Note: A microfluidic freezer based on evaporative cooling of atomized aqueous microdroplets

We report for the first time water-based evaporative cooling integrated into a microfluidic chip for temperature control and freezing of biological solution. We opt for water as a nontoxic, effective refrigerant. Aqueous solutions are atomized in our device and evaporation of microdroplets under vacuum removes heat effectively. We achieve rapid cooling (−5.1 °C/s) and a low freezing temperature (−14.1 °C). Using this approach, we demonstrate freezing of deionized water and protein solution. Our simple, yet effective cooling device may improve many microfluidic applications currently relying on external power-hungry instruments for cooling and freezing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetocaloric properties of rapidly solidified Dy{sub 3}Co alloy ribbons

The magnetic and magnetocaloric (MC) properties of melt-spun ribbons of the Dy{sub 3}Co intermetallic compound were investigated. Samples were fabricated in an Ar environment using a homemade melt spinner system at a linear speed of the rotating copper wheel of 40 ms{sup −1}. X-ray diffraction analysis shows that ribbons crystallize into a single-phase with the Fe{sub 3}C-type orthorhombic crystal structure. The M(T) curve measured at 5 mT reveals the occurrence of a transition at 32 K from a first to a second antiferromagnetic (AFM) state and an AFM-to-paramagnetic transition at T{sub N} = 43 K. Furthermore, a metamagnetic transition is observed below T{sub N}, but the magnetization change ΔM is well below the one reported for bulk alloys. Below 12 K, large inverse MC effect and hysteresis losses are observed. This behavior is related to the metamagnetic transition. For a magnetic field change of 5 T (2 T) applied along the ribbon length, the produced ribbons show a peak value of the magnetic entropy change ΔS{sub M}{sup peak} of −6.5 (− 2.1) Jkg{sup −1}K{sup −1} occurring close to T{sub N} with a full-width at half-maximum δT{sub FWHM} of 53 (37) K, and refrigerant capacity RC = 364 (83) Jkg{sup −1} (estimated from the product |ΔS{sub M}{sup peak}| × δT{sub FWHM})

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Studies of scintillation properties of CaMoO{sub 4} at millikelvin temperatures

Application of CaMoO{sub 4} as a scintillation target in cryogenic rare event searches relies on the understanding of scintillation properties of the material at the temperatures at which these detectors operate. We devised and implemented a detection module with a low-temperature photomultiplier from Hamamatsu (model R8520-06) powered by a Cockcroft-Walton generator. The detector module containing the CaMoO{sub 4} crystal was placed in a {sup 3}He/{sup 4}He dilution refrigerator and used to measure scintillation characteristics of CaMoO{sub 4} in the millikelvin temperature range. At the lowest temperature achieved, the energy resolution of CaMoO{sub 4} for 122 keV γ from a {sup 57}Co source is found to be 30%, and the fast and slow decay constants are 40.6 ± 0.8 μs and 3410 ± 50 μs, respectively. The temperature variation of the CaMoO{sub 4} decay kinetics is discussed in terms of a three-level model of the emission center.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced electrocaloric effect in displacive-type organic ferroelectrics

We explore the intrinsic feature of electrocaloric effect (ECE) accompanied by ferroelectric (FE)-paraelectric (PE) transition for displacive-type organic ferroelectrics using Green's function theory. It is demonstrated that decreasing elastic constant K or increasing spin-lattice coupling λ can enhance the ECE, as well as polarization P and transition temperature T{sub C}. Indeed, one expects that the optimal operating temperature for solid-state refrigeration is around room temperature, at which the ECE achieves its maximum. As T{sub C} is tuned to ∼310 K, it presents larger ECE response and remanent polarization with lower coercive field for smaller K value, suggesting that well flexible displacive-type organic ferroelectrics are excellent candidates both for electric cooling and data storage in the design of nonvolatile FE random-access memories. Furthermore, in an electric field, it provides a bridge between a Widom line that denotes FE-PE crossover above T{sub C} and a metaelectric transition line below T{sub C} that demonstrates an FE switching behavior with an antiparallel field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact AC susceptometer for fast sample characterization down to 0.1 K

We report a new design of an AC magnetic susceptometer compatible with the Physical Properties Measurement System (PPMS) by Quantum Design, as well as with its adiabatic demagnetization refrigerator option. With the elaborate compact design, the susceptometer allows simple and quick sample mounting process. The high performance of the susceptometer down to 0.1 K is demonstrated using several superconducting and magnetic materials. This susceptometer provides a method to quickly investigate qualities of a large number of samples in the wide temperature range between 0.1 and 300 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Table-like magnetocaloric effect in Gd{sub 56}Ni{sub 15}Al{sub 27}Zr{sub 2} alloy and its field independence feature

In order to obtain “table-like” magnetocaloric effect (MCE), multiple-phase Gd{sub 56}Ni{sub 15}Al{sub 27}Zr{sub 2} alloy was prepared by arc-melting followed by suck-casting method. Powder x-ray diffraction and calorimetric measurements reveal that the sample contains both glassy and crystalline phases. The fraction of the glassy phase is about 62%, estimated from the heat enthalpy of the crystallization. The crystalline phases, Gd{sub 2}Al and GdNiAl further broadened the relatively wider magnetic entropy change (−ΔS{sub M}) peak of the amorphous phase, which resulted in the table-like MCE over a maximum temperature range of 52.5 K to 77.5 K. The plateau feature of the MCE was found to be nearly independent of the applied magnetic field from 3 T to 5 T. The maximum −ΔS{sub M} value of the MCE platforms is 6.0 J/kg K under applied magnetic field change of 5 T. Below 3 T, the field independence of the table-like feature disappears. The relatively large constant values of −ΔS{sub M} for the respective applied magnetic fields have promising applications in magnetic refrigeration using regenerative Ericsson cycle.

36 MATERIALS SCIENCE↗

Note: Cryogenic heat switch with stepper motor actuator

A mechanical cryogenic heat switch has been developed using a commercially available stepper motor and control electronics. The motor requires 4 leads, each carrying a maximum, pulsed current of 0.5 A. With slight modifications of the stepper motor, the switch functions reliably in vacuum at temperatures between 300 K and 4 K. The switch generates a clamping force of 262 N at room temperature. At 4 K it achieves an “on state” thermal conductance of 5.04 mW/K and no conductance in the “off state.” The switch is optimized for cycling an adiabatic demagnetization refrigerator.

42 ENGINEERING↗

Giant low-field magnetocaloric effect in single-crystalline EuTi{sub 0.85}Nb{sub 0.15}O{sub 3}

The magnetocaloric effect in ferromagnetic single crystal EuTi{sub 0.85}Nb{sub 0.15}O{sub 3} has been investigated using magnetization and heat capacity measurements. EuTi{sub 0.85}Nb{sub 0.15}O{sub 3} undergoes a continuous ferromagnetic phase transition at T{sub C} = 9.5 K due to the long range ordering of magnetic moments of Eu{sup 2+} (4f{sup 7}). With the application of magnetic field, the spin entropy is strongly suppressed and a giant magnetic entropy change is observed near T{sub C}. The values of entropy change ΔS{sub m} and adiabatic temperature change ΔT{sub ad} are as high as 51.3 J kg{sup −1} K{sup −1} and 22 K, respectively, for a field change of 0–9 T. The corresponding magnetic heating/cooling capacity is 700 J kg{sup −1}. This compound also shows large magnetocaloric effect even at low magnetic fields. In particular, the values of ΔS{sub m} reach 14.7 and 23.8 J kg{sup −1} K{sup −1} for field changes of 0–1 T and 0–2 T, respectively. The low-field giant magnetocaloric effect, together with the absence of thermal and field hysteresis makes EuTi{sub 0.85}Nb{sub 0.15}O{sub 3} a very promising candidate for low temperature magnetic refrigeration.

36 MATERIALS SCIENCE↗

Magnetic and magnetocaloric properties of quasi-one-dimensional Ising spin chain CoV{sub 2}O{sub 6}

We have investigated the magnetic and magnetocaloric properties of antiferromagnetic Ising spin chain CoV{sub 2}O{sub 6} by magnetization and heat capacity measurements. Both monoclinic α-CoV{sub 2}O{sub 6} and triclinic γ-CoV{sub 2}O{sub 6} exhibit field-induced metamagnetic transitions from antiferromagnetic to ferromagnetic state via an intermediate ferrimagnetic state with 1/3 magnetization plateau. Due to the field-induced metamagnetic transitions, these systems show large conventional as well as inverse magnetocaloric effects. In α-CoV{sub 2}O{sub 6}, we observe field-induced complex magnetic phases and multiple magnetization plateaus below 6 K when the field is applied along c axis. Several critical temperatures and fields have been identified from the temperature and field dependence of magnetization, magnetic entropy change, and heat capacity to construct the H–T phase diagram. As compared to α-CoV{sub 2}O{sub 6}, γ-CoV{sub 2}O{sub 6} displays a relatively simple magnetic phase diagram. Due to the large magnetic entropy change and adiabatic temperature change at low or moderate applied magnetic field, γ-CoV{sub 2}O{sub 6} may be considered as a magnetic refrigerant in the low-temperature region below 20 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Construction and experimental validation of a simple, compact, resealable, and reliable Vycor{sup ®} superleak assembly for use at low temperatures

A new method of constructing a superleak assembly for use in experiments involving {sup 4}He or {sup 3}He-{sup 4}He mixtures at very low temperatures is described. Superleaks are made of a porous medium with very small pores and channels. Superleaks are often incorporated in thermomechanical pumps, superfluid magnetic pumps, dilution refrigerators, and superfluid helium transfer systems. We used several cylindrical pieces of Vycor, a permeable glass with average pore diameter of 40 Å and porosity of 28%, as a candidate to be used in our superleak assembly. Our design is simple and compact. Our superleak assembly can be disassembled and easily reassembled for reuse. We successfully tested and validated this device at temperatures between 1.4 K and 2.7 K. We experienced no superfluid leaks into the surrounding vacuum. We also report that thermal cycling caused no performance degradation. It is our goal to share the design and construction techniques of this new superleak assembly.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Natural convective heat transfer from square cylinder

This article is concerned with natural convective heat transfer from square cylinder mounted on a plane adiabatic base, the cylinders having an exposed cylinder surface according to different horizontal angle. The cylinder receives heat from a radiating heater which results in a buoyant flow. There are many industrial applications, including refrigeration, ventilation and the cooling of electrical components, for which the present study may be applicable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A uniaxial stress capacitive dilatometer for high-resolution thermal expansion and magnetostriction under multiextreme conditions

Thermal expansion and magnetostriction are directional dependent thermodynamic quantities. For the characterization of novel quantum phases of matter, it is required to study materials under multi-extreme conditions, in particular, down to very low temperatures, in very high magnetic fields or under high pressure. We developed a miniaturized capacitive dilatometer suitable for temperatures down to 20 mK and usage in high magnetic fields, which exerts a large spring force between 40 to 75 N on the sample. This corresponds to a uniaxial stress up to 3 kbar for a sample with cross section of (0.5 mm){sup 2}. We describe design and performance test of the dilatometer which resolves length changes with high resolution of 0.02 Å at low temperatures. The miniaturized device can be utilized in any standard cryostat, including dilution refrigerators or the commercial physical property measurement system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancement in magnetocaloric properties of holmium chromite by gadolinium substitution

HoCrO{sub 3}, Ho{sub 0.67}Gd{sub 0.33}CrO{sub 3}, and GdCrO{sub 3} bulk powder samples were prepared by citrate route. The phase purity and the structural properties of the samples were examined by x-ray diffraction and Raman spectroscopic measurements. The dc magnetization data revealed that the Cr{sup 3+} ordering temperatures (Néel temperature) for the HoCrO{sub 3}, Ho{sub 0.67}Gd{sub 0.33}CrO{sub 3}, and GdCrO{sub 3} samples are 140 K, 148 K, and 167 K, respectively, while the ac magnetization data revealed that the rare-earth (Ho) ordering occurs at ∼8 K for HoCrO{sub 3} and Ho{sub 0.67}Gd{sub 0.33}CrO{sub 3} samples. Temperature-induced magnetization reversal and spin reorientation were observed in GdCrO{sub 3} bulk sample, which depends on applied magnetic field and disappears at ∼1500 Oe and 500 Oe, respectively. By fitting the dc magnetic data with Curie-Weiss law, the effective magnetic moments were calculated to be 11.66 μ{sub B}, 10.23 μ{sub B}, and 9.90 μ{sub B} for the HoCrO{sub 3}, Ho{sub 0.67}Gd{sub 0.33}CrO{sub 3}, and GdCrO{sub 3} samples, respectively. The isothermal magnetization data showed that the magnetic behavior changed from canted antiferromagnetic in low temperature region (below Néel temperature) to paramagnetic at high temperature. It was found that Gd substitution considerably improves the magnetocaloric effect of HoCrO{sub 3}. Pure GdCrO{sub 3} bulk sample showed giant magnetocaloric entropy change (31.6 J/kg K at temperature ∼5 K and at ∼70 kOe), which is higher than that for polycrystalline RMnO{sub 3}, RCrO{sub 3}, and RFeO{sub 3} bulk powder samples. This renders GdCrO{sub 3} useful for potential applications in low-temperature magnetic refrigeration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of beam emission spectroscopy for turbulence transport study in Heliotron J

This paper describes the development study of the beam emission spectroscopy (BES) for the turbulent transport study in Heliotron J. Modification of the sightlines (10 × 4 for edge and 10 × 2 for edge) enables us to obtain 2-dimensional BES imaging. The cooling effect on the reduction in the electrical noise of avalanche photodiode (APD) assembly has been investigated using a refrigerant cooling system. When the temperature of the APD element has set to be −20 °C, the electrical noise can be reduced more than 50%. The measurement error of the phase difference in the case of low signal level has been tested by two light-emitting diode lamps. The APD cooling has an effect to improve the measurement error at the low signal level of APD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetocaloric effect near room temperature in quintenary and sextenary Heusler alloys

An inverse magnetocaloric effect is studied in Ni 2 Mn 1+x X 1-x -type Heusler alloys. Principally known for their shape-memory properties, these alloys also exhibit significant entropy and temperature changes (ΔS and ΔT Ad , respectively) under adiabatic conditions when a modest magnetic field is applied. We investigated the impact on magnetocaloric properties of introducing substantial chemical disorder on the X-site (X=Si,Ga,In), of replacing Ni with nonmagnetic Ag, and of replacing a small amount of Mn with Gd. While a reduction in ΔS is observed in the first two cases, we observe a significant enhancement of ΔS when a small amount of Gd is substituted for Mn. A thermodynamic analysis was conducted using magnetization and heat capacity data to estimate adiabatic temperature changes in the range of ΔT Ad ≃ -1 to -3 K for a 5 T magnetic field. Several alloys characterized in this study exhibit these respectable ΔT Ad values near room temperature, making them potentially viable candidates for magnetic refrigeration applications.

36 MATERIALS SCIENCE↗

Controlling the dopant profile for SRH suppression at low current densities in λ ≈ 1330 nm GaInAsP light-emitting diodes

The quantum efficiency of double hetero-junction light-emitting diodes (LEDs) can be significantly enhanced at low current density by tailoring the spatial profile of dopants to suppress Shockley–Read–Hall recombination. To demonstrate this effect, we model, design, grow, fabricate, and test a GaInAsP LED (λ≈ 1330 nm) with an unconventional dopant profile. Compared against that of our control design, which is a conventional n + -n - p + double hetero-junction LED, the dopant profile near the n - p + hetero-structure of the design displaces the built-in electric field in such a way that the J 02 space charge recombination current is suppressed. The design principle generalizes to other material systems and could be applicable to efforts to observe and exploit electro-luminescent refrigeration at practical power densities.

42 ENGINEERING↗

Adaptive four-level modeling of laser cooling of solids

Laser cooling of rare-earth doped solids has been demonstrated across a wide range of material platforms, inspiring the development of simple phenomenological models such as the four-level model to elucidate the universal properties of laser cooling under various operating conditions. However, these models usually require the input of full absorption spectra that must be provided experimentally or by additional complicated atomic modeling. In this Letter, we propose that a four-level model, when extended to admit effective energy levels adaptive to the pumping photon energy, can accurately predict the cooling efficiency as a function of temperature and pumping frequency using only few inputs such as the absorption coefficient measured at a single frequency and temperature. Our model exploits the quasi-equilibrium properties of the excitation of rare-earth ions for the determination of the effective four energy levels. The model is validated against published experimental results for a span of materials including ytterbium/thulium-doped glass and crystals. With the verified model, we derive explicit expressions for the optimal frequency and the operating bandwidth of pumping lasers. Our model significantly simplifies the modeling process of laser cooling and is expected to stimulate further development of optical refrigeration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal deflection in neutron scattering sample environments at Oak Ridge National Laboratory

The neutron sources at Oak Ridge National Laboratory use a wide suite of sample environment equipment to deliver extreme conditions for a number of experiments. Much of this instrumentation focuses on extremes of temperature, such as cryostats, closed-cycle refrigerators in both low and high temperature configurations, and radiant heating furnaces. When the temperature is controlled across a large range, thermal deflection effects can notably move the sample and affect its alignment in the beam. Here, we combine these sample environments with neutron imaging and machine vision to determine the motion of a representative sample with respect to the neutron beam. We find vertical sample displacement on the order of 1–2 mm and horizontal displacement that varies from near-negligible to 1.2 mm. While these deflections are not relevant for some of the beamlines at the first target station at the spallation neutron source and the high flux isotope reactor, they will become critical for upcoming instrumentation at the second target station, as well as any instruments targeting sub-mm samples, as neutron sources and optics evolve to smaller and more focused beams. We discuss mitigation protocols and potential modifications to the environment to minimize the effect of misalignment due to thermal deflection.

47 OTHER INSTRUMENTATION↗