Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Predicted vibration responses of Apollo structure and effects of pressure correlation lengths on response

Progressive wove and reverberant acoustic fields ore often used in the laboratory for qualification testing of aerospace structures that are subjected to unsteady aerodynamic environments which occur during flight through the atmosphere. Acoustic simulation of these in-flight environments i s achieved i f the structural vibration response to acoustic excitation is equivalent, over the frequency range of interest, to the response caused by aerodynamic turbulence. To determine the degree of response simulation that could be expected for such qualification testing of the Apollo Spacecraft, responses of a segment of the Apollo structure were estimated theoretically for both acoustic and flight environments. The vibration analysis presented in this report was performed for the Spacecraft Lunar Module Adaptor; and the three environments treated are turbulence at Mach 1 and Mach 2, a reverberant acoustic field, and a modified acoustic progressive wave field. The progressive wave field is assumed to be generated within a specially designed shroud of sixteen axially oriented ducts which is constructed around and contoured to the external skin of the vehicle. Each duct is open on the side adjacent to the skin and is driven acoustically at one end by an independent noise source, thus allowing for different pressure correlation patterns around the circumference of the vehicle. The purpose of the analysis was to determine the effects of surface pressure correlation lengths on the response characteristics of representative Apollo structure, and to select on this basis, the optimum acoustic environment for structural vibration qualification tests of the Apollo in the Spacecraft Acoustic Laboratory at MSC. The method of analysis employed consists of determining, independently, the space average, mean-square acceleration spectral density for each of the significant modes of vibration of an equivalent cylindrical shell, and then expressing the total structural response as a linear summation of these modal responses. Approximately 570 classical modes of a pinned-end cylinder were used in order to find the spectral response characteristics of the structure throughout the frequency range of 10 - 1,000 Hz. The effective forcing functions or joint acceptances of the various modes of vibration were computed and are presented graphically for each of the pressure excitation environments. A brief development of the response equations used is presented in the report. Space average acceleration response spectra were computed for twelve different cases including aerodynamic turbulence at Mach 1 and Mach 2, reverberant acoustic field, five duct correlation patterns, two cases of an axially damped progressive wave field, and two cases in which the structural damping constant was varied from the expected value. The response spectra were computed and plotted by a high speed digital computer far a flat excitation pressure spectrum; and the response spectra were numerically integrated to give one-third octave bond average responses. A complete set of digital computer programs has been developed for both flat plate and cylindrical shell structures for the above environments, and each requires run times of three minutes or less. Thus, the work presented herein, along with the results, constitutes a practical advancement to the existing state-of-the-art of vibration prediction.

R W White↗

Aerodynamic and Aeroelastic Insights using Eigenanalysis

This paper presents novel analytical results for eigenvalues and eigenvectors produced using discrete time aerodynamic and aeroelastic models. An unsteady, incompressible vortex lattice aerodynamic model is formulated in discrete time; the importance of several modeling parameters is examined. A detailed study is made of the behavior of the aerodynamic eigenvalues both in discrete and continuous time. The aerodynamic model is then incorporated into aeroelastic equations of motion. Eigenanalyses of the coupled equations produce stability results and modal characteristics which are valid for critical and non-critical velocities. Insight into the modeling and physics associated with aeroelastic system behavior is gained by examining both the eigenvalues and the eigenvectors. Potential pitfalls in discrete time model construction and analysis are examined.

Heeg, Jennifer↗

Unambiguous Spectral Evidence for High- (and Low-) Calcium Pyroxene In Asteroids and Meteorites

Spectroscopy remains a powerful tool for inferring the modal mineralogy and mafic mineral composition of asteroid surfaces. Since similar measurements can be made on meteorite samples, spectroscopy can help link the two populations and add spatial and geologic context to detailed geo knowledge derived from meteorite samples. For example, analysis of the recent NEAR-Shoemaker mission to Eros include detailed study of NIS spectra to assess the affinity of Eros to ordinary chondrites. As discussed in these studies, pyrox (PYX) and olivine (OLV) absorption are readily detectable in the spectra. Furthermore, subtleties in band parameters (position vs. area) suggest the presence of both low- and high-calcium pyroxene (LCP and HCP), as expected from the petrology of ordinary chondrites. However unambiguous identification and detailed compositional inferences for both LCP and HCP (and OLV) are difficult from band parameters analysis. In this study, we examine spectra of S-asteroids and meteorites with the Modified Gaussian Model (MGM), an absorption band model, to explore the role of HCP in these silicate-rich spectra.

Sunshine, J. M.↗

Unambiguous Spectral Evidence for High- (and Low-) Calcium Pyroxene in Asteroids and Meteorites

Spectroscopy remains a powerful tool for inferring the modal mineralogy and mafic mineral composition of asteroid surfaces. Since similar measurements can be made on meteorite samples, spectroscopy can help link the two populations and add spatial and geologic context to detailed geochemical knowledge derived from meteorite samples. For example, analysis of the recent NEAR-Shoemaker mission to Eros include detailed study of NIS spectra to assess the affinity of Eros to ordinary chondrites. As discussed in these studies, pyroxene (PYX) and olivine (OLV) absorption are readily detectable in the spectra. Furthermore, subtleties in band parameters (position vs. area) suggest the presence of both low- and high-calcium pyroxene (LCP and HCP), as expected from the petrology of ordinary chondrites. However unambiguous identification and detailed compositional inferences for both LCP and HCP (and OLV) are difficult from band parameters analysis. In this study, we examine spectra of S-asteroids and meteorites with the Modified Gaussian Model (MGM), an absorption band model, to explore the role of HCP in these silicate-rich spectra.

Sunshine, J. M.↗

Aerodynamic and Aeroelastic Insights using Eigenanalysis

This paper presents novel analytical results for eigenvalues and eigenvectors produced using discrete time aerodynamic and aeroelastic models. An unsteady, incompressible vortex lattice aerodynamic model is formulated in discrete time; the importance of several modeling parameters is examined. A detailed study is made of the behavior of the aerodynamic eigenvalues both in discrete and continuous time. The aerodynamic model is then incorporated into aeroelastic equations of motion. Eigenanalyses of the coupled equations produce stability results and modal characteristics which are valid for critical and non-critical velocities. Insight into the modeling and physics associated with aeroelastic system behavior is gained by examining both the eigenvalues and the eigenvectors. Potential pitfalls in discrete time model construction and analysis are examined.

Heeg, Jennifer↗

NASA Tech Briefs, March 2011

Topics covered include: Optimal Tuner Selection for Kalman-Filter-Based Aircraft Engine Performance Estimation; Airborne Radar Interferometric Repeat-Pass Processing; Plug-and-Play Environmental Monitoring Spacecraft Subsystem; Power-Combined GaN Amplifier with 2.28-W Output Power at 87 GHz; Wallops Ship Surveillance System; Source Lines Counter (SLiC) Version 4.0; Guidance, Navigation, and Control Program; Single-Frame Terrain Mapping Software for Robotic Vehicles; Auto Draw from Excel Input Files; Observation Scheduling System; CFDP for Interplanetary Overlay Network; X-Windows Widget for Image Display; Binary-Signal Recovery; Volumetric 3D Display System with Static Screen; MMIC Replacement for Gunn Diode Oscillators; Feature Acquisition with Imbalanced Training Data; Mount Protects Thin-Walled Glass or Ceramic Tubes from Large Thermal and Vibration Loads; Carbon Nanotube-Based Structural Health Monitoring Sensors; Wireless Inductive Power Device Suppresses Blade Vibrations; Safe, Advanced, Adaptable Isolation System Eliminates the Need for Critical Lifts; Anti-Rotation Device Releasable by Insertion of a Tool; A Magnetically Coupled Cryogenic Pump; Single Piezo-Actuator Rotary-Hammering Drill; Fire-Retardant Polymeric Additives; Catalytic Generation of Lift Gases for Balloons; Ionic Liquids to Replace Hydrazine; Variable Emittance Electrochromics Using Ionic Electrolytes and Low Solar Absorptance Coatings; Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger; Multi-Mission Power Analysis Tool; Correction for Self-Heating When Using Thermometers as Heaters in Precision Control Applications; Gravitational Wave Detection with Single-Laser Atom Interferometers; Titanium Alloy Strong Back for IXO Mirror Segments; Improved Ambient Pressure Pyroelectric Ion Source; Multi-Modal Image Registration and Matching for Localization of a Balloon on Titan; Entanglement in Quantum-Classical Hybrid; Algorithm for Autonomous Landing; Quantum-Classical Hybrid for Information Processing; Small-Scale Dissipation in Binary-Species Transitional Mixing Layers; Superpixel-Augmented Endmember Detection for Hyperspectral Images; Coding for Parallel Links to Maximize the Expected Value of Decodable Messages; and Microwave Tissue Soldering for Immediate Wound Closure.

Source record↗

Imaging dose in breast radiotherapy: does breast size affect the dose to the organs at risk and the risk of secondary cancer to the contralateral breast?

Correct target positioning is crucial for accurate dose delivery in breast radiotherapy resulting in utilisation of daily imaging. However, the radiation dose from daily imaging is associated with increased probability of secondary induced cancer. The aim of this study was to quantify doses associated with three imaging modalities and investigate the correlation of dose and varying breast size in breast radiotherapy. Planning computed tomography (CT) data sets of 30 breast cancer patients were utilised to simulate the dose received by various organs from a megavoltage computed tomography (MV-CT), megavoltage electronic portal image (MV-EPI) and megavoltage cone-beam computed tomography (MV-CBCT). The mean dose to organs adjacent to the target volume (contralateral breast, lungs, spinal cord and heart) were analysed. Pearson correlation analysis was performed to determine the relationship between imaging dose and primary breast volume and the lifetime attributable risk (LAR) of induced secondary cancer was calculated for the contralateral breast. The highest contralateral breast mean dose was from the MV-CBCT (1.79 Gy), followed by MV-EPI (0.22 Gy) and MV-CT (0.11 Gy). A similar trend was found for all organs at risk (OAR) analysed. The primary breast volume inversely correlated with the contralateral breast dose for all three imaging modalities. As the primary breast volume increases, the likelihood of a patient developing a radiation-induced secondary cancer to the contralateral breast decreases. MV-CBCT showed a stronger relationship between breast size and LAR of developing a radiation-induced contralateral breast cancer in comparison with the MV-CT and MV-EPI. For breast patients, imaging dose to OAR depends on imaging modality and treated breast size. When considering the use of imaging during breast radiotherapy, the patient's breast size and contralateral breast dose should be taken into account.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimodality Local Therapy for Retroperitoneal Sarcoma

Purpose: Soft-tissue sarcomas of the retroperitoneum are rare tumors comprising less than 1% of all malignancies. Although surgery continues as the mainstay of treatment, the large size of these tumors coupled with their proximity to critical structures make resection with wide margins difficult to achieve. The role and timing of radiotherapy are controversial. This study updates our institutional experience using multimodality local therapy for resectable retroperitoneal sarcoma and identifies prognostic factors impacting disease control and survival. Methods and Materials: Between 1974 and 2007, 58 patients with nonmetastatic retroperitoneal sarcoma were treated with surgery and radiation at University of Florida. The median age at radiotherapy was 57 years old (range, 18-80 years). Forty-two patients received preoperative radiotherapy and 16 received postoperative radiotherapy. Nineteen patients received 1.8 Gy once daily and 39 patients received 1.2 Gy twice daily. Variables analyzed for prognostic value included age, grade, kidney involvement, histology, de novo versus recurrent presentation, tumor diameter, margin status, radiotherapy sequencing (preoperative vs. postoperative), total radiation dose, fractionation scheme, and treatment era. Results: The 5-year overall survival, cause-specific survival, and local control rates were 49%, 58%, and 62%, respectively. Nearly two-thirds of disease failures involved a component of local progression. On multivariate analysis, only margin status was significantly associated with improved 5-year local control (85%, negative margins; 63%, microscopic positive margins; 0%, gross positive margins; p < 0.0001) and 5-year overall survival (64%, negative margins; 56%, microscopic positive margins; 13%, gross positive margins; p = 0.0012). Thirty-one Grade 3 or greater toxicities were observed in 22 patients, including two treatment-related deaths (3%). Conclusion: For retroperitoneal sarcoma, local control remains a challenge and combined-modality therapy may be associated with significant acute and late morbidity. Our patterns of failure data suggest that improvements in local control may translate into a survival benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cisplatin Pharmacokinetics in Nontumoral Pig Liver Treated With Intravenous or Transarterial Hepatic Chemoembolization

Purpose: To evaluate cisplatin (CDDP) pharmacokinetics after its intravenous (IV) or intrahepatic arterial administration (IHA) in healthy pigs with or without embolization by absorbable gelatine. Material and Methods: We analysed plasmatic and hepatic drug concentration in four groups of six mini-pigs each according to the modality of administration of CDDP (1 mg/kg): IV, IHA, IHA with partial embolization using absorbable gelatine (IHA-Pe), and IHA with complete embolization (IHA-Te). Unbounded plasmatic and hepatic platinum concentrations were measured. Concentration and pharmacokinetics parameters were compared using analysis of variance. Results: For all groups, there was a rapid and biexponential decrease in free platinum concentration. Plasmatic terminal half-life (T{sub 1/2}) was significantly decreased after embolization at 191, 178, 42, and 41 min after IV, IHA, IHA-Pe, and IHA-Te administration, respectively. Maximal plasmatic concentration and systemic exposure to CDDP (AUC{sub 24}) values were significantly decreased after embolization (C{sub max}p = 0.0075; AUC{sub 24}p = 0.0053). Hepatic CDDP concentration rapidly peaked and then decreased progressively. After 24 h, the residual concentration represented 45, 47, 60, and 63 % of C{sub max}, respectively, after IV, IHA, IHA-Pe, and IHA-Te. Hepatic T{sub 1/2} and AUC{sub {infinity}} values were increased after embolization, but the differences were not statistically significant. Conclusion: This preliminary study confirms the feasibility of a pig model to study systemic and hepatic CDDP pharmacokinetics. Systemic exposure is lower after embolization, which could minimize systemic toxicity. Hepatic T{sub 1/2} elimination and hepatic exposition values are increased with IHA compared with IV administration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemistry and petrology of size fractions of Apollo 17 deep drill core 70009-70006

Instrumental neutron activation analysis was used to examine 34 major, minor and trace elements in 48 bulk soils and size fractions (90-1000 microns, 20-90 microns and less than 20 microns) of the Apollo 17 deep drill core sections 70009-70006 (upper 130 cm). Modal data were also obtained for the less than 20 micron size fraction. Preliminary results indicate that (1) the chemistry of the greater than 90 micron and 20-90 micron coarse fractions is identical but quite different from the less than 20 micron fine fraction; (2) the upper 50 cm of the drill core is highly enriched in mare material; (3) the dominant source of highland material is KREEPy instead of anorthositic; and (4) indigenous volatiles such as Zn are quite high in all size fractions.

Laul, J. C.↗

Dynamic stability of a rotor blade using finite element analysis

The aeroelastic stability of flap bending, lead-lag bending, and torsion of a helicopter rotor blade in hover is examined using a finite element formulation based on the principle of virtual work. Quasi-steady two-dimensional airfoil theory is used to obtain the aerodynamic loads. The rotor blade is discretized into beam elements, each with ten modal degrees of freedom. The resulting nonlinear equations of motion are solved for steady-state blade deflections through an iterative procedure. The flutter solution is calculated assuming blade motion to be a small perturbation about the steady solution. The normal mode method based on the coupled rotating natural modes about the steady deflections is used to reduce the number of equations in the flutter eigenanalysis. Results are presented for hingeless and articulated rotor blade configurations.

Sivaneri, N. T.↗

Medical ultrasound - From inner space to outer space

During the last decade, medical ultrasound has rapidly become a widely accepted imaging modality used in many medical specialties. It has the advantages that it is noninvasive, does not use ionizing radiation, is relatively inexpensive and is easy to use. Future trends in ultrasound include expanded areas of use, advanced signal processing and digital image analysis including tissue characterization and three-dimensional reconstructions.

Rooney, J. A.↗

Dynamic test/analysis correlation using reduced analytical models

Test/analysis correlation is an important aspect of the verification of analysis models which are used to predict on-orbit response characteristics of large space structures. This paper presents results of a study using reduced analysis models for performing dynamic test/analysis correlation. The reduced test-analysis model (TAM) has the same number and orientation of DOF as the test measurements. Two reduction methods, static (Guyan) reduction and the Improved Reduced System reduction, are applied to the test/analysis correlation of a laboratory truss structure. Simulated test results and modal test data are used to examine the performance of each method. It is shown that selection of DOF to be retained in the TAM is critical when large structural masses are involved. In addition, the use of modal test results may provide difficulties in TAM accuracy even if a large number of DOF are retained in the TAM.

Mcgowan, Paul E.↗

SU-F-T-458: Tracking Trends of TG-142 Parameters Via Analysis of Data Recorded by 2D Chamber Array

Purpose: With increasing QA demands of medical physicists in clinical radiation oncology, the need for an effective method of tracking clinical data has become paramount. A tool was produced which scans through data automatically recorded by a 2D chamber array and extracts relevant information recommended by TG-142. Using this extracted information a timely and comprehensive analysis of QA parameters can be easily performed enabling efficient monthly checks on multiple linear accelerators simultaneously. Methods: A PTW STARCHECK chamber array was used to record several months of beam outputs from two Varian 2100 series linear accelerators and a Varian NovalisTx−. In conjunction with the chamber array, a beam quality phantom was used to simultaneously to determine beam quality. A minimalist GUI was created in MatLab that allows a user to set the file path of the data for each modality to be analyzed. These file paths are recorded to a MatLab structure and then subsequently accessed by a script written in Python (version 3.5.1) which then extracts values required to perform monthly checks as outlined by recommendations from TG-142. The script incorporates calculations to determine if the values recorded by the chamber array fall within an acceptable threshold. Results: Values obtained by the script are written to a spreadsheet where results can be easily viewed and annotated with a “pass” or “fail” and saved for further analysis. In addition to creating a new scheme for reviewing monthly checks, this application allows for able to succinctly store data for follow up analysis. Conclusion: By utilizing this tool, parameters recommended by TG-142 for multiple linear accelerators can be rapidly obtained and analyzed which can be used for evaluation of monthly checks.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multimodal framework for the joint analysis of single-cell RNA and T cell receptor sequencing data predicts T cell response to cancer immunotherapy

T cell states are prognostic in different cancer types. Recent technologies enable joint profiling of T cell RNA and T cell receptor (TCR) sequences at single-cell resolution. Here we present the TCR-RNA Integrating Model (TRIM), a multi-modal variational autoencoder framework that integrates RNA-TCR data and predicts T cell clonality and transcriptional states. TRIM learns a shared representation of the data conditioned on patient, tissue source, and treatment timepoint. We applied TRIM to three independent datasets that included T cells collected before and after checkpoint inhibitor treatment, sourced either from blood and tumor biopsies in patients with head and neck squamous cell carcinoma and colorectal cancer, or from tumor and adjacent tissue in a pan-cancer dataset. In all settings, TRIM accurately predicted intra-tumor T cell clonal expansion and transcriptional status based on T cells from blood or normal tissue before treatment, demonstrating its utility in modeling multimodal T cell data and predicting T cell response to treatment and disease progression.

60 APPLIED LIFE SCIENCES↗

Automated Scoring of Morphological Changes in Images of Pentaerythritol Tetranitrate

Recent advances in characterization techniques that generate large datasets of material microstructure images require robust, automated image-processing. We applied an unsupervised anomaly detection method called feature anomaly detection system (FADS) to automatically detect and quantify microstructure changes in images of the explosive pentaerythritol tetranitrate (PETN) aged at various temperatures. We demonstrated the FADS approach on two-dimensional images extracted from computed tomography scans, but the same technique can be readily applied to other imaging modalities. FADS calculates anomaly scores on the basis of differences in filter activations of nominal and test data in pretrained convolutional neural networks. The FADS scores successfully differentiated between pristine PETN and PETN aged at a temperature where material coarsening occurred. Morphological metric analysis of segmented images verified observed trends in FADS scores as a function of aging temperature and aging time, specifically by calculating volume fractions, specific boundary lengths, two-point correlation functions, and local thicknesses. Here, the FADS technique has two important advantages compared to traditional morphological analysis: First, it uses grayscale images as input, rather than images that are segmented to separate the appropriate phases; and second, FADS scores capture any type of changes among image sets, rather than requiring prior knowledge or selection of a relevant set of metrics.

Accelerated aging↗

Cone-Beam CT-Based Delineation of Stereotactic Lung Targets: The Influence of Image Modality and Target Size on Interobserver Variability

Purpose: It is generally agreed that the safe implementation of stereotactic body radiotherapy requires image guidance. The aim of this work was to assess interobserver variability in the delineation of lung lesions on cone-beam CT (CBCT) images compared with CT-based contouring for adaptive stereotactic body radiotherapy. The influence of target size was also evaluated. Methods and Materials: Eight radiation oncologists delineated gross tumor volumes in 12 patient cases (non-small cell lung cancer I-II or solitary metastasis) on planning CTs and on CBCTs. Cases were divided into two groups with tumor diameters of less than (Group A) or more than 2 cm (Group B). Comparison of mean volumes delineated by all observers and range and coefficient of variation were reported for each case and image modality. Interobserver variability was assessed by means of standard error of measurement, conformity index (CI), and its generalized observer-independent approach. The variance between single observers on CT and CBCT images was measured via interobserver reliability coefficient. Results: Interobserver variability on CT images was 17% with 0.79 reliability, compared with 21% variability on CBCT and 0.76 reliability. On both image modalities, values of the intraobserver reliability coefficient (0.99 for CT and 0.97 for CBCT) indicated high reproducibility of results. In general, lower interobserver agreement was observed for small lesions (CI{sub genA} = 0.62 {+-} 0.06 vs. CI{sub genB} = 0.70 {+-} 0.03, p < 0.05). The analysis of single patient cases revealed that presence of spicules, diffuse infiltrations, proximity of the tumors to the vessels and thoracic wall, and respiration motion artifacts presented the main sources of the variability. Conclusion: Interobserver variability for Stage I-II non-small cell lung cancer and lung metastasis was slightly higher on CBCT compared with CT. Absence of significant differences in interobserver variability suggests that CBCT imaging provides an effective tool for tumor localization, and image data could be also used for target volume delineation purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗