Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASMA ELECTRODE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Liquid-Metal-Fed Pulsed Plasma Thrusters

A short document proposes liquid-metal-fed pulsed plasma thrusters for small spacecraft. The propellant liquid for such a thruster would be a low-melting-temperature metal that would be stored molten in an unpressurized, heated reservoir and would be pumped to the thruster by a magnetohydrodynamic coupler. The liquid would enter the thruster via a metal tube inside an electrically insulating ceramic tube. A capacitor would be connected between the outlet of the metal tube and the outer electrode of the thruster. The pumping would cause a drop of liquid to form at the outlet, eventually growing large enough to make contact with the outer electrode. Contact would close the circuit through the capacitor, causing the capacitor to discharge through the drop. The capacitor would have been charged with enough energy that the discharge would vaporize, ionize, and electromagnetically accelerate the contents of the metal drop. The resulting plasma would be ejected at a speed of about 50 km/s. The vaporization of the drop would reopen the circuit through the capacitor, enabling recharging of the capacitor. As pumping continued, a new drop would grow and the process would repeat.

Markusic, Thomas↗

Ultracompact/ultralow power electron cyclotron resonance ion source for multipurpose applications

In order to drastically reduce the power consumption of a microwave ion source, we have studied some specific discharge cavity geometries in order to reduce the operating point below 1 W of microwave power (at 2.45 GHz). We show that it is possible to drive an electron cyclotron resonance ion source with a transmitter technology similar to those used for cellular phones. By the reduction in the size and of the required microwave power, we have developed a new type of ultralow cost ion sources. This microwave discharge system (called COMIC, for COmpact MIcrowave and Coaxial) can be used as a source of light, plasma or ions. We will show geometries of conductive cavities where it is possible, in a 20 mm diameter chamber, to reduce the ignition of the plasma below 100 mW and define typical operating points around 5 W. Inside a simple vacuum chamber it is easy to place the source and its extraction system anywhere and fully under vacuum. In that case, current densities from 0.1 to 10 mA/cm{sup 2} (Ar, extraction 4 mm, 1 mAe, 20 kV) have been observed. Preliminary measurements and calculations show the possibility, with a two electrodes system, to extract beams within a low emittance. The first application for these ion sources is the ion injection for charge breeding, surface analyzing system and surface treatment. For this purpose, a very small extraction hole is used (typically 3/10 mm for a 3 {mu}A extracted current with 2 W of HF power). Mass spectrum and emittance measurements will be presented. In these conditions, values down to 1 {pi} mm mrad at 15 kV (1{sigma}) are observed, thus very close to the ones currently observed for a surface ionization source. A major interest of this approach is the possibility to connect together several COMIC devices. We will introduce some new on-going developments such as sources for high voltage implantation platforms, fully quartz radioactive ion source at ISOLDE or large plasma generators for plasma immersion, broad or ribbon beams generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control of secondary electrons from ion beam impact using a positive potential electrode

Secondary electrons emitted when an ion beam impacts a detector can amplify the ion beam signal, but also introduce errors if electrons from one detector propagate to another. A potassium ion beam and a detector comprised of ten impact wires, four split-plates, and a pair of biased electrodes were used to demonstrate that a low-voltage, positive electrode can be used to maintain the beneficial amplification effect while greatly reducing the error introduced from the electrons traveling between detector elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma Panel Based Radiation Detectors

The plasma panel sensor (PPS) is a gaseous micropattern radiation detector under current development. It has many operational and fabrication principles common to plasma display panels (PDPs). It comprises a dense matrix of small, gas plasma discharge cells within a hermetically sealed panel. As in PDPs, it uses non-reactive, intrinsically radiation-hard materials such as glass substrates, refractory metal electrodes, and mostly inert gas mixtures. We are developing these devices primarily as thin, low-mass detectors with gas gaps from a few hundred microns to a few millimeters. The PPS is a high gain, inherently digital device with the potential for fast response times, fine position resolution (< 50 m RMS) and low cost. In this paper we report here on prototype PPS experimental results in detecting betas, protons and cosmic muons, and we extrapolate on the PPS potential for applications including detection of alphas, heavy-ions at low to medium energy, thermal neutrons and X-rays.

Friedman, Dr. Peter S.↗

Pseudo-spark switch (PSS) characteristics under different operation conditions

The present paper concentrates on the characteristics of the pseudospark switch (PSS) designed in a previous work. The special characteristics of PSS make it a replacement for other high voltage switches such as thyratrons and ordinary high-pressure spark gaps. PSS is characterized by short rise time and small jitter time. The pseudo park chamber consists of two hollow cylindrical electrodes made of a stainless steel material (type 306L) separated by an insulator. The insulator used in our design is a glazed ceramic 70 mm in diameter and 3.5 mm in thickness. A PSS with an anode voltage of 29.2 kV, and a current of 3.6 kA and 11 ns rise time was achieved and used successfully at a repetition rate of about 2.2 kHz. A simple trigger circuit designed, built, and used effectively reaching more than 1.56 kV trigger pulse which is sufficient to ignite the argon gas inside the cathode to cause a breakdown. A non-inductive dummy load is designed to be a new technique to find the accurate value of the PSS inductance. A jitter time of ±10 ns pulses is observed to occur in a reliable manner for more than 6 h of continuous operation. In this research, the important parameters of this switch like rise time, peak current, and anode voltage were studied at various values of charging capacitance. The lifetime of this system is depending on the kind of the electrode material and on the type of insulation material in the main gap of the pseudospark switch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging suprathermal x-rays from a laboratory plasma jet using PIN-diode-based and scintillator-based 1D pinhole/coded aperture cameras

A PIN-diode-based 1D x-ray camera and a scintillator-based 1D x-ray camera, both with a microsecond to submicrosecond time resolution, have been developed to perform time-resolved imaging of transient, low-intensity, suprathermal x-rays associated with magnetohydrodynamic instabilities disrupting a plasma jet. These cameras have a high detection efficiency over a broad x-ray band, a wide field of view, and the capability to produce >50 time-resolved frames with a ≤1 μs time resolution. The x-ray images are formed by a pinhole or by a coded aperture placed outside a vacuum chamber in which the plasma jet is launched. The 1D imaging shows that the location of the x-ray source is either a few centimeters away from an inner disk electrode or near a spatially translatable metal frame that is 30–40 cm away from the electrode. Compared to a pinhole, a coded aperture increases the signal collection efficiency but also introduces unwanted artifacts.

Instruments & Instrumentation↗

Low Temperature Formation of Carbonaceous Grains from Hydrocarbons and PAHs with the COSmIC Facility

Complex carbon molecules and ions are ubiquitous in space and form the building blocks of the carbonaceous components of cosmic dust grains, ultimately contributing to the formation of planets. We report experimental investigations of the low temperature chemical pathways leading to the formation of cosmic grain analogs from gas phase molecular precursors to better understand the evolution of cosmic carbon. The study of the formation of dust is essential to understand and to quantify the budget of extraterrestrial organic molecules. Although dust plays an important role in the evolution of interstellar chemistry and in the formation of organic molecules, little is known on the formation and destruction processes of carbonaceous dust. The experiments were performed using the Cosmic Simulation Chamber (COSmIC) to generate and characterize solid grains formed from gas phase precursors under controlled conditions representative of astrophysical environments [1]. Using COSmIC, it is possible to investigate the evolution of cosmic carbon from the formation of neutral and ionized hydrocarbons and PAHs in the gas phase [2], to solid carbon grains [3, 4, 5]. This is achieved by using a pulsed slit discharge nozzle to produce an adiabatic jet expansion and cool down Ar-hydrocarbon and PAH gas mixtures to astrophysically relevant temperature before inducing chemistry by generating a plasma discharge in the stream of the expansion. This plasma induced chemistry results in the formation of complex molecules and solid particles, analogs of cosmic grains in situ in the plasma expansion (i.e., without wall effects) that are carried by the accelerated gas in the expansion, and collected on substrates placed a few centimeters downstream of the electrodes. The results of a preliminary solid phase ex-situ analysis of cosmic grain analogs produced from a series of gas mixtures including hydrocarbons such as CH4 and C2H2 [3] and PAHs [4, 5] found in circumstellar ejecta of late C stars will be discussed. SEM imaging was used to provide insight on the impact of the precursors on the morphology and growth structure of the grains produced [3]. Laser desorption mass spectrometry was used to identify the molecules making up the main structures within the condensed grains [4] while X-ray irradiation and X-ray photoemission spectroscopy were used to investigate the impact the impact of stellar X-rays on cosmic dust.

Carbonaceous Grains↗

Electron density measurements and calculations in a helium capacitively-coupled radio-frequency plasma

We report a comparison of inferred electron density (n e ) in a He capacitively-coupled plasma, deduced from laser-collision induced fluorescence measurements, with values computed using a hybrid simulation framework based on particle-in-cell/Monte Carlo collisions simulations and a fluid model for excited He atoms. The studies were carried out for gas pressures between 50 mTorr and 1000 mTorr and peak-to-peak radio-frequency (13.56 MHz) voltages between 150 V and 350 V, in a highly symmetric source equipped with plane-parallel electrodes. A good agreement is found between the experimental and modeling results for n e except at the lowest operating voltages and gas pressures. The (effective) electron temperature (T e ) values derived by the two methods agree as well reasonably within the plasma bulk. The simulation results are used to compare the density distributions of He + and various He excited levels and their major populating and de-populating channels at 100 mTorr and 1000 mTorr.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Langmuir Probe and Mass Spectroscopic Measurements in Inductively Coupled CF4 Plasmas

Abstract Electron and ion energy distribution functions and other plasma parameters such as plasma potential (V(sub p)) , electron temperature (T(sub e)), and electron and ion number densities (n (sub e) and n(sub i)) in low pressure CF4 plasmas have been measured. The experiments were conducted in a GEC cell using an inductively coupled plasma (ICP) device powered by a 13.56 MHz radio-frequency (rf) power source. The measurements were made at 300 W of input rf power at 10, 30 and 50 mTorr gas pressures. Langmuir probe measurements suggest that n(sub e), n(sub i) and V(sub p) remain constant over 60% of the central electrode area, beyond which they decrease. Within the limits of experimental error (+/- 0.25 eV), T(sub e) remains nearly constant over the electrode area. T(sub e) and V(sub p) increase with a decrease in pressure. n(sub e) and n(sub i) are not affected as significantly as T(sub e) or V(sub p) by variation in the gas pressure. The electron energy distribution function (EEDF) measurements indicate a highly non-Maxwellian plasma. CF3+ is the most dominant ion product of the plasma, followed by CF2+ and CF+. The concentrations of CF2+ and CF+ are much larger than that is possible from direct electron impact ionization of the parent gas. The cross-section data suggest that the direct electron impact ionization of fragment neutrals and negative ion production by electron attachment may be responsible for increase of the minor ions.

Rao, M. V. V. S.↗

Model of a SNS Electrostatic LEBT with a Near-Ground Beam Chopper

The low energy beam transport (LEBT) of the Spallation Neutron Source (SNS) accelerator consists of two electrostatic lenses, of which the second is split into four electrically-isolated segments. Adding fast pulsed voltages to the lens high voltage creates the transverse fields required for beam chopping. Electric sparks, however, create transients that enter the fast high-voltage switches, which are occasionally damaged and cause machine downtime. This work models a new configuration of the electrostatic LEBT, which chops the beam with four shielded, near-ground electrodes between the two lenses. The model shows that the new configuration can match the RFQ injection requirements and sufficiently deflect the beam in the phase-space using the same chopping voltages as in the baseline LEBT.

43 PARTICLE ACCELERATORS↗

Dielectric Barrier Discharge Plasma Actuator for Flow Control

This report is Part II of the final report of NASA Cooperative Agreement contract no. NNX07AC02A. It includes a Ph.D. dissertation. The period of performance was January 1, 2007 to December 31, 2010. Part I of the final report is the overview published as NASA/CR-2012- 217654. Asymmetric dielectric barrier discharge (DBD) plasma actuators driven by nanosecond pulses superimposed on dc bias voltage are studied experimentally. This produces non-self-sustained discharge: the plasma is generated by repetitive short pulses, and the pushing of the gas occurs primarily due to the bias voltage. The parameters of ionizing pulses and the driving bias voltage can be varied independently, which adds flexibility to control and optimization of the actuators performance. The approach consisted of three elements coupled together: the Schlieren technique, burst mode of plasma actuator operation, and 2-D numerical fluid modeling. During the experiments, it was found that DBD performance is severely limited by surface charge accumulation on the dielectric. Several ways to mitigate the surface charge were found: using a reversing DC bias potential, three-electrode configuration, slightly conductive dielectrics, and semi conductive coatings. Force balance measurements proved the effectiveness of the suggested configurations and advantages of the new voltage profile (pulses+bias) over the traditional sinusoidal one at relatively low voltages. In view of practical applications certain questions have been also addressed, such as electrodynamic effects which accompany scaling of the actuators to real size models, and environmental effects of ozone production by the plasma actuators.

Opaits, Dmitry, F.↗

An integrated electrochemical device based on immunochromatographic test strip and enzyme labels for sensitive detection of disease-related biomarkers

A novel electrochemical biosensing device that integrates an immunochromatographic test strip and a screen-printed electrode (SPE) connected to a portable electrochemical analyzer was presented for rapid, sensitive, and quantitative detection of disease-related biomarker in human blood samples. The principle of the sensor is based on sandwich immunoreactions between a biomarker and a pair of its antibodies on the test strip, followed by highly sensitive square-wave voltammetry (SWV) detection. Horseradish peroxidase (HRP) was used as a signal reporter for electrochemical readout. Hepatitis B surface antigen (HBsAg) was employed as a model protein biomarker to demonstrate the analytical performance of the sensor in this study. Some critical parameters governing the performance of the sensor were investigated in detail. The sensor was further utilized to detect HBsAg in human plasma with an average recovery of 91.3%. In comparison, a colorimetric immunochromatographic test strip assay (ITSA) was also conducted. The result shows that the SWV detection in the electrochemical sensor is much more sensitive for the quantitative determination of HBsAg than the colorimetric detection, indicating that such a sensor is a promising platform for rapid and sensitive point-of-care testing/screening of disease-related biomarkers in a large population

59 BASIC BIOLOGICAL SCIENCES↗

Hydrogen Sensor via Plasma Techniques Development

Currently, NASA Kennedy Space Center’s Exploration Ground Systems (EGS) uses liquid hydrogen (LH 2 ) as fuel for launches and ensures hydrogen is no longer in the fill lines by sampling gas into a controlled environment. Then they use a catalytic sensor that detects when hydrogen interacts with oxygen. However, this procedure requires repeatedly backfilling and flushing with helium, which can be wasteful during a global helium shortage and expensive for each sampling port. Therefore, the team at KSC set out to establish proof-of-concept of a plasma-based hydrogen sensor that is anaerobic – and can in fact detect in most environments and below atmospheric pressures – and with a small footprint and more sensitive than other hydrogen sensors currently on the market. The technology development was done by testing known concentrations of hydrogen in argon gas fed through a vacuum cube containing an electrode feedthrough at varying pressures. The resultant emission spectra were recorded with a fiber optic spectrometer and analyzed to determine the instrument's accuracy. Throughout testing, efforts were made to prove the off-the-shelf capabilities of the setup. The traditional high voltage AC-power source was switched to an affordable, handheld plasma lighter. Additionally, the spectrometer was supplemented with a double photodiode circuit to take targeted measurements of the Balmer-α and - β lines in the hydrogen spectrum. From this, we established a proof of concept sensor. SLS required it to detect as low as 100 ppm whereas we detected hydrogen in concentrations as low as 50 ppm and in an anaerobic environment. * Work supported by NASA Kennedy Space Center’s Science Mission Directorate Innovative Research and Development Fund.

Plasma↗

Hydrogen Sensor via Plasma Techniques Development

Currently, NASA Kennedy Space Center’s Exploration Ground Systems (EGS) uses liquid hydrogen (LH2) as fuel for launches and ensures hydrogen is no longer in the fill lines by sampling gas into a controlled environment. Then they use a catalytic sensor that detects when hydrogen interacts with oxygen. However, this procedure requires repeatedly backfilling and flushing with helium, which can be wasteful during a global helium shortage and expensive for each sampling port. Therefore, the team at KSC set out to establish proof-of-concept of a plasma-based hydrogen sensor that is anaerobic – and can in fact detect in most environments and below atmospheric pressures – and with a small footprint and more sensitive than other hydrogen sensors currently on the market. The technology development was done by testing known concentrations of hydrogen in argon gas fed through a vacuum cube containing an electrode feedthrough at varying pressures. The resultant emission spectra were recorded with a fiber optic spectrometer and analyzed to determine the instrument's accuracy. Throughout testing, efforts were made to prove the off-the-shelf capabilities of the setup. The traditional high voltage AC-power source was switched to an affordable, handheld plasma lighter. Additionally, the spectrometer was supplemented with a double photodiode circuit to take targeted measurements of the Balmer-α and - β lines in the hydrogen spectrum. From this, we established a proof of concept sensor. SLS required it to detect as low as 100 ppm whereas we detected hydrogen in concentrations as low as 50 ppm and in an anaerobic environment.

plasma↗

Experimental study of high-energy single-pulse nanosecond discharges in pin-to-pin configuration

Single-pulse pin-to-pin nanosecond pulsed discharges in ambient air (gap distances of 3–7 mm) were investigated at high pulse energies (∼20–30 mJ deposited energy per 11 ns full width at half maximum pulse). A Michelson interferometry setup (532 nm continuous-wave laser) was employed to record time-resolved interferograms of the discharge, enabling spatially resolved calculation of the electron number density. An intensified charge-coupled device camera was used to capture the spatiotemporal evolution of the discharge (streamer formation and spark channel development), and Coherent Anti-Stokes Raman Spectroscopy (CARS) was used to measure post-discharge N 2 vibrational temperatures. Discharge current and voltage were monitored with a back-current shunt. The discharge was initiated with simultaneous cathode-directed and anode-directed streamers that bridge the gap within ∼1 ns and form a luminous, filamentary plasma channel immediately after breakdown. Laser interferometry measurements showed peak electron number densities of the order of 10 1 7–10 18 cm −3 , occurring about 15–20 ns after pulse arrival at the discharge gap. Shorter gap discharges yielded higher peak electron densities, consistent with the higher energy density in the smaller gaps. Spatially, the electron density was highest near the electrodes and decreased toward the midgap region, with 5 and 7 mm gaps exhibiting a pronounced drop in the central channel. CARS indicated initial vibrational temperatures of approximately 4000–6000 K in the spark core of ∼50 ns after the discharge onset, decaying on a ∼500 ns timescale as the plasma cooled and recombined.

Coherent anti-Stokes Raman spectroscopy↗

Functionalized Graphene Oxide as a Nanocarrier in a Multienzyme Labeling Amplification Strategy for Ultrasensitive Electrochemical Immunoassay of Phosphorylated p53 (S392)

P53 phosphorylation plays an important role in many biological processes and might be used as a potential biomarker in clinical diagnoses. We report a new electrochemical immunosensor for ultrasensitive detection of phosphorylated p53 at Ser392 (phospho-p53-392) based on graphene oxide (GO) as a nanocarrier in multienzymes amplification strategy. Greatly enhanced sensitivity was achieved by using the bioconjugates featuring horseradish peroxidase (HRP) and p53392 signal antibody (p53Ab2) linked to functionalized GO (HRP-p53Ab2-GO) at high ratio of HRP/p53Ab2. After a sandwich immunoreaction, the HRP-p53Ab2-GO captured onto the electrode surface produced an amplified electrocatalytic response by the reduction of enzymatically oxidized thionine in the presence of hydrogen peroxide. The increase of response current was proportional to the phospho-p53 concentration in the range of 0.02 to 2 nM with the detection limit of 0.01 nM, which was 10-fold lower than that of traditional sandwich electrochemical measurement for p53. The amplified immunoassay developed in this work shows acceptable stability and reproducibility and the assay results for phospho-p53 spiked in human plasma also show good recovery (92%~103.8%). This simple and low-cost immunosensor shows great promise for detection of other phosphorylated proteins and clinical applications.

59 BASIC BIOLOGICAL SCIENCES↗

Multimegawatt MPD thruster design considerations

Performance and lifetime requirements for multimegawatt magnetoplasmadynamic (MPD) thrusters were used to establish a baseline 2.5 MW thruster design. The chamber surface power deposition resulting from current conduction, plasma and surface radiation, and conduction from the hot plasma was then evaluated to establish the feasibility of thruster operation. It was determined that state of the art lithium heat pipes were adequate to cool the anode electrode, and that the liquid hydrogen propellant could be used to cool the applied field magnet, cathode, and backplate. Unresolved issues having an impact of thruster design are discussed to help focus future research.

Myers, Roger M.↗