Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NET ENERGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Biophysical Impact of Land-Use and Land-Cover Change on Subgrid Temperature in CMIP6 Models

In this study, we investigate the air temperature response to land-use and land-cover change (LULCC; cropland expansion and deforestation) using subgrid land model output generated by a set of CMIP6 model simulations. Our study is motivated by the fact that ongoing land-use activities are occurring at local scales, typically significantly smaller than the resolvable scale of a grid cell in Earth system models. It aims to explore the potential for a multimodel approach to better characterize LULCC local climatic effects. On an annual scale, the CMIP6 models are in general agreement that croplands are warmer than primary and secondary land (psl; mainly forests, grasslands, and bare ground) in the tropics and cooler in the mid–high latitudes, except for one model. The transition from warming to cooling occurs at approximately 40°N. Although the surface heating potential, which combines albedo and latent heat flux effects, can explain reasonably well the zonal mean latitudinal subgrid temperature variations between crop and psl tiles in the historical simulations, it does not provide a good prediction on subgrid temperature for other land tile configurations (crop vs forest; grass vs forest) under Shared Socioeconomic Pathway 5–8.5 (SSP5–8.5) forcing scenarios. A subset of simulations with the CESM2 model reveals that latitudinal subgrid temperature variation is positively related to variation in net surface shortwave radiation and negatively related to variation in the surface energy redistribution factor, with a dominant role from the latter south of 30°N. We suggest that this emergent relationship can be used to benchmark the performance of land surface parameterizations and for prediction of local temperature response to LULCC.

54 ENVIRONMENTAL SCIENCES↗

Relative Economic Merits of Storage and Combustion Turbines for Meeting Peak Capacity Requirements under Increased Penetration of Solar Photovoltaics

Batteries with several hours of capacity provide an alternative to combustion turbines for meeting peak capacity requirements. Even when compared to state-of-the-art highly flexible combustion turbines, batteries can provide a greater operational value, which is reflected in a lower system-wide production cost. By shifting load and providing operating reserves, batteries can reduce the cost of operating the power system to a traditional electric utility. This added value means that, depending on battery life, batteries can have a higher cost than a combustion turbine of equal capacity and still produce a system with equal or lower overall life-cycle cost. For a utility considering investing in new capacity, the cost premium for batteries is highly sensitive to a variety of factors, including lifetime, natural gas costs, PV penetration, and grid generation mix. In addition, as PV penetration increases, the net electricity demand profile changes, which may reduce the amount of battery energy capacity needed to reliably meet peak demand.

14 SOLAR ENERGY↗

Value Streams in Microgrids: A literature Review

Microgrids are an increasingly common component of the evolving electricity grids with the potential to improve local reliability, reduce costs, and increase penetration rates for distributed renewable generation. The additional complexity of microgrids often leads to increased investment costs, creating a barrier for widespread adoption. These costs may result directly from specific needs for islanding detection, protection systems and power quality assurance that would otherwise be avoided in simpler system configurations. However, microgrids also facilitate additional value streams that may make up for their increased costs and improve the economic viability of microgrid deployment. This paper analyses the literature currently available on research relevant to value streams occurring in microgrids that may contribute to offset the increased investment costs. A review on research related to specific microgrid requirements is also presented.

25 ENERGY STORAGE↗

Placing Limits on the Higgs Production Cross Section at the Tevatron using the H → W + W - → ℓ + ℓ - Decay Channel

Limits on the Higgs production cross section at the Tevatron were placed using data with an integrated luminosity of 2.4 fb -1 from CDF. Limits over a Higgs mass range between 110 GeV and 200 GeV were determined, by calculating a limit at ten mass points distributed over this region. The analysis exclusively searches for Higgs produced by top-quark mediated gluon fusion and then decaying into two W bosons. Only leptonic decay channels of the W are considered, such that the final event signature consists of ee, eµ, or µµ with missing energy from undetected neutrinos. After an evaluation of alternative techniques, a neural net was selected as the best method for increasing the sensitivity of the measurement. The BFGS neural net training technique was selected as the most efficient method. A Bayesian Likelihood technique was used to place limits on the observed Higgs production cross section, and an expected limit was calculated by running 10,000 pseudo experiments. The 160 GeV mass point was the most most sensitive, achieving an expected limit 4.1 times the Standard Model prediction cross section at a 95% Confidence Level. Observed limits are within 1 σ of the expected limit below a mass point of ii 160 GeV. Above this, observed limits are higher than the expected limits, within 2 σ. The lowest observed limit was also at MH =160 GeV with a limit of 6.85 times the Standard Model prediction at a 95% Confidence Level. A new method for increasing the sensitivity of the measurement was proposed and investigated, but unused in the analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Integrated Paradigm for the Management of Delivery Risk in Electricity Markets: From Batteries to Insurance and Beyond

If power systems transition to integrate higher amounts of variable renewable energy sources, storage technologies, and distributed energy resources (DERs), new risk management frameworks are necessary to ensure cost-effective and reliable power system operations. Projects funded by the Advanced Research Projects Agency-Energy (ARPA-E) Performance-based Energy Resource Feedback, Optimization, and Risk Management (PERFORM) program aim to contribute new risk management frameworks by developing methods to quantify and manage risk at grid asset and system levels. The National Renewable Energy Laboratory (NREL) led a PERFORM project in collaboration with the Johns Hopkins University, the Electric Power Research Institute (EPRI), kWh Analytics, Packetized Energy, and Imperial Consultants (ICON). The project addressed two challenges related to risk management in electricity markets: managing net load imbalances and flexibility from DERs. This final technical report presents a list of project accomplishments, activities, and outputs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of Residential GSHP System

This report first briefly reviews geothermal heat pump (GHP) technology and the current status of the GHP industry in the United States. Then it assesses the potential national benefits, in terms of energy savings, reduced summer peak electrical demand, consumer energy cost savings, and reduced CO{sub 2} emissions from retrofitting the space heating, space cooling, and water heating systems in existing U.S. single-family homes with state-of-the-art GHP systems. The investment for retrofitting typical U.S. single-family homes with state-of-the-art GHP systems is also analyzed using the metrics of net present value and levelized cost.

15 GEOTHERMAL ENERGY↗

Status of Net Metering: Assessing the Potential to Reach Program Caps (Poster)

Several states are addressing the issue of net metering program caps, which limit the total amount of net metered generating capacity that can be installed in a state or utility service territory. In this analysis, we examine net metering caps to gain perspective on how long net metering will be available in various jurisdictions under current policies. We also surveyed state practices and experience to understand important policy design considerations.

14 SOLAR ENERGY↗

The Energy Spectrum of Atmospheric Neutrinos between 2 and 200 TeV with the AMANDA-II Detector

The muon and anti-muon neutrino energy spectrum is determined from 2000-2003 AMANDA telescope data using regularised unfolding. This is the first measurement of atmospheric neutrinos in the energy range 2-200 TeV. The result is compared to different atmospheric neutrino models and it is compatible with the atmospheric neutrinos from pion and kaon decays. No significant contribution from charm hadron decays or extraterrestrial neutrinos is detected. The capabilities to improve the measurement of the neutrino spectrum with the successor experiment IceCube are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Dataset for Blueprinting Electrified Transit System Implementation

This dataset contains the figures and tabulated results generated from a system-level optimization study of transit fleet electrification planning. The dataset does not include executable modeling code required to reproduce the optimization. The dataset includes results for optimized charging infrastructure deployment by location and power level and service block assignments by fuel type, battery capacity selections, and distributed energy resource sizing. It also contains aggregated financial results, capital expenditures, operating cost summaries, net present cost comparisons across scenarios, and quantified air quality impacts. Results are structured to reflect multiple planning scenarios, including heuristic electrification plans, system-optimized configurations, and sensitivity cases with alternative objective weightings. The modeling was developed using publicly available General Transit Feed Specification data from Omnitrans and standardized modeling assumptions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dataset for Blueprinting Electrified Transit System Implementation

This dataset contains the figures and tabulated results generated from a system-level optimization study of transit fleet electrification planning. The dataset does not include executable modeling code required to reproduce the optimization. The dataset includes results for optimized charging infrastructure deployment by location and power level and service block assignments by fuel type, battery capacity selections, and distributed energy resource sizing. It also contains aggregated financial results, capital expenditures, operating cost summaries, net present cost comparisons across scenarios, and quantified air quality impacts. Results are structured to reflect multiple planning scenarios, including heuristic electrification plans, system-optimized configurations, and sensitivity cases with alternative objective weightings. The modeling was developed using publicly available General Transit Feed Specification data from Omnitrans and standardized modeling assumptions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Different Economic Performance Metrics on the Perceived Value of Solar Photovoltaics

Photovoltaic (PV) systems are installed by several types of market participants, ranging from residential customers to large-scale project developers and utilities. Each type of market participant frequently uses a different economic performance metric to characterize PV value because they are looking for different types of returns from a PV investment. This report finds that different economicperformance metrics frequently show different price thresholds for when a PV investment becomes profitable or attractive. Several project parameters, such as financing terms, can have a significant impact on some metrics [e.g., internal rate of return (IRR), net present value (NPV), and benefit-to-cost (B/C) ratio] while having a minimal impact on other metrics (e.g., simple payback time). Assuch, the choice of economic performance metric by different customer types can significantly shape each customer's perception of PV investment value and ultimately their adoption decision.

14 SOLAR ENERGY↗

Life cycle assessment of co-firing biomass at coal-fired power plants with carbon capture and storage toward net-zero emissions

Co-firing biomass with carbon capture and storage (BECCS) offers a technological option to decarbonize coal-fired power plants toward net-zero emissions. This study estimates the life cycle emissions of co-firing biomass at coal-fired power plants with CCS and quantifies its variability and uncertainty. Deployment of co-firing BECCS at coal-fired power plants can significantly reduce the life cycle emissions toward the net-zero target but lower the power plant performance, which vary with numerous factors, including coal type, biomass type, co-firing level, and CO 2 capture rate. The breakeven co-firing levels required for biomass at coal-fired power plants with 90 % CO 2 capture to reach net-zero emissions fall with a range roughly from 15 % to 25 % on an energy basis, depending on coal and biomass types. Increasing the CO 2 capture rate from 90 % to 95 % can lower the breakeven co-firing levels by about 5 to 8 percentage points for the biomass resources of interest, which can lower reliance on biomass resources and facilitate large-scale deployment of co-firing BECCS in fossil-rich regions but with limited biomass resources. Furthermore, findings improve the understanding of the techno-environmental performance of co-firing BECCS and inform strategic planning decisions on net-zero emissions in the coal-fired power sector.

Breakeven co-firing level↗