Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOAD TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Modeling and Characterization of Dynamic Failure of Soda-lime Glass Under High Speed Impact

In this paper, the impact-induced dynamic failure of a soda-lime glass block is studied using an integrated experimental/analytical approach. The Split Hopkinson Pressure Bar (SHPB) technique is used to conduct dynamic failure test of soda-lime glass first. The damage growth patterns and stress histories are reported for various glass specimen designs. Making use of a continuum damage mechanics (CDM)-based constitutive model, the initial failure and subsequent stiffness reduction of glass are simulated and investigated. Explicit finite element analyses are used to simulate the glass specimen impact event. A maximum shear stress-based damage evolution law is used in describing the glass damage process under combined compression/shear loading. The impact test results are used to quantify the critical shear stress for the soda-lime glass under examination.

glass, brittle failure, failure strength, damage m↗

Modeling and Characterization of Dynamic Failure of Glasses Under High Speed Impact

: In this chapter, the impact-induced dynamic failure of a glass block is studied using an integrated experimental/analytical approach. Both soda-lime and borosilicate glass materials are investigated. The Split Hopkinson Pressure Bar (SHPB) technique is used to conduct dynamic failure test of soda-lime glass first. The damage growth patterns and stress histories are reported for various glass specimen designs. Making use of a continuum damage mechanics (CDM)-based constitutive model, the initial failure and subsequent stiffness reduction of glass are simulated and investigated. Explicit finite element analyses are used to simulate the glass specimen impact event. A maximum shear stress-based damage evolution law is used in describing the glass damage process under combined compression/shear loading. The impact test results are used to quantify the critical shear stress for the soda-lime glass under examination.

continuum damage mechanics model↗

Hydrodynamic air lubricated compliant surface bearing for an automotive gas turbine engine. 2: Materials and coatings

Material coatings for an air-lubricated, compliant journal bearing for an automotive gas turbine engine were exposed to service test temperatures of 540 C or 650 C for 300 hours, and to 10 temperature cycles from room temperatures to the service test temperatures. Selected coatings were then put on journal and partial-arc foils and tested in start-stop cycle tests at 14 kPa (2 psi) loading for 2000 cycles. Half of the test cycles were performed at a test chamber service temperature of 540 C (1000 F) or 650 C (1200 F); the other half were performed at room temperature. Based on test results, the following combinations and their service temperature limitations are recommended: HL-800 TM (CdO and graphite) on foil versus chrome carbide on journal up to 370 C (700 F); NASA PS 120 (Tribaloy 400, silver and CaF2 on journal versus uncoated foil up to 540 C (1000 F); and Kaman DES on journal and foil up to 640 C (1200 F). Kaman DES coating system was further tested successfully at 35 kPa (5 psi) loading for 2000 start-stop cycles.

Bhushan, B.↗

Evaluation of the fuselage lap joint fatigue and terminating action repair

Terminating action is a remedial repair which entails the replacement of shear head countersunk rivets with universal head rivets which have a larger shank diameter. The procedure was developed to eliminate the risk of widespread fatigue damage (WFD) in the upper rivet row of a fuselage lap joint. A test and evaluation program has been conducted by Foster-Miller, Inc. (FMI) to evaluate the terminating action repair of the upper rivet row of a commercial aircraft fuselage lap splice. Two full scale fatigue tests were conducted on fuselage panels using the growth of fatigue cracks in the lap joint. The second test was performed to evaluate the effectiveness of the terminating action repair. In both tests, cyclic pressurization loading was applied to the panels while crack propagation was recorded at all rivet locations at regular intervals to generate detailed data on conditions of fatigue crack initiation, ligament link-up, and fuselage fracture. This program demonstrated that the terminating action repair substantially increases the fatigue life of a fuselage panel structure and effectively eliminates the occurrence of cracking in the upper rivet row of the lap joint. While high cycle crack growth was recorded in the middle rivet row during the second test, failure was not imminent when the test was terminated after cycling to well beyond the service life. The program also demonstrated that the initiation, propagation, and linkup of WFD in full-scale fuselage structures can be simulated and quantitatively studied in the laboratory. This paper presents an overview of the testing program and provides a detailed discussion of the data analysis and results. Crack distribution and propagation rates and directions as well as frequency of cracking are presented for both tests. The progression of damage to linkup of adjacent cracks and to eventual overall panel failure is discussed. In addition, an assessment of the effectiveness of the terminating action repair and the occurrence of cracking in the middle rivet row is provided, and conclusions of practical interest are drawn.

Samavedam, Gopal↗

Creep behavior of an additively manufactured 9Cr steel in the as-built condition

Limited studies have evaluated the creep behavior of additively manufactured (AM) ferritic-martensitic (FM) steels. This work investigated the creep behavior of a 9Cr FM steel fabricated by powder blown directed energy deposition (DED) technique. Here, the creep testing at 550–650 °C and 150 MPa for the specimens along the deposition direction in the as-built condition, together with corresponding microstructural characterization, revealed a threshold temperature between 600 and 625 °C, below which the steel has creep resistance comparable with Grade 91 cross-welds and noticeably greater than 9Cr-1Mo steel. The threshold temperature distinguishes the creep behavior in two regimes differentiated in creep activation energy, creep deformation, and failure mechanism. Unlike the creep rupture surface ~45° from the loading direction when tested above the threshold temperature, the creep rupture for testing below the threshold temperature resembles type IV failure in the cross-welds of ferritic steels. The DED-induced layer structure in the as-built steel played a significant role on the change of creep behavior.

36 MATERIALS SCIENCE↗

Parallel DSMC Solution of Three-Dimensional Flow Over a Finite Flat Plate

This paper describes a parallel implementation of the direct simulation Monte Carlo (DSMC) method. Runtime library support is used for scheduling and execution of communication between nodes, and domain decomposition is performed dynamically to maintain a good load balance. Performance tests are conducted using the code to evaluate various remapping and remapping-interval policies, and it is shown that a one-dimensional chain-partitioning method works best for the problems considered. The parallel code is then used to simulate the Mach 20 nitrogen flow over a finite-thickness flat plate. It is shown that the parallel algorithm produces results which compare well with experimental data. Moreover, it yields significantly faster execution times than the scalar code, as well as very good load-balance characteristics.

Nance, Robert P.↗

Performance Characterization of a Lithium-ion Gel Polymer Battery Power Supply System for an Unmanned Aerial Vehicle

Unmanned aerial vehicles (UAVs) are currently under development for NASA missions, earth sciences, aeronautics, the military, and commercial applications. The design of an all electric power and propulsion system for small UAVs was the focus of a detailed study. Currently, many of these small vehicles are powered by primary (nonrechargeable) lithium-based batteries. While this type of battery is capable of satisfying some of the mission needs, a secondary (rechargeable) battery power supply system that can provide the same functionality as the current system at the same or lower system mass and volume is desired. A study of commercially available secondary battery cell technologies that could provide the desired performance characteristics was performed. Due to the strict mass limitations and wide operating temperature requirements of small UAVs, the only viable cell chemistries were determined to be lithium-ion liquid electrolyte systems and lithium-ion gel polymer electrolyte systems. Two lithium-ion gel polymer cell designs were selected as candidates and were tested using potential load profiles for UAV applications. Because lithium primary batteries have a higher specific energy and energy density, for the same mass and volume allocation, the secondary batteries resulted in shorter flight times than the primary batteries typically provide. When the batteries were operated at lower ambient temperatures (0 to -20 C), flight times were even further reduced. Despite the reduced flight times demonstrated, for certain UAV applications, the secondary batteries operated within the acceptable range of flight times at room temperature and above. The results of this testing indicate that a secondary battery power supply system can provide some benefits over the primary battery power supply system. A UAV can be operated for hundreds of flights using a secondary battery power supply system that provides the combined benefits of rechargeability and an inherently safer chemistry.

Reid, Concha M.↗

Experimental Results From Stitched Composite Multi-Bay Fuselage Panels Tested Under Uni-Axial Compression

The experimental results from two stitched VARTM composite panels tested under uni-axial compression loading are presented. The curved panels are divided by frames and stringers into five or six bays with a column of three bays along the compressive loading direction. The frames are supported at the ends to resist out-of-plane translation. Back-to-back strain gages are used to record the strain and displacement transducers were used to record the out-of-plane displacements. In addition a full-field measurement technique that utilizes a camera-based-stero-vision system was used to record displacements. The panels were loaded in increments to determine the first bay to buckle. Loading was discontinued at limit load and the panels were removed from the test machine for impact testing. After impacting at 20 ft-lbs to 25 ft-lbs of energy with a spherical indenter, the panels were loaded in compression until failure. Impact testing reduced the axial stiffness 4 percent and less than 1 percent. Postbuckled axial panel stiffness was 52 percent and 70 percent of the pre-buckled stiffness.

Baker, Donald J.↗

Transient Three-Dimensional Startup Side Load Analysis of a Regeneratively Cooled Nozzle

The objective of this effort is to develop a computational methodology to capture the startup side load physics and to anchor the computed aerodynamic side loads with the available data from a regeneratively cooled, high-aspect-ratio nozzle, hot-fired at sea level. The computational methodology is based on an unstructured-grid, pressure-based, reacting flow computational fluid dynamics and heat transfer formulation, a transient 5 s inlet history based on an engine system simulation, and a wall temperature distribution to reflect the effect of regenerative cooling. To understand the effect of regenerative wall cooling, two transient computations were performed using the boundary conditions of adiabatic and cooled walls, respectively. The results show that three types of shock evolution are responsible for side loads: generation of combustion wave; transitions among free-shock separation, restricted-shock separation, and simultaneous free-shock and restricted shock separations; along with the pulsation of shocks across the lip, although the combustion wave is commonly eliminated with the sparklers during actual test. The test measured two side load events: a secondary and lower side load, followed by a primary and peak side load. Results from both wall boundary conditions captured the free-shock separation to restricted-shock separation transition with computed side loads matching the measured secondary side load. For the primary side load, the cooled wall transient produced restricted-shock pulsation across the nozzle lip with peak side load matching that of the test, while the adiabatic wall transient captured shock transitions and free-shock pulsation across the lip with computed peak side load 50% lower than that of the measurement. The computed dominant pulsation frequency of the cooled wall nozzle agrees with that of a separate test, while that of the adiabatic wall nozzle is more than 50% lower than that of the measurement. The computed teepee-like formation and the tangential motion of the shocks during lip pulsation also qualitatively agree with those of test observations. Moreover, a third transient computation was performed with a proportionately shortened 1 s sequence, and lower side loads were obtained with the higher ramp rate.

Wang, Ten-See↗

Evaluation of bead-stiffened metal panels

Potential weight efficiency for bead-stiffened panels has been demonstrated through fabrication and testing. Theoretically optimum design concepts were identified, and small specimens were tested under combined compression, shear, and bending to determine local buckling failure loads and to verify theory. Large optimized panels were then designed and tested under combined loads. Correlation of test data for large circular tubular panels with theory was conservative and consistent, and indicated reliable and acceptable design theory. Tests of fluted tubular panels indicated general instability failures at loads far below the design values due to nonlinear distortions. Further study of the fluted tubular configuration will be required if its potential weight efficiency is to be attained.

Shideler, J. L.↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Open Communication Networks on Load Frequency Control with Plug-In Electric Vehicles by Cyber-Physical Dynamic Co-Simulation

With the increasing electrification of the transportation sector to achieve the carbon neutrality objective, despite the challenges of charging electric vehicles (EV), there are also opportunities through smart charging EVs to improve system frequency stability; however, EV control technologies might require nontraditional communication support. This paper investigates the impacts of communication variations of EV on power system load frequency control through a cyber-physical dynamic system (CPDS) co-simulation. Here, the CPDS is built upon our previously developed transmission-and-distribution dynamic co-simulation model with the added communication variation functions (i.e., delay and packet loss). The case studies consider multiple communication variation scenarios when the system experiences an N-1 generation trip contingency. The scenarios include communication delays and packet loss using both homogeneous and heterogeneous assumptions. The outcomes of this work can help improve EV frequency regulation services and provide robust and effective tests for different load frequency control algorithms of the future power systems.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Use of Acoustic Emission to Monitor Progressive Damage Accumulation in Kevlar (R) 49 Composites

Acoustic emission (AE) data acquired during intermittent load hold tensile testing of epoxy impregnated Kevlar(Registeres TradeMark) 49 (K/Ep) composite strands were analyzed to monitor progressive damage during the approach to tensile failure. Insight into the progressive damage of K/Ep strands was gained by monitoring AE event rate and energy. Source location based on energy attenuation and arrival time data was used to discern between significant AE attributable to microstructural damage and spurious AE attributable to noise. One of the significant findings was the observation of increasing violation of the Kaiser effect (Felicity ratio < 1.0) with damage accumulation. The efficacy of three different intermittent load hold stress schedules that allowed the Felicity ratio to be determined analytically is discussed.

Waller, Jess M.↗

Modal Survey of ETM-3, A 5-Segment Derivative of the Space Shuttle Solid Rocket Booster

The complex interactions between internal motor generated pressure oscillations and motor structural vibration modes associated with the static test configuration of a Reusable Solid Rocket Motor have potential to generate significant dynamic thrust loads in the 5-segment configuration (Engineering Test Motor 3). Finite element model load predictions for worst-case conditions were generated based on extrapolation of a previously correlated 4-segment motor model. A modal survey was performed on the largest rocket motor to date, Engineering Test Motor #3 (ETM-3), to provide data for finite element model correlation and validation of model generated design loads. The modal survey preparation included pretest analyses to determine an efficient analysis set selection using the Effective Independence Method and test simulations to assure critical test stand component loads did not exceed design limits. Historical Reusable Solid Rocket Motor modal testing, ETM-3 test analysis model development and pre-test loads analyses, as well as test execution, and a comparison of results to pre-test predictions are discussed.

Nielsen, D.↗

Load Profile Inpainting for Missing Load Data Restoration and Baseline Estimation

This paper introduces a Generative Adversarial Nets (GAN) based, Load Profile Inpainting Network (Load-PIN) for restoring missing load data segments and estimating the baseline for a demand response event. The inputs are time series load data before and after the inpainting period together with explanatory variables (e.g., weather data). Here, we propose a Generator structure consisting of a coarse network and a fine-tuning network. The coarse network provides an initial estimation of the data segment in the inpainting period. The fine-tuning network consists of self-attention blocks and gated convolution layers for adjusting the initial estimations. Loss functions are specially designed for the fine-tuning and the discriminator networks to enhance both the point-to-point accuracy and realisticness of the results. We test the Load-PIN on three real-world data sets for two applications: patching missing data and deriving baselines of conservation voltage reduction (CVR) events. We benchmark the performance of Load-PIN with five existing deep-learning methods. Our simulation results show that, compared with the state-of-the-art methods, Load-PIN can handle varying-length missing data events and achieve 15-30% accuracy improvement.

14 SOLAR ENERGY↗

Out-of-Plane Restraint under Tension In-Plane Loading

The development and description of a test fixture designed to restrict out-of-plane motion in the center region of tension-loaded carbon-epoxy panels are presented herein. The test fixture was used to impose displacement conditions consistent with those in an analytical tool being developed to predict panel behavior in the vicinity of a central notch, which included the assumption that there would be no out-of-plane displacement and no buckling. However, pretest analysis using finite element models for a panel loaded without any out-of-plane restraint in the region of the notch indicated that with an imperfection magnitude equal to 20 percent of the thickness of the thin-skin panel, an unacceptable amount of out-of-plane deformation would occur as Poisson effects induced compression loads in the region of the notch. Therefore, to validate this tool in a test program, a restraint fixture which would suppress out-of-plane motion was required. The panel could not be encased in restraining plates because instrumentation and visibility were required in the vicinity of the notch. Therefore, a fixture that would restrict out-of-plane motion while still allowing access to the surface of the panel at the notch edges for instrumentation and line-of-sight access for cameras was required. To satisfy these requirements, a fixture was designed to restrict only out-of-plane motion near the center of the notch. Two 1.78-m-long test panels were loaded in tension to failure using this fixture. Out-of-plane deformations were not directly measured during testing, so back-to-back strain gages were used to obtain an indication of buckling. Strain results indicated that the restraint fixture performed as designed and buckling did not occur.

Fixtures↗

Out-of-Plane Restraint under Tension In-Plane Loading

The development and description of a test fixture designed to restrict out-of-plane motion in the center region of tension-loaded carbon-epoxy panels are presented herein. The test fixture was used to impose displacement conditions consistent with those in an analytical tool being developed to predict panel behavior in the vicinity of a central notch, which included the assumption that there would be no out-of-plane displacement and no buckling. However, pretest analysis using finite element models for a panel loaded without any out-of-plane restraint in the region of the notch indicated that with an imperfection magnitude equal to 20 percent of the thickness of the thin-skin panel, an unacceptable amount of out-of-plane deformation would occur as Poisson effects induced compression loads in the region of the notch. Therefore, to validate this tool in a test program, a restraint fixture which would suppress out-of-plane motion was required. The panel could not be encased in restraining plates because instrumentation and visibility were required in the vicinity of the notch. Therefore, a fixture that would restrict out-of-plane motion while still allowing access to the surface of the panel at the notch edges for instrumentation and line-of-sight access for cameras was required. To satisfy these requirements, a fixture was designed to restrict only out-of-plane motion near the center of the notch. Two 1.78-m-long test panels were loaded in tension to failure using this fixture. Out-of-plane deformations were not directly measured during testing, so back-to-back strain gages were used to obtain an indication of buckling. Strain results indicated that the restraint fixture performed as designed and buckling did not occur.

Composite structures↗