Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Construction and development of a time-resolved x-ray magnetic circular dichroism-photoelectron emission microscopy system using femtosecond laser pulses at BL25SU SPring-8

A femtosecond pulsed laser system has been installed at the BL25SU soft x-ray beamline at SPring-8 for time-resolved pump-probe experiments with synchronization of the laser pulses to the circularly polarized x-ray pulses. There are four different apparatuses situated at the beamline; for photoemission spectroscopy, two-dimensional display photoelectron diffraction, x-ray magnetic circular dichroism (XMCD) with electromagnetic coils, and photoelectron emission microscopy (PEEM). All four can be used for time-resolved experiments, and preliminary investigations have been carried out using the PEEM apparatus to observe magnetization dynamics in combination with XMCD. In this article, we describe the details of the stroboscopic pump-probe XMCD-PEEM experiment, and present preliminary data. The repetition rate of the laser pulses is set using a pulse selector to match the single bunches of SPring-8's hybrid filling pattern, which consists of several single bunches and a continuous bunch train. Electrons ejected during the bunch train, which do not provide time-resolved signal, are eliminated by periodically reducing the channel plate voltage using a custom-built power supply. The pulsed laser is used to create 300 ps long magnetic field pulses, which cause magnetic excitations in micron-sized magnetic elements which contain magnetic vortex structures. The observed frequency of the motion is consistent with previously reported observations and simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetostatic focal spot correction for x-ray tubes operating in strong magnetic fields using iterative optimization

Purpose: Combining x-ray fluoroscopy and MR imaging systems for guidance of interventional procedures has become more commonplace. By designing an x-ray tube that is immune to the magnetic fields outside of the MR bore, the two systems can be placed in close proximity to each other. A major obstacle to robust x-ray tube design is correcting for the effects of the magnetic fields on the x-ray tube focal spot. A potential solution is to design active shielding that locally cancels the magnetic fields near the focal spot. Methods: An iterative optimization algorithm is implemented to design resistive active shielding coils that will be placed outside the x-ray tube insert. The optimization procedure attempts to minimize the power consumption of the shielding coils while satisfying magnetic field homogeneity constraints. The algorithm is composed of a linear programming step and a nonlinear programming step that are interleaved with each other. The coil results are verified using a finite element space charge simulation of the electron beam inside the x-ray tube. To alleviate heating concerns an optimized coil solution is derived that includes a neodymium permanent magnet. Any demagnetization of the permanent magnet is calculated prior to solving for the optimized coils. The temperature dynamics of the coil solutions are calculated using a lumped parameter model, which is used to estimate operation times of the coils before temperature failure. Results: For a magnetic field strength of 88 mT, the algorithm solves for coils that consume 588 A/cm{sup 2}. This specific coil geometry can operate for 15 min continuously before reaching temperature failure. By including a neodymium magnet in the design the current density drops to 337 A/cm{sup 2}, which increases the operation time to 59 min. Space charge simulations verify that the coil designs are effective, but for oblique x-ray tube geometries there is still distortion of the focal spot shape along with deflections of approximately 3 mm in the radial and circumferential directions on the anode. Conclusions: Active shielding is an attractive solution for correcting the effects of magnetic fields on the x-ray focal spot. If extremely long fluoroscopic exposure times are required, longer operation times can be achieved by including a permanent magnet with the active shielding design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hyperfine field and magnetic structure in the B phase of CeCoIn5

We re-analyze Nuclear Magnetic Resonance (NMR) spectra observed at low temperatures and high magnetic fields in the field-induced B-phase of CeCoIn{sub 5}. The NMR spectra are consistent with incommensurate antiferromagnetic order of the Ce magnetic moments. However, we find that the spectra of the In(2) sites depend critically on the direction of the ordered moments, the ordering wavevector and the symmetry of the hyperfine coupling to the Ce spins. Assuming isotropic hyperfine coupling, the NMR spectra observed for H {parallel} [100] are consistent with magnetic order with wavevector Q = {pi}(1+{delta}/a, 1/a, 1/c) and Ce moments ordered antiferromagnetically along the [100] direction in real space. If the hyperfine coupling has dipolar symmetry, then the NMR spectra require Ce moments along the [001] direction. The dipolar scenario is also consistent with recent neutron scattering measurements that find an ordered moment of 0.15{micro}{sub B} along [001] and Q{sub n} = {pi}(1+{delta}/a, 1+{delta}c, 1/c) with incommensuration {delta} = 0.12 for field H {parallel} [1{bar 1}0]. Using these parameters, we find that the hyperfine field is consistent with both experiments. We speculate that the B phase of CeCoIn{sub 5} represents an intrinsic phase of modulated superconductivity and antiferromagnetism that can only emerge in a highly clean system.

47 OTHER INSTRUMENTATION↗

Use of a synchronization card for XMCD measurements at the XMaS Beamline

X-ray Magnetic Circular Dichroism (XMCD) spectra from a 5 {mu}m polycrystalline Gd foil were measured in transmission across the Gd L{sub 2,3} edges using the Multipurpose Unit for Synchronisation, Sequencing and Triggering (MUSST) card developed at the European Synchrotron Radiation Facility (ESRF). The circularly polarized x-rays were produced by a diamond phase-plate and their helicity was rapidly reversed through the use of a piezo driven device. The signal measured for each helicity was recorded by the MUSST card synchronized to the helicity reversal. The results are compared to those obtained using an analogue lock-in technique.

43 PARTICLE ACCELERATORS↗

Reconstructing magnetic deflections from sets of proton images using differential evolution

Proton imaging is a powerful technique for imaging electromagnetic fields within an experimental volume, in which spatial variations in proton fluence are a result of deflections to proton trajectories due to interaction with the fields. When deflections are large, proton trajectories can overlap, and this nonlinearity creates regions of greatly increased proton fluence on the image, known as caustics. The formation of caustics has been a persistent barrier to reconstructing the underlying fields from proton images. We have developed a new method for reconstructing the path-integrated magnetic fields, which begins to address the problem posed by caustics. Our method uses multiple proton images of the same object, each image at a different energy, to fill in the information gaps and provide some uniqueness when reconstructing caustic features. We use a differential evolution algorithm to iteratively estimate the underlying deflection function, which accurately reproduces the observed proton fluence at multiple proton energies simultaneously. We test this reconstruction method using synthetic proton images generated for three different, cylindrically symmetric field geometries at various field amplitudes and levels of proton statistics and present reconstruction results from a set of experimental images. Here, the method we propose requires no assumption of deflection linearity and can reliably solve for fields underlying linear, nonlinear, and caustic proton image features for the selected geometries and is shown to be fairly robust to noise in the input proton intensity.

47 OTHER INSTRUMENTATION↗

Dark Matter Indirect Search: The PAMELA Experiment

The instrument PAMELA, in orbit since June 15th, 2006, on board the Russian satellite Resurs DK1, is daily delivering to ground 16 Gigabytes of data. The apparatus is designed to study charged particles in the cosmic radiation, with a particular focus on antiparticles for searching antimatter and signals of dark matter annihilation. A combination of a magnetic spectrometer and different detectors allows antiparticles to be reliably identified from a large background of other charged particles. New results on the antiproton-to-proton and positron-to-all electron ratios over a wide energy range (1-100 GeV) are presented. While the antiproton-to-proton ratio does not show significant differences from standard secondary production, in the positron-to-all electron ratio an enhancement is clearly seen at energies above 10 GeV. Possible interpretations of this effect are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Magnetospheric Multiscale Ion Jet Signatures with Predicted Reconnection Site Locations at the Magnetopause

Magnetic reconnection at the Earths magnetopause is the primary process by which solar wind plasma and energy gains access to the magnetosphere. One indication that magnetic reconnection is occurring is the observation of accelerated plasma as a jet tangential to the magnetopause. The direction of ion jets along the magnetopause surface as observed by the Fast Plasma Instrument (FPI) and the Hot Plasma Composition Analyzer (HPCA) instrument on board the recently launched Magnetospheric Multiscale (MMS) set of spacecraft is examined. For those cases where ion jets are clearly discerned, the direction of origin compares well statistically with the predicted location of magnetic reconnection using convected solar wind observations in conjunction with the Maximum Magnetic Shear model.

Petrinec, S. M.↗

Energetic charged particles in the Uranian magnetosphere

The cosmic ray instrument on Voyager 2 obtained detailed charged particle data on the path the spacecraft followed through the newly-discovered Uranian magnetosphere. Notably, the electron counts did not rise above background until the spacecraft was deep in the magnetosphere. The data further indicated that the satellites Miranda, Ubriel and Ariel impose a sweep effect on MeV electrons, which move radially inward from some source in the outer magnetosphere or the magnetotail. The energetic particle data also supported a firm pitch angle dependence for proton energy spectra in the 1-8 MeV range. Finally, the particle density data were commensurate with a dipole magnetic field tilted 60.1 deg in relation to the planet and rotating every 17.4 hr, close to estimates from other instruments.

Stone, E. C.↗

Can MARSIS Measure the Low-Altitude Components of the Mars Magnetic Field?

Measuring the magnetic field anomaly of Mars at low altitudes (e.g. 100-200 km) can be an interesting application of Mars Advance Radar for Subsurface and Ionospheric Sounder (MARSIS). Due to a low HF operation frequency, the radio wave propagating in the ionosphere of Mars, over the magnetic anomaly regions, will be affected and distorted by the localized magnetic field. This distortion in the sounder signal is due to the Faraday rotation and provides information about the strength of the magnetic field. MARSIS is especially sensitive to the radial magnetic field at altitudes where the electron density in the ionosphere peaks (i.e. 100-200 km). Consequently, MARSIS is potentially capable of providing measurements for the radial component of the magnetic field at altitudes between 100 to 200 km that are normally out of reach for orbital magnetometers (with the exception of the aero-braking phase). Such low-altitude measurements would be complementary to already existing measurements at 400 km by MAG-ER on Mars Global Surveyor. This paper will explain the sensitivity of MARSIS as a magnetometer and the method envisioned to measure the radial magnetic field component. MARSIS (Picardi et al.), the first major planetary radar sounder, is the result of an international collaboration between NASA, the Italian Space Agency (ASI), and European Space Agency (ESA), and will arrive at Mars in early 2004 for a two-year mission. MARSIS has a frequency range between 0.1-5.5 MHz and is designed to penetrate the subsurface to a depth of a few kilometers. MARSIS primary objective is to map and characterize the subsurface geological structure of Mars, and search for subsurface liquid water reservoirs. The secondary objective of MARSIS is to study the ionosphere of Mars providing the most extensive amount of data on Martian ionosphere to date. In addition to MARSIS, a second radar sounder named SHARAD (SHallow RADar) with operation frequency of 15-25 MHz is under development. SHARAD is an Italian instrument (Seu et. al) that will fly on NASA s Mars Reconnaissance orbiter in 2005. SHARAD can also provide magnetic measurements, however, it is not expected to be as sensitive as MARSIS to magnetic field variations.

A Safaeinili↗

Design and numerical simulations of a high power 0.15 THz oscillator

An overmoded rectangularly corrugated relativistic surface wave oscillator is designed and theoretically analyzed to produce the high power terahertz radiation with a TM{sub 01} mode. The design is fully verified and optimized by 2.5D particle-in-cell simulations. A high power terahertz wave is obtained with the output power of 285 MW at the frequency of 0.148 THz with conversion efficiency 20% when beam voltage is about 400 kV, current 3.8 kA, and the magnetic field 6 T.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of 95 GHz gyrotron based on continuous operation copper solenoid with water cooling

The design work for 2nd harmonic 95 GHz, 50 kW gyrotron based on continuous operation copper solenoid is presented. Thermionic magnetron injection gun specifications were calculated according to the linear trade off equation, and simulated with CST program. Numerical code is used for cavity design using the non-uniform string equation as well as particle motion in the “cold” cavity field. The mode TE02 with low Ohmic losses in the cavity walls was chosen as the operating mode. The Solenoid is designed to induce magnetic field of 1.8 T over a length of 40 mm in the interaction region with homogeneity of ±0.34%. The solenoid has six concentric cylindrical segments (and two correction segments) of copper foil windings separated by water channels for cooling. The predicted temperature in continuous operation is below 93 °C. The parameters of the design together with simulation results of the electromagnetic cavity field, magnetic field, electron trajectories, and thermal analyses are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new large radius imaging plate camera for high-resolution and high-throughput synchrotron x-ray powder diffraction by multiexposure method

A new large radius imaging plate diffraction camera for high-resolution and high-throughput synchrotron x-ray powder diffraction by means of multiple exposures has been developed for an insertion device beamline of SPring-8, Japan. The new imaging plate camera consists of a large radius cylindrical shape imaging plate cassette that is 400 mm in length and 954.9 mm in cylinder radius. The cassette is designed to be mounted on the 2{theta} arm of the diffractometer of BL15XU in SPring-8. One imaging plate covers 24 deg. and several times of exposure changing the 2{theta}-setting angle is necessary to obtain whole powder diffraction data up to a high angle region. One pixel of the imaging plate corresponds to 0.003 deg. in 2{theta} when the readout pixel size is 50 {mu}m squares. Separately collected data are translated to 2{theta}-intensity format and are connected by comparing the peak and background intensity included in the overlapped area. The exposure time is less than 120 s for most samples and the readout time is about 3 min; thus, the total measurement time for one powder diffraction pattern is less than 20 min. The measurement time is the same order as the continuous 2{theta}-scanning method of the third generation synchrotron powder diffractometer. The angular resolution of the new imaging plate camera was evaluated by comparing the full width at half maximum of the 111 reflection of NBS-Si. The observed angular resolution is not so high as a powder diffractometer with a Si or a Ge analyzer monochromator in the third generation synchrotron facility but higher than a powder diffractometer with a Ge analyzer monochromator at a bending magnet beamline of the second generation synchrotron. The Rietveld analysis of NBS-CeO{sub 2} was successfully carried out with the data taken by the new imaging plate camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ACCELERATION OF GALACTIC COSMIC RAYS IN THE INTERSTELLAR MEDIUM

Challenges have arisen to diffusive shock acceleration as the primary means to accelerate galactic cosmic rays (GCRs) in the interstellar medium. Diffusive shock acceleration is also under challenge in the heliosphere, where at least the simple application of diffusive shock acceleration cannot account for observations. In the heliosphere, a new acceleration mechanism has been invented-a pump mechanism, driven by ambient turbulence, in which particles are pumped up in energy out of a low-energy core particle population through a series of adiabatic compressions and expansions-that can account for observations not only at shocks but in quiet conditions in the solar wind and throughout the heliosheath. In this paper, the pump mechanism is applied to the acceleration of GCRs in the interstellar medium. With relatively straightforward assumptions about the magnetic field in the interstellar medium, and how GCRs propagate in this field, the pump mechanism yields (1) the overall shape of the GCR spectrum, a power law in particle kinetic energy, with a break at the so-called knee in the GCR spectrum to a slightly steeper power-law spectrum. (2) The rigidity dependence of the H/He ratio observed from the PAMELA satellite instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

Waveguide detuning caused by transverse magnetic fields on a simulated in-line 6 MV linac

Purpose: Due to the close proximity of the linear accelerator (linac) to the magnetic resonance (MR) imager in linac-MR systems, it will be subjected to magnet fringe fields larger than the Earth's magnetic field of 5x10{sup -5} T. Even with passive or active shielding designed to reduce these fields, some magnitude of the magnetic field is still expected to intersect the linac, causing electron deflection and beam loss. This beam loss, resulting from magnetic fields that cannot be eliminated with shielding, can cause a detuning of the waveguide due to excessive heating. The detuning, if significant, could lead to an even further decrease in output above what would be expected strictly from electron deflections caused by an external magnetic field. Thus an investigation of detuning was performed through various simulations. Methods: According to the Lorentz force, the electrons will be deflected away from their straight course to the target, depositing energy as they impact the linac copper waveguide. The deposited energy would lead to a heating and deformation of the copper structure resulting in resonant frequency changes. PARMELA was used to determine the mean energy and fraction of total beam lost in each linac cavity. The energy deposited into the copper waveguide from the beam losses caused by transverse magnetic fields was calculated using the Monte Carlo program DOSRZnrc. From the total energy deposited, the rise in temperature and ultimately the deformation of the structure was estimated. The deformed structure was modeled using the finite element method program COMSOL MULTIPHYSICS to determine the change in cavity resonant frequency. Results: The largest changes in resonant frequency were found in the first two accelerating cavities for each field strength investigated. This was caused by a high electron fluence impacting the waveguide inner structures coupled with their low kinetic energies. At each field strength investigated, the total change in accelerator frequency was less than a manufacturing tolerance of 10 kHz and is thus not expected to have a noticeable effect on accelerator performance. Conclusions: The amount of beam loss caused by magnetic fringe fields for a linac in a linac-MR system depends on the effectiveness of its magnetic shielding. Despite the best efforts to shield the linac from the magnetic fringe fields, some persistent magnetic field is expected which would result in electron beam loss. This investigation showed that the detuning of the waveguide caused by additional electron beam loss in persistent magnetic fields is not a concern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two way coupling RAM-SCB to the space weather modeling framework

The Ring current Atmosphere interaction Model with Self-Consistently calculated 3D Magnetic field (RAM-SCB) has been used to successfully study inner magnetosphere dynamics during different solar wind and magnetosphere conditions. Recently, one way coupling of RAM-SCB with the Space Weather Modeling Framework (SWMF) has been achieved to replace all data or empirical inputs with those obtained through first-principles-based codes: magnetic field and plasma flux outer boundary conditions are provided by the Block Adaptive Tree Solar wind Roe-type Upwind Scheme (BATS-R-US) MHO code, convection electric field is provided by the Ridley Ionosphere Model (RIM), and ion composition is provided by the Polar Wind Outflow Model (PWOM) combined with a multi-species MHO approach. These advances, though creating a powerful inner magnetosphere virtual laboratory, neglect the important mechanisms through which the ring current feeds back into the whole system, primarily the stretching of the magnetic field lines and shielding of the convection electric field through strong region two Field Aligned Currents (FACs). In turn, changing the magnetosphere in this way changes the evolution of the ring current. To address this shortcoming, the coupling has been expanded to include feedback from RAM-SCB to the other coupled codes: region two FACs are returned to the RIM while total plasma pressure is used to nudge the MHO solution towards the RAMSCB values. The impacts of the two way coupling are evaluated on three levels: the global magnetospheric level, focusing on the impact on the ionosphere and the shape of the magnetosphere, the regional level, examining the impact on the development of the ring current in terms of energy density, anisotropy, and plasma distribution, and the local level to compare the new results to in-situ measurements of magnetic and electric field and plasma. The results will also be compared to past simulations using the one way coupling and no coupling whatsoever. This work is the first to fully couple an anisotropic kinetic ring current code with a selfconsistently calculated magnetic field to a set of global models.

47 OTHER INSTRUMENTATION↗

THE ACOUSTIC CUTOFF FREQUENCY OF THE SUN AND THE SOLAR MAGNETIC ACTIVITY CYCLE

The acoustic cutoff frequency-the highest frequency for acoustic solar eigenmodes-is an important parameter of the solar atmosphere as it determines the upper boundary of the p-mode resonant cavities. At frequencies beyond this value, acoustic disturbances are no longer trapped but are traveling waves. Interference among them gives rise to higher-frequency peaks-the pseudomodes-in the solar acoustic spectrum. The pseudomodes are shifted slightly in frequency with respect to p-modes, making possible the use of pseudomodes to determine the acoustic cutoff frequency. Using data from the GOLF and VIRGO instruments on board the Solar and Heliospheric Observatory spacecraft, we calculate the acoustic cutoff frequency using the coherence function between both the velocity and intensity sets of data. By using data gathered by these instruments during the entire lifetime of the mission (1996 until the present), a variation in the acoustic cutoff frequency with the solar magnetic activity cycle is found.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of secondary electrons suppression on emittance measurement of an intense, low-energy beam

Transversal emittance measurements of intense low-energy beams involve use of collimators. As most of the beam is stopped by a collimator, a question arises whether the special conditions in the vicinity of the collimator influence emittance measurement. In particular, the secondary electrons emitted from the slit surface may affect the measurement of the beam phase distribution. We have observed significant modification in the measured phase space distribution of a 5–6 mA DC proton beam at the Soreq Applied Research Accelerator Facility low-energy transport after application of a weak magnetic field in the plane of the slit collimator. The periphery region of the phase distribution was mostly affected. The overall effect on the emittance value was as large as 20%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗