Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Vertebral Compression Fractures in Elderly: How to Recognize and Report

Purpose of Review: In elderly patients, when there is no obvious evidence of malignancy on plain radiography, it can be difficult to evaluate benign and malignant vertebral fractures, because these patients are predisposed to senile osteoporosis and malignant disease. The only complaint could be back pain, as both types of fractures have the same symptoms and signs. Recent Findings: A reliable imaging modality is always required, as appropriate management and early diagnosis of malignant vertebral fractures are important. Summary: The aim of this study was to highlight the importance of recognizing, through diagnostic techniques, the presence of vertebral fractures, since the majority of vertebral fractures do not come to clinical attention and to determine the parameters that are useful for the early differentiation between benign versus malignant vertebral fractures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing Cardiac CTA Acquisition in Congenital Heart Disease

Purpose of Review: The purpose of this review of performance of cardiac computed tomographic angiography (CCTA) in patients with congenital heart disease (CHD) is to describe a strategy for optimizing CCTA protocols for various forms of CHD at diagnosis and throughout the lifetime of a patient. Recent Findings: Recent expert consensus statements provide key recommendations for patient selection and technical performance of CCTA with tips to optimize contrast injection, scan acquisition, and understanding anatomy and postoperative changes in patients with CHD. Spectral CT will become invaluable in acquiring image data which has potential for enabling improved image quality and perhaps physiologic information. Summary: CCTA is an important non-invasive imaging modality for making initial diagnosis and providing follow-up imaging in patients of all ages with CHD. Optimization of imaging protocols requires combined expertise in all forms of CHD, surgical palliation procedures, and knowledge of surgical options for CHD surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Static and Dynamic Ultrasound Imaging of the Iliotibial Band/Fascia Lata: Brief Review of Current Literature and Gaps in Knowledge

Purpose of the Review: The physiopathology of iliotibial band syndrome (ITBS) remains obscure and ultrasound (US) imaging could be a low-cost modality improving our understanding of this condition as well as its diagnosis and management. This brief review synthesizes the up-to-date knowledge on static and dynamic US imaging measurements of the fascia lata and iliotibial band (ITB) in both asymptomatic individuals and patients with ITBS. Recent Findings: Mean ITB thickness values for asymptomatic individuals ranged from 1.10 to 1.95 mm. Only three studies with very small sample size focused on ITBS patients and no quantitative data were reported. All dynamic US imaging studies involved asymptomatic participants. One study demonstrated a lateral movement of the ITB relative to the femoral condyle and a group of investigators showed 3D displacement of the fascia lata. No study could be found on ITB loose connective tissue measurements. Summary: This review clearly indicates a paucity of research in the field of static and dynamic US measures. Measuring the loose connective tissue that lies between the deep fascia layers could be an interesting target to help our understanding of ITBS and improve care for the patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual-Energy CT Pulmonary Angiography: Quantification of Disease Burden and Impact on Management

Purpose of Review: Computed tomography pulmonary angiography (CTPA) has become the imaging modality of choice for patients with suspected pulmonary embolism (PE). Post-processing techniques currently available for dual-energy CT pulmonary angiography (DE-CTPA) enhance image quality and provide additional value in the diagnosis of PE. The objective of this article is to summarize these recent developments and discuss the appropriate use of DE-CTPA post-processing applications. Recent Findings: DE-CTPA post-processing applications enable reconstruction of virtual monoenergetic images (VMI) and color-coded iodine-perfusion maps to increase contrast conditions and visualize lung perfusion defects in case of embolic occlusion of pulmonary arteries. Both techniques revealed a superior diagnostic performance for the detection of pulmonary emboli and assessment of the pulmonary perfusion compared to the standard image reconstructions. Summary: DE-CTPA is a well-established method for excluding or diagnosing PE. Continued developments in DE-CTPA post-processing techniques improve patient management and allow for a quantification of disease burden.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sputter-Deposited Mo Thin Films: Multimodal Characterization of Structure, Surface Morphology, Density, Residual Stress, Electrical Resistivity, and Mechanical Response

Multimodal datasets of materials are rich sources of information which can be leveraged for expedited discovery of process–structure–property relationships and for designing materials with targeted structures and/or properties. For this data descriptor article, we provide a multimodal dataset of magnetron sputter-deposited molybdenum (Mo) thin films, which are used in a variety of industries including high temperature coatings, photovoltaics, and microelectronics. In this dataset we explored a process space consisting of 27 unique combinations of sputter power and Ar deposition pressure. Here, the phase, structure, surface morphology, and composition of the Mo thin films were characterized by x-ray diffraction, scanning electron microscopy, atomic force microscopy, and Rutherford backscattering spectrometry. Physical properties—namely, thickness, film stress and sheet resistance—were also measured to provide additional film characteristics and behaviors. Additionally, nanoindentation was utilized to obtain mechanical load-displacement data. The entire dataset consists of 2072 measurements including scalar values (e.g., film stress values), 2D linescans (e.g., x-ray diffractograms), and 3D imagery (e.g., atomic force microscopy images). An additional 1889 quantities, including film hardness, modulus, electrical resistivity, density, and surface roughness, were derived from the experimental datasets using traditional methods. Minimal analysis and discussion of the results are provided in this data descriptor article to limit the authors’ preconceived interpretations of the data. Overall, the data modalities are consistent with previous reports of refractory metal thin films, ensuring that a high-quality dataset was generated. The entirety of this data is committed to a public repository in the Materials Data Facility.

36 MATERIALS SCIENCE↗

A Workflow for Accelerating Multimodal Data Collection for Electrodeposited Films

Abstract Future machine learning strategies for materials process optimization will likely replace human capital-intensive artisan research with autonomous and/or accelerated approaches. Such automation enables accelerated multimodal characterization that simultaneously minimizes human errors, lowers costs, enhances statistical sampling, and allows scientists to allocate their time to critical thinking instead of repetitive manual tasks. Previous acceleration efforts to synthesize and evaluate materials have often employed elaborate robotic self-driving laboratories or used specialized strategies that are difficult to generalize. Herein we describe an implemented workflow for accelerating the multimodal characterization of a combinatorial set of 915 electroplated Ni and Ni–Fe thin films resulting in a data cube with over 160,000 individual data files. Our acceleration strategies do not require manufacturing-scale resources and are thus amenable to typical materials research facilities in academic, government, or commercial laboratories. The workflow demonstrated the acceleration of six characterization modalities: optical microscopy, laser profilometry, X-ray diffraction, X-ray fluorescence, nanoindentation, and tribological (friction and wear) testing, each with speedup factors ranging from 13–46x. In addition, automated data upload to a repository using FAIR data principles was accelerated by 64x.

36 MATERIALS SCIENCE↗

Experimental and Numerical Investigation on Vibration of Sandwich Plates with Honeycomb Cores Based on Radial Basis Function

The vibration characteristic of the sandwich plate with a honeycomb core was investigated by experimental measurements and numerical calculation based on radial basis function (RBF). RBF method was used not only in the meshless approach but also in the post-processing of the experimental data. During the experiment, amplitude-fluctuation electronic speckle pattern interferometry was applied to access the resonant frequencies and the corresponding vibration mode shapes simultaneously. Then RBF method was used to improve the quality of patterns and reconstruct the out-of-plane vibration amplitude after fringe analysis. As for numerical calculation, the modal parameters were numerically predicted using the first-order shear deformation theory. The computation approach was based on collocation with multi-quadric radial basis function. To understand the influence of the thickness of face sheet on dynamic behaviors, three types of specimens with different thickness were tested and analyzed. Of particular interest was that the vibration modes show veering due to the thickness increment. Furthermore, the numerical predicted results were compared with the experimental measurements for the first five modes. They are in good agreement with each other for resonant frequencies, mode shapes and relative out-of-plane amplitudes.

36 MATERIALS SCIENCE↗

Shape-constrained Input Estimation for Efficient Multi-shaker Vibration Testing

Multi-shaker vibration testing is gaining interest from structural dynamics test engineers as it can provide a much more accurate match to complicated field vibration responses than traditional single-axis shaker tests. However, the force capabilities of the small modal shakers typically used in multi-shaker vibration tests has limited the achievable response levels. To date, most multi-shaker vibration tests have been performed using a variety of standard, commercially-available control systems. While these control systems are adequate for a wide range of multiple-input/multiple-output tests, their control algorithms have not been tailored for the specific problem of multi-shaker vibration tests: efficiently coordinating the various shakers to work together to achieve a desired response. Here, a new input estimation algorithm is developed and demonstrated using simulations and actual test data. This algorithm, dubbed shape-constrained input estimation, is shown to effectively coordinate multiple shakers using a set of constraint vectors based on the deflection shapes of the test structure. This is accomplished by using the singular vector shapes of the system frequency response matrix, which allows the constraint vectors to automatically change as a function of frequency. Simulation and test results indicate a significant reduction in the input forces required to achieve a desired response. Finally, the results indicate that shape-constrained input estimation is an effective method to achieve higher response levels from limited shaker forces which will enable higher level multi-shaker vibration tests to be performed.

42 ENGINEERING↗

Predicting System Response at Unmeasured Locations

Traditional techniques to derive dynamic specification for components have a great deal of uncertainty. One of the major sources of uncertainty is that the number of response measurements in the operational system environment is insufficient to determine the component motion. This inadequacy is due to logistical limitations for data recording in field testing and space limitations for accelerometers, strain gages and associated wiring. Available measurements are often some distance from the component and therefore do not represent component motion. Typical straight-line envelopes of these unrepresentative measurements guarantee an increase in the uncertainty. In this paper multiple methods are attempted to expand a sparse set of field test measurements on a system to responses of interest that cannot be measured in the field due to the limitations. Proof of concept is demonstrated on the Modal Analysis Test Vehicle (MATV). The responses of interest, known as “truth responses”, are measured in a system vibration environment along with an optimized sparse set of 30 field responses. Methods to expand the field responses to the truth responses are demonstrated by comparing the acceleration spectral density of the expanded response to the measured response. Two methods utilize a validated finite element model of the MATV. One is developed from purely experiment based frequency response functions of a laboratory pre-test. Finally, these approaches are designed to drastically reduce the uncertainty of the component in-service motion as a basis for developing specifications that are guaranteed to be conservative with a known (instead of unknown) conservatism.

42 ENGINEERING↗

Advances in in situ/operando techniques for catalysis research: enhancing insights and discoveries

Abstract Catalysis research has witnessed remarkable progress with the advent of in situ and operando techniques. These methods enable the study of catalysts under actual operating conditions, providing unprecedented insights into catalytic mechanisms and dynamic catalyst behavior. This review discusses key in situ techniques and their applications in catalysis research. Advances in in situ electron microscopy allow direct visualization of catalysts at the atomic scale under reaction conditions. In situ spectroscopy techniques like X-ray absorption spectroscopy and nuclear magnetic resonance spectroscopy can track chemical states and reveal transient intermediates. Synchrotron-based techniques offer enhanced capabilities for in situ studies. The integration of in situ methods with machine learning and computational modeling provides a powerful approach to accelerate catalyst optimization. However, challenges remain regarding radiation damage, instrumentation limitations, and data interpretation. Overall, continued development of multi-modal in situ techniques is pivotal for addressing emerging challenges and opportunities in catalysis research and technology.

Chen, Linfeng↗

Design and Implementation of a Compact Low-Dose Diffraction Enhanced Medical Imaging System

This paper describes the design, construction, and performance of a new DEI system using a commercially available tungsten anode x-ray tube and includes the first high-quality low-dose diffraction-enhanced images of full-thickness human tissue specimens. Diffraction-enhanced imaging (DEI) is a new x-ray imaging modality that differs from conventional radiography in its use of three physical mechanisms to generate contrast. DEI is able to generate contrast from x-ray absorption, refraction, and ultra-small-angle scatter rejection (extinction) to produce high-contrast images with a much lower radiation dose compared to conventional radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiologist Evaluation of an X-ray Tube Based Diffraction Enhanced Imaging Prototype Using Full Thickness Breast Specimens.

Conventional mammographic image contrast is derived from x-ray absorption, resulting in breast structure visualization due to density gradients that attenuate radiation without distinction between transmitted, scattered, or refracted x-rays. Diffraction-enhanced imaging (DEI) allows for increased contrast with decreased radiation dose compared to conventional mammographic imaging because of monochromatic x-rays, its unique refraction-based contrast mechanism, and excellent scatter rejection. However, a lingering drawback to the clinical translation of DEI has been the requirement for synchrotron radiation. The authors laboratory developed a DEI prototype (DEI-PR) using a readily available tungsten x-ray tube source and traditional DEI crystal optics, providing soft tissue images at 60 keV. Images of full-thickness human breast tissue specimens were acquired on synchrotron-based DEI (DEI-SR), DEI-PR, and digital mammographic systems. A panel of expert radiologists evaluated lesion feature visibility and correlation with pathology after receiving training on the interpretation of refraction contrast mammographic images. For mammographic features (mass, calcification), no significant differences were detected between the DEI-SR and DEI-PR systems. Benign lesions were perceived as better seen by radiologists using the DEI-SR system than the DEI-PR system at the [111] reflectivity, with generalizations limited by small sample size. No significant differences between DEI-SR and DEI-PR were detected for any other lesion type (atypical, cancer) at either crystal reflectivity. Thus, except for benign lesion characterizations, the DEI-PR system's performance was roughly equivalent to that of the traditional DEI system, demonstrating a significant step toward clinical translation of this modality for breast cancer applications.

59 BASIC BIOLOGICAL SCIENCES↗

A study of the interactive effects of strain, strain rate and temperature in severe plastic deformation of copper

The deformation field in machining was controlled to access a range of deformation parameters—strains of 1–15, strain rates of 10–100,000 s –1 and temperatures of up to 0.4 T m —in the severe plastic deformation (SPD) of copper. This range is far wider than has beenaccessed to date in conventional SPD methods, enabling a study of the interactive effects of the parameters on microstructure andstrength properties. Nano-twinning was demonstrated at strain rates as small as 1000 s –1 at 196 °C and at strain rates of ≥10,000 s –1 even when the deformation temperature was well above room temperature. Bi-modal grain structures were produced ina single stage of deformation through in situ partial dynamic recrystallization. Furthermore, the SPD conditions for engineering specific microstructuresby deformation rate control are presented in the form of maps, both in deformation parameter space and in terms of the Zener–Hollomon parameter. 20

36 MATERIALS SCIENCE↗

Overcoming mechanical fragility in Sm-Co permanent magnet materials

Samarium-cobalt alloys are used in some of the strongest permanent magnets, particularly for applications between about 200 and 550°C, but the utilization of these materials is restricted by their brittleness. Improving their mechanical resilience would allow them to be used more widely and, in some cases, substitute for neodymium-based magnet alloys which are subject to supply-chain risks. In this work, we have engineered a series of novel microstructures with bi-modal grain size distributions to achieve unprecedented combinations of mechanical and magnetic properties. Improvements up to 73% are obtained in the flexural strength of Sm 2 (CoFeCuZr) 17 sintered magnets, with negligible impact on the magnetic properties. Our mechanically-robust, high-performance Sm-Co magnets are made without changing the chemical compositions of the materials or their heat treatment procedures, making them highly compatible with existing manufacturing processes.

36 MATERIALS SCIENCE↗

Direct observations and characterization of crack closure during microstructurally small fatigue crack growth via in-situ high-energy X-ray characterization

This study provides direct observation of the crack closure mechanism of a naturally occurring, tortuous, 3D microstructurally small fatigue crack (SFC) in additively manufactured Inconel 718. In-situ non-destructive characterization is performed using high-energy X-ray diffraction techniques to capture the evolution of the 3D microstructure and micromechanical response in the vicinity of the crack front. Based on the stress state of twelve grains analyzed at the crack tip, the crack closure events of the SFC front was found to be spatially heterogeneous with respect to loading progression governed by the local stress state of the grains (specifically the stress reversal from compression to tension). From this analysis, three grains that displayed different degrees of crack closure were further investigated, based on the orientation of the crack relative to the grains and the associated modality of crack growth. The stress normal to the crack plane and the associated degree of Mode I crack behavior were correlated with events of the crack opening earlier during the loading cycle. This was further corroborated by diffraction spot spreading analysis that quantified the crystallographic lattice distortion caused by the opening crack. Additionally, the detailed characterization of the opening behavior of the grains located at the crack tip and their associated states of stress elucidates the mechanism governing crack closure and will inform future modeling efforts of this phenomenon.

36 MATERIALS SCIENCE↗

Theory-guided design of duplex-phase multi-principal-element alloys

Density-functional theory (DFT) is used to identify phase-equilibria in multi-principal-element and high-entropy alloys (MPEAs/HEAs), including duplex-phase and eutectic microstructures. Here, a combination of composition-dependent formation energy and electronic-structure-based ordering parameters were used to identify a transition from FCC to BCC favoring mixtures, and these predictions experimentally validated in the Al-Co-Cr-Cu-Fe-Ni system. A sharp crossover in lattice structure and dual-phase stability as a function of composition were predicted via DFT and validated experimentally. The impact of solidification kinetics and thermodynamic stability was explored experimentally using a range of techniques, from slow (castings) to rapid (laser remelting), which showed a decoupling of phase fraction from thermal history, i.e., phase fraction was found to be solidification rate-independent, enabling tuning of a multi-modal cell and grain size ranging from nanoscale through macroscale. Strength and ductility tradeoffs for select processing parameters were investigated via uniaxial tension and small-punch testing on specimens manufactured via powder-based additive manufacturing (directed-energy deposition). This work establishes a pathway for design and optimization of next-generation multiphase superalloys via tailoring of structural and chemical ordering in concentrated solid solutions.

36 MATERIALS SCIENCE↗

Switching kinetics in ferroelectric zinc magnesium oxide thin films

The switching kinetics of RF-magnetron reactively sputtered ~200 nm thick Zn 1-x Mg x O (ZMO) ferroelectric thin films with x = 0.41 and x = 0.27 prepared on Pt/Ti/SiO 2 /Si substrates were studied at applied fields near the coercive fields, ranging from 3.4 to 5.1 MV cm -1 , and at temperatures ranging from room temperature to 100 °C. Polarization reversal in ZMO followss the Kolmogorov-Avrami-Ishibashi kinetics model for nucleation and growth at applied fields near the coercive field, and obeys an individual column switching (ICS) model at higher applied fields required to switch most of the spontaneous polarization. Switching in the high-applied field regime can be described using either the Gaussian or inverse gamma distribution functions depending on the mole fraction of magnesium in the film. The switching current transients of the high-Mg content ZMO film (x = 0.41) are always bi-modal, whereas the low Mg composition film (x = 0.27) is described by the Gaussian distribution initially following wake-up, and becomes bimodal with continued cycling. Rayleigh-like behavior of the dielectric constant revealed a simultaneous increase of the irreversible and decrease of the reversible contributions to the dielectric constant, which was ascribed to an increase in the density of mobile domain walls with cycling and resulted in faster switching.

30 DIRECT ENERGY CONVERSION↗

Revisiting solidification microstructure selection maps in the frame of additive manufacturing

Understanding microstructural development in additive manufacturing under highly non-equilibrium cooling conditions and the consequent effects on mechanical properties of the final component is critical for accelerating industrial adoption of these manufacturing techniques. In this study, simple but effective theoretical solidification models are recalled to evaluate their ability to predict of microstructural features in additive manufacturing applications. As a case study, the resulting solidification microstructure selection maps are created to predict the stable growth modality and the columnar to equiaxed transition (CET) of an Al-10Si-0.5Mg alloy processed via Selective Laser Melting. The potential of this method in microstructural predictions for additively manufactured products, as well as outstanding challenges and limitations, are discussed.

36 MATERIALS SCIENCE↗