Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Parameter Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

SU-C-213-03: Custom 3D Printed Boluses for Radiation Therapy

Purpose: To develop a clinical workflow and to commission the process of creating custom 3d printed boluses for radiation therapy. Methods: We designed a workflow to create custom boluses using a commercial 3D printer. Contours of several patients were deformably mapped to phantoms where the test bolus contours were designed. Treatment plans were created on the phantoms following our institutional planning guideline. The DICOM file of the bolus contours were then converted to stereoLithography (stl) file for the 3d printer. The boluses were printed on a commercial 3D printer using polylactic acid (PLA) material. Custom printing parameters were optimized in order to meet the requirement of bolus composition. The workflow was tested on multiple anatomical sites such as skull, nose and chest wall. The size of boluses varies from 6×9cm2 to 12×25cm2. To commission the process, basic CT and dose properties of the printing materials were measured in photon and electron beams and compared against water and soft superflab bolus. Phantoms were then scanned to confirm the placement of custom boluses. Finally dose distributions with rescanned CTs were compared with those computer-generated boluses. Results: The relative electron density(1.08±0.006) of the printed boluses resemble those of liquid tap water(1.04±0.004). The dosimetric properties resemble those of liquid tap water(1.04±0.004). The dosimetric properties were measured at dmax with an ion chamber in electron and photon open beams. Compared with solid water and soft bolus, the output difference was within 1% for the 3D printer material. The printed boluses fit well to the phantom surfaces on CT scans. The dose distribution and DVH based on the printed boluses match well with those based on TPS generated boluses. Conclusion: 3d printing provides a cost effective and convenient solution for patient-specific boluses in radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-265: Development of Dose-To-Water Conversion Models for Pre-Treatment Verification with the New AS1200 Imager

Purpose: To develop and evaluate models for dose verification of flattened (FF) and flattening filter free (FFF) beams for the new Varian aS1200 backscatter-shielded electronic portal imaging device (EPID). Methods: The model converts EPID images to incident energy fluence using deconvolution of EPID scatter kernels and fluence to dose in water using convolution with dose-to-water kernels. Model parameters were optimized using non-transmission EPID images of varying jaw defined field sizes for energies of 6 and 10 MV FF and FFF beams. Energy fluence was obtained from the Acuros planning system and reference dose profiles and output factors were measured at depths of 5, 10, 15 and 20 cm in a water phantom. Images for 34 IMRT fields acquired at 6 and 10 MV FF energy were converted to dose at 10 cm depth in water and compared to treatment planning system dose plane calculations using gamma criteria. Results: Gamma evaluations for the IMRT fields had mean (1 standard deviation) pass rates of 99.4% (0.8%) and mean gamma scores of 0.32 (0.06) with 2%, 2 mm criteria and 10% of maximum dose threshold. Conclusion: The developed model has been shown to be highly accurate for pre-treatment verification with the new aS1200 imager which does not display support-arm backscatter artefact and has improved dosimetric properties. Further investigation of FFF modes is in progress. The model is currently being evaluated at sites for potential clinical release.

60 APPLIED LIFE SCIENCES↗

SU-E-T-664: Radiobiological Modeling of Prophylactic Cranial Irradiation in Mice

Purpose: Prophylactic cranial irradiation (PCI) is a clinical technique used to reduce the incidence of brain metastasis and improve overall survival in select patients with ALL and SCLC, and we have shown the potential of PCI in select breast cancer patients through a mouse model (manuscript in preparation). We developed a computational model using our experimental results to demonstrate the advantage of treating brain micro-metastases early. Methods: MATLAB was used to develop the computational model of brain metastasis and PCI in mice. The number of metastases per mouse and the volume of metastases from four- and eight-week endpoints were fit to normal and log-normal distributions, respectively. Model input parameters were optimized so that model output would match the experimental number of metastases per mouse. A limiting dilution assay was performed to validate the model. The effect of radiation at different time points was computationally evaluated through the endpoints of incidence, number of metastases, and tumor burden. Results: The correlation between experimental number of metastases per mouse and the Gaussian fit was 87% and 66% at the two endpoints. The experimental volumes and the log-normal fit had correlations of 99% and 97%. In the optimized model, the correlation between number of metastases per mouse and the Gaussian fit was 96% and 98%. The log-normal volume fit and the model agree 100%. The model was validated by a limiting dilution assay, where the correlation was 100%. The model demonstrates that cells are very sensitive to radiation at early time points, and delaying treatment introduces a threshold dose at which point the incidence and number of metastases decline. Conclusion: We have developed a computational model of brain metastasis and PCI in mice that is highly correlated to our experimental data. The model shows that early treatment of subclinical disease is highly advantageous.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-AB-204-10: Evaluation of a Novel Dedicated Breast PET System (Mammi-PET)

Purpose: To evaluate the performance characteristics of a novel dedicated breast PET system (Mammi-PET, Oncovision). The system has 2 detector rings giving axial/transaxial field of view of 8/17 cm. Each ring consists of 12 monolithic LYSO modules coupled to PSPMTs. Methods: Uniformity, sensitivity, energy and spatial resolution were measured according to NEMA standards. Count rate performance was investigated using a source of F-18 (1384uCi) decayed over 5 half-lives. A prototype PET phantom was imaged for 20 min to evaluate image quality, recovery coefficients and partial volume effects. Under an IRB-approved protocol, 11 patients who just underwent whole body PET/CT exams were imaged prone with the breast pendulant at 5–10 minutes/breast. Image quality was assessed with and without scatter/attenuation correction and using different reconstruction algorithms. Results: Integral/differential uniformity were 9.8%/6.0% respectively. System sensitivity was 2.3% on axis, 2.2% and 2.8% at 3.8 cm and 7.8 cm off-axis. Mean energy resolution of all modules was 23.3%. Spatial resolution (FWHM) was 1.82 mm and 2.90 mm on axis and 5.8 cm off axis. Three cylinders (14 mm diameter) in the PET phantom were filled with activity concentration ratios of 4:1, 3:1, and 2:1 relative to the background. Measured cylinder to background ratios were 2.6, 1.8 and 1.5 (without corrections) and 3.6, 2.3 and 1.5 (with attenuation/scatter correction). Five cylinders (14, 10, 6, 4 and 2 mm diameter) each with an activity ratio of 4:1 were measured and showed recovery coefficients of 1, 0.66, 0.45, 0.18 and 0.18 (without corrections), and 1, 0.53, 0.30, 0.13 and 0 (with attenuation/scatter correction). Optimal phantom image quality was obtained with 3D MLEM algorithm, >20 iterations and without attenuation/scatter correction. Conclusion: The MAMMI system demonstrated good performance characteristics. Further work is needed to determine the optimal reconstruction parameters for qualitative and quantitative applications.

60 APPLIED LIFE SCIENCES↗

SU-F-T-367: Using PRIMO, a PENELOPE-Based Software, to Improve the Small Field Dosimetry of Linear Accelerators

Purpose: To calculate output correction factors for Varian Clinac 2100iX beams for seven small field detectors and use the values to determine the small field output factors for the linacs at Karolinska university hospital. Methods: Phase space files (psf) for square fields between 0.25cm and 10cm were calculated using the PENELOPE-based PRIMO software. The linac MC-model was tuned by comparing PRIMO-estimated and experimentally determined depth doses and lateral dose-profiles for 40cmx40cm fields. The calculated psf were used as radiation sources to calculate the correction factors of IBA and PTW detectors with the code penEasy/PENELOPE. Results: The optimal tuning parameters of the MClinac model in PRIMO were 5.4 MeV incident electron energy and zero energy spread, focal spot size and beam divergence. Correction factors obtained for the liquid ion chamber (PTW-T31018) are within 1% down to 0.5 cm fields. For unshielded diodes (IBA-EFD, IBA-SFD, PTW-T60017 and PTW-T60018) the corrections are up to 2% at intermediate fields (>1cm side), becoming down to −11% for fields smaller than 1cm. The shielded diode (IBA-PFD and PTW-T60016) corrections vary with field size from 0 to −4%. Volume averaging effects are found for most detectors in the presence of 0.25cm fields. Conclusion: Good agreement was found between correction factors based on PRIMO-generated psf and those from other publications. The calculated factors will be implemented in output factor measurements (using several detectors) in the clinic. PRIMO is a userfriendly general code capable of generating small field psf and can be used without having to code own linac geometries. It can therefore be used to improve the clinical dosimetry, especially in the commissioning of linear accelerators. Important dosimetry data, such as dose-profiles and output factors can be determined more accurately for a specific machine, geometry and setup by using PRIMO and having a MC-model of the detector used.

43 PARTICLE ACCELERATORS↗

Practical reconstruction protocol for quantitative {sup 90}Y bremsstrahlung SPECT/CT

Purpose: To develop a practical background compensation (BC) technique to improve quantitative {sup 90}Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. Methods: All images were acquired using medium-energy collimation in six energy windows (EWs), ranging from 70 to 410 keV. The EWs were determined based on the signal-to-background ratio in planar images of an acrylic phantom of different thicknesses (2–16 cm) positioned below a {sup 90}Y source and set at different distances (15–35 cm) from a gamma camera. The authors adapted the widely used EW-based scatter-correction technique by modeling the BC as scaled images. The BC EW was determined empirically in SPECT/CT studies using an IEC phantom based on the sphere activity recovery and residual activity in the cold lung insert. The scaling factor was calculated from 20 clinical planar {sup 90}Y images. Reconstruction parameters were optimized in the same SPECT images for improved image quantification and contrast. A count-to-activity calibration factor was calculated from 30 clinical {sup 90}Y images. Results: The authors found that the most appropriate imaging EW range was 90–125 keV. BC was modeled as 0.53× images in the EW of 310–410 keV. The background-compensated clinical images had higher image contrast than uncompensated images. The maximum deviation of their SPECT calibration in clinical studies was lowest (<10%) for SPECT with attenuation correction (AC) and SPECT with AC + BC. Using the proposed SPECT-with-AC + BC reconstruction protocol, the authors found that the recovery coefficient of a 37-mm sphere (in a 10-mm volume of interest) increased from 39% to 90% and that the residual activity in the lung insert decreased from 44% to 14% over that of SPECT images with AC alone. Conclusions: The proposed EW-based BC model was developed for {sup 90}Y bremsstrahlung imaging. SPECT with AC + BC gave improved lesion detectability and activity quantification compared to SPECT with AC only. The proposed methodology can readily be used to tailor {sup 90}Y SPECT/CT acquisition and reconstruction protocols with different SPECT/CT systems for quantification and improved image quality in clinical settings.

61 RADIATION PROTECTION AND DOSIMETRY↗

Battery charging goes quantum

Rechargeable lithium-ion batteries power consumer electronics and electric vehicles, making them an essential component of the modern economy. Although lithium-ion battery technology has improved continuously over the past decades, widespread adoption of electrified transportation requires charging in less than 15 min to be competitive with internal combustion engines. As a battery charges and discharges, lithium ions travel across the electrode-electrolyte interface. The rate at which lithium ions transfer is dictated by the structure and physical properties of electrolytes and lithium-storing electrodes. Yet, the exact chemical reaction mechanism underlying the insertion of lithium ions at the electrode-electrolyte interface remains elusive. On page 46 of this issue, Zhang et al. (1) report experimental evidence that shows that lithium-ion battery charge and discharge occur through a coupled ion-electron transfer mechanism. Furthermore, this could establish an experimental and theoretical platform to extract key parameters for optimizing charge transfer rates in lithium-ion batteries.

Warburton, Robert E. [Case Western Reserve Univers↗

Optimization of sensors based on surface waves in flat-layered structures

A method for increasing the sensitivity of surface-wave sensors in multifilm structures is proposed based on the results of a theoretical study of the reflection of a plane electromagnetic wave from a flat-layered structure containing homogeneous films. A method for optimizing the parameters of the films forming the surface structure is developed and tested. The devices proposed are characterized by high field amplification in a surface layer of multifilm structure and a higher sensitivity to variations in the optical properties of the thin near-surface layer. Application of the proposed multifilm structures is expected to increase significantly the sensitivity of the existing sensors based on surface-plasmon polaritons, which are applied in modern optical multichannel biological, chemical, and physical sensor systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of nonneutral plasma storage in a magnetic trap with a rotating electric field at the lepta facility

Results from experimental studies of plasma storage in a Penning-Malmberg trap at the LEPTA facility are presented. The number of stored particles is found to increase substantially when using the so-called “rotating wall” method, in which a transverse rotating electric field generated by a cylindrical segmented electrode cut into four pairs is applied to the plasma storage region. The conditions of transverse compression of the plasma bunch under the action of the rotating field and buffer gas are studied. The optimal storage parameters are determined for these experimental conditions. Mechanisms of the action of the rotating field and buffer gas on the process of plasma storage are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonant features of the terahertz generation in semiconductor nanowires

The paper presents the results of experimental studies of the generation of terahertz radiation in periodic arrays of GaAs nanowires via excitation by ultrashort optical pulses. It is found that the generation of THz radiation exhibits resonant behavior due to the resonant excitation of cylindrical modes in the nanowires. At the optimal geometric parameters of the nanowire array, the generation efficiency is found to be higher than that for bulk p-InAs, which is one of the most effective coherent terahertz emitters.

36 MATERIALS SCIENCE↗

Study of the deposition features of the organic dye Rhodamine B on the porous surface of silicon with different pore sizes

The deposition features of the organic dye Rhodamine B on the porous surface of silicon with average pore sizes of 50–100 and 100–250 nm are studied. Features of the composition and optical properties of the obtained systems are studied using infrared and photoluminescence spectroscopy. It is found that Rhodamine-B adsorption on the surface of por-Si with various porosities is preferentially physical. The optimal technological parameters of its deposition are determined.

36 MATERIALS SCIENCE↗

Oxide Removal from the InSb Plate Surface to Produce Lateral Spin Valves

Abstracts: The formation conditions of a smooth and oxide-free surface of InSb semiconductor with the purpose of fabricating lateral spin devices based on it are investigated. The dry etching rate by Ar ions of the surface of the crystalline faces (100) of InSb plates as well as a variation in their roughness depending on the power supplied to ion etching devices are investigated. The degree of oxidation of the semiconductor surface exposed to air after ion cleaning and annealing in molecular hydrogen are evaluated. Based on comparison of the efficiency of spin injection in devices formed with semiconductors subjected to various types of treatment, a conclusion is made about the parameters of optimal preparation of the surface of the InSb wafers for the fabrication of lateral spin devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Connecting Material Properties and Redox Flow Cell Cycling Performance through Zero-Dimensional Models

Improvements in redox flow battery (RFB) performance and durability can be achieved through the development of new active materials, electrolytes, and membranes. While a rich design space exists for emerging materials, complex tradeoffs challenge the articulation of unambiguous target criteria, as the relationships between component selection and cycling performance are multifaceted. Here, we derive zero-dimensional, analytical expressions for mass balances and cell voltages under galvanostatic cycling, enabling direct connections between material/electrolyte properties, cell operating conditions, and resulting performance metrics (e.g., energy efficiency, capacity fade). To demonstrate the utility of this modeling framework, we highlight several considerations for RFB design, including upper bound estimation, active species decay, and membrane/separator conductivity-selectivity tradeoffs. Furthermore, we also discuss modalities for extending this framework to incorporate kinetic losses, distributed ohmic losses, and multiple spatial domains. Importantly, because the mass balances are solved analytically, hundreds of cycles can be simulated in seconds, potentially facilitating detailed parametric sweeps, system optimization, and parameter estimation from cycling experiments. More broadly, this approach provides a means for assessing the impact of cell components that simultaneously influence multiple performance-defining processes, aiding in the elucidation of key descriptors and the identification of favorable materials combinations for specific applications.

25 ENERGY STORAGE↗

High Resolution Aerosol Jet Printed Components with Electrodeposition-Enhanced Conductance

Aerosol Jet Printing (AJP) is one technique of additive manufacturing used in the printing of electronics components. AJP enables the patterning of features at the ~10 μm–100 μm scale based on hardware and print parameters. Additionally, optimization of print conditions enables the printing of high-resolution features with linewidths approaching 10 μm. The aerosol jet printing of electronic parts can be limited by the conductivities which are achievable by Ag nanoparticle inks (typically 15%–25% of bulk Ag). For certain electronics applications, the increased conductivity produces unacceptable loses during operation and methods are needed to increase the conductance of the devices without sacrificing resolution. Here, we report on the AJP of inductor spirals conductor traces of linewidth 50 μm separated by 55 μm gaps. The conductivity of these features is enhanced by electrodeposition of Cu onto the Ag, resulting in a decrease in resistance of 35–45x. Impedance measurements demonstrate that the addition of Cu by electrodeposition to a 27-turn spiral inductor resulted in an inductance of 3.6 μH. Finally, we demonstrate the use of a lift-off process to produce free-standing, flexible, conductive films using AJP.

36 MATERIALS SCIENCE↗

Neural Networks for Supercapacitor Modeling

This software implements a one-dimensional model of a supercapacitor and calibrates it to experimental data. A system of coupled partial differential equation models the salt concentration and the ionic and electronic potentials. The term in the equation modeling the capacitance contains a neural network, whose parameters are optimized to fit the provided experimental data. The software is written in python using the open-source library JAX to calculate the gradients needed for the optimization.

Salazar de Troya, Miquel↗

Out of Distribution Detection with Neural Network Anchoring

This is code to reproduce and build on OOD detection from the paper "Out of Distribution Detection with Neural Network Anchoring". Our goal here is to exploit heteroscedastic temperature scaling as a calibration strategy for out of distribution (OOD) detection. Heteroscedasticity here refers to the fact that the optimal temperature parameter for each sample can be different, as opposed to conventional approaches that use the same value for the entire distribution. To enable this, we propose a new training strategy called anchoring that can estimate appropriate temperature values for each sample, leading to state-of-the-art OOD detection performance across several benchmarks. Using NTK theory, we show that this temperature function estimate is closely linked to the epistemic uncertainty of the classifier, which explains its behavior. In contrast to some of the best-performing OOD detection approaches, our method does not require exposure to additional outlier datasets, custom calibration objectives, or model ensembling. Through empirical studies with different OOD detection settings - far OOD, near OOD, and semantically coherent OOD - we establish a highly effective OOD detection approach.

Thiagarajan, Jayaraman↗

Cylindrical battery design app

Software that delivers optimal design parameters and performance predictions for cylindrical cells, which can range in size from microbatteries to EV batteries, is developed. The software utilizes machine learning and includes a graphical user interface to enable rapid prototyping and to accelerate energy storage research, development, and manufacturing. The Cylindrical battery design V1.0 comprises of three types of cylindrical batteries, Microbattery (Primary), Microbattery (Secondary) and 18650/21700/xxxxx Cylindrical battery. The software was developed in MATLAB. The software has the capability to output the cell design with the capacity ranges from several mAh to several million Ah.

Xiao, Jie↗

Discrete event performance prediction of speculatively parallel temperature-accelerated dynamics

Due to its unrivaled ability to predict the dynamical evolution of interacting atoms, molecular dynamics (MD) is a widely used computational method in theoretical chemistry, physics, biology, and engineering. Despite its success, MD is only capable of modeling time scales within several orders of magnitude of thermal vibrations, leaving out many important phenomena that occur at slower rates. The Temperature Accelerated Dynamics (TAD) method overcomes this limitation by thermally accelerating the state-to-state evolution captured by MD. Due to the algorithmically complex nature of the serial TAD procedure, implementations have yet to improve performance by parallelizing the concurrent exploration of multiple states. Here we utilize a discrete event-based application simulator to introduce and explore a new Speculatively Parallel TAD (SpecTAD) method. We investigate the SpecTAD algorithm, without a full-scale implementation, by constructing an application simulator proxy (SpecTADSim). Finally, following this method, we discover that a nontrivial relationship exists between the optimal SpecTAD parameter set and the number of CPU cores available at run-time. Furthermore, we find that a majority of the available SpecTAD boost can be achieved within an existing TAD application using relatively simple algorithm modifications.

97 MATHEMATICS AND COMPUTING↗