Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Precision Pointing for the Laser Interferometry Space Antenna Mission

This viewgraph presentation discusses requirements for control systems in the design and production of space-based telescopes. Specific topics covered include: pointing control methods, wavefront control methods, vibration control methods and thermal control methods. Control systems on the Hubble Space Telescope and the James Webb Space Telescope are reviewed. Control system requirements for future space telescopes are also mentioned.

Hyde, T. Tupper↗

A Precision Metrology System for the Hubble Space Telescope Wide Field Camera 3 Instrument

The Wide Field Camera 3 (WFC3) instrument for the Hubble Space Telescope (HST) will replace the current Wide Field and Planetary Camera 2 (WFPC2). By providing higher throughput and sensitivity than WFPC2, and operating from the near-IR to the near-UV, WFC3 will once again bring the performance of HST above that from ground-based observatories. Crucial to the integration of the WFC3 optical bench is a pair of 2-axis cathetometers used to view targets which cannot be seen by other means when the bench is loaded into its enclosure. The setup and calibration of these cathetometers is described, along with results from a comparison of the cathetometer system with other metrology techniques.

Toland, Ronald W.↗

High Precision Laser Range Sensor

The present invention is an improved distance measuring interferometer that includes high speed phase modulators and additional phase meters to generate and analyze multiple heterodyne signal pairs with distinct frequencies. Modulation sidebands with large frequency separation are generated by the high speed electro-optic phase modulators, requiring only a single frequency stable laser source and eliminating the need for a fist laser to be tuned or stabilized relative to a second laser. The combination of signals produced by the modulated sidebands is separated and processed to give the target distance. The resulting metrology apparatus enables a sensor with submicron accuracy or better over a multi- kilometer ambiguity range.

Dubovitsky, Serge↗

Precise Laboratory Measurement of LINR Frequencies Useful to Studies of Star and Planet Formation

In March 2002, we began a program in laboratory spectroscopy to provide accurate molecular line frequencies essential to studies of the motions and abundances in star-froming dense cores and planet-forming circumstellar disks. The CN radical is one of the most important tracers of dynamical motions in protoplanetary disks around low mass pre-main sequence stars. The millimeter-wave spectrum of CN consists of rotational transitions every 113 GHz which are split into many resolved hyperfine components. Very narrow and fairly bright lines of SiO in the ground vibrational state have been observed in regions where protostellar outflows interact with the cold ambient gas. In support of future astronomical observations in these regions, 10 successive rotational lines in the ground vibrational state of Si0 between 86 and 500 GHz, and two lines near 800 GHz were measured in the laboratory to an accuracy of a few kHz. A negative glow discharge spectrometer that will allow the determination of accurate line frequencies of molecular ions has been constructed. We are presently modifying the method for cooling the magnetic field enhanced (negative glow) discharge cell to 77 K.

Myers, Philip C.↗

Measurement of Precision Geometric Distances to Three Anchor Points in the Local Universe

As stated in previous reports, our program, funded by a NASA/SARA 3-yr grant, is designed to measure distances directly with accuracies of 5% to three anchor points in the Local Universe. We are attacking this problem on three fronts, using Very Long Baseline Interferometry (VLBI) observations of NGC 4258, M 33, and Sgr A*. We plan to provide distance estimates, with a minimum of systematic uncertainty, that can be used to re- calibrate several "standard candles," such as Cepheid and RR Lyrae variables. This Will place the Galactic and extragalactic distance scales on much firmer ground. The program will provide crucial, independent checks and calibrations of extragalactic distance measurements, and will contribute to the ultimate success and impact of the HST Key Project on Extragalactic Distances and any future NASA astrometric missions. Additionally, since distances are fundamental to astrophysics, our results will affect a large number of general projects on NASA facilities such as the HST, CXO, and JWST.

Reid, Mark J.↗

ST7-DRS: A Step Towards Drag-free and High-precision Formation Control

The Space Technology 7 Disturbance Reduction System (ST7-DRS) is an in-space technology demonstration within NASA's New Millennium Program. ST7-DRS is designed to validate system-level technologies that are required for future gravity missions (including the planned LISA gravitational-wave observatory) and for future formation-flying interferometer missions (including the planned MAXIM black-hole imager). ST7-DRS is based around a freely-floating test mass contained within a spacecraft structure that will shield this test mass from all external forces (aside from gravity). The spacecraft position will be continuously controlled, such that the spacecraft, itself, will remain centered about this test mass, essentially flying in formation with it. Colloidal micro-thrusters will be used to control the spacecraft s position to within a few nanometers, over time scales of tens to thousands of seconds. In order to detect the residual acceleration noise on the main test mass, a second test mass will be flown alongside the first, within the same physical spacecraft structure. This test mass will serve as a cross-reference for the first, and will also be used as a reference for the spacecraft's attitude control. The spacecraft's attitude will be controlled to an accuracy of a few milli-arc-seconds, also utilizing the colloidal micro-thrusters. ST7-DRS will consist of an instrument package (containing the test masses) and a set of micro-thrusters, which will be attached to the European Space Agency s SMART-2 spacecraft, set to launch in November 2007.

Houghton, M.↗

A Three-Axis Fixed-Simulator Investigation of the Effects on Control Precision of Various Ways of Utilizing Rate Signals

A three-axis vehicle control study has been made by use of a fixed simulator and analog computing equipment, to evaluate the effects of various ways of utilizing rate information. A side-arm controller providing proportional acceleration control was used with a simulated vehicle having no inherent stability or damping. Vehicle rate signals were used to provide control feedback or system damping and were used in the instrument display either separate from or summed with displacement signals. Near optimum performance of both transitions in roll and control of system disturbance was obtained by using a combination of system damping and summed displacement signals and rate signals.

McKee, John W.↗

A Precision Metrology System for the Hubble Space Telescope Wide Field Camera 3 Instrument

The Wide Field Camera 3 (WFC3) instrument for the Hubble Space Telescope (HST) will replace the current Wide Field and Planetary Camera 2 (WFPC2). By providing higher throughput and sensitivity than WFPC2, and operating from the near-IR to the near-UV, WFC3 will once again bring the pefiormance of HST above that from ground-based observatories. Crucial to the integration of the WFC3 optical bench is a pair of 2-axis cathetometers used to view targets which cannot be seen by other means when the bench is loaded into its enclosure. The setup and calibration of these cathetometers is described, along with results from a comparison of the cathetometer system with other metrology techniques. Finally, the use of the cathetometers on the flight optical bench and measurement results are given.

Toland, Ronald W.↗

Magnesium Isotopes in the Earth, Moon, Mars, and Pallasite Parent Body: High-Precision Analysis of Olivine by Laser-Ablation Multi-Collector ICPMS

Magnesium isotopes potentially offer new insights into a diverse range of processes including evaporation and condensation in the solar nebula, melting and metasomatism in planetary interiors, and hydrothermal alteration [1,2,3,4]. Volatility-related Mg isotopic variations of up to 10 per mil/amu relative to a terrestrial standard have been found in early nebular phases interpreted as evaporation residues [1], and relatively large variations (up to 3 per mil/amu) in the terrestrial mantle have been reported recently [4]. In order to investigate possible differences in the nebular history of material contributing to the terrestrial planets, and to search for evidence of a high-temperature origin of the Moon, we have measured the magnesium isotopic composition of primitive olivines from the Earth, Moon, Mars, and pallasite parent body using laser-ablation multicollector ICPMS.

Norman, M.↗

Mitigation of the Impact of Sensing Noise on the Precise Formation Flying Control Problem

The specific objectives of this proposed research were: 1. Further investigation into the impact of CDGPS sensing errors for high Earth orbit missions. 2. Identify augmentation approaches of the CDGPS that will improve the relative state for low and high Earth orbit missions. 3. Integration of the navigation and control concepts into the GSFC Formation Flying Testbed. In addition this was a cooperative effort with Dr. Jonathan How at MIT. Dr. Alfriend was to spend two weeks working with Dr. How and his students. The travel for these two weeks was paid by the Texas Engineering Experiment Station (TEES) as cost sharing.

Alfriend, K. T.↗

Accuracy and Precision in the Southern Hemisphere Additional Ozonesondes (SHADOZ) Dataset 1998-2000 in Light of the JOSIE-2000 Results

A network of 12 southern hemisphere tropical and subtropical stations in the Southern Hemisphere ADditional OZonesondes (SHADOZ) project has provided over 2000 profiles of stratospheric and tropospheric ozone since 1998. Balloon-borne electrochemical concentration cell (ECC) ozonesondes are used with standard radiosondes for pressure, temperature and relative humidity measurements. The archived data are available at:http: //croc.gsfc.nasa.gov/shadoz. In Thompson et al., accuracies and imprecisions in the SHADOZ 1998- 2000 dataset were examined using ground-based instruments and the TOMS total ozone measurement (version 7) as references. Small variations in ozonesonde technique introduced possible biases from station-to-station. SHADOZ total ozone column amounts are now compared to version 8 TOMS; discrepancies between the two datasets are reduced 2\% on average. An evaluation of ozone variations among the stations is made using the results of a series of chamber simulations of ozone launches (JOSIE-2000, Juelich Ozonesonde Intercomparison Experiment) in which a standard reference ozone instrument was employed with the various sonde techniques used in SHADOZ. A number of variations in SHADOZ ozone data are explained when differences in solution strength, data processing and instrument type (manufacturer) are taken into account.

Witte, J. C.↗

Precision Clean Hardware: Maintenance of Fluid Systems Cleanliness

The ISS fluid systems are so complex that fluid system cleanliness cannot be verified at the assembly level. A "build clean / maintain clean" approach was used by all major fluid systems: Verify cleanliness at the detail and subassembly level. Maintain cleanliness during assembly.

Sharp, Sheila↗

Accuracy and Precision in the Southern Hemisphere Additional Ozonesondes (SHADOZ) Dataset in Light of the JOSIE-2000 Results

Since 1998 the Southern Hemisphere ADditional OZonesondes (SHADOZ) project has provided over 2000 ozone profiles over eleven southern hemisphere tropical and subtropical stations. Balloon-borne electrochemical concentration cell (ECC) ozonesondes are used to measure ozone. The data are archived at: &ttp://croc.gsfc.nasa.gov/shadoz>. In analysis of ozonesonde imprecision within the SHADOZ dataset, Thompson et al. [JGR, 108,8238,20031 we pointed out that variations in ozonesonde technique (sensor solution strength, instrument manufacturer, data processing) could lead to station-to-station biases within the SHADOZ dataset. Imprecisions and accuracy in the SHADOZ dataset are examined in light of new data. First, SHADOZ total ozone column amounts are compared to version 8 TOMS (2004 release). As for TOMS version 7, satellite total ozone is usually higher than the integrated column amount from the sounding. Discrepancies between the sonde and satellite datasets decline two percentage points on average, compared to version 7 TOMS offsets. Second, the SHADOZ station data are compared to results of chamber simulations (JOSE-2000, Juelich Ozonesonde Intercomparison Experiment) in which the various SHADOZ techniques were evaluated. The range of JOSE column deviations from a standard instrument (-10%) in the chamber resembles that of the SHADOZ station data. It appears that some systematic variations in the SHADOZ ozone record are accounted for by differences in solution strength, data processing and instrument type (manufacturer).

Witte, Jacquelyn C.↗

Stabilization of posture by precision touch of the index finger with rigid and flexible filaments

Light touch of the index finger with a stationary surface at non-mechanically supportive force levels (<100 g) greatly attenuates the body sway of standing subjects. In three experiments, we evaluated the properties of finger contact and of the contacted object necessary to produce postural stabilization in subjects standing heel-to-toe with eyes closed, as well as how accurately hand position can be controlled. Experiment 1 involved finger contact with flexible filaments of different bending strengths, a flat surface, and an imagined spatial position. Contact with the flat surface was most effective in attenuating sway; the flexible filaments were much less effective but still significantly better than imagined contact. Experiment 2 compared the effectiveness of finger contact with a flexible filament, a rigid filament of the same diameter, a flat surface, and an imagined spatial position. The rigid filament and flat surface conditions were equally effective in attenuating body sway and were greatly superior to contact with the flexible filament, which was superior to imagined contact. Experiment 3 included five conditions: arms by sides; finger "contact" with an imagined spatial position; finger contact with a flat surface; finger contact with a flexible filament attempting to maintain it bent; and contact with the flexible filament attempting not to bend it. The arms by sides and finger "contact" with an imagined position conditions did not differ significantly; all three conditions involving actual finger contact showed significantly less center of pressure and hand sway, but contact with the flat surface was most effective in attenuating both postural and hand displacement. In all three experiments, the level of force applied in fingertip contact conditions was far below that necessary to provide mechanical stabilization. Our findings indicate that: (1) stimulation of a small number of receptors in the fingertip is adequate to allow stabilization of sway, (2) fingertip force levels as low as 5-10 g provide some stabilization, (3) contact with a stationary spatial referent is most effective, and (4) independent control of arm and torso occurs when finger contact is allowed.

NASA Discipline Neuroscience↗

Precision contact of the fingertip reduces postural sway of individuals with bilateral vestibular loss

Contact of the hand with a stationary surface attenuates postural sway in normal individuals even when the level of force applied is mechanically inadequate to dampen body motion. We studied whether subjects without vestibular function would be able to substitute contact cues from the hand for their lost labyrinthine function and be able to balance as well as normal subjects in the dark without finger contact. We also studied the relative contribution of sight of the test chamber to the two groups. Subjects attempted to maintain a tandem Romberg stance for 25 s under three levels of fingertip contact: no contact; light-touch contact, up to 1 N (approximately 100 g) force; and unrestricted contact force. Both eyes open and eyes closed conditions were evaluated. Without contact, none of the vestibular loss subjects could stand for more than a few seconds in the dark without falling; all the normals could. The vestibular loss subjects were significantly more stable in the dark with light touch of the index finger than the normal subjects in the dark without touch. They also swayed less in the dark with light touch than when permitted sight of the test chamber without touch, and less with sight and touch than just sight. The normal subjects swayed less in the dark with touch than without, and less with sight and touch than sight alone. These findings show that during quiet stance light touch of the index finger with a stationary surface can be as effective or even more so than vestibular function for minimizing postural sway.

NASA Discipline Neuroscience↗

High Precision Metrology on the Ultra-Lightweight W 50.8 cm f/1.25 Parabolic SHARPI Primary Mirror using a CGH Null Lens

For potential use on the SHARPI mission, Eastman Kodak has delivered a 50.8cm CA f/1.25 ultra-lightweight UV parabolic mirror with a surface figure error requirement of 6nm RMS. We address the challenges involved in verifying and mapping the surface error of this large lightweight mirror to +/-3nm using a diffractive CGH null lens. Of main concern is removal of large systematic errors resulting from surface deflections of the mirror due to gravity as well as smaller contributions from system misalignment and reference optic errors. We present our efforts to characterize these errors and remove their wavefront error contribution in post-processing as well as minimizing the uncertainty these calculations introduce. Data from Kodak and preliminary measurements from NASA Goddard will be included.

Antonille, Scott↗

Precise Laboratory Measurement of Line Frequencies Useful to Studies of Star and Planet Formation

In March 2002, we began a program in laboratory spectroscopy to provide accurate molecular line frequencies essential to studies of the motions and abundance in star-forming dense cores and planet-forming circumstellar disks. Summarized here is the progress that has been made in Year 3 of this grant. Work included measurement of 10 successive rotational lines in the ground vibrational state of SiO between 86 and 500 GHz, and two lines near 800 GHz to an accuracy of a few kHz; conducting pilot experiments on molecular ions in collision-free supersonic beams, including HCO+, N2H+, and H2D+; measurement of 22 lines of CN between 113 and 340 GHz; and setting up an experiment that would allow us to refine earlier measurements of the neutral species such as C3H2, CCS, H2CS, and SO by observing the very narrow sub-Doppler (Lamb dip) features in the millimeter-wave spectra of these species.

Myers, Philip C.↗

Measurement of Precision Geometric Distances to Three Anchor Points in the Local Universe

Our program, funded by a NASA/SARA 3-yr grant, seeks to provide a much improved foundation of r the extra-galactic distance scale. The goal is to measure geometric distances with accuracies of 5% of better to several anchor points in the Local Universe. There are three objects that we are observing in order to attack this problem: NGC 4258, M 33, and Sgr A*. We plan to provide distance estimates, with a minimum of systematic uncertainty, that can be used to recalibrate several "standard candles," such as Cepheid and RR Lyrae variables. This will place the extragalactic distance scales on much firmer ground. The program will provide crucial, independent checks and calibrations of extragalactic distance measurements, and will contribute to the ultimate success and impact of the HST Key Project on Extragalactic Distances and any future NASA astrometric missions. Additionally, since distances are fundamental to astrophysics, our results will affect a large number of general projects on NASA facilities such s the HST, CXO, and JWST.

Reid, Mark J.↗