Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Matched”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Analytic Solution of the Envelope Equations for an Undepressed Matched Beam in a FODO Quadrupole Channel

In 1958, Courant and Snyder analyzed the problem of alternating-gradient beam transport and treated a model without focusing gaps or space charge. Recently we revisited their work and found the exact solution for matchedbeam envelopes in a linear quadrupole lattice [O.A. Anderson and L.L. LoDestro, Phys. Rev. ST Accel. Beams, 2009]. We extend that work here to include the effect of asymmetric drift spaces. We derive the solution and show exact envelopes for the first two solution bands and the peak envelope excursions as a function of the phase advancesigma up to 360o. In the second stable band, decreased occupancy requires higher focus field-strength and accentuates the remarkable compression effect predicted for the FD (gapless) model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Molecular dynamics simulations of water confined between matched pairs of hydrophobic and hydrophilic self-assembled monolayers.

We have conducted a molecular dynamics (MD) simulation study of water confined between methyl-terminated and carboxyl-terminated alkylsilane self-assembled monolayers (SAMs) on amorphous silica substrates. In doing so, we have investigated the dynamic and structural behavior of the water molecules when compressed to loads ranging from 20 to 950 MPa for two different amounts of water (27 and 58 water molecules/nm{sup 2}). Within the studied range of loads, we observe that no water molecules penetrate the hydrophobic region of the carboxyl-terminated SAMs. However, we observe that at loads larger than 150 MPa water molecules penetrate the methyl-terminated SAMs and form hydrogen-bonded chains that connect to the bulk water. The diffusion coefficient of the water molecules decreases as the water film becomes thinner and pressure increases. When compared to bulk diffusion coefficients of water molecules at the various loads, we found that the diffusion coefficients for the systems with 27 water molecules/nm{sup 2} are reduced by a factor of 20 at low loads and by a factor of 40 at high loads, while the diffusion coefficients for the systems with 58 water molecules/nm{sup 2} are reduced by a factor of 25 at all loads.

99 GENERAL AND MISCELLANEOUS↗

Large Matched-Index-of-Refraction (MIR) Flow Systems for International Collaboration In Fluid Mechanics

In recent international collaboration, INL and Uni. Erlangen have developed large MIR flow systems which can be ideal for joint graduate student education and research. The benefit of the MIR technique is that it permits optical measurements to determine flow characteristics in complex passages and around objects to be obtained without locating a disturbing transducer in the flow field and without distortion of the optical paths. The MIR technique is not new itself; others employed it earlier. The innovation of these MIR systems is their large size relative to previous experiments, yielding improved spatial and temporal resolution. This report will discuss the benefits of the technique, characteristics of the systems and some examples of their applications to complex situations. Typically their experiments have provided new fundamental understanding plus benchmark data for assessment and possible validation of computational thermal fluid dynamic codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

International Medical Graduates in Radiation Oncology: Historical Trends and Comparison With Other Medical Specialties

Purpose: This is the first National Resident Matching Program analysis evaluating historical patterns of international medical graduates (IMGs) in radiation oncology (RO) and providing comparison with American (MD) medical graduates (AMGs), osteopathic students (DOs), unfilled positions, and other specialties. Methods and Materials: National Resident Matching Program data for IMGs were available from 2003 to 2015, with limited data for other specialty matches. The following RO-specific figures were obtained per year: total positions available; total matched positions; number of unfilled positions; and number of IMG, AMG, and DO matches. In addition, the number of IMG matches and total matched positions were obtained for 19 other specialties. Fisher exact tests and χ{sup 2} tests were considered significant at α <.05. Results: From 2010 to 2015, 0.8% of RO matches were IMGs, a decline from 2.4% in 2003 to 2009 (P=.006). Proportions of DO matches during these intervals increased by 40% (from 1.0% to 1.4%), significantly lower than IMGs for 2003 to 2009 (P=.03) but not 2010 to 2015 (P=.26). From 2003 to 2015, the percentage of IMG matches, at 1.5%, was significantly lower than the percentage of unfilled seats, at 3.5% (P<.001). In comparison with other specialties (2003-2015), RO had the fewest IMG matches (1.5%), followed by otolaryngology (1.9%) and orthopedics (2.2%); specialties with the highest IMG proportions were internal medicine (37.1%), family medicine (35.7%), and neurology (31.1%). Conclusions: Presently, IMGs represent <1% of RO matches, the lowest among major specialties. There are several speculative factors associated with this low proportion. There are significantly more unfilled positions than those filled by IMGs; programs at risk of not matching could weigh the advantages and disadvantages of interviewing IMGs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HOST GALAXY IDENTIFICATION FOR SUPERNOVA SURVEYS

Host galaxy identification is a crucial step for modern supernova (SN) surveys such as the Dark Energy Survey and the Large Synoptic Survey Telescope, which will discover SNe by the thousands. Spectroscopic resources are limited, and so in the absence of real-time SN spectra these surveys must rely on host galaxy spectra to obtain accurate redshifts for the Hubble diagram and to improve photometric classification of SNe. In addition, SN luminosities are known to correlate with host-galaxy properties. Therefore, reliable identification of host galaxies is essential for cosmology and SN science. We simulate SN events and their locations within their host galaxies to develop and test methods for matching SNe to their hosts. We use both real and simulated galaxy catalog data from the Advanced Camera for Surveys General Catalog and MICECATv2.0, respectively. We also incorporate “hostless” SNe residing in undetected faint hosts into our analysis, with an assumed hostless rate of 5%. Our fully automated algorithm is run on catalog data and matches SNe to their hosts with 91% accuracy. We find that including a machine learning component, run after the initial matching algorithm, improves the accuracy (purity) of the matching to 97% with a 2% cost in efficiency (true positive rate). Although the exact results are dependent on the details of the survey and the galaxy catalogs used, the method of identifying host galaxies we outline here can be applied to any transient survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Virtual tool mark generation for efficient striation analysis in forensic science

In 2009, a National Academy of Sciences report called for investigation into the scienti c basis behind tool mark comparisons (National Academy of Sciences, 2009). Answering this call, Chumbley et al. (2010) attempted to prove or disprove the hypothesis that tool marks are unique to a single tool. They developed a statistical algorithm that could, in most cases, discern matching and non-matching tool marks made at di erent angles by sequentially numbered screwdriver tips. Moreover, in the cases where the algorithm misinterpreted a pair of marks, an experienced forensics examiner could discern the correct outcome. While this research served to con rm the basic assumptions behind tool mark analysis, it also suggested that statistical analysis software could help to reduce the examiner&#x27;s workload. This led to a new tool mark analysis approach, introduced in this thesis, that relies on 3D scans of screwdriver tip and marked plate surfaces at the micrometer scale from an optical microscope. These scans are carefully cleaned to remove noise from the data acquisition process and assigned a coordinate system that mathematically de nes angles and twists in a natural way. The marking process is then simulated by using a 3D graphics software package to impart rotations to the tip and take the projection of the tip&#x27;s geometry in the direction of tool travel. The edge of this projection, retrieved from the 3D graphics software, becomes a virtual tool mark. Using this method, virtual marks are made at increments of 5 and compared to a scan of the evidence mark. The previously developed statistical package from Chumbley et al. (2010) performs the comparison, comparing the similarity of the geometry of both marks to the similarity that would occur due to random chance. The resulting statistical measure of the likelihood of the match informs the examiner of the angle of the best matching virtual mark, allowing the examiner to focus his/her mark analysis on a smaller range of angles. Preliminary results are quite promising. In a study with both sides of 6 screwdriver tips and 34 corresponding marks, the method distinguished known matches from known non-matches with zero false positive matches and only two matches mistaken for non-matches. For matches, it could predict the correct marking angle within 5-10 . Moreover, on a standard desktop computer, the virtual marking software is capable of cleaning 3D tip and plate scans in minutes and producing a virtual mark and comparing it to a real mark in seconds. These results support several of the professional conclusions of the tool mark analysis com- munity, including the idea that marks produced by the same tool only match if they are made at similar angles. The method also displays the potential to automate part of the comparison process, freeing the examiner to focus on other tasks, which is important in busy, backlogged crime labs. Finally, the method o ers the unique chance to directly link an evidence mark to the tool that produced it while reducing potential damage to the evidence.

42 ENGINEERING↗

Circuit model of the ITER-like antenna for JET and simulation of its control algorithms

The ITER-like Antenna (ILA) for JET [1] is a 2 toroidal by 2 poloidal array of Resonant Double Loops (RDL) featuring in-vessel matching capacitors feeding RF current straps in conjugate-T manner, a low impedance quarter-wave impedance transformer, a service stub allowing hydraulic actuator and water cooling services to reach the aforementioned capacitors and a 2nd stage phase-shifter-stub matching circuit allowing to correct/choose the conjugate-T working impedance. Toroidally adjacent RDLs are fed from a 3dB hybrid splitter. It has been operated at 33, 42 and 47MHz on plasma (2008-2009) while it presently estimated frequency range is from 29 to 49MHz. At the time of the design (2001-2004) as well as the experiments the circuit models of the ILA were quite basic. The ILA front face and strap array Topica model was relatively crude and failed to correctly represent the poloidal central septum, Faraday Screen attachment as well as the segmented antenna central septum limiter. The ILA matching capacitors, T-junction, Vacuum Transmission Line (VTL) and Service Stubs were represented by lumped circuit elements and simple transmission line models. The assessment of the ILA results carried out to decide on the repair of the ILA identified that achieving routine full array operation requires a better understanding of the RF circuit, a feedback control algorithm for the 2nd stage matching as well as tighter calibrations of RF measurements. The paper presents the progress in modelling of the ILA comprising a more detailed Topica model of the front face for various plasma Scrape Off Layer profiles, a comprehensive HFSS model of the matching capacitors including internal bellows and electrode cylinders, 3D-EM models of the VTL including vacuum ceramic window, Service stub, a transmission line model of the 2nd stage matching circuit and main transmission lines including the 3dB hybrid splitters. A time evolving simulation using the improved circuit model allowed to design and simulate the effectiveness of a feedback control algorithm for the 2nd stage matching and demonstrates the simultaneous matching and control of the 4 RDLs: 11 feedback loops control 21 actuators (8 capacitors, 4 phase shifters and 4 stubs for the 2nd stage matching, 4 main phase shifters controlling of the toroidal phasing and the electronically controlled phase between RF sources feeding top and bottom parts of the array and determines the poloidal phasing of the array which is solved explicitly at each time step) on (simulated) ELMy plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NEAR-INFRARED COUNTERPARTS OF CHANDRA X-RAY SOURCES TOWARD THE GALACTIC CENTER

The Chandra X-ray Observatory has now discovered nearly 10,000 X-ray point sources in the 2{sup 0} x 0.{sup 0}8 region around the Galactic Center. The sources are likely to be a population of accreting binaries in the Galactic Center, but little else is known of their nature. We obtained JHK{sub s} imaging of the 17' x 17' region around Sgr A*, an area containing 4339 of these X-ray sources, with the ISPI camera on the Cerro Tololo Inter-American Observatory (CTIO) 4 m telescope. We cross-correlate the Chandra and ISPI catalogs to find potential IR counterparts to the X-ray sources. The extreme IR source crowding in the field means that it is not possible to establish the authenticity of the matches with astrometry and photometry alone. We find 2137 IR/X-ray astrometrically matched sources: statistically, we estimate that our catalog contains 289 {+-} 13 true matches to soft X-ray sources and 154 {+-} 39 matches to hard X-ray sources. However, the fraction of true counterparts to candidate counterparts for hard sources is just 11%, compared to 60% for soft sources, making hard source NIR matches particularly challenging for spectroscopic follow-up. We calculate a color-magnitude diagram (CMD) for the matches to hard X-ray sources, and find regions where significant numbers of the IR matches are real. We use their CMD positions to place limits on the absolute K{sub s} -band magnitudes of the potential NIR counterparts to hard X-ray sources. We find regions of the counterpart CMD with 9 {+-} 3 likely Wolf-Rayet/supergiant binaries (with four spectroscopically confirmed in the literature) as well as 44 {+-} 13 candidates that could consist of either main-sequence high mass X-ray binaries or red giants with an accreting compact companion. In order to aid spectroscopic follow-up, we sort the candidate counterpart catalog on the basis of IR and X-ray properties to determine which source characteristics increase the probability of a true match. We find a set of 98 IR matches to hard X-ray sources with reddenings consistent with GC distances which have a 45% probability of being true counterparts.

79 ASTRONOMY AND ASTROPHYSICS↗

The Critical Importance of Data Reduction Calibrations in the Interpretability of S-type Asteroid Spectra

There is significant dispute concerning the interpretation and meteoritic affinities of S-type asteroids. Some of this arises from the use of inappropriate analysis methods and the derivation of conclusions which cannot be supported by those interpretive methodologies [1]. The most frequently applied inappropriate technique is curve matching. Whether matching spectra from a spectral library or mixing end-member spectra to match the asteroid spectrum, curve matching for S-type spectra suffers from a suite of weaknesses that are virtually impossible to overcome. Chief among these is the lack of a comprehensive comparison set. Lacking a complete library that includes both the mineralogical variations and the spectrally significant physical variations (e.g., particle size, petrographic relationships, etc.), curve matches are plagued with potential unresolved ambiguities. The other major weakness of virtually all curve matching efforts is that equal weight is given to matching all portions of the spectrum. In actuality, some portions of the spectrum (e.g., centers of absorption features) must be matched very accurately while other portions of the spectrum (e.g., continuum regions and overall slopes) do not require good matches since they are strongly effected by parameters unrelated to the mineralogy of the sample.

Gaffey, Michael J.↗

Identification of Leakage Spectra from Neutron Activation in Glass/Cherenkov Detectors - Paper 96

Oak Ridge National Laboratory has developed a new detector system concept that can be deployed in major US cities to identify the leakage spectrum of a nuclear weapon detonation. The detector is based on a small piece of glass that has been doped with an element that has a high activation cross section and creates a radioactive activation product with a reasonable length half-life. The decay of the activation product(s) after exposure creates Cherenkov light which can propagate to a photomultiplier and can be turned into a count-rate signal. The signal from each glass in each detector in a city can be individually analyzed to determine the amount of activation products produced in the initial exposure. Several activation products can be determined in a single glass if the half-lives are not the same. With a known source location and a detailed 3D model of a city, neutron transport simulations can be made by using a library of known sources to predict the activation amounts each source would have made in the glass detectors. A simple comparison of the measured activation amounts and the predicted activation amounts can identify the source spectrum contained in the library that is the best match. Choosing dopants with a large range in the threshold energy for the activation reactions can help to differentiate the spectra in the library. The method of matching the measured activation amounts to the predicted activation amounts to identify the source spectrum is similar to the analysis used for the passive Activation Foil Integrated Detector System (AFIDS), also developed at Oak Ridge National Laboratory. In AFIDS, wires or foils of known mass and isotopic composition are deployed before and then collected after exposure. Counting gammas in a nearby laboratory determines the activation amounts. The glass/Cherenkov system is active - it uses a battery-powered detector to count flashes of Cherenkov light and to communicate its count rates to a remote location for further analysis. Work has been performed in several areas, including glass making, automated detection and communication systems and software tools for analysis of the signal and source spectrum identification. Bell and Boatner have developed phosphate glasses that incorporate elements with high capture cross sections, and Hayward has simulated the response with Geant4 and measured the response with isotopic gamma sources. This paper will focus on the software tools for determining the activation amounts from the Cherenkov count-rate signal and finding the best matching source spectrum. A test problem in an urban environment is used to demonstrate the potential of a spectrum identification system using neutron activation. The analysis methods developed to identify the neutron leakage spectra from Cherenkov light given off by neutron activation in doped glasses work well. The calculation used to unfold the count-rate information into the number of actual activation products uses robust algorithms that can also compute associated uncertainties. These uncertainties and the known uncertainties of the glass tube material compositions are incorporated into the matching analysis to determine which of the source spectra in the library best matches the measured activation data. Any measurement method used to identify a neutron source spectrum relies at some point on a comparison against known sources; no identification method is definitive. Detection systems measure some physical aspect of the source, not its serial number. Many systems measure the physical aspect to determine that the source has some property, and then leave it to experts to determine which potential sources share that property. The analysis system presented here incorporates the comparison into the analysis itself. The statistical tests show which of the known library sources match the measured data the best and whether that match is a good match. If the best match still does not fit the measured data well (a very high χ{sup 2} value), that indicates the true source is not one of the sources in the library. This is still valuable information for decision makers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PRACTICAL METHODS FOR CONTINUOUS GRAVITATIONAL WAVE DETECTION USING PULSAR TIMING DATA

Gravitational waves (GWs) are tiny ripples in the fabric of space time predicted by Einstein's general relativity. Pulsar timing arrays (PTAs) are well poised to detect low-frequency (10{sup -9}-10{sup -7} Hz) GWs in the near future. There has been a significant amount of research into the detection of a stochastic background of GWs from supermassive black hole binaries (SMBHBs). Recent work has shown that single continuous sources standing out above the background may be detectable by PTAs operating at a sensitivity sufficient to detect the stochastic background. The most likely sources of continuous GWs in the pulsar timing frequency band are extremely massive and/or nearby SMBHBs. In this paper we present detection strategies including various forms of matched filtering and power spectral summing. We determine the efficacy and computational cost of such strategies. It is shown that using an optimal matched filter explicitly including the poorly constrained pulsar distances with a grid-based method is computationally infeasible. We show that an Earth-term-matched filter constructed using only the correlated signal terms is robust, computationally viable and highly sensitive to GW signals. We further show that a simple power spectral summing technique is nearly equivalent to the Earth-term-matched filter in terms of the minimum detectable amplitude. Both of these techniques are only a factor of two less sensitive than the computationally unrealizable optimal matched filter. We also show that a pairwise matched filter, taking the pulsar distances into account, is comparable to the optimal matched filter for the single template case and comparable to the Earth-term-matched filter for many search templates. Finally, using simulated data optimal quality, we place a theoretical minimum detectable strain amplitude of h > 2 Multiplication-Sign 10{sup -15} from continuous GWs at frequencies on the order {approx}1/T{sub obs}.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward adaptive radiotherapy for head and neck patients: Uncertainties in dose warping due to the choice of deformable registration algorithm

Purpose: The aims of this work were to evaluate the performance of several deformable image registration (DIR) algorithms implemented in our in-house software (NiftyReg) and the uncertainties inherent to using different algorithms for dose warping. Methods: The authors describe a DIR based adaptive radiotherapy workflow, using CT and cone-beam CT (CBCT) imaging. The transformations that mapped the anatomy between the two time points were obtained using four different DIR approaches available in NiftyReg. These included a standard unidirectional algorithm and more sophisticated bidirectional ones that encourage or ensure inverse consistency. The forward (CT-to-CBCT) deformation vector fields (DVFs) were used to propagate the CT Hounsfield units and structures to the daily geometry for “dose of the day” calculations, while the backward (CBCT-to-CT) DVFs were used to remap the dose of the day onto the planning CT (pCT). Data from five head and neck patients were used to evaluate the performance of each implementation based on geometrical matching, physical properties of the DVFs, and similarity between warped dose distributions. Geometrical matching was verified in terms of dice similarity coefficient (DSC), distance transform, false positives, and false negatives. The physical properties of the DVFs were assessed calculating the harmonic energy, determinant of the Jacobian, and inverse consistency error of the transformations. Dose distributions were displayed on the pCT dose space and compared using dose difference (DD), distance to dose difference, and dose volume histograms. Results: All the DIR algorithms gave similar results in terms of geometrical matching, with an average DSC of 0.85 ± 0.08, but the underlying properties of the DVFs varied in terms of smoothness and inverse consistency. When comparing the doses warped by different algorithms, we found a root mean square DD of 1.9% ± 0.8% of the prescribed dose (pD) and that an average of 9% ± 4% of voxels within the treated volume failed a 2%pD DD-test (DD{sub 2%-pp}). Larger DD{sub 2%-pp} was found within the high dose gradient (21% ± 6%) and regions where the CBCT quality was poorer (28% ± 9%). The differences when estimating the mean and maximum dose delivered to organs-at-risk were up to 2.0%pD and 2.8%pD, respectively. Conclusions: The authors evaluated several DIR algorithms for CT-to-CBCT registrations. In spite of all methods resulting in comparable geometrical matching, the choice of DIR implementation leads to uncertainties in dose warped, particularly in regions of high gradient and/or poor imaging quality.

60 APPLIED LIFE SCIENCES↗

Geospatial-Temporal Semantic Graphs for Automated Wide-Area Search

We address the problem of wide-area search of overhead imagery. Given a time sequence of overhead images, we construct a geospatial-temporal semantic graph, which expresses the complex continuous information in the overhead images in a discrete searchable form, including explicit modeling of changes seen from one image to the next. We can then express desired search goals as a template graph, and search for matches using simple and efficient graph search algorithms. This produces a set of potential matches which provide cues for where to examine the imagery in detail, applying human expertise to determine which matches are correct. We include a match quality metric that scores the matches according to how well they match the stated search goal. This enables matches to be presented in sorted order with the best matches first, similar to the results returned by a web search engine. We present an evaluation of the method applied to several examples and data sets, and show that it can be used successfully for some problems. We also remark on several limitations of the method and note additional work needed to improve its scope and robustness. Approved for public release; further dissemination unlimited.

97 MATHEMATICS AND COMPUTING↗

1–2.4 μm Near-IR Spectrum of the Giant Planet β Pictoris b Obtained with the Gemini Planet Imager

Using the Gemini Planet Imager located at Gemini South, we measured the near-infrared (1.0–2.4 μm) spectrum of the planetary companion to the nearby, young star β Pictoris. We compare the spectrum obtained with currently published model grids and with known substellar objects and present the best matching models as well as the best matching observed objects. Comparing the empirical measurement of the bolometric luminosity to evolutionary models, we find a mass of 12.9 ± 0.2 M{sub Jup}, an effective temperature of 1724 ± 15 K, a radius of 1.46 ± 0.01 R{sub Jup}, and a surface gravity of logg=4.18±0.01 [dex] (cgs). The stated uncertainties are statistical errors only, and do not incorporate any uncertainty on the evolutionary models. Using atmospheric models, we find an effective temperature of 1700–1800 K and a surface gravity of logg=3.5–4.0 [dex] depending upon the model. These values agree well with other publications and with “hot-start” predictions from planetary evolution models. Further, we find that the spectrum of β Pic b best matches a low surface gravity L2 ± 1 brown dwarf. Finally, comparing the spectrum to field brown dwarfs, we find the the spectrum best matches 2MASS J04062677–381210 and 2MASS J03552337+1133437.

79 ASTRONOMY AND ASTROPHYSICS↗