Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Main challenges for ITER optical diagnostics

The review is made of the problems of ITER optical diagnostics. Most of these problems will be related to the intensive neutron radiation from hot plasma. At a high level of radiation loads the most types of materials gradually change their properties. This effect is most critical for optical diagnostics because of degradation of optical glasses and mirrors. The degradation of mirrors, that collect the light from plasma, basically will be induced by impurity deposition and (or) sputtering by charge exchange atoms. Main attention is paid to the search of glasses for vacuum windows and achromatic lens which are stable under ITER irradiation conditions. The last results of irradiation tests in nuclear reactor of candidate silica glasses KU-1, KS-4V and TF 200 are presented. An additional problem is discussed that deals with the stray light produced by multiple reflections from the first wall of the intense light emitted in the divertor plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vavilov–Cherenkov radiation when cosmic rays pass through the relic photon gas and when fast charged particles traverse an optical laser beam

Using a new [9, 10] quantum theory of Vavilov–Cherenkov radiation (VCR) based on Abraham’s theory, we show that a threshold VCR effect can be excited by the relic photon gas when relativistic charged cosmic-ray particles with γ ≥ γ{sub th} ≈ 1.9 × 10{sup 10} (where γ{sup –2} = 1–v{sup 2}/c{sup 2}, v is the particle speed, and c is the speed of light in a vacuum) pass through it. This is compatible with the well-known GZK cutoff [7, 8] at γ ≈ 10{sup 11}. We have obtained the condition γ > γ{sub th} ≈ 2.1 × 10{sup 2} for the appearance of VCR when a sufficiently fast charged particle (an electron, a proton, or a nucleus) passes through intense laser radiation. This condition ensures that VCR can be observed experimentally (e.g., on the Large Hadron Collider) without invoking any additional conditions required from the currently existing estimate of γth > 8.8 × 10{sup 4} [13] based on the now universally accepted quantum theory of VCR, which follows from Minkowski’s theory (and which gives an estimate of γ > 10{sup 21} when excited by the relic photon gas).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Prediction of Noise Due to Jet Turbulence Convecting Past Flight Vehicle Trailing Edges

High intensity acoustic radiation occurs when turbulence convects past airframe trailing edges. A mathematical model is developed to predict this acoustic radiation. The model is dependent on the local flow and turbulent statistics above the trailing edge of the flight vehicle airframe. These quantities are dependent on the jet and flight vehicle Mach numbers and jet temperature. A term in the model approximates the turbulent statistics of single-stream heated jet flows and is developed based upon measurement. The developed model is valid for a wide range of jet Mach numbers, jet temperature ratios, and flight vehicle Mach numbers. The model predicts traditional trailing edge noise if the jet is not interacting with the airframe. Predictions of mean-flow quantities and the cross-spectrum of static pressure near the airframe trailing edge are compared with measurement. Finally, predictions of acoustic intensity are compared with measurement and the model is shown to accurately capture the phenomenon.

Miller, Steven A. E.↗

Magnetic properties of square Py nanowires: Irradiation dose and geometry dependence

Arrays of ferromagnetic patterned nanostructures with single particle lateral dimensions between 160 nm and 400 nm were created by electron-beam lithography. The fourfold particles with rectangular-shaped walls around a square open area were produced from permalloy. Their magnetic properties were measured using the longitudinal magneto-optical Kerr effect. The article reports about the angle-dependent coercive fields and the influence of the e-beam radiation dose on sample shapes. It is shown that a broad range of radiation dose intensities enables reliable creation of nanostructures with parameters relevant for the desired magnetization reversal scenario. The experimental results are finally compared with micromagnetic simulations to explain the findings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nuclear DNA damage-triggered NLRP3 inflammasome activation promotes UVB-induced inflammatory responses in human keratinocytes

Ultraviolet (UV) radiation in sunlight can result in DNA damage and an inflammatory reaction of the skin commonly known as sunburn, which in turn can lead to cutaneous tissue disorders. However, little has been known about how UV-induced DNA damage mediates the release of inflammatory mediators from keratinocytes. Here, we show that UVB radiation intensity-dependently increases NLRP3 gene expression and IL-1β production in human keratinocytes. Knockdown of NLRP3 with siRNA suppresses UVB-induced production of not only IL-1β, but also other inflammatory mediators, including IL-1α, IL-6, TNF-α, and PGE{sub 2}. In addition, inhibition of DNA damage repair by knockdown of XPA, which is a major component of the nucleotide excision repair system, causes accumulation of cyclobutane pyrimidine dimer (CPD) and activation of NLRP3 inflammasome. In vivo immunofluorescence analysis confirmed that NLRP3 expression is also elevated in UV-irradiated human epidermis. Overall, our findings indicate that UVB-induced DNA damage initiates NLRP3 inflammasome activation, leading to release of various inflammatory mediators from human keratinocytes. - Highlights: • UVB radiation induces NLRP3 inflammasome activation in human keratinocytes. • NLRP3 knockdown suppresses production of UVB-induced inflammatory mediators. • UVB-induced DNA damage triggers NLRP3 inflammasome activation. • NLRP3 expression in human epidermis is elevated in response to UV radiation.

60 APPLIED LIFE SCIENCES↗

Variance Reduction within Implicit Monte Carlo Thermal Radiation Transport using the Local Importance Function Transform [Slides]

System of equations derived by Fleck and Cummings to model time-dependent thermal radiative transfer (TRT) problems: Solution of radiation specific intensity (I), non-linearly coupled to material internal energy (U); Absorption and re-emission approximated by effective scattering events. Useful for high-energy density physics simulations: i.e., astrophysics, inertial confinement fusion (ICF). Whereas deterministic methods are fully discretized and free of statistical noise, Monte Carlo methods allow for dynamic sampling of the phase space at the price of statistical noise; Monte Carlo methods are also characterized by a slow $\frac{1}{√Ν}$ convergence rate.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local Control and Toxicity in a Large Cohort of Central Lung Tumors Treated With Stereotactic Body Radiation Therapy

Purpose: Stereotactic body radiation therapy (SBRT) in central lung tumors has been associated with higher rates of severe toxicity. We sought to evaluate toxicity and local control in a large cohort and to identify predictive dosimetric parameters. Methods and Materials: We identified patients who received SBRT for central tumors according to either of 2 definitions. Local failure (LF) was estimated using a competing risks model, and multivariate analysis (MVA) was used to assess factors associated with LF. We reviewed patient toxicity and applied Cox proportional hazard analysis and log-rank tests to assess whether dose-volume metrics of normal structures correlated with pulmonary toxicity. Results: One hundred twenty-five patients received SBRT for non-small cell lung cancer (n=103) or metastatic lesions (n=22), using intensity modulated radiation therapy. The most common dose was 45 Gy in 5 fractions. Median follow-up was 17.4 months. Incidence of toxicity ≥ grade 3 was 8.0%, including 5.6% pulmonary toxicity. Sixteen patients (12.8%) experienced esophageal toxicity ≥ grade 2, including 50% of patients in whom PTV overlapped the esophagus. There were 2 treatment-related deaths. Among patients receiving biologically effective dose (BED) ≥80 Gy (n=108), 2-year LF was 21%. On MVA, gross tumor volume (GTV) was significantly associated with LF. None of the studied dose-volume metrics of the lungs, heart, proximal bronchial tree (PBT), or 2 cm expansion of the PBT (“no-fly-zone” [NFZ]) correlated with pulmonary toxicity ≥grade 2. There were no differences in pulmonary toxicity between central tumors located inside the NFZ and those outside the NFZ but with planning target volume (PTV) intersecting the mediastinum. Conclusions: Using moderate doses, SBRT for central lung tumors achieves acceptable local control with low rates of severe toxicity. Dosimetric analysis showed no significant correlation between dose to the lungs, heart, or NFZ and severe pulmonary toxicity. Esophageal toxicity may be an underappreciated risk, particularly when PTV overlaps the esophagus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the performance of in vivo portal dosimetry in detecting four types of treatment parameter variations

Purpose: To quantify the ability of electronic portal imaging device (EPID) dosimetry used during treatment (in vivo) in detecting variations that can occur in the course of patient treatment. Methods: Images of transmitted radiation from in vivo EPID measurements were converted to a 2D planar dose at isocenter and compared to the treatment planning dose using a prototype software system. Using the treatment planning system (TPS), four different types of variability were modeled: overall dose scaling, shifting the positions of the multileaf collimator (MLC) leaves, shifting of the patient position, and changes in the patient body contour. The gamma pass rate was calculated for the modified and unmodified plans and used to construct a receiver operator characteristic (ROC) curve to assess the detectability of the different parameter variations. The detectability is given by the area under the ROC curve (AUC). The TPS was also used to calculate the impact of the variations on the target dose–volume histogram. Results: Nine intensity modulation radiation therapy plans were measured for four different anatomical sites consisting of 70 separate fields. Results show that in vivo EPID dosimetry was most sensitive to variations in the machine output, AUC = 0.70 − 0.94, changes in patient body habitus, AUC = 0.67 − 0.88, and systematic shifts in the MLC bank positions, AUC = 0.59 − 0.82. These deviations are expected to have a relatively small clinical impact [planning target volume (PTV) D{sub 99} change <7%]. Larger variations have even higher detectability. Displacements in the patient’s position and random variations in MLC leaf positions were not readily detectable, AUC < 0.64. The D{sub 99} of the PTV changed by up to 57% for the patient position shifts considered here. Conclusions: In vivo EPID dosimetry is able to detect relatively small variations in overall dose, systematic shifts of the MLC’s, and changes in the patient habitus. Shifts in the patient’s position which can introduce large changes in the target dose coverage were not readily detected.

60 APPLIED LIFE SCIENCES↗

Laser formation of luminescence bubble microstructures in polymer films

The results of laser-induced formation of luminescent structures on the surface of poly-2.2’-n-oxydiphenylene-5.5’-bis-benzimidazole films, obtained by the coating method from a formic acid solution, are presented. The structures are formed using cw 405-nm laser radiation with intensities of 10{sup 2} – 10{sup 4} W cm{sup –2}. It is shown (using methods of optical, atomic-force, and electron microscopy) that the structures formed on the surface are microbubble foam-like aggregations. Their formation is modelled as a sequence of the following processes: release of formic acid molecules, their condensation on matrix defects in the surface layer, and explosive boiling as a result of heating this layer of polymer film by the laser beam. The luminescence of these structures is due to the weakening of the concentration quenching from closely spaced luminescence centres in benzimidazole cycles during their emergence to the surface and the increase in the distance between them due to the extension on bubble aggregates on the surface. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A feasibility study of using advanced external beam techniques to create a vaginal cuff brachytherapy-like endometrial boost plan

The purpose of this study was to explore the feasibility of using advanced external beam radiation therapy (EBRT) planning techniques for creating plans that could be used as a possible alternative for high-dose rate (HDR) vaginal cuff brachytherapy (VCBT) boost in treating endometrial cancer. The computed tomography (CT) images of a total of 4 female patients who had endometrial cancer treated with HDR-VCBT were selected for this study. A typical HDR-VCBT target volume, 0.5-cm-thick shell volume around the cylinder applicator in the prescribed treatment length was contoured and used as the planning target volume (PTV) in both the HDR VCBT and the EBRT VCBT-like plans. HDR-VCBT plans were made based on the clinical protocol, 6 Gy given at the cylinder surface. The EBRT plans were generated using either a 7-field intensity-modulated radiation therapy (IMRT) or a 2-arc volumetric-modulated arc therapy (VMAT) techniques for different cylinder sizes and treatment lengths, with the prescription dose of 5 Gy. Organs at risk (OARs) such as bladder, femoral heads, rectum, and sigmoid were also contoured and used in dosimetric evaluations. Dose-to-target metrics included mean dose, the dose covering 90% of target volume (D90) and the percentage of target volume covered by 90% of prescription dose (V90 or V13.5 Gy). Dose to OAR metrics included the maximum dose received by 0.1 cc (D0.1cc), 1.0 cc (D1.0cc), and 2.0 cc (D2.0cc) of OARs. These metrics were calculated and compared between all techniques. After the EBRT plans were normalized to achieve a comparable mean dose to target as HDR-VCBT, the EBRT plans were found to have superior target coverage and increased dose homogeneity compared with HDR-VCBT. V90s of EBRT plans were 95%, compared with 50% to 58% of the HDR plans. However, D0.1cc, D1.0cc, and D2.0cc of OARs were 2% to 38% lower in HDR-VCBT than in EBRT. Although HDR-VCBT plans demonstrated superior normal tissue sparing, both EBRT and HDR-VCBT plans produce plans that met clinical dose constraints on normal tissues. Advanced EBRT techniques such as IMRT and VMAT are capable of making plans, which closely resemble HDR-VCBT. Although the doses of OARs are greater in EBRT than in HDR-VCBT, the prescription dose coverage and dose homogeneity of the EBRT plans are greater than that of HDR-VCBT plans at the similar mean dose, and the OAR dose is still acceptable with EBRT plans. The detailed dosimetric approaches are provided in the study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 2 Trial of De-intensified Chemoradiation Therapy for Favorable-Risk Human Papillomavirus–Associated Oropharyngeal Squamous Cell Carcinoma

Purpose: To perform a prospective, multi-institutional, phase 2 study of a substantial decrease in concurrent chemoradiation therapy (CRT) intensity as primary treatment for favorable-risk, human papillomavirus–associated oropharyngeal squamous cell carcinoma. Methods and Materials: The major inclusion criteria were: (1) T0 to T3, N0 to N2c, M0; (2) human papillomavirus or p16 positive; and (3) minimal/remote smoking history. Treatment was limited to 60 Gy intensity modulated radiation therapy with concurrent weekly intravenous cisplatinum (30 mg/m{sup 2}). The primary study endpoint was pathologic complete response (pCR) rate based on required biopsy of the primary site and dissection of pretreatment positive lymph node regions, regardless of radiographic response. Power computations were performed for the null hypothesis that the pCR rate is 87% and n=40, resulting in a type 1 error of 14.2%. Secondary endpoint measures included physician-reported toxicity (Common Toxicity Terminology for Adverse Events, CTCAE), patient-reported symptoms (PRO-CTCAE), and modified barium swallow studies. Results: The study population was 43 patients. The pCR rate was 86% (37 of 43). The incidence of CTCAE grade 3/4 toxicity and PRO-CTCAE severe/very severe symptoms was as follows: mucositis 34%/45%, general pain 5%/48%, nausea 18%/52%, vomiting 5%/34%, dysphagia 39%/55%, and xerostomia 2%/75%. Grade 3/4 hematologic toxicities were 11%. Thirty-nine percent of patients required a feeding tube for a median of 15 weeks (range, 5-22 weeks). There were no significant differences in modified barium swallow studies before and after CRT. Conclusions: The pCR rate with decreased intensity of therapy with 60 Gy of IMRT and weekly low-dose cisplatinum is very high in favorable-risk oropharyngeal squamous cell carcinoma, with evidence of decreased toxicity compared with standard therapies. (ClinicalTrials.gov) ID: (NCT01530997).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-89: Accuracy of Absolute Three-Dimensional Dose Distribution Measurement Using the Delta4

Purpose: In this study, we investigated the accuracy of the absolute dose distribution measurement using the Delta4 phantom compared to the measurements using a ionization chamber and EDR2 film Methods: Several conventional and intensity-modulated radiation therapy plans were used to compare the dose distribution measured using the Delta4 phantom to the absolute point dose using the chamber and the relative two-dimensional dose distribution using the EDR2 film. For the absolute dose distribution evaluation, the measurements using the Delta4, the chamber and the film were performed in similar measurement geometry. For point dose measurement using the chamber, an acrylic slab phantom with the PTW Semiflex chamber was inserted into the Delta4 phantom, alternative to the Delta4 main unit. Similarly, for dose distribution measurement using the film, the EDR2 film sandwiched with two acrylic slab phantoms were inserted to the phantom. Dose difference and gamma analysis were done for point dose and relative dose distribution comparisons, respectively. Results: The point dose measurements show slight negative systematic dose difference of −0.5 ± 0.1% and −1.0 ± 0.4% in the conventional and the IMRT plans, respectively. The additional measurement for direction dependency for Delta4 shows similar negative systematic dose difference even the phantom analysis software consider the directional dependency. The pass rate of the gamma evaluation was 77.7 ± 5.8% and 88.8±3.3% in the conventional and the IMRT plans, respectively. Conclusions: The Delta4 phantom shows a 1%-systematic dose difference derived from directional dependency and lower resolution compared to the film. Thus it is necessary to comprehensively evaluate the phantom to verify the IMRT/VMAT plans. Especially, the dosimetry tool is needed to have high resolution and high measurement accuracy in IMRT/VMAT-SBRT plan with small fields using intensity modulation in which the analysis area is limited and the higher correspondence between calculation and measurement is needed.

60 APPLIED LIFE SCIENCES↗

Benchmark Credentialing Results for NRG-BR001: The First National Cancer Institute-Sponsored Trial of Stereotactic Body Radiation Therapy for Multiple Metastases

Purpose: The NRG-BR001 trial is the first National Cancer Institute–sponsored trial to treat multiple (range 2-4) extracranial metastases with stereotactic body radiation therapy. Benchmark credentialing is required to ensure adherence to this complex protocol, in particular, for metastases in close proximity. The present report summarizes the dosimetric results and approval rates. Methods and Materials: The benchmark used anonymized data from a patient with bilateral adrenal metastases, separated by <5 cm of normal tissue. Because the planning target volume (PTV) overlaps with organs at risk (OARs), institutions must use the planning priority guidelines to balance PTV coverage (45 Gy in 3 fractions) against OAR sparing. Submitted plans were processed by the Imaging and Radiation Oncology Core and assessed by the protocol co-chairs by comparing the doses to targets, OARs, and conformity metrics using nonparametric tests. Results: Of 63 benchmarks submitted through October 2015, 94% were approved, with 51% approved at the first attempt. Most used volumetric arc therapy (VMAT) (78%), a single plan for both PTVs (90%), and prioritized the PTV over the stomach (75%). The median dose to 95% of the volume was 44.8 ± 1.0 Gy and 44.9 ± 1.0 Gy for the right and left PTV, respectively. The median dose to 0.03 cm{sup 3} was 14.2 ± 2.2 Gy to the spinal cord and 46.5 ± 3.1 Gy to the stomach. Plans that spared the stomach significantly reduced the dose to the left PTV and stomach. Conformity metrics were significantly better for single plans that simultaneously treated both PTVs with VMAT, intensity modulated radiation therapy, or 3-dimensional conformal radiation therapy compared with separate plans. No significant differences existed in the dose at 2 cm from the PTVs. Conclusions: Although most plans used VMAT, the range of conformity and dose falloff was large. The decision to prioritize either OARs or PTV coverage varied considerably, suggesting that the toxicity outcomes in the trial could be affected. Several benchmarks met the dose-volume histogram metrics but produced unacceptable plans owing to low conformity. Dissemination of a frequently-asked-questions document improved the approval rate at the first attempt. Benchmark credentialing was found to be a valuable tool for educating institutions about the protocol requirements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-Trapped-Exciton Radiative Recombination in β–Ga 2 O 3 : Impact of Two Concurrent Nonradiative Auger Processes

The peculiarities of radiative and nonradiative processes associated with self-trapped intrinsic eXcitons in the excited β-Ga 2 O 3 crystals are studied via time-resolved techniques of induced absorption, transient grating, and photoluminescence (PL) at room temperature. The excitation above the bandgap is produced by laser pulses with linear light polarization parallel and orthogonal in the (–201) and (001) planes. We elucidate that the nonradiative recombination rate occurring in the eXciton prevails over its radiative emission rate in a wide range of free carrier concentration composed of excited and equilibrium electrons. Hence, the nonradiative recombination has no effect on the strong anisotropy and the shape of the eXciton emission band. However, we find out that the conventional ABC model of electron effective lifetime is insufficient for explanation of the excitation dependences. Inclusion of two nonradiative Auger mechanisms in a modified ABC formula provides excellent agreement of these dependences. We conclude that the trap-assisted Auger process is in proportion to the free electron density with coefficient B = 1.1 × 10 –11 cm 3 /s and appears at low/intermediate excitation, while the triple-particle Auger process is in proportion to Δn 2 with coefficient C = 8 × 10 –30 cm 6 /s and appears at high excitation conditions. The transition between two Auger mechanisms is accompanied by a rise of the eXciton diffusivity in preferred crystallographic directions where the radiative PL intensity is maximal. The diffusion length LD in these directions can reach values ~300 nm, but, at high excitations, LD becomes limited by Auger lifetimes. These findings pave the way for the implementation of self-trapped eXcitons into specific optoelectronic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The inter- and intrafraction reproducibilities of three common IMRT delivery techniques

Purpose: Intensity modulated radiation therapy (IMRT) treatment delivery requires higher precision than conventional 3D treatment delivery because of the sensitivity of the resulting dose to small geometric misalignment of the modulated beamlets. The chosen treatment delivery technique will affect the treatment precision in different ways, based on the characteristics of the delivery method. Delivery using a multileaf collimator (MLC) can reduce treatment time and therapist workload, but typically requires a greater number of monitor units and the fields are prone to both systematic and random leaf positioning errors. An alternative to MLC-based fields, patient specific brass compensators, do not suffer from these leaf positioning errors. In our study, we set out to investigate which delivery method will provide the highest levels of dosimetric reproducibility and the minimum amount of interfraction variability. Methods: In our study, a seven field IMRT plan for a head and neck treatment was created using the Pinnacle{sup 3} treatment planning system and the intensity maps for each field were obtained. The intensity maps of the fields were delivered with a Varian 2100C/D linear accelerator, using solid compensators and sliding window (SW) and step-and-shoot (SS) MLC segments. Three fields were selected from the seven-beam IMRT plan for comparison. Analysis was carried out using the MatriXX ion chamber array, radiochromic film, and Varian dynalog files. Results: Our results show that the error in MLC leaf positioning has no gantry angle dependence. The compensator and SW deliveries showed excellent agreement, even when stricter than usual gamma criteria were applied. However, we noted that under these strict conditions, the SS fields had at least ten times more pixels out of range than did the compensators. When using step-and-shoot MLC fields, it was observed that the increase in dose rate or the increase of MU/segment degrades the quality of the plan. Analysis of the dynalog files showed that while each individual field had its own propensity for error, all fields showed the same trend: a greater percentage of time the leaves are out of position as dose rate increases, MUs decrease, or both. Conclusions: The compensator-based field and both types of MLC-based fields have MatriXX results that are within the clinically acceptable tolerance of 3% dose difference and 2 mm DTA. However, when the criteria are tightened, it becomes evident that the compensators have a definite advantage over their comparable MLC-based competitors in terms of interfraction reproducibility. Fewer monitor units are required to deliver each portal, potentially improving patient outcomes and reducing unwanted side effects to both patients and therapists. In centers without MLC, compensators represent a simple and cost effective way to offer patients state of the art treatment. Based on the results of this study, compensator-based IMRT is a reliable, viable option for use in clinics both with and without MLC-equipped linacs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intensity clamping in the filament of femtosecond laser radiation

We have studied numerically the evolution of the light field intensity and induced refractive index of a medium upon filamentation of femtosecond laser radiation in air. It is shown that the intensity clamping results from the dynamic balance of optical powers of nonlinear lenses, induced by radiation due to the Kerr nonlinearity of air, and laser plasma produced during photoionisation. We have found the relation between the peak values of the light field intensity and the electron density in laser-produced plasma, as well as the transverse sizes of the filament and the plasma channel. (effects of laser radiation on matter)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predictors of Grade 3 or Higher Late Bowel Toxicity in Patients Undergoing Pelvic Radiation for Cervical Cancer: Results From a Prospective Study

Purpose: The present study investigates relationship between dose–volume parameters and severe bowel toxicity after postoperative radiation treatment (PORT) for cervical cancer. Methods and Materials: From June 2010 to December 2012, a total of 71 patients undergoing PORT were included. Small bowel (SB) and large bowel (LB) loops were contoured 2 cm above the target volume. The volume of SB and LB that received 15 Gy, 30 Gy, and 40 Gy was calculated (V15 SB, V15 LB, V30 SB, V30 LB, V40 SB, V 40 LB). On follow-up, bowel toxicity was scored using Common Terminology Criteria for Adverse Events (CTCAE), version 3.0. A reciever operating characteristic (ROC) curve identified volume thresholds that predicted for grade 3 or higher toxicity with highest specificity. All data was dichotomized across these identified cut-off values. Univariate and multivariate analysis was performed using SPSS, version 15. Results: The median patient age was 47 years (range, 35-65 years). Of the 71 patients, 46 received image-guided intensity modulated radiation therapy, and 25 received conformal radiation (50 Gy in 25 fractions for 5 weeks). Overall, 63 of 71 patients received concurrent chemotherapy. On a median follow-up of 18 months (range, 8-29 months), grade 2 or higher bowel toxicity was seen in 22 of 71 patients (30.9%) and grade 3 or higher bowel toxicity was seen in 9 patients (12.6%). On univariate analysis, V15 SB <275 cc (P=.01), V30 SB <190 cc (P=.02), V40 SB <150 cc (P=.01), and V15 LB <250 cc (P=.03), and V40 LB <90 cc (P=.04) predicted for absence of grade 3 or higher toxicity. No other patient- or treatment-related factors were statistically significant. On multivariate analysis, only V15 SB (P=.002) and V15 LB (P=.03) were statistically significant. Conclusions: V 15 Gy SB and LB are independent predictors of late grade 3 or higher toxicity. Restricting V15 SB and V15 LB to <275 cc and <250 cc can reduce grade 3 or higher toxicity to less than 5%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Numerical investigation of auroral cyclotron maser processes

When a mainly rectilinear electron beam is subject to significant magnetic compression, conservation of magnetic moment results in the formation of a horseshoe shaped velocity distribution. It has been shown that such a distribution is unstable to cyclotron emission and may be responsible for the generation of auroral kilometric radiation--an intense rf emission sourced at high altitudes in the terrestrial auroral magnetosphere. Particle-in-cell code simulations have been undertaken to investigate the dynamics of the cyclotron emission process in the absence of cavity boundaries with particular consideration of the spatial growth rate, spectral output and rf conversion efficiency. Computations reveal that a well-defined cyclotron emission process occurs albeit with a low spatial growth rate compared with waveguide bounded simulations. The rf output is near perpendicular to the electron beam with a slight backward-wave character reflected in the spectral output with a well defined peak at 2.68 GHz, just below the relativistic electron cyclotron frequency. The corresponding rf conversion efficiency of 1.1% is comparable to waveguide bounded simulations and consistent with the predictions of kinetic theory that suggest efficient, spectrally well defined emission can be obtained from an electron horseshoe distribution in the absence of radiation boundaries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗