Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Solid Xenon Project

Crystals like Germanium and Silicon need to be grown in specialized facilities which is time and money costly. It takes many runs to test the detector once it's manufactured and mishaps are very probable. It is of a great challenge to grow big germanium crystals and that's why stacking them up in a tower is the only way at the moment to increase testing mass. Liquid Noble gas experiments experiencing contamination problems, their predicted energy resolution at 10 keV and lower energy range is not as good as predicted. Every experiment is targeting one specific purpose, looking for one thing. Why not to design an experiment that is diverse and build a detector that can search for Dark Matter, Solar Axions, Neutrinoless Double Beta decay, etc. Solid Xenon detector is such detector. We designed a simple Xenon crystal growing chamber that was put together at Fermi National Accelerator Laboratory. The first phase of this experiment was to demonstrate that a good, crack free Xenon crystal can be grown (regardless of many failed attempts by various groups) and our first goal, 1 kg crystal, was successful.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying the host galaxy of gravitational wave signals

One of the goals of the current LIGO-GEO-Virgo science run is to identify transient gravitational wave (GW) signals in near real time to allow follow-up electromagnetic (EM) observations. An EM counterpart could increase the confidence of the GW detection and provide insight into the nature of the source. Current GW-EM campaigns target potential host galaxies based on overlap with the GW sky error box. We propose a new statistic to identify the most likely host galaxy, ranking galaxies based on their position, distance, and luminosity. We test our statistic with Monte Carlo simulations of GWs produced by coalescing binaries of neutron stars and black holes, one of the most promising sources for ground-based GW detectors. Considering signals accessible to current detectors, we find that when imaging a single galaxy, our statistic correctly identifies the true host {approx}20% to {approx}50% of the time, depending on the masses of the binary components. With five narrow-field images the probability of imaging the true host increases from {approx}50% to {approx}80%. When collectively imaging groups of galaxies using large field-of-view telescopes, the probability improves from {approx}30% to {approx}60% for a single image and from {approx}70% to {approx}90% for five images. For the advanced generation of detectors (circa 2015+), and considering binaries within 100 Mpc (the reach of the galaxy catalogue used), the probability is {approx}40% for one narrow-field image, {approx}75% for five narrow-field images, {approx}65% for one wide-field image, and {approx}95% for five wide-field images, irrespective of binary type.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Polarized Proton-Proton Elastic Scattering at RHIC

The Relativistic Heavy Ion Collider provides colliding polarized proton beams of 25 to 250 GeV/c momentum. With silicon strip detectors installed in Roman Pots at about 58 m on either side of the interaction point (IP) of the STAR detector, elastic scattering will be studied at a center of mass (cms) energy of 200 GeV and four momentum transfer squared range of 0.003 GeV{sup 2}/c{sup 2}<=|t|<=0.03 GeV{sup 2}/c{sup 2}, with 100% acceptance and full phi coverage. Measurements of single and double spin asymmetries will be carried out with special beam optics. An upgrade with additional Roman pots closer to the IP will increase the kinematic range to |t|<=1.5 GeV{sup 2}/c{sup 2} at sq root(s) = 500 GeV. Simulation studies of the detector acceptance for 200 GeV cms energy will be given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation tool for optical design of PET detector modules including scintillator material and sensor array

The appearance of single photon avalanche diodes (SPADs) in the field of PET detector modules made it necessary to apply more complex optical design methods to refine the performance of such assemblies. We developed a combined simulation tool that is capable to model complex detector structures including scintillation material, light guide, light collection optics and sensor, correctly taking into account the statistical behavior of emission of scintillation light and its absorbance in SPADs. As a validation we compared simulation results obtained by our software and another optical design program. Calculations were performed for a simple PET detector arrangement used for testing purposes. According to the results, deviation of center of gravity coordinates between the two simulations is 0.0195 mm, the average ratio of total counts 1.0052. We investigated the error resulting from finite sampling in wavelength space and we found that 20 nm pitch is sufficient for the simulation in case of the given spectral dependencies. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation damage resistance of AlGaN detectors for applications in the extreme-ultraviolet spectral range

We report on the fabrication of aluminum gallium nitride (AlGaN) Schottky-photodiode-based detectors. AlGaN layers were grown using metal-organic chemical vapor deposition (MOCVD) on Si(111) wafers. The diodes were characterized at a wavelength of 13.5 nm using a table-top extreme-ultraviolet (EUV) radiation source, consisting of a laser-produced xenon plasma and a Schwarzschild objective. The responsivity of the diodes was tested between EUV energies ranging from 320 nJ down to several picojoules. For low fluences, a linear responsivity of 7.14 mAs/J could be determined. Saturation starts at approximately 1 nJ, merging into a linear response of 0.113 mAs/J, which could be attributed to the photoeffect on the Au electrodes on top of the diode. Furthermore, degradation tests were performed up to an absolute dose of 3.3x10{sup 19} photons/cm{sup 2}. AlGaN photodiodes were compared to commercially available silicon-based photodetectors. For AlGaN diodes, responsivity does not change even for the highest EUV dose, whereas the response of the Si diode decreases linearly to {approx}93% after 2x10{sup 19} photons/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plane and hemispherical potential structures in magnetically expanding plasmas

Two-dimensional potential structures are measured for different gas pressure in expanding argon plasma using permanent magnets, where the magnetic field is about 100 G in the source and several gauss in the diffusion chamber. The plane potential drop is observed near the source exit for 0.35 mTorr, while the potential structure becomes hemispherical when increasing up to 1 mTorr; the hemispherical structure results in the radial divergence of the ion beam. It is found that the trajectories of the accelerated ions and the electrons overcoming the potential drop are dominated by the potential structure and magnetic-field lines, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Inclusive b and bb production with quasi-multi-Regge kinematics at the Tevatron

We consider b-jet hadroproduction in the quasi-multi-Regge-kinematics approach based on the hypothesis of gluon and quark Reggeization in t-channel exchanges at high energies. The preliminary data on inclusive b-jet and bb-dijet production taken by the CDF Collaboration at the Fermilab Tevatron are well described without adjusting parameters. We find the main contribution to inclusive b-jet production to be the scattering of a Reggeized gluon and a Reggeized b quark to a b quark, which is described by the effective Reggeon-Reggeon-quark vertex. The main contribution to bb-pair production arises from the scattering of two Reggeized gluons to a bb pair, which is described by the effective Reggeon-Reggeon-quark-quark vertex. Our analysis is based on the Kimber-Martin-Ryskin prescription for unintegrated gluon and quark distribution functions using as input the Martin-Roberts-Stirling-Thorne collinear parton distribution functions of the proton.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gravitational waves from low mass neutron stars

Low mass neutron stars may be uniquely strong sources of gravitational waves. The neutron star crust can support large deformations for low mass stars. This is because of the star's weaker gravity. We find maximum ellipticities {epsilon} (fractional difference in moments of inertia) that are 1000 times larger, and maximum quadrupole moments Q{sub 22} over 100 times larger, for low mass stars than for 1.4M{sub {center_dot}}neutron stars. Indeed, we calculate that the crust can support an {epsilon} as large as 0.005 for a minimum mass neutron star. A 0.12M{sub {center_dot}}star, that is maximally strained and rotating at 100 Hz, will produce a characteristic gravitational wave strain of h{sub 0}=2.1x10{sup -24} at a distance of 1 kpc. The gravitational wave detector Advanced LIGO should be sensitive to such objects through out the Milky Way Galaxy. A low mass neutron star could be uniquely identified from a large observed spin down rate and its discovery would have important implications for general relativity, supernova mechanisms, and possibly nucleosynthesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coherent pion production off nuclei at T2K and MiniBooNE energies revisited

As a result of a new improved fit to old bubble chamber data of the dominant axial C{sub 5}{sup A} nucleon-to-delta form factor, and due to the relevance of this form factor for neutrino induced coherent pion production, we reevaluate our model predictions in [Phys. Rev. D 79, 013002 (2009)] for different observables of the latter reaction. Central values for the total cross sections increase by 20%-30%, while differential cross sections do not change their shape appreciably. Furthermore, we also compute the uncertainties on total, differential, and flux-averaged cross sections induced by the errors in the determination of C{sub 5}{sup A}. Our new results turn out to be compatible within about 1{sigma} with the former ones. Finally, we stress the existing tension between the recent experimental determination of the ({sigma}(CCcoh{pi}{sup +})/{sigma}(NCcoh{pi}{sup 0})) ratio by the SciBooNE Collaboration and the theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pass-through Mach-Zehnder topologies for macroscopic quantum measurements

Several relatively small-scale experimental setups, aimed on prototyping of future laser gravitational-wave detectors and testing of new methods of quantum measurements with macroscopic mechanical objects, are under development now. In these devices, not devoted directly to the gravitational-wave detection, Mach-Zehnder interferometer with pass-through Fabry-Perot cavities in the arms can be used instead of the standard Michelson/Fabry-Perot one. The advantage of this topology is that it does not contain high-reflectivity end mirrors with multilayer coatings, which Brownian noise could constitute the major part of the noise budget of the Michelson/Fabry-Perot interferometers. We consider here two variants of this topology: the 'ordinary' position meter scheme, and a new variant of the quantum speed meter.

79 ASTRONOMY AND ASTROPHYSICS↗

MAD using INRAD and Radiography [Slides]

We have previously evaluated Intrinsic Radiation Detection Algorithms from vendors for the Department of Homeland Security. These algorithms have limited spectra capability due to both the relatively low spectral content of the signal due to the use of PVT in the Radiation Portal detectors as well as relatively simple algorithms which are based on energy windowing and other simple algorithms to perform classification of Special Nuclear Material. Current detection algorithms are suceptible to nuissance alarms due to Naturally Occuring Radiation (NORM) and variations in background suppression. In this work, we propose to fuse the intrinsic radiation and radiographic data in conjunction with well-established machine learning algorithms to developed enhanced Threat Object detection capability.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Performance of an X-ray single pixel TES microcalorimeter under DC and AC biasing

We are developing Frequency Domain Multiplexing (FDM) for the read-out of TES imaging microcalorimeter arrays for future X-ray missions like IXO. In the FDM configuration the TES is AC voltage biased at a well defined frequencies (between 0.3 to 10 MHz) and acts as an AM modulating element. In this paper we will present a full comparison of the performance of a TES microcalorimeter under DC bias and AC bias at a frequency of 370 kHz. In both cases we measured the current-to-voltage characteristics, the complex impedance, the noise, the X-ray responsivity, and energy resolution. The behaviour is very similar in both cases, but deviations in performances are observed for detector working points low in the superconducting transition (R/R{sub N}<0.5). The measured energy resolution at 5.89 keV is 2.7 eV for DC bias and 3.7 eV for AC bias, while the baseline resolution is 2.8 eV and 3.3 eV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager

Purpose: The increasing need for better image quality and high spatial resolution for successful endovascular image-guided interventions (EIGIs) and the inherent limitations of the state-of-the-art detectors provide motivation to develop a detector system tailored to the specific, demanding requirements of neurointerventional applications.Method: A microangiographic fluoroscope (MAF) was developed to serve as a high-resolution, region-of-interest (ROI) x-ray imaging detector in conjunction with large lower-resolution full field-of-view (FOV) state-of-the-art x-ray detectors. The newly developed MAF is an indirect x-ray imaging detector capable of providing real-time images (30 frames per second) with high-resolution, high sensitivity, no lag and low instrumentation noise. It consists of a CCD camera coupled to a Gen 2 dual-stage microchannel plate light image intensifier (LII) through a fiber-optic taper. A 300 {mu}m thick CsI(Tl) phosphor serving as the front end is coupled to the LII. The LII is the key component of the MAF and the large variable gain provided by it enables the MAF to operate as a quantum-noise-limited detector for both fluoroscopy and angiography. Results: The linear cascade model was used to predict the theoretical performance of the MAF, and the theoretical prediction showed close agreement with experimental findings. Linear system metrics such as MTF and DQE were used to gauge the detector performance up to 10 cycles/mm. The measured zero frequency DQE(0) was 0.55 for an RQA5 spectrum. A total of 21 stages were identified for the whole imaging chain and each stage was characterized individually. Conclusions: The linear cascade model analysis provides insight into the imaging chain and may be useful for further development of the MAF detector. The preclinical testing of the prototype detector in animal procedures is showing encouraging results and points to the potential for significant impact on EIGIs when used in conjunction with a state-of-art flat panel detector (FPD).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam Fields and Energy Dissipation Inside the the BE Beam Pipe of the Super-B Detector

We study the bunch field diffusion and energy dissipation in the beam pipe of the Super-B detector, which consists of two coaxial Be thin pipes (half a millimeter). Cooling water will run between these two pipes. Gold and nickel will be sputtered (several microns) onto the beryllium pipe at different sides. The Maxwell equations for the beam fields in these thin layers are solved numerically for the case of infinite pipes. We also calculate the amplitude of the electromagnetic fields outside the beam pipe, which may be noticeable as the beam current can reach 4 A in each beam. Results of simulations are used for the design of this central part of the Super-B detector.

43 PARTICLE ACCELERATORS↗

EDELWEISS-II : status and first results

The EDELWEISS-II experiment is devoted to the direct detection of WIMP dark matter, using a new generation of cryogenic germanium detectors. We will present preliminary results of the first operation of these detectors installed in the Modane underground laboratory. Very low radioactive background conditions are achieved. Furthermore, these new detectors, with a special electrode design for active rejection of surface events, have been experimentally shown to be suited for WIMP searches with spin-independent scattering cross-sections on a nucleon well below 10{sup -8} pb. Preliminary results of WIMP searches performed with a first set of these detectors will be shown as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗