Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SEALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

ECAR-7813 Rev 0 Secondary Coolant Cover Gas System Stirling Engine Tube Rupture Analysis, Insulation Block Analysis, and Labyrinth Seal Design

The purpose of this ECAR is to document compliance with best engineering practices for the Secondary Coolant Cover Gas System of the MARVEL microreactor which includes a Stirling Engine helium tube rupture analysis, an analysis to verify the strength of the insulation blocks, and the design of the Labyrinth Seal.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Sealing of fractures in a representative CO 2 reservoir caprock by migration of fines

The impact of fines migration on fracture transmissivity reduction was investigated by injecting a brine solution containing a suspension of 0.1 wt. % kaolinite particles with a mean particle size distribution of 9.6 µm through fractured shale core samples. The fractures had apertures estimated to be approximately 100 µm. A mass balance approach was used to determine the quantity of kaolinite that was deposited within the fractures (influent – effluent = amount deposited in fractures). Large fractions (44 to 90%) of the suspended kaolinite pumped through the fractures were deposited within the fractures. Based on fracture volumes estimated with X-ray computed tomography, it was determined that approximately 10 to 17% of the fracture volume was filled with kaolinite at the point when flow was completely restricted. These results indicate that 100 µm fractures in CO 2 reservoir caprocks could be sealed within hours if the brines passing through the fractures contain a proportional volume of particulates to the tests performed in this laboratory study.

04 OIL SHALES AND TAR SANDS↗

Percutaneous BioOrganic Sealing of Duodenal Fistulas: Case Report and Review of Biological Sealants with Potential Use in Interventional Radiology

Biological sealants are being increasingly used in a variety of surgical specialties for their hemostatic and sealing capabilities. However, their use in interventional radiology has not been widely reported. The authors describe a case of duodenal perforation occurring after 15 years of gastric bypass surgery, in whom surgical diversion was unsuccessfully attempted and the leakage was successfully controlled using percutaneous administration of a combination of biological and organic sealants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Embolisation of Proximal Type 1 Endoleaks Following Endovascular Aneurysm Sealing (EVAS) Using the Nellix Device: Technique and Outcomes

AimTo evaluate the technical success and mid-term outcomes following transcatheter embolisation of type 1a endoleak after Nellix endovascular aneurysm sealing (EVAS).Materials and MethodsSeven patients (5 men; mean age 83; range 79–90) underwent transcatheter embolisation between July 2013 and August 2014. The average time from EVAS to embolisation was 136 days (range 6–301) and from endoleak diagnosis to embolisation was 20 days (range 2–50). Embolisation was performed with coils and Onyx in six cases and Onyx only in one case. Technical success, imaging and clinical outcomes of embolisation were reviewed. Technical success was defined as elimination of the endoleak on completion angiography and first imaging follow-up. Clinical success was defined as unchanged or decreased aneurysm sac size on subsequent follow-up (average 8 months; range 103–471 days).ResultsAll cases were technically successful. One patient required a second endovascular procedure following Onyx reflux into the Nellix endograft and another patient required surgical closure of a brachial puncture site. All patients are endoleak free with stable sac size on the latest available follow-up imaging.ConclusionIf a type 1 endoleak occurs after EVAS, embolisation using Onyx with or without coils is feasible and effective with high technical success and freedom from endoleak recurrence at mid-term follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Enlargement of Aneurysmal Sac and Separation of EndoBags of Nellix Endovascular Aneurysm Sealing System as Signs of Increased Risk of Later Aneurysm Rupture

Nellix Endovascular Aneurysm Sealing (EVAS) system is a new concept and technology of abdominal aortic aneurysm (AAA) repair. Elective EVAS using Nellix device was performed for a 83-year-old man with AAA. 2-month post-EVAS CTA surveillance demonstrated mild enlargement of aneurysmal sac and separation of the EndoBags, but without detectable endoleak. The patient developed sudden AAA rupture with retroperitoneal hematoma at about 4 months after EVAS. We postulated that early enlargement of aneurysmal sac and separation of EndoBags of Nellix devices after EVAS, even without detectable endoleak, might indicate significant aneurysmal wall weakening with increased risk of later AAA rupture. To the best of the authors’ knowledge, this was the first reported case of aortic rupture after EVAS without detectable endoleak during and after the procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Histologic Analysis with the Newly Designed Exoskeleton Seal{sup ®} Stent-Graft in the Porcine Abdominal Aorta

Purpose: To investigate the technical feasibility of a novel exoskeleton Seal{sup ®} stent-graft and analyze early histologic changes in the porcine abdominal aorta. Materials and Methods: Six pigs received an abdominal stent-graft (Group I), and six received an iliac branch stent-graft (Group II). Groups were subdivided as follows: Group Ia, which received three bifurcated main-body stent-grafts; Group Ib, which received three bifurcated main-body stent-grafts with both iliac graft-stents; Group IIa, which received three simple uni-iliac tapered stent-grafts; and Group IIb, which received three uni-iliac tapered tapered stent-grafts with right straight limb and left branched limb. Statistical analyses were performed with the Wilcoxon signed-rank test and mixed-model regression analysis. Results: The primary technical success rate (< 24 h) was 83% because of two acute thromboses in the lumen of the stented abdominal aorta immediately after stent-graft placement. At 4 weeks, late thrombosis occurred in two pigs. Higher mean neointimal hyperplasia areas (23.5% vs. 16.2%; P = .047), neointimal hyperplasia thicknesses (545.5 μm vs. 422.2 μm; P = .001), and degrees of collagen deposition (2.71 vs. 2.33; P = .002) were observed at the bare-metal stent-graft compared with the proximal exoskeleton portion of the stent-graft, with no significant differences between the patent and occluded groups or among the four types of stent-grafts. Conclusions: The exoskeleton stent-graft demonstrates 66% of patency rate during 1-month follow-up due to four cases of thromboses; however, the endothelialization on the junction of proximal graft showed no significant differences between the patent and occluded groups. Further studies should investigate long-term outcomes with prolonged neointimal hyperplasia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy Characteristics of Neutrons from Generators with Sealed Tubes

The factors affecting the energy of neutrons produced in generators with sealed tubes are presented. The change in the energy of neutrons interacting with the structural materials of the generator is not examined. The analysis will be useful to specialists doing practical work with neutron generators.

07 ISOTOPE AND RADIATION SOURCES↗

National nuclear forensics libraries: a case study on benefits and possibilities for identification of sealed radioactive sources

A National Nuclear Forensic Library (NNFL) is a useful nuclear forensics tool which consists of information and subject matter expertise on radioactive and nuclear (RN) materials produced, used or stored within a State. If RN material is found out of regulatory control the NNFL can be used as part of a nuclear forensics investigation to help identify whether or not the material is consistent with a country’s national holdings. In previous work, a number of signatures which can be useful to identify sealed sources of 241 Am were investigated. To validate the measurement results, an official query concerning information about two of the previously investigated 241 Am sources was sent to the United States Department of State, the international point-of-contact (POC) for the U.S. NNFL. The aim of this work is to show how data obtained in a characterization of a radioactive source can be used in conjunction with an NNFL to investigate the history of a source out of regulatory control.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electrospray Generated from the Tip-Sealed Fine Glass Capillary Inserted with an Acupuncture Needle Electrode

In electrospray, excess charges are supplied to a sample solution by the occurrence of electrochemical reactions. Recently, different versions of electrospray, e.g., dielectric barrier electrospray ionization, inductive desorption electrospray ionization, and electrostatic-ionization driven by dielectric polarization, have been reported in which the sample solution was not in direct contact with the metal electrode but separated by dielectric materials. The objective of the current work is to elucidate the mechanism of dielectric barrier electrospray. A sealed borosilicate glass capillary inserted with a fine acupuncture needle was used as a probe. A sample solution (~ 400 nL) was captured on the glass capillary tip and a positive high voltage (HV) pulse (+ 4.5 kV) was applied to the internal metal electrode. Mass spectra were measured as a function of the HV pulse width from μs to 10 s. Ions started to be detected with the pulse width of ~ 5 ms. The ion intensities increased slowly with time and reached a plateau in a few seconds. The charge distribution of cytochrome c [M + nH]{sup n+} shifted to higher n values from a few ms to seconds. In addition to cone-jet mode normal electrospray that lasted until all the liquid sample was depleted from the glass tip, the polarization-induced electrospray ionization was observed at the early stage of the HV application. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using high pressure solutions of polyfluoroacrylate and CO 2 to Seal cement cracks for improved wellbore integrity

Polyfluoroacrylate (PFA) is a hydrophobic and oleophobic polymer that is soluble in high pressure carbon dioxide (CO 2 ). In this study, the ability of PFA-CO 2 solutions to greatly reduce the apparent permeability of split or cracked Portland cement cylindrical samples is assessed. The apparent permeability values of confined samples were determined before and after treatment with PFA-CO 2 solutions. In four tests, PFA-CO 2 solutions were continuously displacing pure CO 2 from the cracked cement and the decrease in apparent permeability due to PFA adsorption and wettability alteration was monitored. The lowest apparent permeability cracked cement sample (81 nD) was completely sealed with a very small amount of solution. Samples with initial apparent permeabilities of 89 μD and 29.4 mD exhibited 92% and 99% reductions in permeability, respectively, before the experiments had to be stopped because of the excessively large increase in pressure drop. A 50% reduction in apparent permeability was observed with a 3.80 mD sample. Four other split cement samples (bound together with tape) with an initial apparent permeability in the 9.0–70 mD range were removed from the core holder and immersed in a PFA-CO 2 solution for 24 h to allow for PFA adsorption. Then the PFA-CO 2 solution was depressurized, allowing for the deposition of additional PFA from the solution within the crack as the pressure fell below the cloud point pressure of the PFA-CO 2 solution. These four samples were then confined again in a core holder and apparent permeability reductions of 29–93% were observed. Finally, results from these eight experiments indicates that the more substantial reductions in the nD – mD apparent permeability of the cracked cement correlated to lower initial crack permeability, higher PFA concentration, and slower injection rate of the PFA-CO 2 solution into the crack.

58 GEOSCIENCES↗

Numerical assessment of fault impact on caprock seals during CO 2 sequestration

Coupled fluid-flow and geomechanical analysis of caprock integrity has gained a lot of attention among scientists and researchers investigating the long-term performance of geologic carbon storage systems. Reactivation of pre-existing fractures within the caprock or re-opening of faults can create permeable pathways which can influence the seal integrity. Stability of the caprock during and after injection of super-critical CO 2 , and the impact of pre-existing fractures in the presence or absence of one or multiple faults have been investigated in this study. The impact of the wellbore orientation and the injection rate are among other key factors in understanding the structural trapping mechanisms within such geological formations. In this study, we numerically investigated the impact of each of these factors. This study revealed the interplay between joints and faults and how different leakage pathways are formed and under which scenario they play a dominant role in terms of CO 2 leakage. Finally, this study also highlights the role of one versus multiple faults in the domain and the importance of the fault hydrological property in forming leakage pathway.

58 GEOSCIENCES↗

Incorporation and distribution of rhenium in a borosilicate glass melt heat treated in a sealed ampoule

We investigated a mass balance of rhenium (used as a surrogate for technetium-99) in a borosilicate glass that was mixed with excess Re source (KReO4) beyond its solubility and heat treated in a vacuum-sealed fused silica ampoule. Distribution of Re in the bulk of the glass, in a salt phase formed on the melt surface, and in condensate material deposited on the ampoule wall was evaluated to understand the Re migration into different phases during the reaction between the molten glass and KReO4. The information gained from this study will contribute to an effort to understand the mechanism of technetium retention in or escape from glass melt during early stages of glass batch melting, which is a goal of the present series of studies.

borosilicate glass↗

Statistical Continuum Mechanics Analysis of Effective Elastic Properties in Solid Oxide Fuel Cell Glass–Ceramic Seal Material

A full statistical analysis of the microstructure of glass–ceramic solid oxide fuel cell (SOFC) seal material, G18, is performed to calculate elastic properties. Predictions are made for samples aged for 4 h and 1000 h, giving different crystallinity levels. Microstructure of the glass–ceramic G18 is characterized by correlation function for each individual phase. Predicted results are compared with the Voigt and Reuss bounds in this study. The weak contrast analysis results in elastic modulus predictions between the upper and lower bounds but closer to the upper bound.

Milhans, Jacqueline↗

Mechanical properties of solid oxide fuel cell glass-ceramic seal at high temperatures

Mechanical properties of solid oxide fuel cell glass-ceramic seal material, G18, are studied at high temperatures. Samples of G18 are aged for either 4h or 100h, resulting in samples with different crystallinity. Reduced modulus, hardness, and time-dependent behavior are measured by nanoindentation. The nanoindentation is performed at room temperature, 550, 650, and 750°C, using loading rates of 5 mN/s and 25 mN/s. Results show a decrease in reduced modulus with increasing temperature, with significant decrease above the glass transition temperature (Tg). Hardness generally decreases with increasing temperature, with a slight increase before Tg for the 4h aged sample. Dwell tests show that creep increases with increasing temperature, but decrease with further aging.

30 DIRECT ENERGY CONVERSION↗

Polarizing 3 He via metastability exchange optical pumping using a 1.2 mbar sealed cell at magnetic fields up to 5 T

Here, we report high nuclear polarization of 1.2 mbar 3 He gas in a sealed cell in magnetic fields up to 5 T using Metastability Exchange Optical Pumping (MEOP). The creation of a highly polarized 3 He gas target for use in the 5 T field of Jefferson Lab’s CLAS12 spectrometer would enable new studies of spin-dependent asymmetries on the neutron. We describe a systematic study which was conducted for the first time up to the full 5 T field required for the final target design to evaluate the effects of discharge intensity, pump laser power, and optical pumping transition schemes on nuclear polarization and pumping rates. Steady-state polarizations up to 86% in magnetic fields between 2 and 5 T were achieved, with a discharge-on relaxation time of 898 s at 5 T. These results underscore the potential of MEOP for high-field applications in nuclear physics experiments.

3He polarization↗

Gastight Hydrodynamic Electrochemistry: Design for a Hermetically Sealed Rotating Disk Electrode Cell

Rotating disk electrodes (RDEs) are widely used in electrochemical characterization to analyze the mechanisms of various electrocatalytic reactions. RDE experiments often make use of or require collection and quantification of gaseous products. The combination of rotating parts and gaseous analytes makes the design of RDE cells that allow for headspace analysis challenging due to gas leaks at the interface of the cell body and the rotator. In this manuscript we describe a new, hermetically sealed electrochemical cell that allows for electrode rotation while simultaneously providing a gastight environment. Electrode rotation in this new cell design is controlled by magnetically coupling the working electrode to a rotating magnetic driver. Calibration of the RDE using a tachometer shows that the rotation speed of the electrode is the same as that of the magnetic driver. To validate the performance of this cell for hydrodynamic measurements, limiting currents from the reduction of a potassium ferrocyanide (K 4 [Fe(CN) 6 ]·3H 2 O) were measured and shown to compare favorably with calculated values from the Levich equation and with data obtained using more typical, nongastight RDE cells. Faradaic efficiencies of ~95% were measured in the gas phase for oxygen evolution in alkaline media at an Inconel 625 alloy electrocatalyst during rotation at 1600 rpm. These data verify that a gastight environment is maintained even during rotation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanofiltration across Defect-Sealed Nanoporous Monolayer Graphene

Monolayer nanoporous graphene represents an ideal membrane for molecular separations, but its practical realization is impeded by leakage through defects in the ultrathin graphene. Here, we report a multiscale leakage-sealing process that exploits the nonpolar nature and impermeability of pristine graphene to selectively block defects, resulting in a centimeter-scale membrane that can separate two fluid reservoirs by an atomically thin layer of graphene. After introducing subnanometer pores in graphene, the membrane exhibited rejection of multivalent ions and small molecules and water flux consistent with prior molecular dynamics simulations. The results indicate the feasibility of constructing defect-tolerant monolayer graphene membranes for nanofiltration, desalination, and other separation processes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multifunctional Silk Fibroin Hydrogels with Strong Adhesion for Tissue Sealing and Wearable Electronic Sensors

Multifunctional hydrogels with excellent adhesion, biodegradability, and conductivity are essential for overcoming the obstacles of postoperative secondary injury, flexible sensing instability, and so on. Herein, we develop a multifunctional silk fibroin (SF) hydrogel modified with poly(acrylic acid). Owing to the stable chemical cross-linking network and the abundant carboxylic acid groups of the SF network, the SF hydrogel exhibits a high tensile strength of 74.34 kPa due to sufficient cohesion and interfacial interactions. Additionally, the tensile strain reaches a maximum of 414.6%, the compressive strength is 0.9 MPa, and the shear adhesive strength for pig skin tissues is as high as 64 kPa. Compared with most hydrogels, our multifunctional SF hydrogel with a low swelling ratio provides excellent adhesion, biodegradation, and conductivity, which shows advantages in terms of invasive tissue sealing. Furthermore, the use of self-adhesive SF hydrogels as conductive hydrogels in flexible sensors also benefits the collection of physiological electricity and human motion signals in the field of wearable and implantable electronic devices.

adhesive↗