Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Single Crystal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Hydrogen effects in 001-line oriented nickel-base superalloy single crystals

The entry and subsequent interaction of hydrogen on the mechanical properties of the single crystal nickel-base superalloy CMSX-2 has been studied. Significant amounts of hydrogen were introduced by high temperature hydrogen charging in molten salts which led to an increased lattice parameter and microhardness and to a degradation in tensile elongation to failure whose extent scales with the depth of the hydrogenated zone. In this region a fracture mode change from a 111 to a 100 plane type also occurred. The values of the binding energy of hydrogen to solidification voids and the effective hydrogen pressure in the voids were estimated.

Baker, C. L.↗

The high temperature deformation in cyclic loading of a single crystal nickel-base superalloy

The high temperature cyclic stress softening response of the single crystal nickel-base superalloy PWA 1480 was investigated. Specimens oriented near the 001- and 111-lines were tested at 1050 C in low-cycle fatigue and then microstructurally evaluated. The 001- and 111-line specimens had dissimilar flow behavior in monotonic tensile tests, but comparable softening in low-cycle fatigue. This softening was accompanied by rapid generation of dislocation networks at the gamma-gamma-prime interfaces and by a slower time-dependent coarsening of gamma-prime precipitates. Due to the rapid formation of a dislocation substructure at the gamma-gamma-prime interfaces, the cyclic stress softening could be modeled with an existing theory which related cyclic stress to the evolving microstructure and dislocation structure.

Gabb, T. P.↗

Creep substructure formation in sodium chloride single crystals in the power law and exponential creep regimes

Creep tests conducted on NaCl single crystals in the temperature range from 373 to 1023 K show that true steady state creep is obtained only above 873 K when the ratio of the applied stress to the shear modulus is less than or equal to 0.0001. Under other stress and temperature conditions, corresponding to both power law and exponential creep, the creep rate decreases monotonically with increasing strain. The transition from power law to exponential creep is shown to be associated with increases in the dislocation density, the cell boundary width, and the aspect ratio of the subgrains along the primary slip planes. The relation between dislocation structure and creep behavior is also assessed.

Raj, S. V.↗

The effect of hydrogen on the low cycle fatigue behavior of a single crystal superalloy

The present study compares the room temperature fatigue properties of PWA 1480 single crystals containing either normal or elevated hydrogen levels, giving attention to the effects of various levels of HIPing process-controlled porosity on hydrogen-trapping and fatigue life. Hydrogen charging is found to degrade the fatigue lives of alloy samples by an order of magnitude; the magnitude of this degradation is comparable at both high and low porosity. HIPing accomplished a small beneficial effect on the fatigue life of both the hydrogen-charged and uncharged PWA 1480 samples. Fatigue cracks are noted to have consistently initiated at large, near-surface pores. By reducing the size and frquency of the larger pores, HIPing apparently retarded fatigue-crack initiation.

Gayda, J.↗

Burner Rig Hot Corrosion of a Single Crystal Ni-48Al-Ti-Hf-Ga Alloy

The hot corrosion resistance of a single crystal Ni-48Al-1Ti-0.5Hf-0.2Ga alloy was examined in a Mach 0.3 burner rig at 900 C for 300 hours. The combustion chamber was doped with 2 ppmw synthetic sea salt. The hot corrosion attack produced a random mound morphology on the surface. Microstructurally, the hot corrosion attack appeared to initiate with oxide-filled pits which were often broad and shallow. At an intermediate stage, the pits increased in size to incorporate unoxidized Ni islands in the corrosion product. The rampant attack stage, which was observed only at sharp sample corners, was characterized by rapid inward growth of alumina in finger-like protrusions incorporating significant amounts of Al-depleted Ni islands. Aluminum consumption in the oxide fingers resulted in the growth of a gamma' layer ahead of the advancing oxide fingers.

Nesbitt, James A.↗

Single shot ultrafast dynamic ellipsometry (UDE) of laser-driven shocks in single crystal explosives

We report on the first experiments to measure states in shocked energetic single crystals with dynamic ellipsometry. We demonstrate that these ellipsometric techniques can produce reasonable Hugoniot values using small amounts of crystalline RDX and PETN. Pressures, particle velocities and shock velocities obtained using shocked ellipsometry are comparable to those found using gas-gun flyer plates and molecular dynamics calculations. The adaptation of the technique from uniform thin films of polymers to thick non-perfect crystalline materials was a significant achievement. Correct sample preparation proved to be a crucial component. Through trial and error, we were able to resolve polishing issues, sample quality problems, birefringence effects and mounting difficulties that were not encountered using thin polymer films.

36 MATERIALS SCIENCE↗

Dependence of the X-Ray Dosimetric Parameters of AgGaS{sub 2x}Se{sub 2–2x} Single Crystals on Their Composition

It is demonstrated that AgGaS{sub 2x}Se{sub 2–2x} single crystals grown by the chemical transport method are characterized by high X-ray conductivity and X-ray sensitivity coefficients at room temperature. The X-ray dosimetric parameters of crystals are compared. For example, the X-ray conductivity coefficient of AgGaS{sub 2} samples varies within the range of 0.22–3.20 min/R at effective radiation hardness V{sub a} = 25–50 keV and dose rate E = 0.75–78.05 R/min. Single-crystalline AgGaSe{sub 2} samples have higher X-ray dosimetric coefficients than AgGaS{sub 2}-based samples. The X-ray conductivity coefficient of AgGaSe{sub 2} varies within the range of 1.2–8.5 min/R at effective radiation hardness V{sub a} = 25–50 keV and dose rate E = 0.75–31.3 R/min. The dose dependences of steady-state X-ray current in AgGaS{sub 2x}Se{sub 2–2x} are determined.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plastic deformation of single crystals of the equiatomic Cr-Mn-Fe-Co-Ni high-entropy alloy in tension and compression from 10 K to 1273 K

In this report the plastic deformation behavior of single crystals of the quinary, equiatomic Cr-Mn-Fe-Co-Ni high-entropy alloy (HEA) with the face-centered cubic structure has been investigated in tension and compression as a function of crystal orientation and temperature from 10 K to 1373 K. The critical resolved shear stress (CRSS) for {111}<110> slip at room temperature is 42-45 MPa. It does not depend much on crystal orientation (i.e., the Schmid law holds true) and the sense (tension vs. compression) of the applied load. The CRSS for {111}<110> slip increases with the decrease in temperature, without showing any significant inertia effects at cryogenic temperatures below 77 K. Extrapolation from the measured yield stresses down to 10 K yields a CRSS value at 0 K of 168 MPa. At cryogenic temperatures, the measured strain-rate sensitivity of flow stress is consistent with a very small activation volume. The concept of stress equivalence holds true both for the temperature dependence of CRSS and the stress dependence of activation volume, indicating that solid-solution hardening is the major strengthening mechanism. Deformation twinning occurs at 77 K but not at room temperature, resulting in higher tensile elongation to failure at 77 K than at room temperature. Deformation twinning at 77 K occurs at a shear stress of 378 MPa on conjugate ($\bar1\bar11$) planes in the form of Lüders deformation after large plastic strain (about 85%) achieved by the stage I (easy glide) and stage II (linear work-hardening) deformation.

36 MATERIALS SCIENCE↗

Single-Crystal Permanent Magnets: Extraordinary Magnetic Behavior in the Ta-,Cu-, and Fe-Substituted CeCo 5 Systems

To reduce material and processing costs of commercial permanent magnets and to attempt to fill the empty niche of energy products, 10–20 MGOe, between low-flux (ferrites, alnico) and high-flux (Nd 2 Fe 14 B- and SmCo 5 -type) magnets, we report the synthesis, structure, magnetic properties, and modeling of Ta-, Cu-, and Fe-substituted CeCo 5 . Using a self-flux technique, we grow single crystals of Ce 15.1 Ta 1.0 Co 74.4 Cu 9.5 , Ce 16.3 Ta 0.6 Co 68.9 Cu 14.2 , Ce 15.7 Ta 0.6 Co 67.8 Cu 15.9 , Ce 16.3 Ta 0.3 Co 61.7 Cu 21.7 , and Ce 14.3 Ta 1.0 Co 62.0 Fe 12.3 Cu 10.4 . X-ray-diffraction analysis shows that these materials retain a CaCu 5 substructure and incorporate small amounts of Ta in the form of “dumbbells,” filling the 2e crystallographic sites within the one-dimensional hexagonal channel with the 1a Ce site, whereas Co, Cu, and Fe are statistically distributed among the 2c and 3g crystallographic sites. Scanning-electron-microscopy, energy-dispersive-x-ray-spectroscopy, and scanning-transmission-electron-microscopy examinations provide strong evidence of the single-phase nature of the as-grown crystals, even though they readily exhibit significant magnetic coercivities of approximately 1.6 kOe to approximately 1.8 kOe caused by Co-enriched, nanosized structural defects and faults that can serve as pinning sites. Heat treatments at 1040°C for 10 h and hardening at 400°C for 4 h lead to the formation of a so-called composite crystal with a bimodal microstructure that consists of a Ta-poor matrix and Ta-rich laminal precipitates. Formation of the composite crystal during the heat treatment creates a three-dimensional array of extended defects within a primarily single-grain single crystal, which greatly improves its magnetic characteristics. Possible causes for the formation of the composite crystal may be associated with Ta atoms leaving matrix interstices at lower temperatures and/or matrix degradation induced by decreased miscibility at lower temperatures. Furthermore Fe strongly increases both the Curie temperature and magnetization of the system resulting, in ( BH ) max ≈ 13 MGOe at room temperature.

36 MATERIALS SCIENCE↗

Radiation of X-Rays Using Uniaxially Polarized LiNbO{sub 3} Single Crystal

X-rays are radiated due to the bremsstrahlung caused by the collision of electrons with a metal target placed opposite the negative electric surface of a crystal by changing the temperature of a LiNbO{sub 3} single crystal uniaxially polarized in the c-axis direction. It is suggested that both electric field intensity and electron density determine the intensity of X-ray radiation. Electrons are supplied by the ionization of residual gas in space, field emission from a case inside which a crystal is located, considered to be due to the high electric-field intensity formed by the surface charges on the crystal, and an external electron source, such as a thermionic source. In a high vacuum, it was found that the electrons supplied by electric-field emission mainly contribute to the radiation of X-rays. It was found that the integrated intensity of X-rays can be maximized by supplying electrons both external and by electric-field emission. Furthermore, the integrated intensity of the X-rays is stable for many repeated temperature changes.

36 MATERIALS SCIENCE↗

Single-crystal X-ray diffraction of fluorapatite to 61 GPa

Apatite is a mineral of widespread importance in Earth and planetary science. Here we examine the behavior of a natural fluorapatite (FAp) crystal from Durango (Mexico) under compression to 61 GPa. Single-crystal X-ray diffraction experiments were carried out in a diamond-anvil cell using a synchrotron source. The apatite structure persists up to 32.4 GPa. Birch-Murnaghan equation of state parameters were fit to the pressure-volume data for fluorapatite for two cases: fixing V 0 at its measured ambient value resulted in a bulk modulus, K 0T , of 97.0(8) GPa and a pressure derivative of the bulk modulus, K' 0T , of 3.3(1), while fixing V 0 and K 0T at its ambient value 90.5 GPa (derived from ultrasonically measured elastic constants) resulted in a K' 0T value of 4.1(1). At 35.6 GPa, fluorapatite transforms to a triclinic phase (P$\bar{1}$, Z = 4), designated here as fluorapatite II (FAp-II). This phase persists up to at least 61 GPa. The major structural differences between FAp and FAp-II involve the buckling of the Ca polyhedra along the c-axis and changes in the number and coordination of the Ca sites. Furthermore, our study extends the pressure range over which fluorapatite has been examined by more than a factor of three, providing new insights into its structural response to high-pressure conditions.

58 GEOSCIENCES↗

Directional Point-Contact Josephson Junctions on Ba0.4K0.6(FeAs)2 Single Crystals

We investigated the Josephson effect between the conventional superconductor Pb0.7In0.3 and Ba0.4K0.6 (FeAs)2 single crystals by performing directional point-contact experiments. The junctions were irradiated with microwaves and the behavior of the Shapiro steps as a function of the square root of the microwave power was studied by means of the RSJ model extended to the nonautonomous case with an rf current-source term. The analysis reveals that, for current injection along the ab plane, the current-phase relation deviates from being simply described by the standard sin(Φ) (as we indeed observed along the c axis) and a dominant sin(2Φ) component is observed. The results are compared with a theory of the dc Josephson effect, formulated by using a method based on the calculation of temperature Green’s function in the junction within the tight-binding model (Burmistrova et al., Phys. Rev. B 91, 214501, 2015). The comparison shows that the experimental results here presented strongly favor an s ±-wave symmetry of the order parameter in this compound.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Ar Post-irradiations on Magnetic Properties of Cu-Implanted ZnO Single Crystals

Ar{sup +} post-irradiation effects on magnetic behavior of Cu{sup +}-implanted ZnO single crystals were studied. It was found that Cu{sup +}-implanted and Ar{sup +}-irradiated samples, even the primary sample, showed a magnetic moment (M{sub M}), but the saturation magnetization (M{sub S}) of Ar{sup +} post-irradiated on Cu{sup +} as-implanted one drastically decreased. Based on the first-principle method, it was drawn to the incomplete filling electronic configuration of the substituted Cu ion whose 3d orbital hybridized with O-2p contributing to the magnetism. The M{sub M} induced by the substituted Cu{sup +} ion was much less than that induced by the substituted Cu{sup 2+} and Cu{sup 3+} ion, so the ratio of Cu{sup 2+,3+}/Cu{sup +} decreased after Ar{sup +} post-irradiation, leading to the decrease of M{sub S}. The excessive concentration of O vacancy induced by post-irradiation also weakened the M{sub M} by their compensating electrons, and decreased the effective magnetic exchange coupling interaction. Cu-related clusters dissolution was also a critical reason for the reduction of M{sub S}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ni-Rich Li[Ni x MnyCo 1– x – y ]O 2 Single Crystals as Superior Fast Charge Cathodes for Lithium-Ion Batteries

The utilization of single-crystal (SC) Li[Ni x MnyCo 1-x-y ]O 2 (NMC) cathodes has facilitated unparalleled performance in commercial high-energy lithium-ion batteries (LIBs). In the current study, we evaluate the application of SC cathodes in fast charge (FC)-LIBs where particle cracking is a predominant failure mechanism. Ni-rich SC-NMC samples with various compositions, sizes, and shapes are synthesized and investigated for their influence on FC performance. We reveal the necessity of utilizing smaller SCs (<1 μm) as larger sizes (>2 μm) experience significant particle-level lithium concentration gradients under FC conditions. To improve lithium transport and minimize side reactivities, we strategically expose the (104) crystal facets on the surface. Exceptional performance was observed on an optimized SC-LiNi 0.80 Mn 0.05 Co 0.15 O 2 , delivering a discharge capacity of 165 mAh/g even after 150 cycles at 6C charge. Our study not only demonstrates the promise of SC-NMC but also provides the key insights for the design and optimization of advanced cathodes for FC-LIBs.

25 ENERGY STORAGE↗

Large sensitive-area NbN nanowire superconducting single-photon detectors fabricated on single-crystal MgO substrates

We report on the performance of large area NbN nanowire superconducting single-photon detectors (SSPDs). 20x20 {mu}m{sup 2} area SSPDs with 80 and 100 nm linewidths and 50% fill factor were fabricated in 4-nm-thick NbN films grown on single-crystal MgO substrates. The high quality of the devices was verified by electrical and optical testing and compares favorably to measurements of 10x10 {mu}m{sup 2} area SSPDs. Measurements of kinetic inductance versus bias current indicate that the constriction density is low. The fiber-coupled detection efficiency of the devices was 0.4%-3.5% at 100 Hz dark count rate.

36 MATERIALS SCIENCE↗

Photo-transport properties of Pb{sub 2}CrO{sub 5} single crystals

We report photo-thermoelectric transport phenomena in Pb{sub 2}CrO{sub 5} single crystals. Without illumination, this material exhibits an insulating behavior characterized by an activation-type temperature variation of the electrical conductivity. The Seebeck coefficient contrastingly shows a crossover from high-temperature insulating to low-temperature metallic behavior, which is attributed to degenerate carriers in a donor level. We have found that under illumination, both the conductivity and the Seebeck coefficient increase in magnitude with increasing photon flux density in the degenerate-conduction regime. This result is difficult to understand within a simple photo-doping effect, which usually leads to a decrease in the Seebeck coefficient under illumination. The observed phenomenon is discussed in terms of a two-carrier contribution to the transport properties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large magnetoresistance and Fermi surface study of Sb 2 Se 2 Te single crystal

Here, we have studied the magnetotransport properties of a Sb 2 Se 2 Te single crystal. Magnetoresistance (MR) is maximum when the magnetic field is perpendicular to the sample surface and reaches a value of 1100% at B = 31 T with no sign of saturation. MR shows Shubnikov de Haas (SdH) oscillations above B = 15 T. The frequency spectrum of SdH oscillations consists of three distinct peaks at α = 32 T, β = 80 T, and γ = 117 T indicating the presence of three Fermi surface pockets. Among these frequencies, β is the prominent peak in the frequency spectrum of SdH oscillations measured at different tilt angles of the sample with respect to the magnetic field. From the angle dependence β and Berry phase calculations, we have confirmed the trivial topology of the β-pocket. The cyclotron masses of charge carriers, obtained by using the Lifshitz–Kosevich formula, are found to be m$*\atop{β}$= 0.16m o and m$*\atop{γ}$= 0.63m o for the β and γ bands, respectively. The Large MR of Sb 2 Se 2 Te is suitable for utilization in electronic instruments such as computer hard discs, high field magnetic sensors, and memory devices.

36 MATERIALS SCIENCE↗

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory’s Second Target Station. Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. In addition, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need for truly curved guides. Further, to enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer m-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and 3 He spin filters over the default polarized wavelength band of 1.2–5.5 Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average P 2 T of ~35%.

47 OTHER INSTRUMENTATION↗