Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laser Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Persistence of uranium emission in laser-produced plasmas

Detection of uranium and other nuclear materials is of the utmost importance for nuclear safeguards and security. Optical emission spectroscopy of laser-ablated U plasmas has been presented as a stand-off, portable analytical method that can yield accurate qualitative and quantitative elemental analysis of a variety of samples. In this study, optimal laser ablation and ambient conditions are explored, as well as the spatio-temporal evolution of the plasma for spectral analysis of excited U species in a glass matrix. Various Ar pressures were explored to investigate the role that plasma collisional effects and confinement have on spectral line emission enhancement and persistence. The plasma-ambient gas interaction was also investigated using spatially resolved spectra and optical time-of-flight measurements. The results indicate that ambient conditions play a very important role in spectral emission intensity as well as the persistence of excited neutral U emission lines, influencing the appropriate spectral acquisition conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared Scattering Scanning Near-Field Optical Microscopy Using An External Cavity Quantum Cascade Laser For Nanoscale Chemical Imaging And Spectroscopy of Explosive Residues

Infrared scattering scanning near-field optical microscopy (s-SNOM) is an apertureless superfocusing technique that uses the antenna properties of a conducting atomic force microscope (AFM) tip to achieve infrared spatial resolution below the diffraction limit. The instrument can be used either in imaging mode, where a fixed wavelength light source is tuned to a molecular resonance and the AFM raster scans an image, or in spectroscopy mode where the AFM is held stationary over a feature of interest and the light frequency is varied to obtain a spectrum. In either case, a strong, stable, coherent infrared source is required. Here we demonstrate the integration of a broadly tunable external cavity quantum cascade laser (ECQCL) into an s-SNOM and use it to obtain infrared spectra of microcrystals of chemicals adsorbed onto gold substrates. Residues of the explosive compound tetryl was deposited onto gold substrates. s-SNOM experiments were performed in the 1260-1400 cm-1 tuning range of the ECQCL, corresponding to the NO2 symmetric stretch vibrational fingerprint region. Vibrational infrared spectra were collected on individual chemical domains with a collection area of *500nm2 and compared to ensemble averaged far-field reflection-absorption infrared spectroscopy (RAIRS) results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft x-ray absorption spectroscopy of metalloproteins and high-valent metal-complexes at room temperature using free-electron lasers

X-ray absorption spectroscopy at the L-edge of 3d transition metals provides unique information on the local metal charge and spin states by directly probing 3d-derived molecular orbitals through 2p-3d transitions. However, this soft x-ray technique has been rarely used at synchrotron facilities for mechanistic studies of metalloenzymes due to the difficulties of x-ray-induced sample damage and strong background signals from light elements that can dominate the low metal signal. Here, we combine femtosecond soft x-ray pulses from a free-electron laser with a novel x-ray fluorescence-yield spectrometer to overcome these difficulties. We present L-edge absorption spectra of inorganic high-valent Mn complexes (Mn ∼ 6–15 mmol/l) with no visible effects of radiation damage. We also present the first L-edge absorption spectra of the oxygen evolving complex (Mn4CaO5) in Photosystem II (Mn < 1 mmol/l) at room temperature, measured under similar conditions. Our approach opens new ways to study metalloenzymes under functional conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental approaches for studying non-equilibrium atmospheric plasma jets

This work reviews recent research efforts undertaken in the area non-equilibrium atmospheric plasma jets with special focus on experimental approaches. Physics of small non-equilibrium atmospheric plasma jets operating in kHz frequency range at powers around few Watts will be analyzed, including mechanism of breakdown, process of ionization front propagation, electrical coupling of the ionization front with the discharge electrodes, distributions of excited and ionized species, discharge current spreading, transient dynamics of various plasma parameters, etc. Experimental diagnostic approaches utilized in the field will be considered, including Rayleigh microwave scattering, Thomson laser scattering, electrostatic streamer scatterers, optical emission spectroscopy, fast photographing, etc.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-Induced Plasma as a Method for the Metallic Materials Hardness Estimation: An Alternative Approach

The application of an alternative laser-induced breakdown spectroscopy (LIBS) method based on transversely excited atmospheric (TEA) CO2 laser was investigated for the first time for estimating the hardness of metallic materials. The human eye-safe (TEA) CO2 laser, operating at 10.6 µm, was used for plasma generation. The LIBS spectra were recorded by employing a cost-effective CCD camera for the time-integrated and spatial resolved measurements. The cast iron and aluminum alloys samples with different hardness have been tested. The ratio between the magnesium ionic and neutral lines in LIBS spectra was applied for estimating the material hardness. In addition, the hardness of all samples included in this study was determined using the conventional method for material hardness determination, i.e. Vickers hardness test. The linear dependence of magnesium lines intensity ratio on the sample’s hardness was obtained for both kinds of materials. Profilometric measurements were used to verify that the newly-introduced method is almost nondestructive for the investigated metals. The results obtained in the present work confirmed the potential of using this original LIBS system not only for the fast elemental analysis but also for the direct estimation of the hardness of metals and alloys. © 2020, Springer Science+Business Media, LLC, part of Springer Nature.

36 MATERIALS SCIENCE↗

Ion temperature evolution in an ultracold neutral plasma

We study the long-time evolution of the ion temperature in an expanding ultracold neutral plasma using spatially resolved, laser-induced-fluorescence spectroscopy. Adiabatic cooling reduces the ion temperature by an order of magnitude during the plasma expansion, to temperatures as low as 0.2 K. Cooling is limited by heat exchange between ions and the much hotter electrons. We also present evidence for an additional heating mechanism and discuss possible sources. Data are described by a model of the plasma evolution, including the effects of ion-electron heat exchange. We show that for appropriate initial conditions, the degree of Coulomb coupling of ions in the plasma increases during expansion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Ionization of Water under Extreme Conditions

Raman spectroscopy in a laser heated diamond anvil cell and first principles molecular dynamics simulations have been used to study water in the temperature range 300 to 1500 K and at pressures to 56 GPa. We find a substantial decrease in the intensity of the O-H stretch mode in the liquid phase with pressure, and a change in slope of the melting line at 47 GPa and 1000 K. Consistent with these observations, theoretical calculations show that water beyond 50 GPa is 'dynamically ionized' in that it consists of very short-lived (<10 fs) H{sub 2}O, H{sub 3}O{sup +}, and OH{sup -} species, and also that the mobility of the oxygen ions decreases abruptly with pressure, while hydrogen ions remain very mobile. We suggest that this regime corresponds to a superionic state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Volume Measurements of Laser-generated Pits for In Situ Geochronology using KArLE (Potassium-Argon Laser Experiment)

The Potassium-Argon Laser Experiment( KArLE), is composed of two main instruments: a spectrometer as part of the Laser-Induced Breakdown Spectroscopy (LIBS) method and a Mass Spectrometer (MS). The LIBS laser ablates a sample and creates a plasma cloud, generating a pit in the sample. The LIBS plasma is measured for K abundance in weight percent and the released gas is measured using the MS, which calculates Ar abundance in mols. To relate the K and Ar measurements, total mass of the ablated sample is needed but can be difficult to directly measure. Instead, density and volume are used to calculate mass, where density is calculated based on the elemental composition of the rock (from the emission spectrum) and volume is determined by pit morphology. This study aims to reduce the uncertainty for KArLE by analyzing pit volume relationships in several analog materials and comparing methods of pit volume measurements and their associated uncertainties.

French, R. A.↗

The CH2 b~1B1 - a~1 A1 Band Origin at 1.20 um

The origin band in the {tilde b}{sup 1}B{sub 1}-{tilde a}{sup 1}A{sub 1} transition of CH{sub 2} near 1.2 {mu}m has been recorded at Doppler-limited resolution using diode laser transient absorption spectroscopy. The assignments of rotational transitions terminating in upper state levels with K{sub a} = 0 and 1, were confirmed by ground state combination differences and extensive optical-optical double resonance experiments. The assigned lines are embedded in a surprisingly dense spectral region, which includes a strong hot band, {tilde b}(0,1,0) K{sub a} = 0 - {tilde a}(0,1,0) K{sub a} = 1 sub-band lines, with combination or overtone transitions in the {tilde a}{sup 1}A{sub 1} state likely responsible for the majority of unassigned transitions in this region. From measured line intensities and an estimate of the concentration of CH{sub 2} in the sample, we find the transition moment square for the 000 {l_arrow} 110 transition in the {tilde b}{sup 1}B{sub 1}(0,0,0)0-{tilde a}{sup 1}A{sub 1}(0,0,0)1 sub-band is 0.005(1) D{sup 2}. Prominent {tilde b}{sup 1}B{sub 1}(0,1,0)0-{tilde a}{sup 1}A{sub 1}(0,1,0)1 hot band lines were observed in the same spectral region. Comparison of the intensities of corresponding rotational transitions in the two bands suggests the hot band has an intrinsic strength approximately 28 times larger than the origin band. Perturbations of the excited state K{sub a} = 0 and 1 levels are observed and discussed. The new measurements will lead to improved future theoretical modeling and calculations of the Renner-Teller effect between the {tilde a} and {tilde b} states in CH{sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SuperCam One Step Closer to Mars

The SuperCam instrument -- designed, built and tested at Los Alamos National Laboratory in partnership with the French Space Agency -- and destined for the exploration of Mars has completed testing and evaluation at Los Alamos and is on its way to the Jet Propulsion Laboratory in California for full system integration. SuperCam will be one of two Los Alamos instruments on the next rover, called Mars 2020, an upgraded version of the current rover on Mars, Curiosity. SuperCam consists of a "mast unit" and "body unit, the mast unit, mounted on a mast on the exterior of the rover, is essentially a telescope with a laser, an extremely advanced version of Laser Induced Breakdown Spectroscopy, or LIBS, a technology invented at Los Alamos. The laser blasts a tiny portion of a geological formation, both rocks and soils on Mars, creating a plasma. The telescope then captures the spectra of the light emitted by the plasma. The body unit, mounted inside the body of the rover, is essentially a sophisticated spectrometer, and uses the light spectra to determine both the elemental and molecular composition of the sample, along with physical properties like hardness. Launch of the Mars 2020 mission is scheduled for late July, 2020, followed by the landing on Mars in February of 2021.

2020↗

The Influence of spot size on the expansion dynamics of nanosecond-laser-produced copper plasmas in atmosphere

Laser produced copper plasmas of different spot sizes in air were investigated using fast photography and optical emission spectroscopy (OES). The laser energy was 33 mJ. There were dramatic changes in the plasma plume expansion into the ambient air when spot sizes changed from {approx}0.1 mm to {approx}0.6 mm. A stream-like structure and a hemispherical structure were, respectively, observed. It appeared that the same spot size resulted in similar expansion dynamics no matter whether the target was located in the front of or behind the focal point, although laser-induced air breakdown sometimes occurred in the latter case. Plasma plume front positions agree well with the classic blast wave model for the large spot-size cases, while an unexpected stagnation of {approx}80 ns occurred after the laser pulse ends for the small spot size cases. This stagnation can be understood in terms of the evolution of enhanced plasma shielding effects near the plasma front. Axial distributions of plasma components by OES revealed a good confinement effect. Electron number densities were estimated and interpreted using the recorded Intensified Charge Coupled Device (ICCD) images.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of initial γ -irradiation on infrared laser ablation of poly(vinyl alcohol) studied by infrared spectroscopy

We report the effect of initial γ-irradiation of poly(vinyl alcohol) (PVA) on the kinetics of polymer ablation under CO 2 laser irradiation was studied using infra-red spectroscopy. The rate of laser ablation rapidly decreases with increasing time of laser ablation up to 10 s. Initial γ-irradiation of a dose up to 100 kGy reduces the rate of the laser ablation, just like the effect of laser exposure. The number of OH and CH groups decrease in PVA both with laser irradiation and with γ-irradiation. The number of OH groups decreases more under laser irradiation. Unsaturated bonds are formed in γ–irradiated PVA on the surface of the crater formed by laser ablation of the polymer that has undergone radiolysis. Increasing the dose of initial γ-irradiation from 100 to 2300 kGy leads to an increase in the intensity of the IR bands of the unsaturated bonds. The number of IR bands in the spectra of the laser ablation crater of PVA does not change with the dose of initial γ-irradiation. A dose of radiolysis of 3500 kGy significantly changes the IR spectra of both the ablation crater and the coating formed from the ablation products. Many bands characteristic for PVA are no longer present and the intensities of bands corresponding to unsaturated bonds are increased. A computational model for loss of water and ketone formation was developed for PVA and PVA including a diol using G3(MP2). The highest activation energy barrier step in the decomposition reaction was formation of the enol species and water was shown to catalyze all decomposition steps.

36 MATERIALS SCIENCE↗

Relative Defect Density Measurements of Laser Shock Peened 316L Stainless Steel Using Positron Annihilation Spectroscopy

The surface of an annealed 316L stainless steel coupon was laser shock peened and Vickers hardness measurements were subsequently taken of its surface. This Vickers hardness data was compared with measurements taken using the technique of positron annihilation Doppler broadening spectroscopy. When compared, a correlation was found between the Vickers hardness data measurements and those made using Doppler broadening spectroscopy. Although materials with a high defect density can cause the S-parameter measurements to saturate, variations in the Sparameter measurements suggest that through further research the Doppler broadening technique could be used as a viable alternative to measuring a material's hardness. In turn, this technique, could be useful in industrial settings where surface hardness and surface defects are used to predict lifetime of components.

36 MATERIALS SCIENCE↗

Quantitative comparison of organic photovoltaic bulk heterojunction photostability under laser illumination

The photostability of bulk heterojunction organic photovoltaic films containing a polymer donor and a fullerene-derivative acceptor was examined using resonance Raman spectroscopy and controlled laser power densities. The polymer donors were poly(3-hexylthiophene-2,5-diyl) (P3HT), poly[[9-(1-octylnonyl)-9H-carbazole-2,7-diyl]-2,5-thiophenediyl-2,1,3-benzothiadiazole-4,7-diyl-2,5-thiophenediyl] (PCDTBT), or poly({4,8-bis[(2-ethylhexyl)oxy]benzo[1,2-b:4,5-b']dithiophene-2,6-diyl}{3-fluoro-2-[(2-ethylhexyl)carbonyl]thieno[3,4-b]thiophenediyl}) (PTB7). Four sample preparation methods were studied: (i) thin or (ii) thick films with fast solvent evaporation under nitrogen, (iii) thick films with slow solvent evaporation under nitrogen, and (iv) thin films dried under nitrogen followed by thermal annealing. Polymer order was assessed by monitoring a Raman peak’s full width at half-maximum and location as a function of illumination time and laser power densities from 2.5 × 10 3 to 2.5 × 10 5 W cm –2 . Resonance Raman spectroscopy measurements show that before prolonged illumination, PCDTBT and PTB7 have the same initial order for all preparation conditions, while P3HT order improves with slow solvent drying or thermal annealing. All films exhibited changes to bulk heterojunction structure with 2.5 × 10 5 Wcm –2 laser illumination as measured by resonance Raman spectroscopy, and atomic force microscopy images show evidence of sample heating that affects the polymer over an area greater than the illumination profile. Furthermore, photostability data are important for proper characterization by techniques involving illumination and the development of devices suitable for real-world applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Femtosecond laser-induced modification of potassium-magnesium silicate glasses: An analysis of structural changes by near edge x-ray absorption spectroscopy

The effects of femtosecond laser pulse irradiation on the glass structure of alkaline silicate glasses were investigated by x-ray absorption near edge structure spectroscopy using the beamline of the Physikalisch-Technische Bundesanstalt at the electron synchrotron BESSY II in Berlin (Germany) by analyzing the magnesium K-edge absorption peak for different laser fluences. The application of fluences above the material modification threshold (2.1 J/cm{sup 2}) leads to a characteristic shift of {approx}1.0 eV in the K-edge revealing a reduced ({approx}3%) mean magnesium bond length to the ligated oxygen ions (Mg-O) along with a reduced average coordination number of the Mg ions.

36 MATERIALS SCIENCE↗

Single photon infrared emission spectroscopy: a study of IR emission from UV laser excited PAHs between 3 and 15 micrometers

Single-photon infrared emission spectroscopy (SPIRES) has been used to measure emission spectra from polycyclic aromatic hydrocarbons (PAHs). A supersonic free-jet expansion has been used to provide emission spectra of rotationally cold and vibrationally excited naphthalene and benzene. Under these conditions, the observed width of the 3.3-micrometers (C-H stretch) band resembles the bandwidths observed in experiments in which emission is observed from naphthalene with higher rotational energy. To obtain complete coverage of IR wavelengths relevant to the unidentified infrared bands (UIRs), UV laser-induced desorption was used to generate gas-phase highly excited PAHs. Lorentzian band shapes were convoluted with the monochromator-slit function in order to determine the widths of PAH emission bands under astrophysically relevant conditions. Bandwidths were also extracted from bands consisting of multiple normal modes blended together. These parameters are grouped according to the functional groups mostly involved in the vibration, and mean bandwidths are obtained. These bandwidths are larger than the widths of the corresponding UIR bands. However, when the comparison is limited to the largest PAHs studied, the bandwidths are slightly smaller than the corresponding UIR bands. These parameters can be used to model emission spectra from PAH cations and cations of larger PAHs, which are better candidate carriers of the UIRs.

Non-NASA Center↗

Phosphate-Induced Immobilization of Uranium in Hanford Sediments

Phosphate can be added to subsurface environments to immobilize U(VI) contamination. The efficacy of immobilization depends on the site-specific groundwater chemistry and aquifer sediment properties. Batch and column experiments were performed with sediments from the Hanford 300 Area in Washington State and artificial groundwater prepared to emulate the conditions at the site. Batch experiments revealed enhanced U(VI) sorption with increasing phosphate addition. X-ray absorption spectroscopy measurements of samples from the batch experiments found that U(VI) was predominantly adsorbed at conditions relevant to the column experiments and most field sites (low U(VI) loadings, <25 μM), and U(VI) phosphate precipitation occurred only at high initial U(VI) (>25μM) and phosphate loadings. While batch experiments showed the transition of U(VI) uptake from adsorption to precipitation, the column study was more directly relevant to the subsurface environment because of the high solid:water ratio in the column and the advective flow of water. In column experiments, nearly six times more U(VI) was retained in sediments when phosphate-containing groundwater was introduced to U(VI)-loaded sediments than when the groundwater did not contain phosphate. This enhanced retention persisted for at least one month after cessation of phosphate addition to the influent fluid. Sequential extractions and laser-induced fluorescence spectroscopy of sediments from the columns suggested that the retained U(VI) was primarily in adsorbed forms. These results indicate that in situ remediation of groundwater by phosphate addition provides lasting benefit beyond the treatment period via enhanced U(VI) adsorption to sediments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗