Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Nuclear Data – Benchmarking 19 F(α,n) Yield Data for Nuclear Safeguards

Fluorine compounds of U and Pu are ubiquitous in the nuclear fuel cycle, so F(α,n) neutrons are an important signature and quantitative source term that needs to be understood for physics-based interpretation of nondestructive assay measurements. Historically there have been large differences in the basic nuclear data for this reaction reported by various groups. UF 6 is the most prominent material in the nuclear fuel cycle, with the potential for short-term production into weaponizable form. Verification of bulk quantities, natural feed, depleted tails, and especially low enriched product in cylinders is particularly important. The principal physical measurement is neutron counting. For enriched material, the 19 F(α,n) reaction, driven by 234U, is the dominant source of neutrons. Basic nuclear data, cross sections, needed to calculate the yield, as well as information on the source spectrum for sensitivity studies are sparse and highly discrepant. This limits defensible physics-based performance evaluations. The same applies to holdup and criticality studies in which hydrated uranyl fluoride is the material of interest which accumulates in enrichment facilities. In the future we anticipate that the physics community will have made improved accelerator-based measurements and undertaken a more thorough evaluation and adjustment of all relevant available data. But in the short term, this does not help the safeguards community face the pressing real-world nondestructive assay requirements. To address this need, we have performed quality neutron measurements on UF6 materials using well-known material and high-capability neutron counters. A robust determination of the n/s/g of 234 U in UF 6 was generated along with a scientifically defensible uncertainty analysis. The weighted average value of the neutron yield is 509 n/s/g 234 U with a random uncertainty of approximately 1%. Dominant sources of systematic uncertainty are in the efficiency determination where we incur approximately 1.1% relative standard deviation associated with the 252 Cf reference source and about 0.9% uncertainty coming from the uncertainty in the F(α,n) spectrum. The stated uncertainties are an order of magnitude better than current data based on accelerator data reported in the literature. Aside from being of immediate and direct use by the safeguards community, this result will serve as an enduring integral benchmark for subsequent data evaluations that will need to match it in order to be credible. In addition to yield normalization, safeguards users of F(α,n) data also need guidance of the neutron emission spectrum. We have generated a neutron emission using a modified version of the well-known SOURCES 4C code, updated with new alpha stopping power coefficients, and a blended microscopic cross section data set. The yield and spectra are available in a form that MCNP users can readily use.

36 MATERIALS SCIENCE↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Method, apparatus and system to compensate for drift by physically unclonable function circuitry

Techniques and mechanisms to detect and compensate for drift by a physically uncloneable function (PUF) circuit. In an embodiment, first state information is registered as reference information to be made available for subsequent evaluation of whether drift by PUF circuitry has occurred. The first state information is associated with a first error correction strength. The first state information is generated based on a first PUF value output by the PUF circuitry. In another embodiment, second state information is determined based on a second PUF value that is output by the PUF circuitry. An evaluation of whether drift has occurred is performed based on the first state information and the second state information, the evaluation including determining whether a threshold error correction strength is exceeded concurrent with a magnitude of error being less than the first error correction strength.

97 MATHEMATICS AND COMPUTING↗

Pyranometers and Reference Cells, What's the Difference?: Preprint

As the photovoltaic industry has grown exponentially in the past decade, large photovoltaic (PV) fields have become more common. The investors for these projects calculate the expected return on investment based on expected electricity generation and adjust the interest rates and other financial terms according to the perceived risk. These calculations usually assume worst case according to thelisted warranty and any uncertainty in the measurement is translated directly into a reduced predicted performance. Because a 1% difference in predicted output could represent a large fraction of the expected return on investment, a small reduction in uncertainty translates into a much larger value to the entity making investment decisions. To reduce perceived risk in large-scale solarinvestments power plant performance (or production) guarantees have become increasingly common. This two part article explores some subtleties of accurately measuring PV efficiency in the field.

14 SOLAR ENERGY↗

Far-UV spectroscopy of the planet-hosting star WASP-13: High-energy irradiance, distance, age, planetary mass-loss rate, and circumstellar environment

Several transiting hot Jupiters orbit relatively inactive main-sequence stars. For some of those, the logR{sub HK}{sup ′} activity parameter lies below the basal level (−5.1). Two explanations have been proposed so far: (i) the planet affects the stellar dynamo, (ii) the logR{sub HK}{sup ′} measurements are biased by extrinsic absorption, either by the interstellar medium (ISM) or by material local to the system. We present here Hubble Space Telescope/COS far-UV spectra of WASP-13, which hosts an inflated hot Jupiter and has a measured logR{sub HK}{sup ′} value (−5.26), well below the basal level. From the star’s spectral energy distribution we obtain an extinction E(B − V) = 0.045 ± 0.025 mag and a distance d = 232 ± 8 pc. We detect at ≳4σ lines belonging to three different ionization states of carbon (C i, C ii, and C iv) and the Si iv doublet at ∼3σ. Using far-UV spectra of nearby early G-type stars of known age, we derive a C iv/C i flux ratio–age relation, from which we estimate WASP-13's age to be 5.1 ± 2.0 Gyr. We rescale the solar irradiance reference spectrum to match the flux of the C iv 1548 doublet. By integrating the rescaled solar spectrum, we obtain an XUV flux at 1 AU of 5.4 erg s{sup −1} cm{sup −2}. We use a detailed model of the planet’s upper atmosphere, deriving a mass-loss rate of 1.5 × 10{sup 11} g s{sup −1}. Despite the low logR{sub HK}{sup ′} value, the star shows a far-UV spectrum typical of middle-aged solar-type stars, pointing toward the presence of significant extrinsic absorption. The analysis of a high-resolution spectrum of the Ca ii H and K lines indicates that the ISM absorption could be the origin of the low logR{sub HK}{sup ′} value. Nevertheless, the large uncertainty in the Ca ii ISM abundance does not allow us to firmly exclude the presence of circumstellar gas.

79 ASTRONOMY AND ASTROPHYSICS↗

A Statistical Framework for Microbial Source Attribution: Measuring Uncertainty in Host Transmission Events Inferred from Genetic Data (Part 2 of a 2 Part Report)

This report explores the question of whether meaningful conclusions can be drawn regarding the transmission relationship between two microbial samples on the basis of differences observed between the two sample's respective genomes. Unlike similar forensic applications using human DNA, the rapid rate of microbial genome evolution combined with the dynamics of infectious disease require a shift in thinking on what it means for two samples to 'match' in support of a forensic hypothesis. Previous outbreaks for SARS-CoV, FMDV and HIV were examined to investigate the question of how microbial sequence data can be used to draw inferences that link two infected individuals by direct transmission. The results are counter intuitive with respect to human DNA forensic applications in that some genetic change rather than exact matching improve confidence in inferring direct transmission links, however, too much genetic change poses challenges, which can weaken confidence in inferred links. High rates of infection coupled with relatively weak selective pressure observed in the SARS-CoV and FMDV data lead to fairly low confidence for direct transmission links. Confidence values for forensic hypotheses increased when testing for the possibility that samples are separated by at most a few intermediate hosts. Moreover, the observed outbreak conditions support the potential to provide high confidence values for hypothesis that exclude direct transmission links. Transmission inferences are based on the total number of observed or inferred genetic changes separating two sequences rather than uniquely weighing the importance of any one genetic mismatch. Thus, inferences are surprisingly robust in the presence of sequencing errors provided the error rates are randomly distributed across all samples in the reference outbreak database and the novel sequence samples in question. When the number of observed nucleotide mutations are limited due to characteristics of the outbreak or the availability of only partial rather than whole genome sequencing, indel information was shown to have the potential to improve performance but only for select outbreak conditions. In examined HIV transmission cases, extended evolution proved to be the limiting factor in assigning high confidence to transmission links, however, the potential to correct for extended evolution not associated with transmission events is demonstrated. Outbreak specific conditions such as selective pressure (in the form of varying mutation rate), are shown to impact the strength of inference made and a Monte Carlo simulation tool is introduced, which is used to provide upper and lower bounds on the confidence values associated with a forensic hypothesis.

59 BASIC BIOLOGICAL SCIENCES↗

Algorithm to calculate off-plane magnetic field from an on-plane field map

An algorithm is presented to calculate the field components [B x (x,y,z), B y (x,y,z), B z (x,y,z)] of the magnetic field at a point (x,y,z) in space, from the knowledge of the components [B x (x,y = 0,z), B y (x,y = 0,z), B z (x,y = 0,z)] on a ”reference plane”, which is normal to the y-axis at y=0. The algorithm, which is a general one and is not restricted to fields with mid-plane symmetry is based on the Taylor series expansion of the magnetic field components at any point in space in terms of the distance (y) of the point from the reference plane. The coefficients of the Taylor series expansion are expressed in terms of the on-plane field components and their partial derivatives with respect to spatial coordinates (x,z). The field components are usually generated from magnetic field measurements on a rectangular grid on the plane. The required partial derivatives of the field components on the plane can be computed with two methods; numerically, or by fitting a polynomial function to the experimentally measured values of the field components and subsequently take the required partial derivatives of the polynomial function. Each of these two method which calculates the partial derivatives of the field components on the plane, is applied to calculate the off-plane field components of the magnetic field generated by a modified Halbach magnet [1] of inner radius of 4.4 cm and it is found that each method provides accurate results with a relative error <1% deviation from the ”ideal” fields if the y distance of the point from the reference plane is smaller than 2 cm. This algorithm is part of the RAYTRACE computer code [2] and has been applied [3] on a dipole magnet with median plane symmetry.

43 PARTICLE ACCELERATORS↗

Comparative Study of Clustering Techniques for Real-Time Dynamic Model Reduction

Dynamic model reduction in power systems is necessary for improving computational efficiency. Traditional model reduction using linearized models or offline analysis would not be adequate to capture power system dynamic behaviors, especially the new mix of intermittent generation and intelligent consumption makes the power system more dynamic and non-linear. Real time dynamic model reduction emerges as an important need. This paper explores the use of clustering techniques to analyze real-time phasor measurements to determine generator groups and representative generators for dynamic model reduction. Two clustering techniques – graph clustering and evolutionary clustering – are studied in this paper. Various implementations of these techniques are compared and also compared with a previously developed Singular Value Decomposition (SVD)-based dynamic model reduction approach. Various methods exhibit different levels of accuracy when comparing the reduced model simulation against the original model. But some of them are consistently accurate. From this comparative perspective, this paper provides a good reference point for practical implementations.

model reduction, graph clustering, svd, evolutiona↗

Wrinkles in the Froggatt-Nielsen mechanism and flavorful new physics

Abstract When the Froggatt-Nielsen mechanism is used to explain the Standard Model flavor hierarchy, new physics couplings are also determined by the horizontal symmetry. However, additional symmetries or dynamics in the UV can sometimes lead to a departure from this naïve scaling for the new physics couplings. We show that an effective way to keep track of these changes is by using the new spurions of the U(3) 5 global flavor symmetry, where we parameterize extra suppression or enhancement factors, referred to aswrinkles, using the same power counting parameter as in the original Froggatt-Nielsen model. As a concrete realization, we consider two flavor spurions of theS 1 leptoquark, and demonstrate that wrinkles can be used to make an enhanced value of$$ \textrm{BR}\left({B}^{+}\to {K}^{+}\nu \overline{\nu}\right) $$ BR B + → K + ν ν ¯ consistent with other flavor observables. We also present example UV models that realize wrinkles, and comment on choosing consistent charges in ordinary Froggatt-Nielsen models without the typical monotonicity condition.

Physics↗

A new chemical kinetic method of determining RON and MON values for single component and multicomponent mixtures of engine fuels

A new method of using chemical kinetic reaction modeling to predict the Research Octane Number (RON) and Motor Octane Number (MON) of single component fuels and fuel mixtures is described and illustrated via comparisons between computed and experimental values obtained using the well-established ASTM test procedures in a Cooperative Fuels Research (CFR) engine. Comparisons include predictions of RON and MON for a large variety of neat fuels, studies determining the RON and MON of mixtures of primary reference fuels (PRF) and toluene, and studies of RON and MON for mixtures of single-component and multiple-component gasoline surrogate mixtures with ethanol. Advantages in costs, time, and experimental complexity of the kinetic modeling approach compared to the existing engine test procedures are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical image analysis for graphene layer detection: Enhanced green channel methodology

Graphene, a material of increasing research interest, requires accurate layer identification due to its sensitivity to layer count. Existing methods for graphene layer number identification are either time-consuming or of low accuracy, with high-accuracy methods often requiring expensive processes. This paper aims to address this challenge by proposing a cost-effective and efficient approach. Specifically, the current work highlights only the green channel—one of the three primary color channels (red, green, blue) that make up an optical image—from images of exfoliated graphene flakes for layer count identification. A linear regression is performed between pixel position and substrate green channel value, and this effect is subtracted from the entire optical image to mitigate background effects. By storing the range of green channel values for each type of flake (monolayer, bilayer, or tri-layer) based on a few images, we establish thresholds for identifying different types of layers in a particular setup. Additionally, our methodology allows for flexible threshold tuning using a single reference image, enabling adjustment to changes in detection setup such as illumination level, magnification, or microscope used. Finally, demonstrating high accuracy and flexibility, this methodology presents a suitable technique for graphene layer number identification without the need for large datasets or expensive instruments.

2D materials↗

Nuclear Data Sheets for A = 195

Experimental structure and decay data for all nuclides with mass number A=195 (Re, Os, Ir, Pt, Au, Hg, Tl, Pb, Bi, Po, At, Rn) have been revised, updated, and incorporated into the ENSDF data file. All literature available by March 2014 has been considered. This evaluation supersedes the previous one for this mass chain (Zhou Chunmei, Nuclear Data Sheets 86, 645 (1999), 1999Zh11). The detailed level schemes, decay schemes, experimental reaction and decay data on which they are based are summarized and presented here. References, Jπ arguments, and comments are given in the text. No excited state data are yet available for {sup 195}Re and {sup 195}Rn. The adopted levels for {sup 195}At are firstly presented in this evaluation. In addition, Q values have been updated based on 2012Wa38.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First-Principles Approach to the Conductance of Covalently Bound Molecular Junctions

In this study, we develop a first-principles approach for accurate conductance calculations of covalently bound molecular junctions. Our approach extends the DFT+$Σ$ method, an approximate GW -based self-energy correction scheme acting on a tractable molecular subspace (based on a gas-phase reference of the same dimension) that corrects level alignment in the junction relative to density functional theory (DFT). We introduce a new extended gas-phase reference system, consisting of the molecule and several lead atoms, whose frontier orbitals maximally project onto the conducting orbitals of the junction. With this choice of reference, our self-energy correction to the Kohn–Sham Hamiltonian takes into account mixing of the gas-phase reference orbitals upon the formation of the junction. We apply our generalized DFT+$Σ$ approach to a series of alkane–chain junctions in which the molecules are covalently bound to the leads via carboxyl terminal groups. Our results lead to conductance values in quantitative agreement with experiment. We also revisit the well-studied Au–bipyridine–Au junction and show that we recover the original DFT+$Σ$ approach for relatively weak donor–acceptor molecule–lead binding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photodissociation cross sections of ClOOCl at 248.4 and 266 nm

This study utilized a mass-resolved detection of ClOOCl to determine its photodissociation cross section, which is the product of the absorption cross section and dissociation quantum yield. An effusive molecular beam of ClOOCl was generated and its photodissociation probability was determined through measuring the decrease in the ClOOCl beam intensity upon laser irradiation. By comparing with a reference molecule, the absolute cross sections of ClOOCl were obtained without knowing its absolute concentration. The determined cross section of ClOOCl at 248.4 nm is (8.85{+-}0.42)x10{sup -18} cm{sup 2} at 200 K, significantly larger than previously reported values. The temperature dependence of the cross section was investigated at 248.4 nm in the range of 160-260 K; only a very small and negative temperature effect was observed. Because 248.4 nm is very close to the peak of the UV absorption band of ClOOCl, this work provides a new calibration point for normalizing relative absorption spectra of ClOOCl. In this work, the photodissociation cross section at 266 nm and 200 K was also reported to be (4.13{+-}0.21)x10{sup -18} cm{sup 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rarefaction windows in a high-power impulse magnetron sputtering plasma

The velocity distribution function of the sputtered particles in the direction parallel to the planar magnetron cathode is studied by spatially- and time-resolved laser-induced fluorescence spectroscopy in a short-duration (20 μs) high-power impulse magnetron sputtering discharge. The experimental evidence for the neutral and ionized sputtered particles to have a constant (saturated) velocity at the end of the plasma on-time is demonstrated. The velocity component parallel to the target surface reaches the values of about 5 km/s for Ti atoms and ions, which is higher that the values typically measured in the direct current sputtering discharges before. The results point out on the presence of a strong gas rarefaction significantly reducing the sputtered particles energy dissipation during a certain time interval at the end of the plasma pulse, referred to as “rarefaction window” in this work. The obtained results agree with and essentially clarify the dynamics of HiPIMS discharge studied during the plasma off-time previously in the work: N. Britun, Appl. Phys. Lett. 99, 131504 (2011)

36 MATERIALS SCIENCE↗

Radiation assessment to paediatric with F-18-FDG undergo whole-body PET/CT examination

This study was carried out on wholebody radiation dose assessment to paediatrics patient who undergo PET/CT scanner at Institut Kanser Negara. Consist of 68 patients with varies of malignancies and epilepsy disease case covering age between 2 years to 12 years old. This is a retrospective study from 2010-2014. The use of PET/CT scanner as an advanced tool has been proven to give an extra radiation dose to the patient. It is because of the radiation exposure from the combination of both CT and PET scans rather than a single CT or PET scan. Furthermore, a study on radiation dose to paediatric patient undergoing PET/CT is rare in Malaysia. So, the aim of this study is to estimate the wholebody effective dose to paediatric patient in Malaysia. Effective dose from PET scan was calculated based on the activity of F18 FDG and dose coefficient reported in International Commission on Radiological Protection (ICRP) Publication 106. Effective dose from CT was determined using k coefficient as reported in ICRP publication 102 and Dose Length Product (DLP) value. The average effective dose from PET and CT were found to be 7.05mSv and 5.77mSv respectively. The mean wholebody effective dose received by a patient with combined PETCT examination was 12.78mSv. These results could be used as reference for dosimetry of a patient undergoing PETCT examination in Malaysia.

07 ISOTOPE AND RADIATION SOURCES↗

Method for improved voltage determination for pulsed power systems utilizing a magnetically insulated transmission line

Because the voltage is difficult to measure in a magnetically insulated transmission line (MITL), measurement of the currents flowing in the cathode and anode are often used with MITL theory to estimate the voltage in a given experiment. However, that estimate contains a space charge correction term whose magnitude depends on what is referred to as the g factor that describes the distribution of charge and current in the electron flow layer in the MITL. Typically, g is on the order of unity but the accuracy of the voltage estimate depends on its actual value. While the space charge correction term is small when the MITL flow is strongly insulated, it is particularly important near self-limited MITL flow. System parameters that affect the distribution of electron flow are studied here at self-limited flow in order to illustrate this matter and develop a methodology to improve the voltage determination.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of Monte Carlo collimator transport methods for photon treatment planning in radiotherapy

Purpose: The aim of this work was a Monte Carlo (MC) based investigation of the impact of different radiation transport methods in collimators of a linear accelerator on photon beam characteristics, dose distributions, and efficiency. Thereby it is investigated if it is possible to use different simplifications in the radiation transport for some clinical situations in order to save calculation time. Methods: Within the Swiss Monte Carlo Plan, a GUI-based framework for photon MC treatment planning, different MC methods are available for the radiation transport through the collimators [secondary jaws and multileaf collimator (MLC)]: EGSnrc (reference), VMC++, and Pin (an in-house developed MC code). Additional nonfull transport methods were implemented in order to provide different complexity levels for the MC simulation: Considering collimator attenuation only, considering Compton scatter only or just the firstCompton process, and considering the collimators as totally absorbing. Furthermore, either a simple or an exact geometry of the collimators can be selected for the absorbing or attenuation method. Phasespaces directly above and dose distributions in a water phantom are analyzed for academic and clinical treatment fields using 6 and 15 MV beams, including intensity modulated radiation therapy with dynamic MLC. Results: For all MC transport methods, differences in the radial mean energy and radial energy fluence are within 1% inside the geometric field. Below the collimators, the energy fluence is underestimated for nonfull MC transport methods ranging from 5% for Compton to 100% for Absorbing. Gamma analysis using EGSnrc calculated doses as reference shows that the percentage of voxels fulfilling a 1% /1 mm criterion is at least 98% when using VMC++, Compton, or firstCompton transport methods. When using the methods Pin, Transmission, Flat-Transmission, Flat-Absorbing or Absorbing, the mean value of points fulfilling this criterion over all tested cases is 97%, 88%, 74%, 68%, or 65%, respectively. However, compared to EGSnrc calculations, the gain in efficiency is a factor of up to 10 for VMC++ and up to 48 for the absorbing method. Conclusions: The results of this investigation suggest that it is an option to use a simple transport technique in the initial treatment planning process and use more accurate transport methods for the final dose calculation accepting longer calculation times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗