SEARCH · Engineering Papers
Results for “Spectrometer”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Regional trace-gas source attribution using a field-deployed dual frequency comb spectrometer
Not Available
Search for long-lived particles produced in p p collisions at s = 13 TeV that decay into displaced hadronic jets in the ATLAS muon spectrometer
CERN-LHC. A search for hadronic decays of neutral, weakly interacting, long-lived particles in proton-proton collisions at a centre-of-mass energy of 13 TeV is presented.
Search for long-lived neutral particles produced in p p collisions at s = 13 TeV decaying into displaced hadronic jets in the ATLAS inner detector and muon spectrometer
Explore the source record for details and available documents.
Development of Portable Gamma-Ray Spectrometers Using CZT Technology for IAEA Inspection Applications
Explore the source record for details and available documents.
Experiments with the LECO Pegasus® Gas Chromatograph/ Time-of-Flight Mass Spectrometer Phase 1: Fast GC Separations and Comparison of the GC/TOF-MS with Conventional Quadrupole GC/MS and Fast Quadrupole GC/MS
Conventional analysis by gas chromatography/quadrupole mass spectrometry (GC/MS) can be time-consuming (30 – 60 minutes) and prone to interferences. The use of fast gas chromatography coupled with time-of-flight mass spectrometry (GC/TOF-MS) offers the advantages of faster (13 min) analysis times, improved GC resolution afforded by the use of narrower (0.1– 0.18 mm i.d.) columns, and improved mass resolution and data acquisition speed provided by the TOF-MS. In addition, GC/TOF-MS offers the promise of better detection limits than quadrupole GC/MS, while still providing the full mass spectral data which offers an additional level of confidence in analyte identification.
Experiments with the LECO Pegasus® Gas Chromatograph/ Time-of-Flight Mass Spectrometer Phase 2: 2D Fast GC Separations
Conventional analysis by gas chromatography/ quadrupole mass spectrometry (GC/MS) can be time-consuming (30 – 60 minutes) and prone to interferences. The use of fast gas chromatography coupled with time-of-flight mass spectrometry (GC/TOF-MS) offers the advantages of faster (~10 min) analysis times, improved GC resolution afforded by the use of narrower (0.1– 0.18 mm id) columns, and improved mass resolution and scan speed provided by the TOF-MS. In addition, GC/TOF-MS offers the promise of better instrument detection limits than quadrupole GC/MS, while still providing full mass spectral data. If the GC/TOF-MS can be operated to perform two-dimensional (2D) separations, the ability to resolve peaks of interest from interfering compounds is improved. In 2D chromatography, a second GC column with a different chemical phase than that of the first GC column is used to provide additional separation of analytes as they elute from the first column. Because the chemistry of the second GC column is different from the first, compounds that co-elute from the first column may be easily resolved after a separation on the second GC column (i.e., the peak capacity of the system is increased and the specificity of analyte detection is improved).
Nonlinear Signal Processing for Removing Microphonic Noise from Nuclear Spectrometer Measurements: Sparse Linear Modeling via L1 Norm Regularization [Slides]
The focus of this initial work is to apply recent breakthroughs in sparse linear modeling and nonlinear signal processing to the problem of removing microphonic noise from nuclear spectrum measurements. The resolution of nuclear spectrum measurements is commonly degraded by microphonic noise caused by the vibration of supporting equipment (i.e. cryocoolers) as well as motion of the detector itself in mobile applications. Current signal processing techniques cannot remove microphonic noise without modifying the desired characteristics of the spikes induced by nuclear detection events. The LANL Engineering Institute has been working with NEN‐1 to remedy this problem. Initial work focused on developing active control systems to cancel the vibrations experienced by nuclear detectors. As work on progressed along these lines the team realized that a more robust, lower‐energy, lower‐cost solution to the microphonic noise problem could be realized using recent breakthroughs in nonlinear signal processing. Over the course of the last decade significant advances have been made in the field of sparse linear modeling using L1 norm minimization to find linear representations of sparse signals. The problem of removing microphonic noise from nuclear detection measurements appears to be well suited to the L1 minimization approach because these measurements tend to be inherently sparse in two different domains. The nuclear detections are sparse in a spike domain, and the microphonic noise is sparse in the Fourier basis. L1 minimization allows us to decompose the measurements into these two domains. The result is that we can potentially separate the spikes from the microphonic noise. Initial investigations into this technique look very promising. In this work microphonic noise is induced in an HE‐3 detector by a wrench impact. A pulser is used to generate uniform, synthetic, nuclear events and is fed into the detector front end electronics. Nearly all the microphonic noise is separated from the spike measurements. The histograms in Figure 2 illustrate that spectrum widening caused by noise is significantly reduced. The goal of future work to further develop this technique to account for variations in spike characteristics, as well as to use adaptive signal processing and modern Graphical Processing Unit (GPU) technology to speed up the signal decompositions.
Lead Slowing Down Spectrometer Research Plans
The MPACT-funded Lead Slowing Down Spectrometry (LSDS) project has been evaluating the feasibility of using LSDS techniques to assay fissile isotopes in used nuclear fuel assemblies. The approach has the potential to provide considerable improvement in the assay of fissile isotopic masses in fuel assemblies compared to other non-destructive techniques in a direct and independent manner. The LSDS collaborations suggests that the next step to in empirically testing the feasibility is to conduct measurements on fresh fuel assemblies to understand investigate self-attenuation and fresh mixed-oxide (MOX) fuel rodlets so we may better understand extraction of masses for 235 U and 239 Pu. While progressing toward these goals, the collaboration also strongly suggests the continued development of enabling technology such as detector development and algorithm development, which could provide significant performance benefits.
Development of Remote-controlled Gamma-ray Spectrometer [Slides]
Abstract Not Provided
Lead Slowing Down Spectrometer FY2013 Annual Report
Executive Summary The Lead Slowing Down Spectrometry (LSDS) project, funded by the Materials Protection And Control Technology campaign, has been evaluating the feasibility of using LSDS techniques to assay fissile isotopes in used nuclear fuel assemblies. The approach has the potential to provide considerable improvement in the assay of fissile isotopic masses in fuel assemblies compared to other non-destructive techniques in a direct and independent manner.
Final Technical Report for Integrated Analysis of Multiple Worldwide Aerosol Mass Spectrometer Datasets for Improved Understanding of Aerosol Sources
Explore the source record for details and available documents.
Comprehensive Cloud-based Nuclide Identification for Handheld Gamma-Ray Spectrometers
Abstract not provided
Eddy-currrents and the Force Analysis for the Thermal Shields of the MICE Spectrometer Solenoids
Explore the source record for details and available documents.
Determining x-ray spectra of radiographic sources with a Compton spectrometer [Slides]
Calibration experiment was successfully conducted. Experimental procedure was improved (collimation, alignment, etc.). First measurements of pulsed sources have been completed!
Market Research Survey of Commercial Off-the-Shelf Mass Spectrometers for In-Field Analysis. FY 15 Update
This report is an update of the 2013 Market Research Survey1-3 of field-deployable commercial off-the-shelf (COTS) mass spectrometry instruments for safeguards application.
High-Throughput Method for Strontium Isotope Analysis by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometer
This technical report presents the details of the Sr column configuration and the high-throughput Sr separation protocol. Data showing the performance of the method as well as the best practices for optimizing Sr isotope analysis by MC-ICP-MS is presented. Lastly, this report offers tools for data handling and data reduction of Sr isotope results from the Thermo Scientific Neptune software to assist in data quality assurance, which help avoid issues of data glut associated with high sample throughput rapid analysis.