Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Distributed Brillouin fiber laser sensor

Brillouin fiber sensors can provide distributed strain and temperature measurements over long distances in standard off-the-shelf fiber by measuring the Brillouin frequency shift as a function of position along a fiber. The primary drawback of these systems is their limited sensitivity, which results from the challenge in identifying the Brillouin frequency shift to within a small fraction of the Brillouin linewidth. In this work, we introduce a technique that overcomes this fundamental limitation by establishing a series of lasing modes that experience Brillouin amplification at discrete spatial locations in the test fiber. The linewidth narrowing and high intensity associated with the lasing transition enable precise measurements of this lasing frequency. As an initial demonstration, we present a sensor that simultaneously excites 40 lasing modes in a 400 m fiber, providing a measurement of the strain at 40 discrete locations with a spatial resolution of 4 m. Each sensor exhibits a minimum detectable strain as low as 4 nε/Hz 1/2 with a dynamic range of >5 mε and a bandwidth of ~10 kHz. As the first demonstration that Brillouin lasing can be used for distributed fiber sensing, this work establishes an approach that could enable ultra-high strain sensitivity using off-the-shelf fiber.

47 OTHER INSTRUMENTATION↗

WHONDRS River Corridor Sediment and Water Geochemistry and In Situ Sensor Data from 7 Perennial and 7 Intermittent Streams across San Antonio, Texas (v3)

This dataset supports a broader study examining the effects of intermittency on sediment respiration. The dataset provides sediment and surface water geochemistry and in situ sensor data from 7 perennial and 7 intermittent streams in San Antonio, Texas. Each stream/site was visited both in summer during base flow (July-September 2023) and winter during peak flow (January-February 2024). Related data were collected and will be published separately in collaboration with A. Veach. The data package was originally published in April 2025. It was updated in June 2025 (v2; modified and new files) and September 2025 (v3; modified files). See the change history section in the readme for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. This dataset is comprised of two folders of field photos and videos, one folder of raw Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) data and one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) readme; (5) international generic sample number (IGSN) mapping file; (6) field protocol; (7) a subfolder with sample data; and (8) a subfolder with sensor data. The sample data subfolder contains (1) surface water and sediment dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (2) surface water and sediment total nitrogen data and averages; (3) sediment grain size data; (4) sediment iron (II) data and averages; (5) wet sediment mass, dry sediment mass, water mass, and wet sediment volume in incubation and sediment ICR vials; (7) sediment incubation respiration rate data and averages; (8) normalized respiration rate data and averages; (9) methods codes; (10) sediment percent carbon and nitrogen; (11) sediment X-ray diffraction (XRD) data; (12) gravimetric moisture and averages; (13) a subfolder with sediment incubation respiration data, scripts, and plots; (14) surface water and sediment FTICR methods; and (15) a subfolder of 9.4 Tesla (9.4T) FTICR-MS data. This folder contains five subfolders, one containing the sediment .xml data files, one containing the water .xml files, one containing the sediment CoreMS output files, one containing the water CoreMS output files, and the other containing instructions and scripts for processing the files in CoreMS (https://github.com/EMSL-Computing/CoreMS). The sensor data subfolder contains (1) a subfolder with miniDOT dissolved oxygen and temperature data and plots; (2) miniDOT dissolved oxygen and temperature summary data; and (3) miniDOT installation methods. All files are .csv, .pdf, .R, .xml, .d, .html, .Rmd, .py, .cal, .json, .jpg, .jpeg, .png, .mov, or .mp4. CORRECTION: The data processing methods for FTICR described in “v3_WHONDRS_AV1_Methods_Codes.csv” mistakenly indicate that users should process the data in Formultitude. The corrected description should read: “Both unprocessed and processed data are provided to allow users flexibility in data processing. Instructions and scripts for processing the data using CoreMS are included.” CORRECTION: Carbon and nitrogen content are reported as percentages. The current column headers "01395_C_percent_per_mg" and "01397_N_percent_per_mg" are incorrect. These should read "01395_C_percent" and "01397_N_percent" and will be corrected in the next version of this data package.

54 ENVIRONMENTAL SCIENCES↗

COMPASS-FME Synoptic Sites Level 1 Sensor Data v2-1

This is the version 2-1 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our synoptic field sites. COMPASS-FME is studying sites in two distinct regions, the Chesapeake Bay and the Western Lake Erie Basin. We established the network at seven "synoptic" (observational) sites along the Chesapeake Bay and Lake Erie coastlines, collectively generating over three million observations per month, to track and comprehend environmental changes where land and water intersect. Additionally, the two regions provide an interesting contrast of saltwater and freshwater coasts that allow us to differentiate the impacts of inundation and coastal water chemistries in two nationally important coastal systems. L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds, out-of-service, and outlier flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project** This dataset includes: - An overall dataset README file that describes the current version, gives citation and contact information, etc. - Site- and year-specific folders, each holding up to 12 CSV (comma separated value) data files for each site and plot in that year. - Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, as well as a general description of the site. - Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes. Please see v2-0 Synoptic L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning. This dataset was updated 2026-03-12: (i) data now go through 2025-12-31 (previous end was 2025-06-30) and (ii) dataset and file names updated to “…v2-1” (previously was “v2-0”).

54 ENVIRONMENTAL SCIENCES↗

COMPASS-FME Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) Experiment Level 1 Sensor Data v2-1

This is the version 2-1 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental site. This manipulative, ecosystem-scale TEMPEST experiment addresses the potential for freshwater and estuarine-water disturbance events to alter tree function, species composition, and ecosystem processes in a deciduous coastal forest in MD, USA. The experiment uses a large-unit (2000 m2), un-replicated experimental design, with three 50 m × 40 m plots serving as control, freshwater, and estuarine-water treatments. L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds, out-of-service, and outlier flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project** This dataset includes: - An overall dataset README file that describes the current version, gives citation and contact information, etc. - Site- and year-specific folders, each holding variable-specific CSV (comma separated value) data files for each site and plot in that year. - Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, detailed flood times, as well as a general description of the site. - Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes. Please see v2-1 TEMPEST L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning. The TEMPEST flood events occurred on the following dates. They lasted for ~10 hours each day and delivered ~80,000 gallons to each plot; many data streams are available at 1 or 5 minute frequency during these periods. * Tests: Aug 25 (fresh plot) and Sep 9 (salt plot), 2021 * TEMPEST 1: June 22, 2022 * TEMPEST 2: June 6-7, 2023 * TEMPEST 3: June 11-13, 2024 This dataset was updated 2026-03-12: (i) data now go through 2025-12-31 (previous end was 2025-06-30) and (ii) dataset and file names updated to “…v2-1” (previously was “v2-0”).

54 ENVIRONMENTAL SCIENCES↗

Thermal dissipation sensors enter a new age: Navigating frontiers in transpiration and hydrologic function

Thermal dissipation (TD) sensors have been used extensively for a wide array of sap flow applications, and yet recently several limitations of this approach have been identified, including a tendency to underestimate absolute flows, especially in small stems with very high flows. However, when used properly, the TD method remains the most cost effective and reliable approach for determining relative flows in comparison studies. Major advantages of this method include the ability to replicate maximally within trees, across trees of different sizes, and across multiple species to capture the full range of natural variation in the study system. From early studies, such variation has been deemed a major challenge for representing stand-level dynamics. In a series of recent comparison studies, we determined mean sap flux density dynamics within and among groups of trees. These studies were conducted within temperate coniferous forest (n=46), temperate oak savanna (n=36), temperate pine forest (n=49), temperate bottomland hardwood forest (n=23), tropical premontane rainforest (n=43), semiarid subtropical shrubland (n=25), and tropical dry forest (n=15), with a total of 237 sensors. Two study sites were also equipped with eddy covariance systems for determination of stand-level evapotranspiration. Sites subject to high background thermal gradients used the transient thermal dissipation method. Comparisons varied between studies but tended to focus on relative flow differences between species, between wetter and drier microsites, between understory and overstory components, or between wetter and drier periods of the growing season. Except for the shrubland sites, study trees tended to be at least 15-cm diameter and frequently exceeded 50-cm diameter. Results of this cross-site comparison highlight the inherent variation in natural stands and the importance of using large sample sizes. The TD approach remains a valuable and preferred method for the future determination of water use in trees. However, sensor replication can fundamentally impact a study's outcomes and should be more carefully considered in study design. Customized error mitigation strategies are best to address the sources of variation most problematic for a particular study. In conclusion, the development of “smart” calibration approaches that correct for fundamental effects of radial variation inherent in thermal dissipation studies is discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Seismoacoustic Signatures Observed During a Long-Term Deployment of Infrasound Sensors at the Nevada National Security Site

Earthquakes have repeatedly been shown to produce inaudible acoustic signals (<20 Hz), otherwise known as infrasound. These signals can propagate hundreds to thousands of kilometers and still be detected by ground-based infrasound arrays depending on the source strength, distance between source and receiver, and atmospheric conditions. Another type of signal arrival at infrasound arrays is the seismic induced motion of the sensor itself, or ground-motion-induced sensor noise. Measured acoustic and seismic waves produced by earthquakes can provide insight into properties of the earthquake such as magnitude, depth, and focal mechanism, as well as information about the local lithology and atmospheric conditions. Large earthquakes that produce strong acoustic signals detected at distances greater than 100 km are the most commonly studied; however, more recent studies have found that smaller magnitude earthquakes ($M$ w <2.0) can be detected at short ranges. In that vein, this study will investigate the ability for a long-term deployment of infrasound sensors (deployed as part of the Source Physics Experiments [SPE] from 2014 to 2020) to detect both seismic and infrasonic signals from earthquakes at local ranges (<50 km). Methods used include a combination of spectral analysis and automated array processing, supported by U.S. Geological Survey earthquake bulletins. Further, this investigation revealed no clear acoustic detections for short range earthquakes. However, secondary infrasound from an $M$ w 7.1 earthquake over 200 km away was detected. Important insights were also made regarding the performance of the SPE networks including detections of other acoustic sources such as bolides and rocket launches. Finally, evaluation of the infrasound arrays is performed to provide insight into optimal deployments for targeting earthquake infrasound.

58 GEOSCIENCES↗

Novel Gas Composition Sensor for Monitoring Advanced Power Generation Systems

Power generation based on combustion will be an important part of American energy production for the foreseeable future. Optimization of the combustion process to maximize fuel efficiency and minimize harmful emissions will benefit from sensors capable of withstanding the harsh high pressure and high temperature environment typically found in the chamber. These devices must be versatile and easy to use with low probe cost in order to gain widespread acceptance and use. Physical Sciences Inc. and the research group of Prof. Scott Sanders at the University of Wisconsin have designed and demonstrated a novel sensor system for monitoring the concentration of multiple gas species in power generation systems. The system combines a novel laser from the optical telecommunications industry with a high-temperature measurement probe, sensitive detection electronics, and data processing algorithms. The Phase I program resulted in a successful demonstration of broadband spectroscopy combined with sensitive detection and chemometric algorithms to detect multiple gas species at high temperatures and pressures. A novel optical probe based on a sapphire fiber architecture that is compatible with the conditions expected in coal gasification systems was also designed. The initial target application for the proposed sensor is the monitoring of full scale, advanced power generation systems including coal gasifiers and gas turbines. The technology developed in this work may also be applied to many additional industrial processes, including continuous emission monitoring, pharmaceutical manufacturing and explosives detection. The ability to identify multiple species and measure their concentrations in a gas mixture will allow manufacturers to increase yields and reduce costs.

20 FOSSIL-FUELED POWER PLANTS↗

Ferrite-Cored Solenoidal Induction Coil Sensor for BUD (MM-1667)

We have designed and lab tested a new ferrite cored induction coil sensor for measuring the secondary fields from metallic UXO with the BUD system. The objective was to replace the 5-inch diameter air-cored coils in the BUD system with smaller sensors that would allow the placement of multiple sensors in the smaller package of the new BUD hand-held system. A ferrite-cored solenoidal coil of length L can easily be made to have sensitivity and noise level roughly the same as an air-cored coil of a diameter on the same order as L. A ferrite-cored solenoidal coil can easily have a feedback configuration to achieve critical damping. The feedback configuration leads to a very stable response. Feedback ferrite-cored solenoidal coils show very little interaction as long as they are separated by one half their length.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Characterization of Fish Passage Conditions through the Fish Weir and Turbine Unit 1 at Foster Dam, Oregon, Using Sensor Fish, 2012

Fish passage conditions through a Kaplan turbine and spillway fish weir at Foster Dam, located on the South Santiam River in Linn County, Oregon, were evaluated by Pacific Northwest National Laboratory for the U.S. Army Corps of Engineers, Portland District, using Sensor Fish devices. The objective of the study was to describe and compare passage exposure conditions, identifying potential fish injury regions encountered during passage via specific routes. The investigation was performed in May 2012, concurrent with HI-Z balloon-tag studies by Normandeau Associates, Inc. Sensor Fish data were analyzed to characterize the passage exposure conditions through the spillway fish weir and turbine Unit 1 at Foster Dam at two forebay pool elevations (616 and 634 ft mean sea level [MSL]) and to estimate data relationships with live fish injury and mortality estimates. For the spillway fish weir evaluation, Sensor Fish and live fish were deployed through injection system piping mounted on the weir. The bottom of the injection pipe was at an elevation of approximately 614 ft during testing at the 616-ft MSL (low) forebay elevation and at 632 ft during the 634-ft MSL (high) forebay level tests. Two systems were used—a 4-in. pipe for juvenile fish releases and an 8-in. pipe for adult releases at each elevation.

Duncan, Joanne P.↗

Analysis to determine the maximum dimensions of flexible apertures in sensored security netting products.

Although technological advances provide new capabilities to increase the robustness of security systems, they also potentially introduce new vulnerabilities. New capability sometimes requires new performance requirements. This paper outlines an approach to establishing a key performance requirement for an emerging intrusion detection sensor: the sensored net. Throughout the security industry, the commonly adopted standard for maximum opening size through barriers is a requirement based on square inches typically 96 square inches. Unlike standard rigid opening, the dimensions of a flexible aperture are not fixed, but variable and conformable. It is demonstrably simple for a human intruder to move through a 96-square-inch opening that is conformable to the human body. The longstanding 96-square-inch requirement itself, though firmly embedded in policy and best practice, lacks a documented empirical basis. This analysis concluded that the traditional 96-square-inch standard for openings is insufficient for flexible openings that are conformable to the human body. Instead, a circumference standard is recommended for these newer types of sensored barriers. The recommended maximum circumference for a flexible opening should be no more than 26 inches, as measured on the inside of the netting material.

Murton, Mark↗

Lightweight Integrated Optical Sensor for Atmospheric Measurements on Mobile Platforms

The goal of the Phase I program was to develop a novel open path sensor platform technology based on integration of semiconductor waveguides with efficient optoelectronic components on a monolithic platform. The successful Phase I effort resulted in demonstration of a novel optical resonator structure based on semiconductor high contrast gratings (HCGs) that will enable implementation of an ultra-compact, low-power gas sensor suitable for use on mobile platforms. Extensive numerical modeling was performed to design a device optimized for measuring CO2 at a wavelength for which a laser was available for proof of concept. Devices were fabricated and tested to match the target wavelength, angle, and operating temperature. This demonstration is the first implementation of HCGs at the wavelengths of interest and shows the flexibility of the proposed architecture for gas sensing applications. The measured cavity Q was lower than anticipated due to fabrication process challenges. The PSI and UC Berkeley team has identified solutions to these challenges and will produce optimized devices in a Phase II program where a prototype sensor will be fabricated and tested.

54 ENVIRONMENTAL SCIENCES↗

Laboratory demonstration of a multi-sensor unattended cylinder verification station for uranium enrichment plant safeguards

The objective of safeguards is the timely detection of the diversion of a significant quantity of nuclear materials, and safeguarding uranium enrichment plants is especially important in preventing the spread of nuclear weapons. The IAEA’s proposed Unattended Cylinder Verification Station (UCVS) for UF 6 cylinder verification would combine the operator’s accountancy scale with a nondestructive assay system such as the Passive Neutron Enrichment Meter (PNEM) and cylinder identification and surveillance systems. In this project, we built a laboratory-scale UCVS and demonstrated its capabilities using mock UF 6 cylinders. We developed a signal processing algorithm to automate the data collection and processing from four continuous, unattended sensors. The laboratory demonstration of the system showed that the software could successfully identify cylinders, snip sensor data at the appropriate points in time, determine the relevant characteristics of the cylinder contents, check for consistency among sensors, and output the cylinder data to a file. This paper describes the equipment, algorithm and software development, laboratory demonstration, and recommendations for a full-scale UCVS.

42 ENGINEERING↗

Development of High Temperature/High Sensitivity Novel Chemical Resistive Sensor

The research has been focused to design, fabricate, and develop high temperature/high sensitivity novel multifunctional chemical sensors for the selective detection of fossil energy gases used in power and fuel systems. By systematically studying the physical properties of the LnBaCo 2 O 5+d (LBCO) [Ln=Pr or La] thin-films, a new concept chemical sensor based high temperature chemical resistant change has been developed for the application for the next generation highly efficient and near zero emission power generation technologies. We also discovered that the superfast chemical dynamic behavior and an ultrafast surface exchange kinetics in the highly epitaxial LBCO thin films. Furthermore, our research indicates that hydrogen can superfast diffuse in the ordered oxygen vacancy structures in the highly epitaxial LBCO thin films, which suggest that the LBCO thin film not only can be an excellent candidate for the fabrication of high temperature ultra sensitive chemical sensors and control systems for power and fuel monitoring systems, but also can be an excellent candidate for the low temperature solid oxide fuel cell anode and cathode materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structured Emission Thermometry Sensor for Burner Control

The overall objective of the program is to control furnace flames for more efficient operation by applying an appropriate sensor technology in a control loop. In Phase I we measured spectra and multispectral imagery from a test furnace at Eclipse, Inc., in Rockford, IL. The test furnace was run at a variety of operating conditions with an oxy-fuel flame, fueled in some tests by natural gas and in others by propane. Using spatial, spectral, and temporal processing, several properties of the flame became observable, including the locations of principal heat release, the extent of the non-luminous portion of the flame, and the local gas temperature. Among the spectra and imagery recorded, the multi-spectral images showed the most promise as a field-compatible measurement system. In Phase II we developed algorithms, driver software, and hardware for what eventually became two independent prototypes: a sophisticated burner-mounted single line-of-sight spectral sensor and a more-mature version of the multispectral furnace imager from Phase I. The maturity of the furnace imager was advanced through significant automation of acquisition, exposure, data recording, and processing to data products. The single line of sight spectral sensor was developed using insights from the test campaigns and was applied in a practical application in an industrial facility where it was used in a control loop. The active control benefits depend on the final applications engineering but show promise to offer smaller excess-air or excess-oxygen requirements, improved response to changing fuel feed stocks, and tighter control on flame properties, resulting in a more consistent product. This thus reduces waste of fuel due to conservative excess-oxidizer requirements and also waste due to off-specification product quality.

30 DIRECT ENERGY CONVERSION↗

NEET In-Pile Ultrasonic Sensor Enablement (Final Report)

Ultrasonic technologies offer the potential to measure a range of parameters during irradiation of fuels and materials, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes under harsh irradiation test conditions. There are two primary issues that currently limit in-pile deployment of ultrasonic sensors. The first is transducer survivability. The ability of ultrasonic transducer materials to maintain their useful properties during an irradiation must be demonstrated. The second issue is signal processing. Ultrasonic testing is typically performed in a lab or field environment, where the sensor and sample are accessible. The harsh nature of in-pile testing and the variety of desired measurements demand that an enhanced signal processing capability be developed to make in-pile ultrasonic sensors viable. To address these issues, the NEET ASI program funded a three year Ultrasonic Transducer Irradiation and Signal Processing Enhancements project, which is a collaborative effort between the Idaho National Laboratory, the Pacific Northwest National Laboratory, the Argonne National Laboratory, and the Pennsylvania State University. The objective of this report is to document the objectives and accomplishments from this three year project. As summarized within this document, significant work has been accomplished during this three year project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field Evaluation of Real-time Cloud OD Sensor TWST during the DOE ARM TCAP Campaign 2013 Final Campaign Report

The objective of this internal research and development (IRAD)-funded campaign by Aerodyne Research, Inc. was to demonstrate the field-worthiness and assess the performance of a real-time cloud optical depth (COD) sensor (dubbed three-waveband spectrally-agile technique [TWST]) through a side-by-side comparison with proven, ground-based operational sensors currently deployed at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility Mobile Facility (AMF) site on the Cape Cod National Seashore for the Two-Column Aerosol Project (TCAP). We anticipated direct comparisons with the Aerosol Robotic Network (AERONET; when in cloud mode) and SAS instruments and expected ancillary data from other sensors such as the Total Sky Imager, the Scanning Cloud Radar, and the Microwave Radiometer to facilitate and validate these comparisons. Because the cloud optical depth retrieval algorithms used by AERONET, solar array spectrometer (SAS), and TWST are totally independent, this deployment provided a unique opportunity to evaluate the field performance of TWST. If the effort proves successful, it may qualify TWST for operational service or additional evaluation effort.

47 OTHER INSTRUMENTATION↗

Field Evaluation of Real-time Cloud OD Sensor TWST during the DOE ARM TCAP Campaign 2013 Final Campaign Report

The objective of this internal research and development (IRAD)-funded campaign by Aerodyne Research, Inc. was to demonstrate the field-worthiness and assess the performance of a real-time cloud optical depth (COD) sensor (dubbed three-waveband spectrally-agile technique [TWST]) through a side-by-side comparison with proven, ground-based operational sensors currently deployed at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility Mobile Facility (AMF) site on the Cape Cod National Seashore for the Two-Column Aerosol Project (TCAP). We anticipated direct comparisons with the Aerosol Robotic Network (AERONET; when in cloud mode) and SAS instruments and expected ancillary data from other sensors such as the Total Sky Imager, the Scanning Cloud Radar, and the Microwave Radiometer to facilitate and validate these comparisons. Because the cloud optical depth retrieval algorithms used by AERONET, solar array spectrometer (SAS), and TWST are totally independent, this deployment provided a unique opportunity to evaluate the field performance of TWST. If the effort proves successful, it may qualify TWST for operational service or additional evaluation effort.

54 ENVIRONMENTAL SCIENCES↗

Nanostructured Bulk Thermoelectric Generator for Efficient Power Harvesting for Self-powered Sensor Networks

The objective of this Nuclear Energy Enabling Technology research project is to develop high-efficiency and reliable thermoelectric generators for self-powered wireless sensors nodes utilizing thermal energy from nuclear plant or fuel cycle. The power harvesting technology has crosscutting significance to address critical technology gaps in monitoring nuclear plants and fuel cycle. The outcomes of the project will lead to significant advancement in sensors and instrumentation technology, reducing cost, improving monitoring reliability and therefore enhancing safety. The self-powered wireless sensor networks could support the long-term safe and economical operation of all the reactor designs and fuel cycle concepts, as well as spent fuel storage and many other nuclear science and engineering applications. The research is based on recent breakthroughs in high-performance nanostructured bulk (nanobulk) thermoelectric materials that enable high-efficiency direct heat-to-electricity conversion over a wide temperature range. The nanobulk thermoelectric materials that the research team at Boise State University and University of Houston has developed yield up to a 50% increase in the thermoelectric figure of merit, ZT, compared with state-of-the-art bulk counterparts. This report focuses on the selection of optimal thermoelectric materials for this project. The team has performed extensive study on two thermoelectric materials systems, i.e. the half-Heusler materials, and the Bismuth-Telluride materials. The report contains our recent research results on the fabrication, characterization and thermoelectric property measurements of these two materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗