Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ML”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Explainable AI classification for parton density theory

Quantitatively connecting properties of parton distribution functions (PDFs, or parton densities) to the theoretical assumptions made within the QCD analyses which produce them has been a longstanding problem in HEP phenomenology. To confront this challenge, we introduce an ML-based explainability framework, XAI4PDF, to classify PDFs by parton flavor or underlying theoretical model using ResNet-like neural networks (NNs). By leveraging the differentiable nature of ResNet models, this approach deploys guided backpropagation to dissect relevant features of fitted PDFs, identifying x-dependent signatures of PDFs important to the ML model classifications. By applying our framework, we are able to sort PDFs according to the analysis which produced them while constructing quantitative, human-readable maps locating the x regions most affected by the internal theory assumptions going into each analysis. This technique expands the toolkit available to PDF analysis and adjacent particle phenomenology while pointing to promising generalizations.

Artificial Intelligence↗

Data-driven high-dimensional statistical inference with generative models

Crucial to many measurements at the LHC is the use of correlated multi-dimensional information to distinguish rare processes from large backgrounds, which is complicated by the poor modeling of many of the crucial backgrounds in Monte Carlo simulations. In this work, we introduce HI-SIGMA, a method to perform unbinned high-dimensional statistical inference with data-driven background distributions. In contradistinction to many applications of Simulation Based Inference in High Energy Physics, HI-SIGMA relies on generative ML models, rather than classifiers, to learn the signal and background distributions in the high-dimensional space. These ML models allow for interpretable inference while also incorporating model errors and other sources of systematic uncertainties. We showcase this methodology on a simplified version of a di-Higgs measurement in the bbγγ final state, where the di-photon resonance allows for background interpolation from sidebands into the signal region. We demonstrate that HI-SIGMA provides improved sensitivity as compared to standard classifier-based methods, and that systematic uncertainties can be straightforwardly incorporated by extending methods which have been used for histogram based analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preoperative Uterine Artery Embolization (PUAE) Before Uterine Fibroid Myomectomy

Purpose. To evaluate the potential of uterine artery embolization to minimize blood loss and facilitate easier removal of fibroids during subsequent myomectomy. Methods. This retrospective study included 22 patients (median age 37 years), of whom at least 15 wished to preserve their fertility. They presented with at least one fibroid (mean diameter 85.6 mm) and had undergone preoperative uterine artery embolization (PUAE) with resorbable gelatin sponge. Results. No complication or technical failure of embolization was identified. Myomectomies were performed during laparoscopy (12 cases) and laparotomy (9 cases). One hysterectomy was performed. The following were noted: easier dissection of fibroids (mean 5.6 per patient, range 1-30); mean intervention time 113 min (range 25-210 min); almost bloodless surgery, with a mean peroperative blood loss of 90 ml (range 0-806 ml); mean hemoglobin pretherapeutically 12.3 g/dl (range 5.9-15.2 g/dl) and post-therapeutically 10.3 g/dl (range 5.6-13.3 g/dl), with no blood transfusion needed. Patients were discharged on day 4 on average and the mean sick leave was 1 month. Conclusion. Preoperative embolization is associated with minimal intraoperative blood loss. It does not increase the complication rate or impair operative dissection, and improves the chances of performing conservative surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Saphenous Venous Ablation with Hot Contrast in a Canine Model

Purpose. To determine the feasibility, efficacy, and safety of thermal ablation of the saphenous vein with hot contrast medium. Methods. Twelve saphenous veins of 6 dogs were percutaneously ablated with hot contrast medium. In all animals, ablation was performed in the vein of one leg, followed by ablation in the contralateral side 1 month later. An occlusion balloon catheter was placed in the infragenicular segment of the saphenous vein via a jugular access to prevent unwanted thermal effects on the non-target segment of the saphenous vein. After inflation of the balloon, 10 ml of hot contrast medium was injected under fluoroscopic control through a sheath placed in the saphenous vein above the ankle. A second 10 ml injection of hot contrast medium was made after 5 min in each vessel. Venographic follow-up of the ablated veins was performed at 1 month (n = 12) and 2 months (n = 6). Results. Follow-up venograms showed that all ablated venous segments were occluded at 1 month. In 6 veins which were followed up to 2 months, 4 (66%) remained occluded, 1 (16%) was partially patent, and the remaining vein (16%) was completely patent. In these latter 2 cases, an inadequate amount of hot contrast was delivered to the lumen due to a closed balloon catheter downstream which did not allow contrast to displace blood within the vessel. Discussion. Hot contrast medium thermal ablation of the saphenous vein appears feasible, safe, and effective in the canine model, provided an adequate amount of embolization agent is used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gadolinium Use in Spine Pain Management Procedures for Patients with Contrast Allergies: Results in 527 Procedures

Introduction. To review the safety and efficacy of gadolinium in spine pain management procedures in patients at high risk for a contrast reaction and who are not suitable candidates for the use of standard non-ionic contrast. Methods. We reviewed records over a 61-month period of all image-guided spinal pain management procedures where patients had allergies making them unsuitable candidates for standard non-ionic contrast and where gadolinium was used to confirm needle tip placement prior to injection of medication. Results. Three hundred and four outpatients underwent 527 procedures. A spinal needle was used in all but 41 procedures. Gadolinium was visualized using portable C-arm fluoroscopy in vivo allowing for confirmation of needle tip location. The gadolinium dose ranged from 0.2 to 10 ml per level. The highest dose received by one patient was 15.83 ml intradiscally during a three-level discogram. Three hundred and one patients were discharged without complication or known delayed complications. One patient had documented intrathecal injection but without sequelae and 2 patients who underwent cervical procedures experienced seizures requiring admission to the intensive care unit. Both the latter patients were discharged without any further complications. Conclusion. Based on our experience we recommend using gadolinium judiciously for needle tip confirmation. We feel more confident using gadolinium in the lumbar spine and in cervical nerve blocks. Gadolinium should probably not be used as an injectate volume expander. The indications for gadolinium use in cervical needle-guided spine procedures are less clear and use of a blunt-tipped needle should be considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Minimally Invasive Therapy of Pseudoaneurysms of the Trunk: Application of Thrombin

Thrombin injection has been proven to be successful in postcatheterization pseudoaneurysms. However, there are only a few reports on the treatment of pseudoaneurysms of the trunk. We report our first experiences using a percutaneous as well as an endovascular access. Eight iatrogenic pseudoaneurysms of the trunk (aorta, n = 4; pulmonary artery, n = 1; gastroduodenal artery, n = 1; left gastric artery, n = 1, renal artery, n = 1) were treated either percutaneously using CT guidance (n = 3) or via an endovascular access (n = 5). Noninvasive control angiograms were performed at day 1 and weeks 1 and 3 by either CT or MR angiography. The total volume of the pseudoaneurysms was 31.2 {+-} 23.1 ml on average, with a mean volume of the perfused aneurysmal lumen of 12.9 {+-} 7.2 ml. The maximum diameter was 4.1 {+-} 1.39 cm on average. In each case, the aneurysmal neck was not wider than 2 mm. One pseudoaneurysm occluded spontaneously following selective catheterization. The remaining pseudoaneurysms were successfully treated by injection of 765 {+-} 438.1 IU thrombin. In one individual, a nontarget embolization occurred, as well as an intervention-associated rupture of a pseudoaneurysm. High-grade stenoses of the donor artery were found in a different case. Only once was the endoluminal access converted to a percutaneous one. Thrombin injection might be a future first-line treatment of vascular lesions such as pseudoaneurysms of the trunk. In our experience both percutanous and endoluminal access are technically feasible and safe. However, further experiences are mandatory, especially concerning the question of dosage and long-term results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of Extraspinal Painful Bone Metastases with Percutaneous Cementoplasty: A Prospective Study of 50 Patients

The aim of this study was to assess the efficacy of percutaneous cementoplasty (PC) with polymethylmethacrylate (PMMA) in painful extravertebral lytic bone metastases not responding to conventional therapy. Fifty patients (25 females), mean age 64.7 {+-} 11.2 years, underwent PC after giving informed consent. Procedures were performed under fluoroscopy (1/50) or combined fluoroscopy-CT (49/50) guidance in local anesthesia or under deep sedation in 7 patients with large metastases who underwent radiofrequency thermoablation (RFA) in the same session. Seventy lesions were treated (1-6 per patient; average, 1.4 {+-} 0.9), arranging in size from 1 to 10 cm (average, 3.6 {+-} 2.1 cm). Mean volume of PMMA per lesion was 5.9 {+-} 3.2 ml (range, 1.5-15.0 ml). Pain was prospectively evaluated on an 11-point visual analog scale (VAS) before and after the procedure (follow-up, 15 to 36 months). Mean VAS score dropped from 9.1 {+-} 1.2 (range: 6-10) to 2.1 {+-} 2.5 (range: 0-9). Mean VAS difference was 7.0 {+-} 2.3 (range, 1-10; p < 0.0001, Wilcoxon signed rank test). Forty-seven of the 50 patients (94%) suspended narcotic drugs, in 22 (44%) pain was controlled with a nonsteroidal anti-inflammatory drug, in 25 (50%) analgesic therapy was suspended, and 13 of 50 (26%) had complete pain regression. In 3 of the 50 patients (6%) pain was not improved. No statistical difference between osteoplasty and osteoplasty plus RFA was found (p = 0.8338, Mann-Whitney test). No complications arose during the procedure. Two patients with metastases in the femoral diaphysis reported a fracture 1 month after treatment. PC is effective to obtain pain regression in painful bone metastases not responding to conventional analgesic therapy; bone consolidation cannot be obtained in the diaphysis of long weight-bearing bones.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR Venography of Deep Veins: Changes with Uterine Fibroid Embolization

Deep veins (DVs) can be compressed by a uterus enlarged with fibroids. The purpose of this study was to assess the degree of luminal narrowing of DVs caused by a myomatous uterus, and the change in DV narrowing in women with symptomatic fibroids after embolization using time-of-flight (TOF)-magnetic resonance venography (MRV). Twenty-nine consecutive women with symptomatic uterine fibroids underwent TOF-MRV and pelvic MRI before and 4 months after embolization. Based on the TOF-MRV, we evaluated the luminal narrowing of three DVs, including the inferior vena cava, and the bilateral common and external iliac veins, and divided the findings into three grades. The scores for each DV were added for each patient (lowest, 0; highest, 6). DV scores and symptom severity (SS) scores were compared between the baseline and 4 months after embolization using the paired t-test. The relationship between DV scores and uterine volume was investigated using Pearson's test. DV scores decreased significantly, from 1.52 {+-} 1.70 at baseline to 0.93 {+-} 1.56 at 4 months after embolization (p = 0.004). The uterine volume decreased from 948 {+-} 647 mL at baseline to 617 {+-} 417 mL at 4 months after embolization (p < 0.001). DV score correlated with uterine volume (r = 0.856, p < 0.001). SS scores decreased from 54.5 {+-} 14.6 at baseline to 26.8 {+-} 15.4 at 4 months after embolization (p < 0.001). In conclusion, the degree of luminal narrowing of DVs caused by a uterus with fibroids is correlated with the uterine volume. Uterine artery embolization may induce an improvement of luminal narrowing of DVs due to a reduction of the myomatous uterus volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal Protection During Percutaneous Thermal Ablation Procedures: Interest of Carbon Dioxide Dissection and Temperature Monitoring

Percutaneous image-guided thermal ablation of tumor is widely used, and thermal injury to collateral structures is a known complication of this technique. To avoid thermal damage to surrounding structures, several protection techniques have been reported. We report the use of a simple and effective protective technique combining carbon dioxide dissection and thermocouple: CO{sub 2} displaces the nontarget structures, and its low thermal conductivity provides excellent insulation; insertion of a thermocouple in contact with vulnerable structures achieves continuous thermal monitoring. We performed percutaneous thermal ablation of 37 tumors in 35 patients (4 laser, 10 radiofrequency, and 23 cryoablations) with protection of adjacent vulnerable structures by using CO{sub 2} dissection combined with continuous thermal monitoring with thermocouple. Tumor locations were various (19 intra-abdominal tumors including 4 livers and 9 kidneys, 18 musculoskeletal tumors including 11 spinal tumors). CO{sub 2} volume ranged from 10 ml (epidural space) to 1500 ml (abdominal). Repeated insufflations were performed if necessary, depending on the information given by the thermocouple and imaging control. Dissection with optimal thermal protection was achieved in all cases except two patients where adherences (one postoperative, one arachnoiditis) blocked proper gaseous distribution. No complication referred to this technique was noted. This safe, cost-effective, and simple method increases the safety and the success rate of percutaneous thermal ablation procedures. It also offers the potential to increase the number of tumors that can be treated via a percutaneous approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pure Ethiodized Oil-based Transcatheter Ablative Therapy in Normal Rabbit Kidneys and Kidneys Inoculated with VX-2 Carcinoma

Purpose: To evaluate the efficacy of ablation with selective arterial injection of pure ethiodized oil followed by arterial occlusion with 9:1 ethanol-Ethiodol mixture (EEM) and coil placement in normal rabbit kidneys and kidneys inoculated with VX-2 carcinoma. Materials and Methods: All experiments were conducted with Animal Care and Use Committee approval. In six rabbits (group 1), one kidney was embolized with pure Ethiodol until capillary stasis, followed by injection of 9:1 EEM until arterial stasis and then coil placement into the main renal artery. In 12 other rabbits, one kidney was inoculated with VX-2 tumor. Ethiodol and EEM embolization and coil placement followed 7 days later (group 2, n = 6) or 11-14 days later (group 3, n = 6). Kidneys were evaluated (angiography, computed tomography, macro- and microscopy) 7 days after treatment. Results: Capillary stasis was achieved in groups 1, 2, and 3 with (mean {+-} standard deviation) 0.47 {+-} 0.03, 0.53 {+-} 0.02, and 0.56 {+-} 0.04 ml of pure Ethiodol, followed by 0.47 {+-} 0.05, 0.42 {+-} 0.03, and 0.38 {+-} 0.04 ml of EEM, respectively, which caused complete arterial occlusion in 17 of 18 kidneys. In group 1, all but one kidney showed at least 95% generalized coagulative necrosis. In group 2, all six kidneys exhibited 100% coagulative necrosis, with no viable tumor present. In group 3, 100% coagulative necrosis was present in all kidneys, with a small viable tumor in one. Conclusion: In the rabbit, selective arterial injection of pure Ethiodol can cause complete renal parenchyma and tumor ablation when it is followed by prompt, contiguous, and permanent occlusion of the arterial compartment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Burden of Hard Atherosclerotic Plaques Does Not Promote Endoleak Development After Endovascular Aortic Aneurysm Repair: A Risk Stratification

Purpose: To objectify the influence of the atherosclerotic burden in the proximal landing zone on the development of endoleaks after endovascular abdominal aortic aneurysm repair (EVAR) or thoracic endovascular aneurysm repair (TEVAR) using objective aortic calcium scoring (ACS). Materials and Methods: This retrospective observation study included 267 patients who received an aortic endograft between 1997 and 2010 and for whom preoperative computed tomography (CT) was available to perform ACS using the CT-based V600 method. The mean follow-up period was 2 {+-} 2.3 years. Results: Type I endoleaks persisted in 45 patients (16.9%), type II in 34 (12.7%), type III in 8 (3%), and type IV or V in 3 patients, respectively (1.1% each). ACS in patients with type I endoleaks was not increased: 0.029 {+-} 0.061 ml compared with 0.075 {+-} 0.1349 ml in the rest of the patients, (p > 0.05; Whitney-Mann U-Test). There were significantly better results for the indication 'traumatic aortic rupture' than for the other indications (p < 0.05). In multivariate logistic regression analyses, age was an independent risk factor for the development of type I endoleaks in the thoracic aorta (Wald 9.5; p = 0.002), whereas ACS score was an independent protective factor (Wald 6.9; p = 0.009). In the abdominal aorta, neither age nor ACS influenced the development of endoleaks. Conclusion: Contrary to previous assumptions, TEVAR and EVAR can be carried out without increasing the risk of an endoleak of any type, even if there is a high atherosclerotic 'hard-plaque' burden of the aorta. The results are significantly better for traumatic aortic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Pilot Study of Uterine Artery Embolization with Tris-Acryl Gelatin Microspheres in Guinea Pigs

Objective: This study was designed to establish guinea pigs as an animal model for uterine artery embolization (UAE) with tris-acryl gelatin microspheres (TAGM). Methods: Twenty-five female adult guinea pigs were randomly divided into two groups, including a uterine artery casting mould group (n = 10) and a UAE group (n = 15). Pelvic angiography and vascular casting mould were performed in the first group. The anatomical characters of the pelvic cavity in guinea pigs were described. In the second group, the technical feasibility of performing UAE with TAGM in guinea pigs was investigated. The histopathological slides of the uterus of guinea pigs after UAE were examined to inspect the outcomes of UAE. Results: The uterine artery springs from the internal iliac artery, ascends tortuously along the cervix, and gives off vertically 8-10 branches to the cervix uteri and uterine horns. The diameters of the trunk of the uterine artery and its first branch were 0.32 {+-} 0.027 mm and 0.14 {+-} 0.01 mm, respectively. For UAE animals, the dosages of 40-120 and 100-300 {mu}m TAGM were 0.033 {+-} 0.003 ml and 0.015 {+-} 0.002 ml, respectively. On histopathological slides, embosphere particles were found in the first branches of the uterine artery, the subserous arteries, and the intramural arteries. Inflammatory reactions in the uterus were common in guinea pigs after UAE. Local or dispersed areas of necrosis in uterus also were observed in a few guinea pigs. Conclusions: Guinea pigs are an appropriate and feasible model for UAE with TAGM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computed Tomography-Guided Interstitial HDR Brachytherapy (CT-HDRBT) of the Liver in Patients with Irresectable Intrahepatic Cholangiocarcinoma

Purpose: This study was designed to investigate the clinical outcome of patients with irresectable, intrahepatic cholangiocarcinoma (IHC) treated with computed tomography (CT)-guided HDR-brachytherapy (CT-HDRBT) for local tumor ablation.MethodFifteen consecutive patients with histologically proven cholangiocarcinoma were selected for this retrospective study. Patients were treated by high-dose-rate internal brachytherapy (HDRBT) using an Iridium-192 source in afterloading technique through CT-guided percutaneous placed catheters. A total of 27 brachytherapy treatments were performed in these patients between 2006 and 2009. Median tumor enclosing target dose was 20 Gy, and mean target volume of the radiated tumors was 131 ({+-} 90) ml (range, 10-257 ml). Follow-up consisted of clinical visits and magnetic resonance imaging of the liver every third month. Statistical evaluation included survival analysis using the Kaplan-Meier method. Results: After a median follow-up of 18 (range, 1-27) months after local ablation, 6 of the 15 patients are still alive; 4 of them did not get further chemotherapy and are regarded as disease-free. The reached median local tumor control was 10 months; median local tumor control, including repetitive local ablation, was 11 months. Median survival after local ablation was 14 months and after primary diagnosis 21 months. Conclusion: In view of current clinical data on the clinical outcome of cholangiocarcinoma, locally ablative treatment with CT-HDRBT represents a promising and safe technique for patients who are not eligible for tumor resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Discomanometry: Correlation of Intradiscal Pressure Values to Pain Reduction in Patients With Intervertebral Disc Herniation Treated With Percutaneous, Minimally Invasive, Image-Guided Techniques

Purpose: To illustrate quantitative discomanometry's (QD) diagnostic efficacy and predictive value in discogenic-pain evaluation in a prospective study correlating intradiscal pressure values with pain reduction after percutaneous image-guided technique (i.e., percutaneous decompression, PD). Materials and Methods: During the last 3 years, 36 patients [21 male and 15 female (mean age 36 {+-} 5.8 years)] with intervertebral disc hernia underwent QD before PD. Under absolute sterilization and fluoroscopy, a mixture of contrast medium and normal saline (3:1 ratio) was injected. A discmonitor performed a constant rate injection and recorded pressure and volume values, thus producing the relative pressure-volume curve. PD was then performed. Pain reduction and improved mobility were recorded at 3, 12, and 24 months after PD using clinical evaluation and a numeric visual scale (NVS; 0 to 10 units). Results: Mean pain values of 7.5 {+-} 1.9 (range 4 to 8) NVS units were recorded before PD; these decreased to 2.9 {+-} 2.44 at 3 months, 1.0 {+-} 1.9 at 12 months, and 1.0 {+-} 1.9 NVS units at 24 months after PD. Recorded correlations (pressure, volume, significant pain-reduction values) with bilateral statistical significance included a maximum injected volume of 2.4 ml (p = 0.045), P{sub o} < 14 psi [initial pressure required to inject 0.1 ml of the mixture inside the disc (p = 0.05)], P{sub max} {<=} 65 psi [greatest pressure value on the curve (p = 0.018)], and P{sub max} - P{sub o} {<=} 47 psi (p = 0.038). Patients meeting these pressure or volume cut-off points, either independently or as a total, had significant pain reduction (>4 NVS units) after PD. No complications were noted. Conclusions: QD is an efficient technique that may have predictive value for discogenic pain evaluation. It might serve as a useful tool for patient selection for intervertebral disc therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids

Purpose: To report the first clinical experience with targeted vessel ablation during magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) treatment of symptomatic uterine fibroids. Methods: Pretreatment T1-weighted contrast-enhanced magnetic resonance angiography was used to create a detailed map of the uterine arteries and feeding branches to the fibroids. A three-dimensional overlay of the magnetic resonance angiography images was registered on 3D T2-weighted pretreatment imaging data. Treatment was focused primarily on locations where supplying vessels entered the fibroid. Patients were followed 6 months after treatment with a questionnaire to assess symptoms and quality of life (Uterine Fibroid Symptom and Quality of Life) and magnetic resonance imaging to quantify shrinkage of fibroid volumes. Results: In two patients, three fibroids were treated with targeted vessel ablation during MR-HIFU. The treatments resulted in almost total fibroid devascularization with nonperfused volume to total fibroid volume ratios of 84, 68, and 86%, respectively, of treated fibroids. The predicted ablated volumes during MR-HIFU in patients 1 and 2 were 45, 40, and 82 ml, respectively, while the nonperfused volumes determined immediately after treatment were 195, 92, and 190 ml respectively, which is 4.3 (patient 1) and 2.3 (patient 2) times higher than expected based on the thermal dose distribution. Fibroid-related symptoms reduced after treatment, and quality of life improved. Fibroid volume reduction ranged 31-59% at 6 months after treatment. Conclusion: Targeted vessel ablation during MR-HIFU allowed nearly complete fibroid ablation in both patients. This technique may enhance the use of MR-HIFU for fibroid treatment in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postpartum Hemorrhage Treated with Gelfoam Slurry Embolization Using the Superselective Technique: Immediate Results and 1-Month MRI Follow-up

To evaluate the efficacy and safety of superselective embolization of the uterine arteries in a postpartum hemorrhage. Between November 2004 and January 2011, a total of 44 consecutive women (median {+-} standard deviation age 34 {+-} 3 years, range 23-41 years) were referred to our institution for postpartum intractable hemorrhage management. All patients were embolized with a microcatheter that was placed deep into the uterine arteries upstream of the cervical arteries. The embolic agent was a mixture of contrast medium and 5 Multiplication-Sign 5 Multiplication-Sign 5 cm pieces of gelfoam (Gelita-Spon) modified into a gelatin emulsion as follows: rapid mixing through a three-way stopcock with two 2.5-ml syringes. A 1-ml syringe was used for injection. One month after embolization, all patients underwent magnetic resonance imaging and clinical examination. Technical and clinical success was obtained in all cases. Thirty-five patients experienced bleeding related to poor retraction of the uterus, 7 patients because of a tear of the cervix and 2 because of a vaginal hematoma. Pre- and postembolization red blood cell transfusions were (mean {+-} standard deviation [SD]) 6 {+-} 1.2 (range 3-8) U and 2 {+-} 0.7 (range 2-4) U, respectively. One-month magnetic resonance imaging follow-up revealed no sign of ischemic myometrium or necrosis, and no instances of uterine rupture and no pelvic vein thrombosis. Incidental findings included two small intramyometrial hematic collections. All uterine arteries were patent via magnetic resonance angiography. Seventeen patients had concomitant fibroids, all of which appeared hypovascular. This technique permits good, safe clinical results with no marked damage to the uterine arteries or the uterus itself.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Short-Term Effects of Ankaferd Hemostat for Renal Artery Embolization: An Experimental Study

Renal artery embolization (RAE) is a minimally invasive therapeutic technique that is utilized in a number of disorders. Ankaferd is a novel hemostatic agent with a new mechanism of action independent of clotting factors. We used Ankaferd for RAE in a sheep model. Seven adult female sheep were included in the study. Selective renal arteriogram using 5-F diagnostic catheter was performed to make sure that each kidney was fed by a single renal artery and the animal had normal renal vasculature. Coaxial 2.7-F microcatheter was advanced to the distal main renal artery. Under fluoroscopic guidance, 2 mL of Ankaferd mixed with 2 mL of nonionic iodinated contrast agent was slowly injected. Fluoroscopy was used to observe the deceleration of flow and stagnation. Control renal angiograms were performed just after embolization. After the procedure, the animals were observed for 1 day and then sacrificed with intravenous sodium thiopental. The technical success was observed in seven of the seven animals.. After embolization procedure, none of the animals died or experienced a major systemic adverse event. On macroscopic examination of the embolized kidneys, thrombus at the level of main renal artery formed after Ankaferd embolization was more compact compared with the thrombi that was not Ankaferd-associated, which was observed elsewhere. Microscopically, majority of the renal tubular cells (80-90 %) were necrotic, and there was epithelial cell damage in a small portion of the cells (10-20 %). RAE was safe and effective in the short-term with Ankaferd in studied animals. Further studies should be conducted to better delineate the embolizing potential of this novel hemostatic agent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Incompatibility of Contrast Medium and Trisodium Citrate

To test the compatibility of trisodium citrate, a catheter lock solution, with iodinated contrast medium. Iohexol, iobitridol, iodixanol, ioxaglate, ioxithalamate, iomeprol, and iopromide were tested. In all tests, 2 ml of contrast medium were mixed with 2 ml of trisodium citrate solution. Iodixanol and ioxaglate provoked a highly viscous gluelike precipitation when mixed with trisodium citrate. A brief transient precipitate was observed with iohexol, iomeprol, and ioxithalamate. Permanent precipitation occurred with iobitridol and iopromide. One must be aware of the potential for precipitation when contrast medium is mixed with trisodium citrate solution. Before trisodium citrate solution is injected, the catheter should be thoroughly flushed with saline if a contrast medium has previously been injected through it.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗