Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Experiments with the LECO Pegasus® Gas Chromatograph/ Time-of-Flight Mass Spectrometer Phase 1: Fast GC Separations and Comparison of the GC/TOF-MS with Conventional Quadrupole GC/MS and Fast Quadrupole GC/MS

Conventional analysis by gas chromatography/quadrupole mass spectrometry (GC/MS) can be time-consuming (30 – 60 minutes) and prone to interferences. The use of fast gas chromatography coupled with time-of-flight mass spectrometry (GC/TOF-MS) offers the advantages of faster (13 min) analysis times, improved GC resolution afforded by the use of narrower (0.1– 0.18 mm i.d.) columns, and improved mass resolution and data acquisition speed provided by the TOF-MS. In addition, GC/TOF-MS offers the promise of better detection limits than quadrupole GC/MS, while still providing the full mass spectral data which offers an additional level of confidence in analyte identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experiments with the LECO Pegasus® Gas Chromatograph/ Time-of-Flight Mass Spectrometer Phase 2: 2D Fast GC Separations

Conventional analysis by gas chromatography/ quadrupole mass spectrometry (GC/MS) can be time-consuming (30 – 60 minutes) and prone to interferences. The use of fast gas chromatography coupled with time-of-flight mass spectrometry (GC/TOF-MS) offers the advantages of faster (~10 min) analysis times, improved GC resolution afforded by the use of narrower (0.1– 0.18 mm id) columns, and improved mass resolution and scan speed provided by the TOF-MS. In addition, GC/TOF-MS offers the promise of better instrument detection limits than quadrupole GC/MS, while still providing full mass spectral data. If the GC/TOF-MS can be operated to perform two-dimensional (2D) separations, the ability to resolve peaks of interest from interfering compounds is improved. In 2D chromatography, a second GC column with a different chemical phase than that of the first GC column is used to provide additional separation of analytes as they elute from the first column. Because the chemistry of the second GC column is different from the first, compounds that co-elute from the first column may be easily resolved after a separation on the second GC column (i.e., the peak capacity of the system is increased and the specificity of analyte detection is improved).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlinear Signal Processing for Removing Microphonic Noise from Nuclear Spectrometer Measurements: Sparse Linear Modeling via L1 Norm Regularization [Slides]

The focus of this initial work is to apply recent breakthroughs in sparse linear modeling and nonlinear signal processing to the problem of removing microphonic noise from nuclear spectrum measurements. The resolution of nuclear spectrum measurements is commonly degraded by microphonic noise caused by the vibration of supporting equipment (i.e. cryocoolers) as well as motion of the detector itself in mobile applications. Current signal processing techniques cannot remove microphonic noise without modifying the desired characteristics of the spikes induced by nuclear detection events. The LANL Engineering Institute has been working with NEN‐1 to remedy this problem. Initial work focused on developing active control systems to cancel the vibrations experienced by nuclear detectors. As work on progressed along these lines the team realized that a more robust, lower‐energy, lower‐cost solution to the microphonic noise problem could be realized using recent breakthroughs in nonlinear signal processing. Over the course of the last decade significant advances have been made in the field of sparse linear modeling using L1 norm minimization to find linear representations of sparse signals. The problem of removing microphonic noise from nuclear detection measurements appears to be well suited to the L1 minimization approach because these measurements tend to be inherently sparse in two different domains. The nuclear detections are sparse in a spike domain, and the microphonic noise is sparse in the Fourier basis. L1 minimization allows us to decompose the measurements into these two domains. The result is that we can potentially separate the spikes from the microphonic noise. Initial investigations into this technique look very promising. In this work microphonic noise is induced in an HE‐3 detector by a wrench impact. A pulser is used to generate uniform, synthetic, nuclear events and is fed into the detector front end electronics. Nearly all the microphonic noise is separated from the spike measurements. The histograms in Figure 2 illustrate that spectrum widening caused by noise is significantly reduced. The goal of future work to further develop this technique to account for variations in spike characteristics, as well as to use adaptive signal processing and modern Graphical Processing Unit (GPU) technology to speed up the signal decompositions.

42 ENGINEERING↗

Lead Slowing Down Spectrometer Research Plans

The MPACT-funded Lead Slowing Down Spectrometry (LSDS) project has been evaluating the feasibility of using LSDS techniques to assay fissile isotopes in used nuclear fuel assemblies. The approach has the potential to provide considerable improvement in the assay of fissile isotopic masses in fuel assemblies compared to other non-destructive techniques in a direct and independent manner. The LSDS collaborations suggests that the next step to in empirically testing the feasibility is to conduct measurements on fresh fuel assemblies to understand investigate self-attenuation and fresh mixed-oxide (MOX) fuel rodlets so we may better understand extraction of masses for 235 U and 239 Pu. While progressing toward these goals, the collaboration also strongly suggests the continued development of enabling technology such as detector development and algorithm development, which could provide significant performance benefits.

Lead slowing down spectrometry↗

Lead Slowing Down Spectrometer FY2013 Annual Report

Executive Summary The Lead Slowing Down Spectrometry (LSDS) project, funded by the Materials Protection And Control Technology campaign, has been evaluating the feasibility of using LSDS techniques to assay fissile isotopes in used nuclear fuel assemblies. The approach has the potential to provide considerable improvement in the assay of fissile isotopic masses in fuel assemblies compared to other non-destructive techniques in a direct and independent manner.

Warren, Glen A.↗

High-Throughput Method for Strontium Isotope Analysis by Multi-Collector-Inductively Coupled Plasma-Mass Spectrometer

This technical report presents the details of the Sr column configuration and the high-throughput Sr separation protocol. Data showing the performance of the method as well as the best practices for optimizing Sr isotope analysis by MC-ICP-MS is presented. Lastly, this report offers tools for data handling and data reduction of Sr isotope results from the Thermo Scientific Neptune software to assist in data quality assurance, which help avoid issues of data glut associated with high sample throughput rapid analysis.

47 OTHER INSTRUMENTATION↗