Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “S Parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Parameter study of acceleration of externally injected electrons in the linear laser wakefield regime

A parameter study for laser wakefield acceleration is presented, in which externally injected electrons are accelerated in low amplitude plasma waves, represented by an analytical two-dimensional description. Results have been obtained for plasma densities up to 2.6x10{sup 24} m{sup -3}, plasma lengths up to 300 mm, laser intensities up to 3.5x10{sup 21} W/m{sup 2}, and injection of Gaussian model bunches at energies up to 12 MeV. For the range of parameters studied, effects of laser depletion and the influence of the electron bunch on the plasma can be ignored. In the parameter space, a region is identified where final energies of over 100 MeV are reached, at an energy spread of less than 5% and a rms emittance of a few micrometers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stark parameters irregularities of Xe II lines obtained by transitions from ({sup 3}P{sub 1})6plevels

Stark widths and shifts of some Xe II lines belonging to the supermultiplets with upper levels ({sup 3}P{sub 1})6p were measured using a pulsed discharge lamp. Plasma parameters, i.e. electron density and temperature, in this experiment were in the range from 0.2 to 1.4x10{sup 23} m{sup -3} and from 18000 to 23000 K, respectively. Lines obtained by transitions from levels ({sup 3}P{sub 1})6p show some strong intra-supermultiplet irregularities in their Stark widths and shifts. These results and the measurements obtained in previous works were used here to analyse the main irregularities that can appear in the case of Xe II. This study may be very useful for obtaining Stark parameters of non-measured lines, using the known parameters of other lines belonging to similar transitions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extraction of SUSY Parameters from Collider Data

The extraction of the parameters of the supersymmetric Lagrangian is discussed. Particular emphasis is put on the rigorous treatment of experimental and theoretical errors. While the LHC can provide a valuable first estimate of the parameters, the combination of LHC and ILC will be necessary to determine with high precision the parameters of the MSSM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real-Time Parameter Estimation Method Applied to a MIMO Process and its Comparison with an Offline Identification Method

An experiment based method is proposed for parameter estimation of a class of linear multivariable systems. The method was applied to a pressure-level control process. Experimental time domain input/output data was utilized in a gray-box modeling approach. Prior knowledge of the form of the system transfer function matrix elements is assumed to be known. Continuous-time system transfer function matrix parameters were estimated in real-time by the least-squares method. Simulation results of experimentally determined system transfer function matrix compare very well with the experimental results. For comparison and as an alternative to the proposed real-time estimation method, we also implemented an offline identification method using artificial neural networks and obtained fairly good results. The proposed methods can be implemented conveniently on a desktop PC equipped with a data acquisition board for parameter estimation of moderately complex linear multivariable systems.

99 GENERAL AND MISCELLANEOUS↗

A metamodeling approach for studying ignition target robustness in a highly dimensional parameter space

Inertial confinement fusion targets must be carefully designed to ignite their central hot spots and burn. Changes in the optimal implosion could reduce the fusion energy or even prevent ignition. Since there are unavoidable uncertainties due to technological defects and not perfect reproducibility from shot to shot, the fusion energy will remain uncertain. The degree with which a target can tolerate larger specifications than specified, and the probability with which a particular yield is exceeded, are possible measures of the robustness of that design. This robustness must be assessed in a very high-dimensional parameter space whose variables include every characteristics of the given target and of the associated laser pulse shape, using high-fidelity simulations. Therefore, these studies would remain computationally very intensive. In this paper we propose an approach which consist first of constructing an accurate metamodel of the yield on the whole parameter space with a reasonable data set of simulations. Then the robustness is very quickly assessed for any set of specifications with this surrogate. The yield is approximated by a neural network, and an iterative method adds new points in the data set by means of D-optimal experimental designs. The robustness study of the baseline Laser Megajoule target against one-dimensional defects illustrates this approach. A set of 2000 simulations is sufficient to metamodel the fusion energy on a large 22-dimensional parameter space around the nominal point. Furthermore, a metamodel of the robustness margin against all specifications has been obtained, providing guidance for target fabrication research and development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

'PSA-SPN' - A Parameter Sensitivity Analysis Method Using Stochastic Petri Nets: Application to a Production Line System

The dynamic behavior of a discrete event dynamic system can be significantly affected for some uncertain changes in its decision parameters. So, parameter sensitivity analysis would be a useful way in studying the effects of these changes on the system performance. In the past, the sensitivity analysis approaches are frequently based on simulation models. In recent years, formal methods based on stochastic process including Markov process are proposed in the literature. In this paper, we are interested in the parameter sensitivity analysis of discrete event dynamic systems by using stochastic Petri nets models as a tool for modelling and performance evaluation. A sensitivity analysis approach based on stochastic Petri nets, called PSA-SPN method, will be proposed with an application to a production line system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tailoring carbon nanotips in the plasma-assisted chemical vapor deposition: Effect of the process parameters

Carbon nanotips have been synthesized from a thin carbon film deposited on silicon by bias-enhanced hot filament chemical vapor deposition under different process parameters. The results of scanning electron microscopy indicate that high-quality carbon nanotips can only be obtained under conditions when the ion flux is effectively drawn from the plasma sustained in a CH{sub 4}+NH{sub 3}+H{sub 2} gas mixture. It is shown that the morphology of the carbon nanotips can be controlled by varying the process parameters such as the applied bias, gas pressure, and the NH{sub 3}/H{sub 2} mass flow ratios. The nanotip formation process is examined through a model that accounts for surface diffusion, in addition to sputtering and deposition processes included in the existing models. This model makes it possible to explain the major difference in the morphologies of the carbon nanotips formed without and with the aid of the plasma as well as to interpret the changes of their aspect ratio caused by the variation in the ion/gas fluxes. Viable ways to optimize the plasma-based process parameters to synthesize high-quality carbon nanotips are suggested. The results are relevant to the development of advanced plasma-/ion-assisted methods of nanoscale synthesis and processing.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Discharge parameters and dominant electron conductivity mechanism in a low-pressure planar magnetron discharge

Parameters of a discharge sustained in a planar magnetron configuration with crossed electric and magnetic fields are studied experimentally and numerically. By comparing the data obtained in the experiment with the results of calculations made using the proposed theoretical model, conclusion was made about the leading role of the turbulence-driven Bohm electron conductivity in the low-pressure operation mode (up to 1 Pa) of the discharge in crossed electric and magnetic fields. A strong dependence of the width of the cathode sputter trench, associated with the ionization region of the magnetron discharge, on the discharge parameters was observed in the experiments. The experimental data were used as input parameters in the discharge model that describes the motion of secondary electrons across the magnetic field in the ionization region and takes into account the classical, near-wall, and Bohm mechanisms of electron conductivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determination of Resonance Parameters by Use of Pade III Approximation

Analytic continuation in the coupling constant is studied by means of the statistical Pade approximation (Pade III approximation). The method is used to calculate resonance energies and widths for model potential, consisting of two Dirac {delta}-functions, which allows for an analytic solution of the scattering problem. Bound states are determined for a range of coupling parameters and the resonance parameters are then obtained by the analytic continuation. The role of selection of the input data on the calculated resonance parameters is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect Of Changing Laser Irradiance On The Laser Induced Plasma Parameters For Au/Cu Layered Target

Pulsed laser induced plasma (LIP) has a very short temporal existence. Due to the transient nature of the produced LIP, with a fast evolution of its characteristic parameters, these parameters are heavily dependent on the irradiation conditions such as incident laser intensity, irradiation spot size, ambient gas composition and pressure. It is also true that these parameters vary drastically with axial or radial distance from the target surface under the same irradiation. In the present work depth profiling measurements of gold film onto copper substrate have been performed and the effect of changing laser irradiance by changing the working distance on both electron density and electron temperature has been also studied.

36 MATERIALS SCIENCE↗

Etching characteristics of organic low-k films interpreted by internal parameters employing a combinatorial plasma process in an inductively coupled H{sub 2}/N{sub 2} plasma

The development of plasma etching technology is being held back due to the use of trial and error methods when scaling down and high integration. Such a continuous development could result in enormous losses in term of cost and time. It is impossible to overcome without a different approach. In this study, we have tried to accumulate a large amount of data on internal parameters and based on database, the etching characteristics could be interpreted with a high reproducibility. In order to realized faster data acquisitions, we developed a combinatorial plasma process (CPP) for obtaining a large amount of data in a single trial from spatially inhomogeneous plasma distribution regarding etching of organic low-k films in H{sub 2}/N{sub 2} plasmas. In addition, synergetic effects of other internal parameters such as vacuum ultraviolet radiation and radicals without ion bombardment were clarified. Finally, the high performance of CPP for faster data acquisitions was shown and the etching characteristics in terms of internal parameters such as ion fluxes and the H/(H+N) radical flux ratio were demonstrated.

36 MATERIALS SCIENCE↗

Study on the Effect of Energy Parameter of Electron on the Percentage Depth Dose of Electron Beam Using Monte Carlo Method

In medical linear accelerator, the energy parameter of electron plays important role to produce electron beam. The percentage depth dose of electron beams takes account not only on the value of electron's energy, but also on the type of electron's energy. The aims of this work are to carry on the effect of energy parameter of electron on the percentage depth dose of electron beam. Monte Carlo method is chosen in this project, due to the superior of this method for simulating the random process such as the transport particle in matter. The DOSXYZnrc usercode was used to simulate the electron transport in water phantom. Two aspects of electron's energy parameter were investigated using Monte Carlo simulations. In the first aspect, electron energy's value was varied also its spectrum. In the second aspect, the geometry of electron's energy was taken account on. The parallel beam and the point source were chosen as the geometry of The measurements of percentage depth dose were conducted to compare with its simulation. The ionization chamber was used in these measurements. Presentation of the results of this work is given not only based on the shape of the percentage depth dose from the simulation and measurement, but also on the other aspect in its curve. The result of comparison between the simulation and its measurement shows that the shape of its curve depends on the energy value of electron and the type of its energy. The energy value of electron affected the depth maximum of dose.

07 ISOTOPE AND RADIATION SOURCES↗

Non-invasive determination of the parameters of strongly coupled 2D Yukawa liquids

We derive a method for identifying the Yukawa model parameters of two-dimensional (2D) strongly coupled dusty plasmas. The method is based on non-invasive observation of the dust component of the plasma and comparison with a large body of simulation data in the form of simple analytical formulas. This approach requires only input from a time-series of configuration snapshots and particle velocities with no recourse to additional information about the system. In addition, we derive an effective coupling parameter for 2D Yukawa systems based on the height of the first maximum of the pair distribution function. Two variants--one valid in the high-coupling range, the other for arbitrary couplings of the liquid--are derived. Comparison to previous approaches to Yukawa coupling parameters shows that the present concept is more general and more accurate. Our results should be directly applicable as a simple, yet reliable diagnostic method for a variety of experiments, including dusty plasmas, colloidal suspensions, and ions in traps, and can be employed to facilitate comparisons between experiments, theory, and simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-0.1 nm-resolution quantitative scanning transmission electron microscopy without adjustable parameters

Atomic-resolution imaging in the scanning transmission electron microscope (STEM) constitutes a powerful tool for nanostructure characterization. Here, we demonstrate the quantitative interpretation of atomic-resolution high-angle annular dark-field (ADF) STEM images using an approach that does not rely on adjustable parameters. We measure independently the instrumental parameters that affect sub-0.1 nm-resolution ADF images, quantify their individual and collective contributions to the image intensity, and show that knowledge of these parameters enables a quantitative interpretation of the absolute intensity and contrast across all accessible spatial frequencies. The analysis also provides a method for the in-situ measurement of the STEM's effective source distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of hydrogen and oxygen defects on the lattice parameter of chemical vapor deposited zinc sulfide

The lattice parameter of cubic chemical vapor deposited (CVD) ZnS with measured oxygen concentrations < 0.6 at.% and hydrogen impurities of < 0.015 at.% have been measured and found to vary between -0.10% and +0.09% relative to the reference lattice parameter (5.4093 Å) of oxygen-free cubic ZnS as reported in the literature. Defects other than substitutional O must be invoked to explain these observed volume changes. The structure and thermodynamic stability of a wide range of native and impurity induced defects in ZnS have been determined by Ab initio calculations. Lattice contraction is caused by S-vacancies, substitutional O on S sites, Zn vacancies, H in S vacancies, peroxy defects, and dissociated water in S-vacancies. The lattice is expanded by interstitial H, H in Zn vacancies, dihydroxy defects, interstitial oxygen, Zn and [ZnHn] complexes (n=1,…,4), interstitial Zn, and S2 dumbbells. Oxygen, though present, likely forms substitutional defects for sulfur resulting in lattice contraction rather than as interstitial oxygen resulting in lattice expansion. It is concluded based on measurement and calculations that excess zinc atoms either at anti-sites (i.e. Zn atoms on S-sites) or possibly as interstitial Zn are responsible for the relative increase of the lattice parameter of commercially produced CVD ZnS.

ab initio↗

Anisotropic parameter estimation using velocity variation with offset analysis

Seismic anisotropy is defined as velocity dependent upon angle or offset. Knowledge about anisotropy effect on seismic data is important in amplitude analysis, stacking process and time to depth conversion. Due to this anisotropic effect, reflector can not be flattened using single velocity based on hyperbolic moveout equation. Therefore, after normal moveout correction, there will still be residual moveout that relates to velocity information. This research aims to obtain anisotropic parameters, ε and δ, using two proposed methods. The first method is called velocity variation with offset (VVO) which is based on simplification of weak anisotropy equation. In VVO method, velocity at each offset is calculated and plotted to obtain vertical velocity and parameter δ. The second method is inversion method using linear approach where vertical velocity, δ, and ε is estimated simultaneously. Both methods are tested on synthetic models using ray-tracing forward modelling. Results show that δ value can be estimated appropriately using both methods. Meanwhile, inversion based method give better estimation for obtaining ε value. This study shows that estimation on anisotropic parameters rely on the accuracy of normal moveout velocity, residual moveout and offset to angle transformation.

58 GEOSCIENCES↗

Origin of parameter degeneracy and molecular shape relationships in geometric-flow calculations of solvation free energies

Implicit solvent models are important tools for calculating solvation free energies for chemical and biophysical studies since they require fewer computational resources but can achieve accuracy comparable to that of explicit-solvent models. In past papers, geometric flow-based solvation models have been established for solvation analysis of small and large compounds. In the present work, the use of realistic experiment-based parameter choices for the geometric flow models is studied. We find that the experimental parameters of solvent internal pressure p = 172 MPa and surface tension γ = 72 mN/m produce solvation free energies within 1 RT of the global minimum root-mean-squared deviation from experimental data over the expanded set. Our results demonstrate that experimental values can be used for geometric flow solvent model parameters, thus eliminating the need for additional parameterization. We also examine the correlations between optimal values of p and γ which are strongly anti-correlated. Geometric analysis of the small molecule test set shows that these results are inter-connected with an approximately linear relationship between area and volume in the range of molecular sizes spanned by the data set. In spite of this considerable degeneracy between the surface tension and pressure terms in the model, both terms are important for the broader applicability of the model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved measurement of plasma parameters by means of triple probe

Triple Langmuir probe (TLP) diagnostic system with its necessary driving circuit is developed and successfully applies for time-resolved measurement of plasma parameters in the negative glow region of pulsating-dc discharge. This technique allows the instantaneous measurement of electron temperature [T{sub −}], electron number density [n{sub −}] as well as plasma fluctuations without any voltage or frequency sweep. In TLP configuration two probes are differentially biased and serve as a floating symmetric double probe whereas the third probe is simply floating into plasma to measure floating potential as a function of time and thus incorporates the effect of plasma fluctuations. As an example of the application to time-dependent plasmas, basic plasma parameters such as floating potential, electron temperature, and electron number density in low pressure air discharge are determined as a function of time for different fill pressure. The results demonstrate temporal evolution of plasma parameters and thus plasma generation progression for different fill pressures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗