A determination of the radio-planetary frame tie and the DSN tracking station locations

The orientation of the reference frame of radio source catalogs relative to that of planetary ephemerides is uncertain by 30 mas (150 nrad). At this level of uncertainty this orientation offset, or 'frame tie', can be a major systematic error source for interplanetary spacecraft orbit determination. This work presents a method of determining the radio-planetary frame tie from a comparison of Very Long Baseline Interferometry (VLBI) and Lunar Laser Ranging (LLR) station coordinate and earth orientation parameter estimates. Preliminary results are presented which indicate that accuracies of 5 mas or better may be achieved with this method. An important by-product of this method of frame tie determination is a set of Deep Space Network (DSN) station locations with 10 cm per component accuracy. This station set is in a geocentric coordinate system with known orientation relative to the radio and planetary frames.

Finger, Mark H.↗

The Dissociation Energies of He2, HeH, and ArH; A Bond Function Study

The bond energies and bond lengths are determined for He2, HeH, and ArH at the CCSD(T) level using both atom-centered basis sets and those that include bond functions. The addition of bond functions dramatically improves the rate of convergence of the results with respect to the size of the atom-centered basis set; with bond functions, triple zeta atom-centered basis set, outperform quintuple zeta basis sets without bond functions. The addition of bond functions also reduces the number of diffuse functions that must be added to the atom-centered sets. Employing bond functions appear to offer a very cost effective method of computing the interaction between weakly bound systems, especially for He.

Bauschlicher, Charles W., Jr.↗

NASA Langley's Approach to the Sandia's Structural Dynamics Challenge Problem

The objective of this challenge is to develop a data-based probabilistic model of uncertainty to predict the behavior of subsystems (payloads) by themselves and while coupled to a primary (target) system. Although this type of analysis is routinely performed and representative of issues faced in real-world system design and integration, there are still several key technical challenges that must be addressed when analyzing uncertain interconnected systems. For example, one key technical challenge is related to the fact that there is limited data on target configurations. Moreover, it is typical to have multiple data sets from experiments conducted at the subsystem level, but often samples sizes are not sufficient to compute high confidence statistics. In this challenge problem additional constraints are placed as ground rules for the participants. One such rule is that mathematical models of the subsystem are limited to linear approximations of the nonlinear physics of the problem at hand. Also, participants are constrained to use these models and the multiple data sets to make predictions about the target system response under completely different input conditions. Our approach involved initially the screening of several different methods. Three of the ones considered are presented herein. The first one is based on the transformation of the modal data to an orthogonal space where the mean and covariance of the data are matched by the model. The other two approaches worked solutions in physical space where the uncertain parameter set is made of masses, stiffnesses and damping coefficients; one matches confidence intervals of low order moments of the statistics via optimization while the second one uses a Kernel density estimation approach. The paper will touch on all the approaches, lessons learned, validation 1 metrics and their comparison, data quantity restriction, and assumptions/limitations of each approach. Keywords: Probabilistic modeling, model validation, uncertainty quantification, kernel density

Horta, Lucas G.↗

CLARREO Cornerstone of the Earth Observing System: Measuring Decadal Change Through Accurate Emitted Infrared and Reflected Solar Spectra and Radio Occultation

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) is one of four Tier 1 missions recommended by the recent NRC Decadal Survey report on Earth Science and Applications from Space (NRC, 2007). The CLARREO mission addresses the need to provide accurate, broadly acknowledged climate records that are used to enable validated long-term climate projections that become the foundation for informed decisions on mitigation and adaptation policies that address the effects of climate change on society. The CLARREO mission accomplishes this critical objective through rigorous SI traceable decadal change observations that are sensitive to many of the key uncertainties in climate radiative forcings, responses, and feedbacks that in turn drive uncertainty in current climate model projections. These same uncertainties also lead to uncertainty in attribution of climate change to anthropogenic forcing. For the first time CLARREO will make highly accurate, global, SI-traceable decadal change observations sensitive to the most critical, but least understood, climate forcings, responses, and feedbacks. The CLARREO breakthrough is to achieve the required levels of accuracy and traceability to SI standards for a set of observations sensitive to a wide range of key decadal change variables. The required accuracy levels are determined so that climate trend signals can be detected against a background of naturally occurring variability. Climate system natural variability therefore determines what level of accuracy is overkill, and what level is critical to obtain. In this sense, the CLARREO mission requirements are considered optimal from a science value perspective. The accuracy for decadal change traceability to SI standards includes uncertainties associated with instrument calibration, satellite orbit sampling, and analysis methods. Unlike most space missions, the CLARREO requirements are driven not by the instantaneous accuracy of the measurements, but by accuracy in the large time/space scale averages that are key to understanding decadal changes.

Sandford, Stephen P.↗

Fuzzy set methods for object recognition in space applications

Progress on the following tasks is reported: (1) fuzzy set-based decision making methodologies; (2) feature calculation; (3) clustering for curve and surface fitting; and (4) acquisition of images. The general structure for networks based on fuzzy set connectives which are being used for information fusion and decision making in space applications is described. The structure and training techniques for such networks consisting of generalized means and gamma-operators are described. The use of other hybrid operators in multicriteria decision making is currently being examined. Numerous classical features on image regions such as gray level statistics, edge and curve primitives, texture measures from cooccurrance matrix, and size and shape parameters were implemented. Several fractal geometric features which may have a considerable impact on characterizing cluttered background, such as clouds, dense star patterns, or some planetary surfaces, were used. A new approach to a fuzzy C-shell algorithm is addressed. NASA personnel are in the process of acquiring suitable simulation data and hopefully videotaped actual shuttle imagery. Photographs have been digitized to use in the algorithms. Also, a model of the shuttle was assembled and a mechanism to orient this model in 3-D to digitize for experiments on pose estimation is being constructed.

Keller, James M.↗

Mitigation of the Brighter-fatter Effect in the LSST Camera

Abstract Thick, fully depleted charge-coupled devices are known to exhibit nonlinear behavior at high signal levels due to the dynamic behavior of charges collecting in the potential wells of pixels, called the brighter-fatter effect (BFE). The effect results in distorted images of bright calibration stars, creating a flux-dependent point-spread function that if left unmitigated, could make up a large fraction of the error budget in Stage IV weak-lensing (WL) surveys such as the Legacy Survey of Space and Time (LSST). In this paper, we analyze image measurements of flat fields and artificial stars taken at different illumination levels with the LSST Camera (LSSTCam) at SLAC National Accelerator Laboratory in order to quantify this effect in the LSSTCam before and after a previously introduced correction technique. We observe that the BFE evolves anisotropically as a function of flux due to higher-order BFEs, which violates the fundamental assumption of this correction method. We then introduce a new method based on a physically motivated model to account for these higher-order terms in the correction, and then we test the modified correction on both data sets. We find that the new method corrects the effect in flat fields better than it corrects the effect in artificial stars, which we suggest is the result of sub-pixel physics not included in this correction model. We use these results to define a new metric for the full-well capacity of our sensors and advise image processing strategies to further limit the impact of the effect on LSST WL science pathways.

47 OTHER INSTRUMENTATION↗

Interplanetary proton fluence model - JPL 1991

We describe an updated predictive engineering model for the interplanetary fluence of protons with energies respectively greater than 1, 4, 10, 30, and 60 MeV. This has been the first opportunity to derive a model from a data set that has been collected in space over a long enough period of time to produce a valid sample of solar proton events. The model provides a quantitative basis for estimating the exposures to solar protons of spacecraft during missions of varying length and of surfaces and atmospheres of solar system objects. The data sets contain several major proton events comparable to the 1972 event. For the cases of the over 10 and over 30 MeV particles, the fluences are somewhat lower than in our earlier model No over 1, over 4, and over 60 MeV proton fluence models have been published in the literature previously. We present our results in a convenient graphical form which may be used to calculate the 1 AU fluence expected at a given confidence level as a function of the length of the exposure. A method of extending this estimate to other heliocentric distances is described.

Feynman, J.↗

Opening Loads Analyses for Various Disk-Gap-Band Parachutes

Detailed opening loads data is presented for 18 tests of Disk-Gap-Band (DGB) parachutes of varying geometry with nominal diameters ranging from 43.2 to 50.1 ft. All of the test parachutes were deployed from a mortar. Six of these tests were conducted via drop testing with drop test vehicles weighing approximately 3,000 or 8,000 lb. Twelve tests were conducted in the National Full-Scale Aerodynamics Complex 80- by 120-foot wind tunnel at the NASA Ames Research Center. The purpose of these tests was to structurally qualify the parachute for the Mars Exploration Rover mission. A key requirement of all tests was that peak parachute load had to be reached at full inflation to more closely simulate the load profile encountered during operation at Mars. Peak loads measured during the tests were in the range from 12,889 to 30,027 lb. Of the two test methods, the wind tunnel tests yielded more accurate and repeatable data. Application of an apparent mass model to the opening loads data yielded insights into the nature of these loads. Although the apparent mass model could reconstruct specific tests with reasonable accuracy, the use of this model for predictive analyses was not accurate enough to set test conditions for either the drop or wind tunnel tests. A simpler empirical model was found to be suitable for predicting opening loads for the wind tunnel tests to a satisfactory level of accuracy. However, this simple empirical model is not applicable to the drop tests.

Cruz, J. R.↗

NASA Weather Support 2017

In the mid to late 1980's, as NASA was studying ways to improve weather forecasting capabilities to reduce excessive weather launch delays and to reduce excessive weather Launch Commit Criteria (LCC) waivers, the Challenger Accident occurred and the AC-67 Mishap occurred.[1] NASA and USAF weather personnel had advance knowledge of extremely high levels of weather hazards that ultimately caused or contributed to both of these accidents. In both cases, key knowledge of the risks posed by violations of weather LCC was not in the possession of final decision makers on the launch teams. In addition to convening the mishap boards for these two lost missions, NASA convened expert meteorological boards focusing on weather support. These meteorological boards recommended the development of a dedicated organization with the highest levels of weather expertise and influence to support all of American spaceflight. NASA immediately established the Weather Support Office (WSO) in the Office of Space Flight (OSF), and in coordination with the United Stated Air Force (USAF), initiated an overhaul of the organization and an improvement in technology used for weather support as recommended. Soon after, the USAF established a senior civilian Launch Weather Officer (LWO) position to provide meteorological support and continuity of weather expertise and knowledge over time. The Applied Meteorology Unit (AMU) was established by NASA, USAF, and the National Weather Service to support initiatives to place new tools and methods into an operational status. At the end of the Shuttle Program, after several weather office reorganizations, the WSO function had been assigned to a weather branch at Kennedy Space Center (KSC). This branch was dismantled in steps due to further reorganization, loss of key personnel, and loss of budget line authority. NASA is facing the loss of sufficient expertise and leadership required to provide current levels of weather support. The recommendation proposed herein is to re-establish the WSO under a high level office, with funding set at about the same levels as today, with a revitalized charter and focus to allow for the WSO to operate as originally intended.

lessons learned↗

Development of Processing Technology for Radioactively Contaminated Water at Chernobyl Nuclear Power Plant - 19656

During the operation of the Chernobyl Nuclear Power Plant, distillation by evaporation was the main method for processing radioactively contaminated water. When the plant was decommissioned, the evaporation facility was mothballed and floor drain treatment was suspended in 2016. At present, the existing tanks with the capacity of 26,000 m{sup 3} are more than 60% full with radioactively contaminated floor drains, which requires alternative processing methods. The current process flow for radioactive waste management at State Specialized Enterprise 'Chernobyl NPP' includes processing of accumulated liquid radioactive wastes at a liquid radioactive wastes processing plant. Under the processing technology, liquid radioactive waste is immobilized at the plant by cementation and the resulting solid radioactive waste is then buried in a near-surface storage. Key factors for the selection of alternative radioactively contaminated water processing methods are the possibility to clear the processed water (no control monitoring), which requires the same degree of processing as for drinking water, and minimization of radioactive waste generation due to the lack of free space for solid waste disposal in the near-surface storage. Floor drains that require processing contain radionuclides such as {sup 137}Cs, {sup 90}Sr, {sup 60}Co and {sup 40}K. The current level of the total beta and gamma activity is about 4*105 Bq/kg. The following criteria are set for the Chernobyl NPP site for water to be disposed to the sewerage system: - Max. 37 Bq/kg for the total beta and gamma containing radionuclide activity; - Max. 0.7 Bq/kg for the total alpha containing radionuclide activity. METOIL produces inorganic sorbents for removing radionuclides from liquids and develops sorbent-based technology for a variety of applications related to liquid radioactive waste processing. In 2017-2018, experts from the Chernobyl NPP and METOIL ran several joint laboratory tests to evaluate the efficiency of inorganic sorbents made by METOIL for processing floor drains at the Chernobyl NPP. The test procedure included treatment of radioactively contaminated water in a two-stage sorption process: static sorption (sorbents are mixed in a liquid) and dynamic sorption (the liquid is filtered through a sorbent column). NIKET and MODIKS sorbents were provided for the tests. The results of the test measurements showed that the total alpha containing radionuclide activity is less than 0.026 Bq/kg and the total beta and gamma containing radionuclide activity is 9.2 Bq/kg. The physical and chemical parameters after processing also met the water disposal criteria. High sorption capacity of the sorbents used for the tests allows processing hundreds of water volumes with just one sorbent volume. At present, preparations are underway for full-scale tests at a pilot plant with a capacity of minimum 10 m{sup 3}/day. At a later stage, spent sorbents may be immobilized by inclusion into the cement matrix, which will substantially reduce the amount of radioactive waste to be buried. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

New Levels of High Angular Resolution EBSD Performance via Inverse Compositional Gauss-Newton Digital Image Correlation

Conventional high angular resolution electron backscatter diffraction (HREBSD) uses cross-correlation to track features between diffraction patterns, which are then related to the relative elastic strain and misorientation between the diffracting volumes of material. This paper adapts inverse compositional Gauss Newton (ICGN) digital image correlation (DIC) to be compatible with HREBSD. ICGN works by efficiently tracking not just the shift in features, but also the change in their shape. Modeling a shape change as well as a shift results in greater accuracy. This method, ICGN HREBSD, is applied to a simulated data set, and its performance is compared to conventional cross-correlation HREBSD, and cross-correlation HREBSD with remapping. ICGN HREBSD is shown to have about half the strain error of the best cross-correlation method with a comparable computation time.

T. J. Ruggles↗

Consequences of Different Air-Sea Feedbacks on Ocean Using MITgcm and MERRA-2 Forcing: Implications for Coupled Data Assimilation Systems

Ocean surface flux estimates from atmospheric and oceanic reanalyses contain errors that compensate for inaccuracies in the respective atmosphere and ocean models used to generate these reanalyses. A conundrum for climate studies is the discrepancy between surface fluxes that minimize model-data differences for an atmosphere-only model vs surface fluxes that minimize model-data differences for an ocean model. As a first step towards a consistent coupled ocean-atmosphere data-assimilation (DA) system, we compare surface net heat flux from a state-of-the-art atmospheric reanalysis, the Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2), to net heat flux from a state-of-the-art ocean state estimate, the Estimating the Circulation and Climate of the Ocean Version 4 (ECCO-v4). The possible impacts of the MERRA-2 and ECCO-v4 air-sea net heat flux difference in a coupled DA system were assessed using a set of experiments designed to imitate different “flavors” of a coupled DA system in an ocean-only setup. This was done by forcing the ECCO-v4 underlying ocean model - the Massachusetts Institute of Technology general circulation model (MITgcm) - with different sets of MERRA-2 fields and utilizing different forcing methods. By doing so we were able to turn off different air-sea feedbacks which, in a coupled DA setup, are partially muted by the constraining observations. The set of experiments, therefore, represents a range of active feedbacks in different “flavors” of coupled data-assimilation systems. For the period 1992–2011, MERRA-2 net heat flux has a global mean difference of -4.9 Wm(exp -2) relative to ECCO-v4. When MERRA-2 surface fields are used to force MITgcm, imbalances in the energy and the hydrological cycles of MERRA-2, which are directly related to the fact that MERRA-2 was created without an interactive ocean, propagate to the ocean. The experiment in which MITgcm is forced with MERRA-2 fluxes (MERRA-2-flux experiment) results in a 2.5°C global mean Sea Surface Temperature (SST) cooling, a 1m reduction in global mean sea level, and other drastic changes in the large scale ocean circulation relative to those resulting when the MITgcm is forced with the optimized ECCO-v4 net heat flux (the ECCO-v4 experiment itself). When MITgcm is forced with MERRA-2 state variables (MERRA-2-state experiment), the SST is somewhat restored to the observed SST, but the errors are shifted to the water cycle, resulting in a global mean sea level increase of 2.7 m. To further explore the pros and cons of these two approaches, we introduce a new intermediate forcing method in which the ocean is forced with turbulent fluxes but has a long wave feedback. This method, unlike MERRA-2 state, preserves the MERRA-2 water and salinity cycles, and it reduces the SST error compared to the MERRA-2-flux experiment, but the SST is not as good as that in the MERRA-2-state experiment. Our results have implications for ocean-model forcing recipes and clearly reveal the undesirable consequences of limiting the feedbacks in either these types of experiments or in coupled DA.

Ehud Strobach↗

Assessment of task‐based performance from five clinical DBT systems using an anthropomorphic breast phantom

Purpose Digital breast tomosynthesis (DBT) is a limited‐angle tomographic breast imaging modality that can be used for breast cancer screening in conjunction with full‐field digital mammography (FFDM) or synthetic mammography (SM). Currently, there are five commercial DBT systems that have been approved by the U.S. FDA for breast cancer screening, all varying greatly in design and imaging protocol. Because the systems are different in technical specifications, there is a need for a quantitative approach for assessing them. In this study, the DBT systems are assessed using a novel methodology with an inkjet‐printed anthropomorphic phantom and four alternative forced choice (4AFC) study scheme. Method A breast phantom was fabricated using inkjet printing and parchment paper. The phantom contained 5‐mm spiculated masses fabricated with potassium iodide (KI)‐doped ink and microcalcifications (MCs) made with calcium hydroxyapatite. Images of the phantom were acquired on all five systems with DBT, FFDM, and SM modalities where available using beam settings under automatic exposure control. A 4AFC study was conducted to assess reader performance with each signal under each modality. Statistical analysis was performed on the data to determine proportion correct (PC), standard deviations, and levels of significance. Results For masses, overall detection was highest with DBT. The difference in PC was statistically significant between DBT and SM for most systems. A relationship was observed between increasing PC and greater gantry span. For MCs, performance was highest with DBT and FFDM compared to SM. The difference between PC of DBT and PC of SM was statistically significant for all manufacturers. Conclusions This methodology represents a novel approach for evaluating systems. This study is the first of its kind to use an inkjet‐printed anthropomorphic phantom with realistic signals to assess performance of clinical DBT imaging systems.

Ikejimba, Lynda C.↗

Component-wise reduced order model lattice-type structure design

Lattice-type structures can provide a combination of stiffness with light weight that is desirable in a variety of applications. Design optimization of these structures must rely on approximations of the governing physics to render solution of a mathematical model feasible. In this paper, we propose a topology optimization (TO) formulation that approximates the governing physics using component-wise reduced order modeling as introduced in Huynh et al. (2013); Eftang and Patera (2013), which can reduce solution time by multiple orders of magnitude over a full-order finite element model while providing a relative error in the solution of 1%. In addition, the offline training data set from such component-wise models is reusable, allowing its application to many design problems for only the cost of a single offline training phase, and the component-wise method is nearly embarrassingly parallel. We also show how the parameterization chosen in our optimization allows a simplification of the component-wise reduced order model (CWROM) not noted in previous literature, for further speedup of the optimization process. Furthermore, the sensitivity of the compliance with respect to the particular parameterization is derived solely at the component level. In numerical examples, we demonstrate a 1000x speedup over a full-order FEM model with relative error of 1% and show minimum compliance designs for two different cantilever beam examples, one smaller and one larger. Finally, error bounds for the displacement field, compliance, and compliance sensitivity of the CWROM are derived.

97 MATHEMATICS AND COMPUTING↗

High-Sensitivity C-Reactive Protein Complements Plasma Epstein-Barr Virus Deoxyribonucleic Acid Prognostication in Nasopharyngeal Carcinoma: A Large-Scale Retrospective and Prospective Cohort Study

Purpose: To evaluate the effects of combining the assessment of circulating high-sensitivity C-reactive protein (hs-CRP) with that of Epstein-Barr virus DNA (EBV DNA) in the pretherapy prognostication of nasopharyngeal carcinoma (NPC). Patients and Methods: Three independent cohorts of NPC patients (training set of n=3113, internal validation set of n=1556, and prospective validation set of n=1668) were studied. Determinants of disease-free survival, distant metastasis–free survival, and overall survival were assessed by multivariate analysis. Hazard ratios and survival probabilities of the patient groups, segregated by clinical stage (T1-2N0-1M0, T3-4N0-1M0, T1-2N2-3M0, and T3-4N2-3M0) and EBV DNA load (low or high) alone, and also according to hs-CRP level (low or high), were compared. Results: Elevated hs-CRP and EBV DNA levels were significantly correlated with poor disease-free survival, distant metastasis–free survival, and overall survival in both the training and validation sets. Associations were similar and remained significant after excluding patients with cardiovascular disease, diabetes, and chronic hepatitis B. Patients with advanced-stage disease were segregated by high EBV DNA levels and high hs-CRP level into a poorest-risk group, and participants with either high EBV DNA but low hs-CRP level or high hs-CRP but low EBV DNA values had poorer survival compared with the bottom values for both biomarkers. These findings demonstrate a significant improvement in the prognostic ability of conventional advanced NPC staging. Conclusion: Baseline plasma EBV DNA and serum hs-CRP levels were significantly correlated with survival in NPC patients. The combined interpretation of EBV DNA with hs-CRP levels led to refinement of the risks for the patient subsets, with improved risk discrimination in patients with advanced-stage disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online Adaptive Hyperthermia Treatment Planning During Locoregional Heating to Suppress Treatment-Limiting Hot Spots

Background: Adequate tumor temperatures during hyperthermia are essential for good clinical response, but excessive heating of normal tissue should be avoided. This makes locoregional heating using phased array systems technically challenging. Online application of hyperthermia treatment planning could help to improve the heating quality. The aim of this study was to evaluate the clinical benefit of online treatment planning during treatment of pelvic tumors heated with the AMC-8 locoregional hyperthermia system. Methods: For online adaptive hyperthermia treatment planning, a graphical user interface was developed. Electric fields were calculated in a preprocessing step using our in-house–developed finite-difference–based treatment planning system. This allows instant calculation of the temperature distribution for user-selected phase-amplitude settings during treatment and projection onto the patient's computed tomographic scan for online visualization. Online treatment planning was used for 14 treatment sessions in 8 patients to reduce the patients' reports of hot spots while maintaining the same level of tumor heating. The predicted decrease in hot spot temperature should be at least 0.5°C, and the tumor temperature should decrease less than 0.2°C. These predictions were compared with clinical data: patient feedback about the hot spot and temperature measurements in the tumor region. Results: In total, 17 hot spot reports occurred during the 14 sessions, and the alternative settings predicted the hot spot temperature to decrease by at least 0.5°C, which was confirmed by the disappearance of all 17 hot spot reports. At the same time, the average tumor temperature was predicted to change on average −0.01°C (range, −0.19°C to 0.34°C). The measured tumor temperature change was on average only −0.02°C (range, −0.26°C to 0.31°C). In only 2 cases the temperature decrease was slightly larger than 0.2°C, but at most it was 0.26°C. Conclusions: Online application of hyperthermia treatment planning is reliable and very useful to reduce hot spots without affecting tumor temperatures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linking international technical specifications for acoustic characterization of marine energy converter sounds with environmental compliance criteria

As new ocean energy technologies emerge and are deployed for testing and operations, sound emissions are a potential concern for environmental effects to marine life. Consistent acoustic measurement and data analysis methods can help promote comparisons of technologies and transferability between project sites. In 2022, acoustic emissions from a prototype scale wave energy converter (WEC) were characterized for a range of environmental conditions and power generation states in the coastal waters off southern California using a set of international technical specifications. Results from the international technical specification analyses were applied to United States regulatory threshold criteria for acoustic impacts to marine mammals and examined in the context of European underwater noise monitoring guidelines. Weighted 24 hour cumulative sound exposure levels SEL24h calculated from the highest power generation state WEC sound pressure levels were often more than 20 dB below threshold criteria for temporary threshold shifts in five relevant marine mammal hearing groups. Following European Union recommendations for analyses and reporting, WEC sound characterization in third octave bands centered at 63 Hz and 125 Hz show clear spatial decay of WEC-generated noise, with more pronounced attenuation at 63 Hz, and a less marked but still detectable gradient at 125 Hz, collectively suggesting a relatively confined acoustic footprint under the observed conditions. The value of the international technical specification approach is highlighted by the isolation of WEC sounds from the surrounding soundscape. This allows for a robust characterization of acoustic emissions through a range of device power generation and sea states. Furthermore, in threshold-based regulatory contexts like the U.S., this facilitates direct evaluation of source contributions, while in broader monitoring frameworks used in the E.U. it provides a reproducible foundation for assessing the contribution of emerging ocean energy technologies to the underwater acoustic environment.

Haxel, Joseph H. (ORCID:0000000273864761)↗

WE-D-BRA-06: IMRT QA with ArcCHECK: The MD Anderson Experience

Purpose: The objective of this project was to report our initial IMRT QA results and experience with the SunNuclear ArcCHECK. Methods: Three thousand one-hundred and sixteen cases were treated with IMRT or VMAT at our institution between October 2013 and September 2014. All IMRT/VMAT treatment plans underwent Quality Assurance (QA) using ArcCHECK prior to therapy. For clinical evaluation, a Gamma analysis is performed following QA delivery using the SNC Patient software (Sun Nuclear Corp) at the 3%/3mm level. QA Gamma pass rates were analyzed based on categories of treatment site, technique, and type of MLCs. Our current clinical threshold for passing a QA (Tclin) is set at a Gamma pass rate greater than 90%. We recorded the percent of failures for each category, as well as the Gamma pass rate threshold that would Result in 95% of QAs to pass (T95). Results: Using Tclin a failure rate of 5.9% over all QAs was observed. The highest failure rate was observed for gynecological (22%) and the lowest for CNS (0.9%) treatments. T95 was 91% over all QAs and ranged from 73% (gynecological) to 96.5% (CNS) for individual treatments sites. T95 was lower for IMRT and non-HD (high definition) MLCs at 88.5% and 94.5%, respectively, compared to 92.4% and 97.1% for VMAT and HD MLC treatments, respectively. There was a statistically significant difference between the passing rates for IMRT vs. VMAT and for HD MLCs vs. non-HD MLCs (p-values << 0.01). Gynecological, IMRT, and HD MLC treatments typically include more plans with larger field sizes. Conclusion: On average, Tclin with ArcCHECK was consistent with T95, as well as the 90% action level reported in TG-119. However, significant variations between the examined categories suggest a link between field size and QA passing rates and may warrant field size-specific passing rate thresholds.

60 APPLIED LIFE SCIENCES↗