Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PALLADIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Excited states in {sup 115}Pd populated in the {beta}{sup -} decay of {sup 115}Rh

Excited states in {sup 115}Pd, populated following the {beta}{sup -} decay of {sup 115}Rh have been studied by means of {gamma} spectroscopy after the Penning-trap station at the IGISOL facility, University of Jyvaeskylae. The 1/2{sup +} spin and parity assignment of the ground state of {sup 115}Pd, confirmed in this work, may indicate a transition to an oblate shape in Pd isotopes at high neutron number.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation of a new high-spin isomer in {sup 94}Pd

A second {gamma}-decaying high-spin isomeric state, with a half-life of 197(22)ns, has been identified in the N=Z+2 nuclide {sup 94}Pd as part of a stopped-beam Rare Isotope Spectroscopic INvestigation at GSI (RISING) experiment. Weisskopf estimates were used to establish a tentative spin/parity of 19{sup -}, corresponding to the maximum possible spin of a negative parity state in the restricted (p{sub 1/2}, g{sub 9/2}) model space of empirical shell model calculations. The reproduction of the E3 decay properties of the isomer required an extension of the model space to include the f{sub 5/2} and p{sub 3/2} orbitals using the CD-Bonn potential. This is the first time that such an extension has been required for a high-spin isomer in the vicinity of {sup 100}Sn and reveals the importance of such orbits for understanding the decay properties of high-spin isomers in this region. However, despite the need for the extended model space for the E3 decay, the dominant configuration for the 19{sup -} state remains ({pi}p{sub 1/2}{sup -1}g{sub 9/2}{sup -3}){sub 11} x ({nu}g{sub 9/2}{sup -2}){sub 8}. The half-life of the known, 14{sup +}, isomer was remeasured and yielded a value of 499(13) ns.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

g factors of the low-lying states in {sup 106}Pd: Examination of the vibrational character of {sup 106}Pd

The transient field (TF) technique in inverse kinematics was used to measure the g factors of the low lying 2{sub 1}{sup +}, 4{sub 1}{sup +}, and 2{sub 2}{sup +} states in {sup 106}Pd. The g factor of the 4{sub 1}{sup +} state was determined and the g(2{sub 1}{sup +}) and g(2{sub 2}{sup +}) factors were remeasured. The values of g(2{sub 1}{sup +}) and g(2{sub 2}{sup +}) had been determined earlier in integral perturbed angular correlation (IPAC) experiments and the value of the former served to calibrate the TF. The three g factors, g(2{sub 1}{sup +}), g(2{sub 2}{sup +}), and g(4{sub 1}{sup +}), agree with each other and with the collective Z/A value. The uncertainties in the g(2{sub 2}{sup +}) and g(4{sub 1}{sup +}) factors remain fairly large in spite of long measuring times because of the weak excitation of the two-phonon states. The lifetimes of the 2{sub 2}{sup +} and 4{sub 1}{sup +} states were newly determined from line-shape fits.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainties in nuclear transition matrix elements for neutrinoless {beta}{beta} decay within the projected-Hartree-Fock-Bogoliubov model

The nuclear transition matrix elements M{sup (0{nu})} for the neutrinoless {beta}{beta} decay of {sup 94,96}Zr, {sup 98,100}Mo, {sup 104}Ru, {sup 110}Pd, {sup 128,130}Te, and {sup 150}Nd isotopes in the case of 0{sup +}{yields}0{sup +} transition are calculated using the projected-Hartree-Fock-Bogoliubov wave functions, which are eigenvectors of four different parametrizations of a Hamiltonian with pairing plus multipolar effective two-body interaction. Employing two (three) different parametrizations of Jastrow-type short-range correlations, a set of eight (twelve) different nuclear transition matrix elements M{sup (0{nu})} is built for each decay, whose averages in conjunction with their standard deviations provide an estimate of the model's uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Excited states in {sup 99}Pd

Excited states in the {sup 99}Pd nucleus populated in the {sup 75}As({sup 28}Si, p3n) fusion-evaporation reaction at E{sub lab}=120 MeV have been investigated through in-beam {gamma}-ray spectroscopic techniques using an array of Compton-suppressed clover detectors. The level scheme is established up to excitation energy {approx}11.5 MeV and spin {approx}25({h_bar}/2{pi}) with the addition of about 60 new transitions. The level structures observed in {sup 99}Pd have been interpreted in the framework of a microscopic theory based on the deformed Hartree-Fock and angular momentum projection techniques. Band structures at lower spins are based on the low-{Omega} {nu}g{sub 7/2} and {nu}d{sub 5/2} orbitals, and those at higher spins are reproduced for the {pi}(g{sub 9/2}){sup 5} x {pi}(g{sub 7/2}) x {nu}(g{sub 7/2}){sup 2} x {nu}(h{sub 11/2}){sup 2} x {nu}(g{sub 9/2}){sup -1} and {pi}(g{sub 9/2}){sup 6} x {nu}(g{sub 9/2}){sup 10} x {nu}(g{sub 7/2}){sup 2} x {nu}(h{sub 11/2}) configurations. The octupole correlations in {sup 99}Pd have been inferred from new interband E1 transitions linking the {Delta}I=1 states of the bands based on the {nu}h{sub 11/2} and {nu}d{sub 5/2} orbitals ({Delta}l=3, {Delta}j=3, and {Delta}{pi}=-1) with the deduced B(E1) values {approx}10{sup -6} W.u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spin-aligned neutron-proton pairs in N=Z nuclei

A study is carried out on the role of the aligned neutron-proton pair with angular momentum J=9 and isospin T=0 in the low-energy spectroscopy of the N=Z nuclei {sup 96}Cd, {sup 94}Ag, and {sup 92}Pd. Shell-model wave functions resulting from realistic interactions are analyzed in terms of a variety of two-nucleon pairs corresponding to different choices of their coupled angular momentum J and isospin T. The analysis is performed exactly for four holes ({sup 96}Cd) and carried further for six and eight holes ({sup 94}Ag and {sup 92}Pd) by means of a mapping to an appropriate version of the interacting boson model. The study allows the identification of the strengths and deficiencies of the aligned-pair approximation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spin-aligned neutron-proton pair mode in atomic nuclei

Shell-model calculations using realistic interactions reveal that the ground and low-lying yrast states of the N=Z nucleus {sub 46}{sup 92}Pd are mainly built upon isoscalar neutron-proton pairs, each carrying the maximum angular momentum J=9 allowed by the shell 0g{sub 9/2}, which is dominant in this nuclear region. This structure is different from that found in the ground and low-lying yrast states of all other even-even nuclei studied so far. The low-lying spectrum of excited states generated by such correlated neutron-proton pairs has two distinctive features: (i) the levels are almost equidistant at low energies and (ii) the transition probability I{yields}I-2 is approximately constant and strongly selective. This unique mode is shown to replace normal isovector pairing as the dominant coupling scheme in N=Z nuclei approaching the doubly magic nucleus {sup 100}Sn.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass Measurements and Implications for the Energy of the High-Spin Isomer in {sup 94}Ag

Nuclides in the vicinity of {sup 94}Ag have been studied with the Penning trap mass spectrometer JYFLTRAP at the Ion-Guide Isotope Separator On-Line. The masses of the two-proton-decay daughter {sup 92}Rh and the beta-decay daughter {sup 94}Pd of the high-spin isomer in {sup 94}Ag have been measured, and the masses of {sup 93}Pd and {sup 94}Ag have been deduced. When combined with the data from the one-proton- or two-proton-decay experiments, the results lead to contradictory mass excess values for the high-spin isomer in {sup 94}Ag, -46 370(170) or -44 970(100) keV, corresponding to excitation energies of 6960(400) or 8360(370) keV, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Formation of Pd nanocrystals in titanium-oxide film by rapid thermal annealing of reactively cosputtered TiPdO films

In this article, the authors report a novel method for preparation of Pd nanocrystals embedded in TiO{sub 2} film; i.e., the TiPdO films are first deposited by reactively cosputtering Ti and Pd targets in a plasma mixture of O{sub 2} and Ar, followed by rapid thermal annealing (RTA). The experimental results indicate that the TiPdO film with a high content of Pd is inclined to produce big nanocrystals. Furthermore, the higher the RTA temperature, the bigger the Pd nanocrystals become. In addition, our analyses of the x-ray photoelectron spectroscopy spectra reveal that PdO, PdO{sub 2}, Ti{sub 2}O{sub 3}, and TiO{sub 2} coexist in the as-deposited film, and the RTA at 600 deg. C leads to decomposition of the entire PdO{sub 2} and partial PdO, together with the growth of Pd nanocrystals. At the same time, the released oxygen oxidizes fully Ti{sub 2}O{sub 3} into TiO{sub 2} during the decomposition. As the RTA temperature is increased up to 900 deg. C, more and more PdO is decomposed and the Pd nanocrystals become bigger and bigger.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Primary calibration of coiled {sup 103}Pd brachytherapy sources

Coiled {sup 103}Pd brachytherapy sources have been developed by RadioMed Corporation for use as low-dose-rate (LDR) interstitial implants. The coiled sources are provided in integer lengths from 1 to 6 cm and address many common issues seen with traditional LDR brachytherapy sources. The current standard for determining the air-kerma strength (S{sub K}) of low-energy LDR brachytherapy sources is the National Institute of Standards and Technology's Wide-Angle Free-Air Chamber (NIST WAFAC). Due to geometric limitations, however, the NIST WAFAC is unable to determine the S{sub K} of sources longer than 1 cm. This project utilized the University of Wisconsin's Variable-Aperture Free-Air Chamber (UW VAFAC) to determine the S{sub K} of the longer coiled sources. The UW VAFAC has shown agreement in S{sub K} values of 1 cm length coils to within 1% of those determined with the NIST WAFAC, but the UW VAFAC does not share the same geometric limitations as the NIST WAFAC. A new source holder was constructed to hold the coiled sources in place during measurements with the UW VAFAC. Correction factors for the increased length of the sources have been determined and applied to the measurements. Using the new source holder and corrections, the S{sub K} of 3 and 6 cm coiled sources has been determined. Corrected UW VAFAC data and ionization current measurements from well chambers have been used to determine calibration coefficients for use in the measurement of 3 and 6 cm coiled sources in well chambers. Thus, the UW VAFAC has provided the first transferable, primary measurement of low-energy LDR brachytherapy sources with lengths greater than 1 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monte Carlo calculations and experimental measurements of dosimetric parameters of the IRA-{sup 103}Pd brachytherapy source

This article presents a brachytherapy source having {sup 103}Pd adsorbed onto a cylindrical silver rod that has been developed by the Agricultural, Medical, and Industrial Research School for permanent implant applications. Dosimetric characteristics (radial dose function, anisotropy function, and anisotropy factor) of this source were experimentally and theoretically determined in terms of the updated AAPM Task group 43 (TG-43U1) recommendations. Monte Carlo simulations were used to calculate the dose rate constant. Measurements were performed using TLD-GR200A circular chip dosimeters using standard methods employing thermoluminescent dosimeters in a Perspex phantom. Precision machined bores in the phantom located the dosimeters and the source in a reproducible fixed geometry, providing for transverse-axis and angular dose profiles over a range of distances from 0.5 to 5 cm. The Monte Carlo N-particle (MCNP) code, version 4C simulation techniques have been used to evaluate the dose-rate distributions around this model {sup 103}Pd source in water and Perspex phantoms. The Monte Carlo calculated dose rate constant of the IRA-{sup 103}Pd source in water was found to be 0.678 cGy h{sup -1} U{sup -1} with an approximate uncertainty of {+-}0.1%. The anisotropy function, F(r,{theta}), and the radial dose function, g(r), of the IRA-{sup 103}Pd source were also measured in a Perspex phantom and calculated in both Perspex and liquid water phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of the dose distribution for prostate implants using various {sup 125}I and {sup 103}Pd sources

Recently, several different models of {sup 125}I and {sup 103}Pd brachytherapy sources have been introduced in order to meet the increasing demand for prostate seed implants. These sources have different internal structures; hence, their TG-43 dosimetric parameters are not the same. In this study, the effects of the dosimetric differences among the sources on their clinical applications were evaluated. The quantitative and qualitative evaluations were performed by comparisons of dose distributions and dose volume histograms of prostate implants calculated for various designs of {sup 125}I and {sup 103}Pd sources. These comparisons were made for an identical implant scheme with the same number of seeds for each source. The results were compared with the Amersham model 6711 seed for {sup 125}I and the Theragenics model 200 seed for {sup 103}Pd using the same implant scheme.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 103}Pd strings: Monte Carlo assessment of a new approach to brachytherapy source design

Purpose: A new type of{sup 103}Pd source (CivaString and CivaThin by CivaTech Oncology, Inc.) is examined. The source contains {sup 103}Pd and Au radio-opaque marker(s), all contained within low-Z{sub eff} organic polymers that permit source flexibility. The CivaString source is available in lengths L of 10, 20, 30, 40, 50, and 60 mm, and referred to in the current study as CS10–CS60, respectively. A thinner design, CivaThin, has sources designated as CT10–CT60, respectively. The CivaString and CivaThin sources are 0.85 and 0.60 mm in diameter, respectively. The source design is novel and offers an opportunity to examine its interesting dosimetric properties in comparison to conventional {sup 103}Pd seeds. Methods: The MCNP5 radiation transport code was used to estimate air-kerma rate and dose rate distributions with polar and cylindrical coordinate systems. Doses in water and prostate tissue phantoms were compared to determine differences between the TG-43 formalism and realistic clinical circumstances. The influence of Ti encapsulation and 2.7 keV photons was examined. The accuracy of superposition of dose distributions from shorter sources to create longer source dose distributions was also assessed. Results: The normalized air-kerma rate was not highly dependent onL or the polar angle θ, with results being nearly identical between the CivaString and CivaThin sources for common L. The air-kerma strength was also weakly dependent on L. The uncertainty analysis established a standard uncertainty of 1.3% for the dose-rate constant Λ, where the largest contributors were μ{sub en}/ρ and μ/ρ. The Λ values decreased with increasing L, which was largely explained by differences in solid angle. The radial dose function did not substantially vary among the CivaString and CivaThin sources for r ≥ 1 cm. However, behavior for r < 1 cm indicated that the Au marker(s) shielded radiation for the sources having L = 10, 30, and 50 mm. The 2D anisotropy function exhibited peaks and valleys that corresponded to positions adjacent to {sup 103}Pd wells and Au markers, respectively. Dose distributions of both source types had minimal anisotropy in comparison to conventional {sup 103}Pd seeds. Contributions by 2.7 keV photons comprised ≤0.1% of the dose from all photons at positions farther than 0.13 mm from the polymer source surface. Differences between absorbed dose to water and prostate became more substantial as distance from the sources increased, with prostate dose being about 13% lower for r = 5 cm. Using a cylindrical coordinate system, dose superposition of small length sources to replicate the dose distribution for a long length source proved to be a robust technique; a 2.0% tolerance compared with the reference dose distribution did not exceed 0.1 cm{sup 3} for any of the examined source combinations. Conclusions: By design, the CivaString and CivaThin sources have novel dosimetric characteristics in comparison to Ti-encapsulated{sup 103}Pd seeds. The dosimetric characterization has determined the reasons for these differences through analysis using Monte Carlo-based radiation transport simulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of prescription dose for Cs-131 permanent implants using the BED formalism including resensitization correction

Purpose: The current widely used biological equivalent dose (BED) formalism for permanent implants is based on the linear-quadratic model that includes cell repair and repopulation but not resensitization (redistribution and reoxygenation). The authors propose a BED formalism that includes all the four biological effects (4Rs), and the authors propose how it can be used to calculate appropriate prescription doses for permanent implants with Cs-131. Methods: A resensitization correction was added to the BED calculation for permanent implants to account for 4Rs. Using the same BED, the prescription doses with Au-198, I-125, and Pd-103 were converted to the isoeffective Cs-131 prescription doses. The conversion factor F, ratio of the Cs-131 dose to the equivalent dose with the other reference isotope (F{sub r}: with resensitization, F{sub n}: without resensitization), was thus derived and used for actual prescription. Different values of biological parameters such as α, β, and relative biological effectiveness for different types of tumors were used for the calculation. Results: Prescription doses with I-125, Pd-103, and Au-198 ranging from 10 to 160 Gy were converted into prescription doses with Cs-131. The difference in dose conversion factors with (F{sub r}) and without (F{sub n}) resensitization was significant but varied with different isotopes and different types of tumors. The conversion factors also varied with different doses. For I-125, the average values of F{sub r}/F{sub n} were 0.51/0.46, for fast growing tumors, and 0.88/0.77 for slow growing tumors. For Pd-103, the average values of F{sub r}/F{sub n} were 1.25/1.15 for fast growing tumors, and 1.28/1.22 for slow growing tumors. For Au-198, the average values of F{sub r}/F{sub n} were 1.08/1.25 for fast growing tumors, and 1.00/1.06 for slow growing tumors. Using the biological parameters for the HeLa/C4-I cells, the averaged value of F{sub r} was 1.07/1.11 (rounded to 1.1), and the averaged value of F{sub n} was 1.75/1.18. F{sub r} of 1.1 has been applied to gynecological cancer implants with expected acute reactions and outcomes as expected based on extensive experience with permanent implants. The calculation also gave the average Cs-131 dose of 126 Gy converted from the I-125 dose of 144 Gy for prostate implants. Conclusions: Inclusion of an allowance for resensitization led to significant dose corrections for Cs-131 permanent implants, and should be applied to prescription dose calculation. The adjustment of the Cs-131 prescription doses with resensitization correction for gynecological permanent implants was consistent with clinical experience and observations. However, the Cs-131 prescription doses converted from other implant doses can be further adjusted based on new experimental results, clinical observations, and clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model-based dose calculations for COMS eye plaque brachytherapy using an anatomically realistic eye phantom

Purpose : To investigate the effects of the composition and geometry of ocular media and tissues surrounding the eye on dose distributions for COMS eye plaque brachytherapy with{sup 125}I, {sup 103}Pd, or {sup 131}Cs seeds, and to investigate doses to ocular structures. Methods : An anatomically and compositionally realistic voxelized eye model with a medial tumor is developed based on a literature review. Mass energy absorption and attenuation coefficients for ocular media are calculated. Radiation transport and dose deposition are simulated using the EGSnrc Monte Carlo user-code BrachyDose for a fully loaded COMS eye plaque within a water phantom and our full eye model for the three radionuclides. A TG-43 simulation with the same seed configuration in a water phantom neglecting the plaque and interseed effects is also performed. The impact on dose distributions of varying tumor position, as well as tumor and surrounding tissue media is investigated. Each simulation and radionuclide is compared using isodose contours, dose volume histograms for the lens and tumor, maximum, minimum, and average doses to structures of interest, and doses to voxels of interest within the eye. Results : Mass energy absorption and attenuation coefficients of the ocular media differ from those of water by as much as 12% within the 20–30 keV photon energy range. For all radionuclides studied, average doses to the tumor and lens regions in the full eye model differ from those for the plaque in water by 8%–10% and 13%–14%, respectively; the average doses to the tumor and lens regions differ between the full eye model and the TG-43 simulation by 2%–17% and 29%–34%, respectively. Replacing the surrounding tissues in the eye model with water increases the maximum and average doses to the lens by 2% and 3%, respectively. Substituting the tumor medium in the eye model for water, soft tissue, or an alternate melanoma composition affects tumor dose compared to the default eye model simulation by up to 16%. In the full eye model simulations, the average dose to the lens is larger by 7%–9% than the dose to the center of the lens, and the maximum dose to the optic nerve is 17%–22% higher than the dose to the optic disk for all radionuclides. In general, when normalized to the same prescription dose at the tumor apex, doses delivered to all structures of interest in the full eye model are lowest for{sup 103}Pd and highest for {sup 131}Cs, except for the tumor where the average dose is highest for {sup 103}Pd and lowest for {sup 131}Cs. Conclusions : The eye is not radiologically water-equivalent, as doses from simulations of the plaque in the full eye model differ considerably from doses for the plaque in a water phantom and from simulated TG-43 calculated doses. This demonstrates the importance of model-based dose calculations for eye plaque brachytherapy, for which accurate elemental compositions of ocular media are necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Secondary particle emission from a ferromagnetic binary compound

Secondary ion emission from an ion-bombarded binary compound in the ferro- and paramagnetic states has been studied using experimental methods and molecular dynamics simulations. The experiments were performed with a widely used NiPd binary compound, which was bombarded by obliquely incident 10-keV Ar ions. It is established that the intensity of Ni{sup +} and Pd{sup +} ion emission from a polycrystalline NiPd sample decreases significantly when it passes from the ferromagnetic to paramagnetic state. This effect is explained by a change in the surface binding energy and density of surface states at the Fermi level and by a cumulative process related to sputtering. The energies and directions of emission of secondary particles from poly- and single-crystalline NiPd samples in the ferromagnetic state have been jointly studied. It is established that the maximum of the polar angular distribution of secondary particles deviates toward the normal to the irradiated surface with a decrease in their energy. A difference in the azimuthal distribution of emitted Ni and Pd particles has been observed during the bombardment of a (001)NiPd crystal face and explained by specific features of correlated collisions. The best agreement of experimental data with the results of molecular dynamics simulations is obtained if the calculations are performed with allowance for an experimentally established modified composition of the three uppermost surface layers [39].

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Carbide-Modified Pd on ZrO2 as Active Phase for CO2-Reforming of Methane—A Model Phase Boundary Approach

Starting from subsurface Zr0-doped “inverse” Pd and bulk-intermetallic Pd0Zr0 model catalyst precursors, we investigated the dry reforming reaction of methane (DRM) using synchrotron-based near ambient pressure in-situ X-ray photoelectron spectroscopy (NAP-XPS), in-situ X-ray diffraction and catalytic testing in an ultrahigh-vacuum-compatible recirculating batch reactor cell. Both intermetallic precursors develop a Pd0–ZrO2 phase boundary under realistic DRM conditions, whereby the oxidative segregation of ZrO2 from bulk intermetallic PdxZry leads to a highly active composite layer of carbide-modified Pd0 metal nanoparticles in contact with tetragonal ZrO2. This active state exhibits reaction rates exceeding those of a conventional supported Pd–ZrO2 reference catalyst and its high activity is unambiguously linked to the fast conversion of the highly reactive carbidic/dissolved C-species inside Pd0 toward CO at the Pd/ZrO2 phase boundary, which serves the role of providing efficient CO2 activation sites. In contrast, the near-surface intermetallic precursor decomposes toward ZrO2 islands at the surface of a quasi-infinite Pd0 metal bulk. Strongly delayed Pd carbide accumulation and thus carbon resegregation under reaction conditions leads to a much less active interfacial ZrO2–Pd0 state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗