Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROOM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Drying shrinkage of alkali activated binders cured at room temperature

Alkali activated binders tend to exhibit higher drying shrinkage movements when compared with Portland cement. An experimental investigation was undertaken in order to assess the drying shrinkage of a basic alkali activated binder versus Portland cement, and to evaluate the effectiveness of different additives in reducing the drying shrinkage of the alkali activated binder. The results indicated that the drying shrinkage of the basic alkali activated binder was about twice that of Type I Portland cement. Some of the additives used to refine the alkali activated binder formulation were found to lower the drying shrinkage of the alkali activated binder to levels that were comparable with that of Portland cement. Explanations were presented for the mechanisms through which these additives enhance the dimensional stability of the alkali activated binder. SEM, TG/DTG and heat of hydration techniques were used to gain more insight into the mechanisms of action of different additives in alkali activated binders.

36 MATERIALS SCIENCE↗

Parabolic oxidation kinetics of a plutonium alloy at room temperature

Auger electron spectroscopy (AES) was used to characterize the oxide scale formed on an ~0.5 wt. % Ga plutonium metal alloy. Analysis of changes to the characteristic Auger transitions for Pu and O during sputter depth profiles were used in combination with previously measured sputter yields to determine the thickness of the oxide scale and provide insight into its chemistry. From this data, the parabolic kinetics for the Pu-Ga alloy were determined as a function of relative humidity, RH = 14–92%, and oxygen partial pressure, p(O 2 ) = 31–157 Torr, at 25°C. For each relative humidity investigated, the parabolic rate constant was found to be independent of oxygen partial pressure. Furthermore, power-law fits to the relative humidity effect on the rate constant was found to have a power of n = 1.265, indicating the diffusion species which rate-limits the reaction isn’t molecular water, which subsequent dissociates at the oxide-metal interface, or hydroxyl from dissociation at the gas-surface interface.

36 MATERIALS SCIENCE↗

A mesoscale crystal plasticity model to predict room-temperature deformation and martensitic transformation of high-strength Quenching and Partitioning (Q&P) Steels and validation with synchrotron X-ray diffraction

Renowned for the superior mechanical properties and adeptness at cold-forming, Quenching and Partitioning (QP) steels have gained prominence as a promising candidate material in fabricating safety-critical components in various industries. The pertinent research on QP steels focus on the martensitic transformation of the Retained Austenite (RA) phase during cold-forming, a crucial mechanism that substantially influences the overall strength and ductility of QP steels. The austenite stability and transformation rate heavily rely on the local strain path and the initial microstructure, which is challenging for analytical prediction. In this paper, a mesoscale model is developed to capture the deformation and transformation kinetics of QP steels inside the microstructure. The model integrates the detailed explicit microstructure, acquired from characterization experiments, into a high-resolution finite element (FE) mesh. It distinctly model the deformation and interaction between the various phases and the effect on the transformation of RA. The model is validated with high energy X-ray diffraction (HEXRD) data, and shows excellent capability in predicting the asymmetric stress-strain behavior under uniaxial tension and compression, as well as the martensitic transformation rate. The model is used to investigate the strain and load partitioning effect of surrounding matrix to the transformation of RA, offering insights into the complex behavior of QP980 and facilitates further material development.

36 MATERIALS SCIENCE↗

Greater Postimplant Swelling in Small-Volume Prostate Glands: Implications for Dosimetry, Treatment Planning, and Operating Room Technique

Purpose: Postimplant prostatic edema has been implicated in suboptimal permanent implants, and smaller prostates have been reported to have worse dosimetric coverage. In this study we compare the degree of postimplant edema between larger and smaller prostates and examine the effects of prostate size on the dose delivered to 90% of the prostate (D90). Methods and Materials: From September 2003 to February 2006, 105 hormone-naive patients underwent permanent prostate brachytherapy with {sup 125}I Rapid Strand (Oncura Inc., Arlington Heights, IL). All patients underwent pelvic magnetic resonance imaging (MRI) within 3 weeks before implant, transrectal ultrasound at the time of implant, and both computed tomography and MRI 2.5 to 3 weeks after implant. Prostates were divided into 5 subgroups based on preimplant MRI volumes: less than 25 mL, 25 to 35 mL, 35 to 45 mL, 45 to 55 mL, and greater than 55 mL. Prostate swelling was assessed by use of preimplant and postimplant MRI volumes. Postimplant dosimetry was determined by MRI and compared between the subgroups. Results: All prostates showed postimplant swelling on MRI when compared with preimplant MRI, with a mean increase of 31% {+-} 31% (p < 0.0001). The greatest swelling was noted in small prostates (volume less than 25 mL), with a mean increase of 70% {+-} 36%. The degree of swelling in the group with a volume less than 25 mL was significantly larger than the degree of swelling in all other prostate subgroups (p < 0.003). Transrectal ultrasound significantly overestimates the prostate volume when compared with MRI by a mean of 15% {+-} 25% (p = 0.0006) and is more pronounced for smaller prostates. Although prostates with volumes less than 25 mL did not have significantly worse D90 compared with larger prostates, they had the largest percent of suboptimal implants by the standard ratio of D90 divided by the prescription dose. Conclusions: Although small prostates have the greatest postimplant edema, planning ultrasound at the time of implant overestimates the volumes of smaller prostates to a greater degree than larger prostates, which may minimize the effects of edema on postimplant dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Guidance During Head-and-Neck Cancer Radiation Therapy: Analysis of Alignment Trends With In-Room Cone-Beam Computed Tomography Scans

Purpose: On-board cone-beam computed tomography (CBCT) is currently available for alignment of patients with head-and-neck cancer before radiotherapy. However, daily CBCT is time intensive and increases the overall radiation dose. We assessed the feasibility of using the average couch shifts from the first several CBCTs to estimate and correct for the presumed systematic setup error. Methods and Materials: 56 patients with head-and-neck cancer who received daily CBCT before intensity-modulated radiation therapy had recorded shift values in the medial-lateral, superior-inferior, and anterior-posterior dimensions. The average displacements in each direction were calculated for each patient based on the first five or 10 CBCT shifts and were presumed to represent the systematic setup error. The residual error after this correction was determined by subtracting the calculated shifts from the shifts obtained using daily CBCT. Results: The magnitude of the average daily residual three-dimensional (3D) error was 4.8 {+-} 1.4 mm, 3.9 {+-} 1.3 mm, and 3.7 {+-} 1.1 mm for uncorrected, five CBCT corrected, and 10 CBCT corrected protocols, respectively. With no image guidance, 40.8% of fractions would have been >5 mm off target. Using the first five CBCT shifts to correct subsequent fractions, this percentage decreased to 19.0% of all fractions delivered and decreased the percentage of patients with average daily 3D errors >5 mm from 35.7% to 14.3% vs. no image guidance. Using an average of the first 10 CBCT shifts did not significantly improve this outcome. Conclusions: Using the first five CBCT shift measurements as an estimation of the systematic setup error improves daily setup accuracy for a subset of patients with head-and-neck cancer receiving intensity-modulated radiation therapy and primarily benefited those with large 3D correction vectors (>5 mm). Daily CBCT is still necessary until methods are developed that more accurately determine which patients may benefit from alternative imaging strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗