Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

National Transonic Facility model and model support vibration problems

Vibrations of models and model support system were encountered during testing in the National Transonic Facility. Model support system yaw plane vibrations have resulted in model strain gage balance design load limits being reached. These high levels of vibrations resulted in limited aerodynamic testing for several wind tunnel models. The yaw vibration problem was the subject of an intensive experimental and analytical investigation which identified the primary source of the yaw excitation and resulted in attenuation of the yaw oscillations to acceptable levels. This paper presents the principal results of analyses and experimental investigation of the yaw plane vibration problems. Also, an overview of plans for development and installation of a permanent model system dynamic and aeroelastic response measurement and monitoring system for the National Transonic Facility is presented.

Young, Clarence P., Jr.↗

Base Flow Model Validation

A method was developed of obtaining propulsive base flow data in both hot and cold jet environments, at Mach numbers and altitude of relevance to NASA launcher designs. The base flow data was used to perform computational fluid dynamics (CFD) turbulence model assessments of base flow predictive capabilities in order to provide increased confidence in base thermal and pressure load predictions obtained from computational modeling efforts. Predictive CFD analyses were used in the design of the experiments, available propulsive models were used to reduce program costs and increase success, and a wind tunnel facility was used. The data obtained allowed assessment of CFD/turbulence models in a complex flow environment, working within a building-block procedure to validation, where cold, non-reacting test data was first used for validation, followed by more complex reacting base flow validation.

Sinha, Neeraj↗

Achieving an 80% carbon-free electricity system in China by 2035

Dramatic reductions in solar, wind, and battery storage costs create new opportunities to reduce emissions and costs in China’s electricity sector, beyond current policy goals. This study examines the cost, reliability, emissions, public health, and employment implications of increasing the share of non-fossil fuel (“carbon free”) electricity generation in China to 80% by 2035. The analysis uses state-of-the-art modeling with high resolution load, wind, and solar inputs. The study finds that achieving an 80% carbon free electricity system in China by 2035 could reduce wholesale electricity costs, relative to a current policy baseline, while maintaining high levels of reliability, reducing deaths from air pollution, and increasing employment. In our 80% scenario, wind and solar generation capacity reach 3 TW and battery storage capacity reaches 0.4 TW by 2035, implying a rapid scale up in these resources that will require changes in policy targets, markets and regulation, and land use policies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Calibration and Data Analysis Recommendations for Three-Component Moment Balances

Fundamental characteristics of design, calibration, and application of three-component moment balances are investigated in great detail. These balances are typically used to determine loads on control surfaces, canards, or other parts that are attached to a wind tunnel model. First, three different descriptions of the load state of a moment balance are reviewed. Then, load transformations between different load formats and the combined load diagram for two of the three load components are discussed. An error analysis showed that it is critical to maximize the product of the distance between the bending moment gages and their sensitivities in order to minimize the overall error in the normal force prediction. In addition, it is important to apply a sufficient number of calibration loadings near the first bending moment gage. Then, unwanted near-linear dependencies between the two bending moment gage outputs can be avoided. The error in the bending moment prediction is also investigated that results from the elastic deformation of the metric part of the balance under load. Finally, the application of the Non-Iterative Method to three-component moment balance calibration data is described in order to obtain regression models that can be used to predict loads from measured outputs during a wind tunnel test.

Strain-Gage Balance↗

Scale effects in the response and failure of fiber reinforced composite laminates loaded in tension and in flexure

The feasibility of using scale model testing for predicting the full-scale behavior of flat composite coupons loaded in tension and beam-columns loaded in flexure is examined. Classical laws of similitude are applied to fabricate and test replica model specimens to identify scaling effects in the load response, strength, and mode of failure. Experiments were performed on graphite-epoxy composite specimens having different laminate stacking sequences and a range of scaled sizes. From the experiments it was deduced that the elastic response of scaled composite specimens was independent of size. However, a significant scale effect in strength was observed. In addition, a transition in failure mode was observed among scaled specimens of certain laminate stacking sequences. A Weibull statistical model and a fracture mechanics based model were applied to predict the strength scale effect since standard failure criteria cannot account for the influence of absolute specimen size on strength.

Jackson, Karen E.↗

Wind turbine response in waked inflow: A modelling benchmark against full-scale measurements

Predicting the power and loads of wind turbines in waked inflow conditions still presents a major modelling challenge. It requires the accurate modelling of the atmospheric flow conditions, wakes of upstream turbines and the response of the turbine of interest. Rigorous validations of model frameworks against measurements of utility-scale wind turbines in such scenarios remain limited to date. In this study, six models of different fidelity are compared against measurements from the DanAero experiment. The two benchmark cases feature a full-wake and partial-wake scenario, respectively. The simulations are compared against local pressure forces and inflow velocities measured on several blade sections of the downstream turbine, as well as met mast measurements and standard SCADA data. Regardless of the model fidelity, reasonable agreements are found in terms of the wake characteristics and turbine response. For instance, the azimuth variation of the mean aerodynamic forces acting on the blade was captured with a mean relative error of 15-20%. Additionally, while various model-specific deficiencies could be identified, the study highlights the need for further full-scale measurement campaigns with even more extensive instrumentation. Furthermore, it is concluded that validations should not be limited to integrated and/or time-averaged quantities that conceal characteristic spatial or temporal variations.

17 WIND ENERGY↗

Equivalent Plate Analysis of Aircraft Wing with Discrete Source Damage

An equivalent plate procedure is developed to provide a computationally efficient means of matching the stiffness and frequencies of flight vehicle wing structures for prescribed loading conditions. First, the equivalent plate is used to match the stiffness of a stiffened panel without damage and the stiffness of a stiffened panel with damage. For both stiffened panels, the equivalent plate models reproduce the deformation of a corresponding detailed model exactly for the given loading conditions. Once the stiffness was matched, the equivalent plate models were then used to predict the frequencies of the panels. Two analytical procedures using the lumped-mass matrix were used to match the first five frequencies of the corresponding detailed model. In both the procedures, the lumped-mass matrix for the equivalent plate is constructed by multiplying the diagonal terms of the consistent-mass matrix by a proportionality constant. In the first procedure, the proportionality constant is selected such that the total mass of the equivalent plate is equal to that of the detailed model. In the second method, the proportionality constant is selected to minimize the sum of the squares of the errors in a set of pre-selected frequencies between the equivalent plate model and the detailed model. The equivalent plate models reproduced the fundamental first frequency accurately in both the methods. It is observed that changing only the mass distribution in the equivalent plate model did not provide enough flexibility to match all of the frequencies.

Krishnamurthy, T.↗

Patterns of deformation and volcanic flows associated with lithospheric loading by large volcanoes on Venus

Magellan radar imaging and topography data are now available for a number of volcanoes on Venus greater than 100 km in radius. These data can be examined to reveal evidence of the flexural response of the lithosphere to the volcanic load. On Venus, erosion and sediment deposition are negligible, so tectonic evidence of deformation around large volcanoes should be evident except where buried by very young flows. Radar images reveal that most tectonic features and flow units on the flanks of these volcanoes have predominantly radial orientations. However, both Tepev Mons in Bell Regio and Sapas Mons in Atla Regio exhibit circumferential graben on their flanks. In addition, images reveal several flow units with an annular character around the north and west flanks of Tepev Mons. This pattern most likely results from ponding of flows in an annular flexural moat. Maat Mons in Atla Regio and Sif Mons in Eistla Regio are examples of volcanoes that lack circumferential graben and annular flows; discernible flow units and fractures on these constructs appear to be predominantly radial. Altimetry data can also provide evidence of flexural response. Tepev Mons is partially encircled by depressions that may be sections of a flexural moat that has not been completely filled. The locations of these depressions generally coincide with the annular flows described above. There is weaker evidence for such depressions around Maat Mons as well. The lack of circumferential tectonic features around most volcanoes on Venus might be explained by gradual moat filling and coverage by radial flows. The depressions around Tepev (and possible Maat) may indicate that this process is currently continuing. We use analytic models of plate flexure in an axisymmetric geometry to constrain the elastic plate thickness supporting Tepev Mons. If we consider the outer radius of the ponded flows to be the edge of a moat, we find that models with elastic plate thickness of 10-20 km fit best. Finite element models of a volcanic load detached from the underlying lithosphere predict overthrusting and radial normal faulting at the volcano's edge. Such a mechanism for the formation of radial rift zones on Venus volcanoes would make such features analogous to structures on the flanks of volcanoes on Earth.

Mcgovern, Patrick J.↗

Assessing Dynamic Behaviors in Converter- Dominated Power Systems via RMS and EMT Simulations: A Study of Hawaii’s NELHA Microgrid

The transition from conventional power systems to converter-based microgrids has significantly advanced sustainability, clean energy integration, and operational reliability. However, this paradigm shift introduces operational challenges due to the intermittent nature of renewable energy sources and the non-linear characteristics of power electronic loads, inducing voltage fluctuations and harmonic distortions that complicate voltage and frequency regulation. Accurate dynamic modeling is hypothesized to be critical for capturing such effects, enabling reliable simulation and control strategy development. This study introduces an innovative dynamic modeling framework for a real-world converter-based microgrid, utilizing both root mean square (RMS) and electromagnetic transient (EMT) simulation methods. The microgrid was modeled in DIgSILENT PowerFactory, with simulations calibrated against high-resolution field measurements from SEL-735 power quality meters. Results show that RMS simulations effectively characterize steady-state dynamics, while EMT simulations are essential for capturing high-frequency transients and non-linear effects from photovoltaic inverters and variable frequency drives (VFDs). This complementary approach provides a comprehensive understanding of microgrid behavior, providing critical insights for improving simulation accuracy, advancing protection schemes, and improving resilience in future low-inertia power networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of various parameters of different porous transport layers in proton exchange membrane water electrolysis

Porous transport layers (PTLs) play an important role in proton exchange membrane water electrolysis (PEMWE) cells. The PTL facilitates water and gas transport, as well as thermal and electrical conduction, and is required to sustain good contact with adjacent components. It is expected that using PTLs with variations in material properties such as structure, composition, thickness and wettability results in performance changes of the PEMWE. Here, a general mathematical PEMWE model is developed that separates and analyzes the contributions of ohmic, activation, diffusion and Nernst potentials. For model validation, three inherently different anode PTL structures (carbon paper, sintered titanium particles, and titanium felt) are operated over a range of conditions. Additionally, the effects of PTL wettability were used to verify the model using Polytetrafluoroethylene (PTFE) treated Toray papers with PTFE loading ranging from 0% to 20%. The modeling results of both PTFE treated and untreated materials show good agreement with the experimental data. Mass transport or diffusion loss is the primary reason for performance differences between PTFE treated and untreated PTLs. Sintered titanium PTLs with thicknesses above 1 mm suffer from up to 33% increased ohmic losses without indicating any obvious changes in activation and diffusion losses when compared to untreated PTLs. The losses of the cell increase when using PTFE treated Toray paper. Individual contributions are quantified and assigned to increased ohmic, activation, and diffusion losses. In conclusion, the proposed model offers insights into the overpotential contributions of a PEMWE. It is a useful tool for predicting performance of various PTL materials and can be applied for PTL development and optimization efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of bearing deadbands on bearing loads and rotor stability

The Jeffcott model of a turbopump which was modified by adding deadband (clearance) effects along with fluid seal forces are currently understood. Equations of motion for the model were written in polar coordinates, and a constant side force was added to the model to account for the likely misalignment between bearings and seals. The force models and system equations of motion are described as well as limit cycle, and stability analyses. Studies of systems with rotor imbalance and with or without side effects were studied for three types of motion. Results show that: (1) deadband does not affect stability-in-the-large; (2) stability-in-the small is enhanced by deadband and side force; (3) bearings loads are highest for motion with synchronous or nonsynchronous periodic enclosing origin; (4) side force acting in concert with deadband effects may either increase or decrease bearing loads; and (5) bearing loads in a stable pump are determined primarily by rotor imbalance and side forces.

Glaese, J. R.↗

Dual-band reactively loaded microstrip antenna

A previously derived theory is applied to a microstrip antenna with a reactive load to produce a dual-band radiator. A model consisting of a rectangular patch radiator loaded with a variable length short-circuited coaxial stub was investigated experimentally. Comparisons of theoretical predictions and experimental data are made for the impedance and resonant frequencies as a function of the position of the load, the length of the stub, and the characteristic impedance of the stub.

Richards, W. F.↗

3D inelastic analysis methods for hot section components

The objective is to develop analytical tools capable of economically evaluating the cyclic time dependent plasticity which occurs in hot section engine components in areas of strain concentration resulting from the combination of both mechanical and thermal stresses. Three models were developed. A simple model performs time dependent inelastic analysis using the power law creep equation. The second model is the classical model of Professors Walter Haisler and David Allen of Texas A and M University. The third model is the unified model of Bodner, Partom, et al. All models were customized for linear variation of loads and temperatures with all material properties and constitutive models being temperature dependent.

Dame, L. T.↗

Development and Verification of an Improved Wake-Added Turbulence Model in FAST.Farm

We introduce a generalized wake-added turbulence (WAT) model in the multiphysics, multiturbine simulation tool FAST.Farm. The WAT model introduces additional small-scale turbulence that represents the breakdown of vortical structures and shear layers in the wake. The article describes the development, implementation, calibration, and verification of the model. The novelties of the model include support for wake asymmetry, buildup of WAT across the wind farm, and secondary effects of wake-induced turbulence (e.g., wake meandering) driven by smaller-scale turbulence structures that arise from wake breakdown. Large-eddy simulations were run to support the calibration of the WAT parameters and verification of the model. Previous studies hypothesized that the lack of WAT modeling was the source of underprediction of fatigue loads, in particular for cases at low turbulence intensities and/or stable atmospheric boundary layers. This study confirms that the newly implemented WAT model enhances the loads predictions in these cases.

17 WIND ENERGY↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transformative Efficiency and Automation in Modular Homes (TEAMH)

This report documents the Transformative Efficiency and Automation in Modular Homes (TEAMH) project, which evaluates the integration of advanced building envelope technologies and automation-assisted modular construction to improve residential energy performance and construction efficiency. The study investigates high-performance insulation systems, including vacuum insulation panels (VIPs), combined with light gauge steel (LGS) modular construction and factory automation. Laboratory testing, whole-building energy modeling across multiple climate zones, and factory demonstrations were conducted to assess thermal performance, energy savings, and production efficiency. Results indicate that upgraded envelope assemblies can achieve up to ~50% heating and ~34% cooling energy savings relative to IECC 2018 code-compliant homes, while automation-assisted construction can reduce wall assembly time by 24%–46% compared to conventional wood framing. The findings demonstrate the potential for scalable, high-performance modular homes that deliver significant energy savings with competitive projected costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Linear dynamic analysis of the Space Station Freedom thermal/environmental control system

A methodology for dynamic analysis of the Space Station Freedom thermal/environmental control system is described which uses linear system analysis techniques to determine the ability of the system to accommodate thermal load transients. A nonlinear integrated model of the system as it exists at Stage 6, Man Tended Capability (MTC), is described which encompasses the cabin air cooling system, avionics air cooling system, internal and external thermal control systems. The nonlinear model is linearized at an assumed design operating point, and the linear model is evaluated by comparison with the nonlinear model. Transfer functions are derived to determine the response of the heat rejection system to time-varying thermal loads applied at various points in the heat acquisition system. The frequency response calculated from the transfer functions is used to determine allowable operating envelopes of thermal load magnitude and frequency for each point of application of thermal load. The dynamic operating envelopes provide a quantitative indication of the degree and duration of peak loads which the thermal/environmental system is able to transport and reject.

Tandler, John↗

Vibratory Loads Data from a Wind-Tunnel Test of Structurally Tailored Model Helicopter Rotors

An experimental study was conducted in the Langley Transonic Dynamics Tunnel to investigate the use of a Bell Helicopter Textron (BHT) rotor structural tailoring concept, known as rotor nodalization, in conjunction with advanced blade aerodynamics as well as to evaluate rotor blade aerodynamic design methodologies. A 1/5-size, four-bladed bearingless hub, three sets of Mach-scaled model rotor blades were tested in forward flight from transition up to an advance ratio of 0.35. The data presented pertain only to the evaluation of the structural tailoring concept and consist of fixed-system and rotating system vibratory loads. These data will be useful for evaluating the effects of tailoring blade structural properties on fixed-system vibratory loads, as well as validating analyses used in the design of advanced rotor systems.

Yeager, William T., Jr.↗