompressible materials. This differs substantially from [3], where only incompressible materials are considered. We will consider the behavior of an impulsively loaded, exponentially decaying pressure wave p(t) = P 0 e -αt , where α ≥ 0. We notice that a constant pressure wave P(t) = P 0 is a special case (α = 0) of a decaying pressure wave. Both of these boundary conditions are considered in [3].

36 MATERIALS SCIENCE↗

Summary of BISON Development and Validation Activities - NEAMS FY16 Report

This summary report contains an overview of work performed under the work package en- titled “FY2016 NEAMS INL-Engineering Scale Fuel Performance (BISON)” A first chapter identifies the specific FY-16 milestones, providing a basic description of the associated work and references to related detailed documentation. Where applicable, a representative technical result is provided. A second chapter summarizes major additional accomplishments, which in- clude: 1) publication of a journal article on solution verification and validation of BISON for LWR fuel, 2) publication of a journal article on 3D Missing Pellet Surface (MPS) analysis of BWR fuel, 3) use of BISON to design a unique 3D MPS validation experiment for future in- stallation in the Halden research reactor, 4) participation in an OECD benchmark on Pellet Clad Mechanical Interaction (PCMI), 5) participation in an OECD benchmark on Reactivity Insertion Accident (RIA) analysis, 6) participation in an OECD activity on uncertainity quantification and sensitivity analysis in nuclear fuel modeling and 7) major improvements to BISON’s fission gas behavior models. A final chapter outlines FY-17 future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Seismic Wave Coherence as a Function of Propagation Azimuth at the Large-N Array, Source Physics Experiment

The Large-N array of the Source Physics Experiment (SPE) consisted, in part, of 496 vertical component geophones that recorded the seismic wave field produced by the SPE-5 buried chemical explosion. Preliminary observations of the data showed a large degree of azimuthally dependent seismic scattering, particularly for post-P wave arrivals, hindering surface wave analysis. We document and quantify the azimuthal dependence of the wave field scattering in order to guide future coherent wave field processing methods. Specifically, we form three linear arrays, with different nominal source-receiver azimuths, by extracting a subset of the Large-N stations. For each linear array, we evaluate wave field coherence as a function of frequency and inter-station distance. For P waves, we observe that there is a strong azimuthal dependence of wave coherence, with the highest degree of scattering occurring in a northwest/southeast propagation direction. This suggests that there are structural elements beneath the Large-N array that affect the direct source to receiver body wave ray path. We also observe that the scattering of the post-P energy displays a coherence that is dependent on both frequency and azimuthal direction. This energy is preferentially coherent in the southwest-to-northeast propagation direction, consistent with the strike of the steeply dipping fault (Boundary fault) adjacent to the northeast side of the Large-N array, but only at low frequencies (<10 Hz). At higher frequencies, the azimuthally dependent wave coherence diminishes, suggesting that the scattering of high frequency portion of the post-P wave field is independent of the large-scale geologic structure at this site.

58 GEOSCIENCES↗

Daikin Advanced Lithium Ion Battery Technology - High Voltage Electrolyte

An evaluation of high voltage electrolytes which contain fluorochemicals as either co-solvents or additives has been completed. The project objective was to identify a cell chemistry and electrolyte formulation which is capable of operating at 4.6 V. Stable cycle performance has been demonstrated in LiNi0.50Mn0.30Co0.20O2 (NMC532)/Artificial Graphite pouch cells to 4.6 V, with a discharge capacity retention greater than 80% after 300 cycles. A multitude of physical and chemical changes between 4.2 and 4.6V were investigated, with the goal of correlating identified degradation mechanisms with premature cell failure.

25 ENERGY STORAGE↗

Electrical-Discharge-Machining Contamination Removal from Metal Additively Manufactured Components

The use of an electrochemical dissolution process is shown to remove the recast layer contamination from the surfaces of electrical-discharge-machining cut components, as well as the interior exposed surfaces of the structure. The solution chemistry, cell potential, and exposure time are all relevant interdependent variables. Optimization of the electrode geometry should be made for each type of component. For the case of Cu-Zn recast contamination of 300-series alloy components, surface composition analysis indicates that complete electrochemical dissolution is achieved using a dilute solution of nitric acid (HNO 3 ). For example, electrochemical dissolution of the Cu-Zn recast is accomplished at 1.2 V cell potential using a 20% nitric solution and an exposure time of 4 h. The use of a nitric acid bath was specifically chosen since it’s chemically compatible and will not degrade the host alloy or the component. In sum, an electrochemically driven dissolution process can be tailored to remove of the recast contamination without affecting the integrity of the host component structure and its dimensional tolerances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surveillance of Site A and Plot M: Report for 2021

The results of the environmental surveillance program conducted at Site A/Plot M for calendar year 2021 are presented within this document. Site A/Plot M is in the Palos Area Preserves, operated by the Forest Preserve District of Cook County. The surveillance program consists of the collection and analysis of surface and groundwater samples to determine the amount of hydrogen-3 and strontium-90 present in the environment within and surrounding the site of the former research facility (Site A) and waste burial site (Plot M).

54 ENVIRONMENTAL SCIENCES↗

Surveillance of Site A and Plot M (Report for 2022)

The results of the environmental surveillance program conducted at Site A/Plot M for calendar year (CY) 2022 are presented within this document. Site A/Plot M is in the Palos Area Preserves, operated by the Forest Preserve District of Cook County. The surveillance program consists of the collection and analysis of surface and groundwater samples to determine the amount of hydrogen-3 and strontium-90 present in the environment within and surrounding the site of the former research facility (Site A) and waste burial site (Plot M).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding the field and frequency dependence of rf loss in SRF cavities

SRF cavities subjected to heat treatment below 200 °C in the presence of nitrogen showed an improvement in quality factor while maintaining an accelerating gradient above 25 MV/m. Here, we report the rf performance of several single-cell superconducting radio frequency cavities with frequency ranging from 0.75 - 3.0 GHz subjected to low temperature heat treatment in nitrogen environment. The cavities were treated at temperature 120 - 175 oC for 24 - 48 hours in low partial pressure of ultra-pure nitrogen gas. The improvement in Q? with Q-rise was observed when nitrogen gas was injected ~300 °C during the furnace treatment. The surface modification was confirmed by the change in electronic mean free path and near surface elemental analysis by SIMS. The field dependence of the rf losses is strongly correlated to the cavity frequency. The analysis of experimental data with available theoretical models as well as comparison with similar study on high temperature nitrogen doped cavities will be presented.

Ciovati, Gianluigi↗

Microwave-Assisted Production of Polycarbonate Diols using Carbon Dioxide

Carbon dioxide (CO2) is a cheap and readily available resource that can be converted to value-added chemicals including fuels, polymers, and other products. One lucrative option is polycarbonate diols, which are the precursor to polyurethanes that find wide applications in automotive and aerospace industries. The traditional process for the synthesis of polycarbonate diols involves using hazardous phosgene and alcohols in a strongly basic medium that generates significant amounts of salt. Alternately, CO2 can be reacted with alkanediols over CeO2 catalysts to produce polycarbonate diols. For the current work, a microwave-assisted atmospheric flow system was investigated for converting CO2 into polycarbonate diols and was compared against a thermal system. Various parameters such as type and ratio of solvents, and the addition of dehydrating agents for the microwave system was tested. The different CeO2 catalysts used were characterized using Brunauer–Emmett–Teller (BET) surface area analysis, Raman spectroscopy, X-ray diffraction, and temperature programmed desorption (NH3-TPD and CO2-TPD).

CO2 utilization↗

Site A and Plot M 2024 Surveillance Report and 2025 Inspection Report

The results of the environmental surveillance program conducted at Site A/Plot M for calendar year (CY) 2024 are presented within this document. Site A/Plot M is in the Palos Area Preserves managed by the Forest Preserve District of Cook County. The surveillance program consists of the collection and analysis of surface and groundwater samples to determine the amount of hydrogen-3 and strontium-90 present in the environment within and surrounding the site of the former research facility (Site A) and waste burial site (Plot M).

54 ENVIRONMENTAL SCIENCES↗

Surveillance of site A and plot M, report for 2007.

The results of the environmental surveillance program conducted at Site A/Plot M in the Palos Forest Preserve area for Calendar Year 2007 are presented. Based on the results of the 1976-1978 radiological characterization of the site, a determination was made that a surveillance program be established. The characterization study determined that very low levels of hydrogen-3 (as tritiated water) had migrated from the burial ground and were present in two nearby hand pumped picnic wells. The current surveillance program began in 1980 and consists of sample collection and analysis of surface and subsurface water. The results of the analyses are used to: (1) monitor the migration pathway of water from the burial ground (Plot M) to the hand-pumped picnic wells, (2) establish if other buried radionuclides have migrated, and (3) monitor the presence of radioactive materials in the environment of the area. Hydrogen-3 in the Red Gate Woods picnic wells was still detected this year, but the average and maximum concentrations were significantly less than found earlier. Hydrogen-3 continues to be detected in a number of wells, boreholes, dolomite holes, and a surface stream. Analyses since 1984 have indicated the presence of low levels of strontium-90 in water from a number of boreholes next to Plot M. The results of the surveillance program continue to indicate that the radioactivity remaining at Site A/Plot M does not endanger the health or safety of the public visiting the site, using the picnic area, or living in the vicinity.

54 ENVIRONMENTAL SCIENCES↗

Surveillance of Site A and Plot M, Report for 2008.

The results of the environmental surveillance program conducted at Site A/Plot M in the Palos Forest Preserve area for Calendar Year 2008 are presented. Based on the results of the 1976-1978 radiological characterization of the site, a determination was made that a surveillance program be established. The characterization study determined that very low levels of hydrogen-3 (as tritiated water) had migrated from the burial ground and were present in two nearby hand pumped picnic wells. The current surveillance program began in 1980 and consists of sample collection and analysis of surface and subsurface water. The results of the analyses are used to (1) monitor the migration pathway of hydrogen-3 contaminated water from the burial ground (Plot M) to the hand-pumped picnic wells, (2) establish if other buried radionuclides have migrated, and (3) monitor for the presence of radioactive materials in the environment of the area. Hydrogen-3 in the Red Gate Woods picnic wells was still detected this year, but the average and maximum concentrations were significantly less than found earlier. Hydrogen-3 continues to be detected in a number of wells, boreholes, dolomite holes, and a surface stream. Analyses since 1984 have indicated the presence of low levels of strontium-90 in water from a number of boreholes next to Plot M. The results of the surveillance program continue to indicate that the radioactivity remaining at Site A/Plot M does not endanger the health or safety of the public visiting the site, using the picnic area, or living in the vicinity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗