Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Mammographic quantitative image analysis and biologic image composition for breast lesion characterization and classification

Purpose: To investigate whether biologic image composition of mammographic lesions can improve upon existing mammographic quantitative image analysis (QIA) in estimating the probability of malignancy. Methods: The study population consisted of 45 breast lesions imaged with dual-energy mammography prior to breast biopsy with final diagnosis resulting in 10 invasive ductal carcinomas, 5 ductal carcinomain situ, 11 fibroadenomas, and 19 other benign diagnoses. Analysis was threefold: (1) The raw low-energy mammographic images were analyzed with an established in-house QIA method, “QIA alone,” (2) the three-compartment breast (3CB) composition measure—derived from the dual-energy mammography—of water, lipid, and protein thickness were assessed, “3CB alone”, and (3) information from QIA and 3CB was combined, “QIA + 3CB.” Analysis was initiated from radiologist-indicated lesion centers and was otherwise fully automated. Steps of the QIA and 3CB methods were lesion segmentation, characterization, and subsequent classification for malignancy in leave-one-case-out cross-validation. Performance assessment included box plots, Bland–Altman plots, and Receiver Operating Characteristic (ROC) analysis. Results: The area under the ROC curve (AUC) for distinguishing between benign and malignant lesions (invasive and DCIS) was 0.81 (standard error 0.07) for the “QIA alone” method, 0.72 (0.07) for “3CB alone” method, and 0.86 (0.04) for “QIA+3CB” combined. The difference in AUC was 0.043 between “QIA + 3CB” and “QIA alone” but failed to reach statistical significance (95% confidence interval [–0.17 to + 0.26]). Conclusions: In this pilot study analyzing the new 3CB imaging modality, knowledge of the composition of breast lesions and their periphery appeared additive in combination with existing mammographic QIA methods for the distinction between different benign and malignant lesion types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ORNL Biometric Eye Model for Iris Recognition

Iris recognition has been proven to be an accurate and reliable biometric. However, the recognition of non-ideal iris images such as off angle images is still an unsolved problem. We propose a new biometric targeted eye model and a method to reconstruct the off-axis eye to its frontal view allowing for recognition using existing methods and algorithms. This allows for existing enterprise level algorithms and approaches to be largely unmodified by using our work as a pre-processor to improve performance. In addition, we describe the `Limbus effect' and its importance for an accurate segmentation of off-axis irides. Our method uses an anatomically accurate human eye model and ray-tracing techniques to compute a transformation function, which reconstructs the iris to its frontal, non-refracted state. Then, the same eye model is used to render a frontal view of the reconstructed iris. The proposed method is fully described and results from synthetic data are shown to establish an upper limit on performance improvement and establish the importance of the proposed approach over traditional linear elliptical unwrapping methods. Our results with synthetic data demonstrate the ability to perform an accurate iris recognition with an image taken as much as 70 degrees off-axis.

Santos-Villalobos, Hector J↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Spectroscopy

Neutron detection provides an effective method to detect, locate, and characterize sources of interest to nuclear security applications. Current neutron imaging systems based on double-scatter kinematic reconstruction provide good signal vs. background discrimination and spectral capability, but suffer from poor sensitivity due to geometrical constraints. This weakness can be overcome if both neutron-proton scattering interactions are detected and resolved within one large contiguous active detector volume. We describe here a maximum likelihood approach to event reconstruction in a single-volume system with no optical segmentation and sensitivity to individual optical photons on the surfaces of the scintillator. We present results from a Geant4-based simulation establishing the feasibility of this single-volume neutron scatter camera concept given notional performance of existing photodetector and readout technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated profiling of three dimensional cell culture models and 3D microscopy

Motivation: Our goal is to develop a screening platform for quantitative profiling of colony organizations in 3D cell culture models. The 3D cell culture models, which are also imaged in 3D, are functional assays that mimic the in vivo characteristics of the tissue architecture more faithfully than the 2D cultures. However, they also introduce significant computational challenges, with the main barriers being the effects of growth conditions, fixations and inherent complexities in segmentation that need to be resolved in the 3D volume. Results: A segmentation strategy has been developed to delineate each nucleus in a colony that overcomes (i) the effects of growth conditions, (ii) variations in chromatin distribution and (iii) ambiguities formed by perceptual boundaries from adjacent nuclei. The strategy uses a cascade of geometric filters that are insensitive to spatial nonuniformity and partitions a clump of nuclei based on the grouping of points of maximum curvature at the interface of two neighboring nuclei. These points of maximum curvature are clustered together based on their coplanarity and proximity to define dissecting planes that separate the touching nuclei. The proposed curvature-based partitioning method is validated with both synthetic and real data, and is shown to have a superior performance against previous techniques. Validation and sensitivity analysis are coupled with the experimental design that includes a non-transformed cell line and three tumorigenic cell lines, which covers a wide range of phenotypic diversity in breast cancer. Colony profiling, derived from nuclear segmentation, reveals distinct indices for the morphogenesis of each cell line.

59 BASIC BIOLOGICAL SCIENCES↗

Retina Lesion and Microaneurysm Segmentation using Morphological Reconstruction Methods with Ground-Truth Data

In this work we report on a method for lesion segmentation based on the morphological reconstruction methods of Sbeh et. al. We adapt the method to include segmentation of dark lesions with a given vasculature segmentation. The segmentation is performed at a variety of scales determined using ground-truth data. Since the method tends to over-segment imagery, ground-truth data was used to create post-processing filters to separate nuisance blobs from true lesions. A sensitivity and specificity of 90% of classification of blobs into nuisance and actual lesion was achieved on two data sets of 86 images and 1296 images.

60 APPLIED LIFE SCIENCES↗

SU-G-206-15: Effects of Dose Reduction On Emphysema Score

Purpose: The purpose of this study was to investigate the effects of reducing radiation dose levels on emphysema scores from lung cancer screening CT exams. Methods: 52 cases were selected from the National Lung Screening Trial (NLST) patients for which we had both the image series and the raw CT data. All scans were acquired with fixed effective mAs (25 for standard-sized patients, 40 for large patients) on a 64-slice scanner (Sensation 64, Siemens Healthcare) using 120kV, 64×0.6mm collimation and pitch 1.0. All images were reconstructed with 1mm slice thickness, B50 kernel. Based on a previously-published technique, we added noise to the raw data to simulate reduced-dose versions at 50% and 25% of the original dose (approximately 1.0- and 0.5-mGy CTDIvol). Lung segmentations were obtained via region growing from manual seed point at a threshold of 600HU followed by manual removal of trachea and major airways. Lung segmentations were only performed on original dose scans, and mapped to simulated reduced-dose scans. Emphysema scores based on relative area of lung with attenuation values lower than −950HU (RA950) were computed for all cases. Results: Average RA950 of all 50 cases were 31.6 (±5.5), 32.5 (±4.9) and 32.8 (±4.6) for 100%, 50% and 25% dose level respectively. The average absolute difference in RA950 between simulated and original dose scans were 1.0 (±0.7) and 1.4 (±1.1) for 50% and 25% dose level respectively. Conclusion: RA950 is relatively robust to dose level, with a difference of no more than 5 from the original dose scans. The average RA950 of this population was high for a two reasons: This was a high risk population of patients with substantial smoking history; The use of B50 kernel, which may be biased towards high emphysema scores. Further exploration with smoother kernels will be conducted in the future. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH grant support from U01 CA181156.

60 APPLIED LIFE SCIENCES↗

Automated assessment of bilateral breast volume asymmetry as a breast cancer biomarker during mammographic screening

The biological concept of bilateral symmetry as a marker of developmental stability and good health is well established. Although most individuals deviate slightly from perfect symmetry, humans are essentially considered bilaterally symmetrical. Consequently, increased fluctuating asymmetry of paired structures could be an indicator of disease. There are several published studies linking bilateral breast size asymmetry with increased breast cancer risk. These studies were based on radiologists manual measurements of breast size from mammographic images. We aim to develop a computerized technique to assess fluctuating breast volume asymmetry in screening mammograms and investigate whether it correlates with the presence of breast cancer. Using a large database of screening mammograms with known ground truth we applied automated breast region segmentation and automated breast size measurements in CC and MLO views using three well established methods. All three methods confirmed that indeed patients with breast cancer have statistically significantly higher fluctuating asymmetry of their breast volumes. However, statistically significant difference between patients with cancer and benign lesions was observed only for the MLO views. The study suggests that automated assessment of global bilateral asymmetry could serve as a breast cancer risk biomarker for women undergoing mammographic screening. Such biomarker could be used to alert radiologists or computer-assisted detection (CAD) systems to exercise increased vigilance if higher than normal cancer risk is suspected.

Williams, Alex C↗

Retina Lesion and Microaneurysm Segmentation using Morphological Reconstruction Methods with Ground-Truth Data

In this work we report on a method for lesion segmentation based on the morphological reconstruction methods of Sbeh et. al. We adapt the method to include segmentation of dark lesions with a given vasculature segmentation. The segmentation is performed at a variety of scales determined using ground-truth data. Since the method tends to over-segment imagery, ground-truth data was used to create post-processing filters to separate nuisance blobs from true lesions. A sensitivity and specificity of 90% of classification of blobs into nuisance and actual lesion was achieved on two data sets of 86 images and 1296 images.

60 APPLIED LIFE SCIENCES↗

SU-D-18A-07: Towards 6-Degree-Of-Freedom Real-Time Motion Management in Cancer Radiotherapy

Purpose: Lung tumor motion has been identified as a major issue that deteriorates treatment efficacy for radiotherapy, especially for SBRT. As tighter PTV margins are applied due to translational compensation, tumor rotation will become the dominant factor limiting tumor targeting accuracy. This is the world-first study quantifies lung tumor rotation by utilizing kV images with fiducial markers and a step towards 6-degree-of-freedom real-time cancer radiotherapy. Methods: Three or four gold coils were implanted as tumor surrogates in 3 lung cancer patients. 50 fractions of 8- minute, 10 Hz 4D CBCT projections were acquired for the patients immediately prior or after radiotherapy. The fiducial marker positions are segmented, reconstructed and used to determine tumour rotation by the iterative closest point algorithm. Different data acceptance and filtering methods were applied to accept data or smooth the marker trajectory. Results: The average rotation angles around the left/ right (LR), superior/inferior (SI), anterior/posterior (AP) rotations were found to be 0.8±4.2, -0.8±4.5 and 1.7±3.1 degrees respectively. For 28% of the treatment time, the lung tumors rotated more than 5° around the SI axis. Respiration-induced rotational motion was detected in 2 of the 3 lung patients. This can be explained by the patient developed atelectasis during the treatment period. Interestingly, no heart beating component of rotation was observed in the power spectrum. Different rotational types were observed within the patient cohort with large variations in the magnitude of the rotation between patients. Conclusions: For the first time, continuous tumor rotation has been measured for lung patients with gold fiducial markers. Tumors were found to undergo rotations of more than 5° for almost a third of the total treatment time. The study also demonstrated the feasibility of using continuously kV images for real-time lung tumour motion adaptive radiotherapy which can potentially reduce treatment margins and side effects. The authors acknowledge the financial support of an NHMRC Australia Fellowship.

60 APPLIED LIFE SCIENCES↗

MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck

Computational modeling and simulations are increasingly being used to complement experimental testing for analysis of safety and efficacy of medical devices. Multiple voxel- and surface-based whole- and partial-body models have been proposed in the literature, typically with spatial resolution in the range of 1–2 mm and with 10–50 different tissue types resolved. We have developed a multimodal imaging-based detailed anatomical model of the human head and neck, named “MIDA”. The model was obtained by integrating three different magnetic resonance imaging (MRI) modalities, the parameters of which were tailored to enhance the signals of specific tissues: i) structural T1- and T2-weighted MRIs; a specific heavily T2-weighted MRI slab with high nerve contrast optimized to enhance the structures of the ear and eye; ii) magnetic resonance angiography (MRA) data to image the vasculature, and iii) diffusion tensor imaging (DTI) to obtain information on anisotropy and fiber orientation. The unique multimodal high-resolution approach allowed resolving 153 structures, including several distinct muscles, bones and skull layers, arteries and veins, nerves, as well as salivary glands. The model offers also a detailed characterization of eyes, ears, and deep brain structures. A special automatic atlas-based segmentation procedure was adopted to include a detailed map of the nuclei of the thalamus and midbrain into the head model. The suitability of the model to simulations involving different numerical methods, discretization approaches, as well as DTI-based tensorial electrical conductivity, was examined in a case-study, in which the electric field was generated by transcranial alternating current stimulation. The voxel- and the surface-based versions of the models are freely available to the scientific community.

59 BASIC BIOLOGICAL SCIENCES↗

A New Geometric Method Based on Two-Dimensional Transmission Electron Microscopy for Analysis of Interior versus Exterior Pd Loading on Hollow Carbon Nanofibers

Hallow carbon nanofibers (CNFs) are being explored as catalyst supports because of their unique properties; catalytic activities with both interior and exterior metal loadings are being evaluated. Electron tomography (3D transmission electron microscopy, 3D TEM) has been used to estimate internal versus external loading of metal nanoclusters. However, this method is time consuming and requires a specialized TEM. We prepared three hollow CNF supported Pd samples with various Pd localizations, and developed a geometric analysis method based on 2D TEM images to estimate Pd internal versus external loading percentages. Results show the similar localization for the same sample in terms of the number, surface area, and mass of Pd nanoclusters but distinct values for different samples. To test our method, we compare results for one segment of a CNF using both 3D scanning transmission electron microscopy (3D TEM) and our new 2D geometic analysis method. Agreement is within 15.1%. Our results also agree with 3D TEM results from the literature for similarly prepared Pd on CNFs (within 5.6%). Our geometric analysis method is proposed as a more straightforward and fast way to evaluate metal nanocluster localizations on tubular supports.

2D↗

A prototype compton camera for in-vivo dosimetry of ion beam cancer irradiation

Three-dimensional in-vivo dose monitoring of ion beam cancer irradiation can improve the quality of treatment. For this purpose we investigate the feasibility of imaging the single photon emissions due to nuclear reactions of projectiles with target nuclei (in-beam SPECT). A suitable imaging technique in the energy range of the emitted gamma rays is the Compton camera. A prototype based on prior simulations is currently under construction. Te system comprises two CdZnTe cross-strip detectors with steering grid and depth-of-interaction capability and one segmented LSO scintillator crystal with modified Anger light readout. We present the concept of the system including the front-end and DAQ electronics as well as first measurements. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding hadronic interactions using advanced reconstruction techniques

ProtoDUNE-SP served as the prototype of the future Deep Underground Neutrino Experiment (DUNE). With a total liquid argon mass of 0.77 kt, it stood as the most extensive monolithic single-phase Liquid Argon Time Projection Chamber (LArTPC) ever constructed. Strategically located and operated at CERN, ProtoDUNE-SP benefited from a specialized charged-particle test beam, offering a momentum range of 0.3 - 7 GeV/c. This setup provided a unique opportunity to conduct in-depth studies on hadronic interactions within argon. Hadronic interactions play a fundamental role in neutrino physics, particularly in the intricacies of neutrino detection. We depend on analyzing the outcomes of these interactions to accurately determine both the flavor and energy of the interacting neutrinos. Pions, as one of the primary byproducts of neutrino interactions, are crucial for understanding the overall dynamics and kinematics of these processes. Accurately characterizing and understanding the interaction of pions with argon can significantly enhance the precision of neutrino simulations and measurements.Being a Liquid Argon Time Projection Chamber (LArTPC), ProtoDUNE-SP is distinguished by its ability to produce high-definition images of charged particles as they traverse through the detector's active volume. Yet, accurately reconstructing these particle interactions and determining their kinematic attributes remains a challenging task. The successes of deep learning in diverse domains, especially in image recognition, provide a promising approach for addressing this challenge in ProtoDUNE. This thesis discusses a measurement of the Piplus - argon inelastic cross section in the energy range of 2400 to 3000 MeV, using data taken by protoDUNE during the fall of 2018. Additionally, panoptic segmentation, a machine learning technique, is introduced and validated through its application in the reconstruction of the neutral pion rest mass. The aim is to showcase how these advanced methods can enhance the quality of event reconstruction.

Sarasty Segura, Carlos Eduardo↗

A set of 4D pediatric XCAT reference phantoms for multimodality research

Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected to best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized models for the cardiac and respiratory motions. Based on patient data, the phantoms capture the anatomic variations of childhood, such as the development of bone in the skull, pelvis, and long bones, and the growth of the vertebrae and organs. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: The development of patient-derived pediatric computational phantoms is useful in providing variable anatomies for simulation. Future work will expand this ten-phantom base to a host of pediatric phantoms representative of the public at large. This can provide a means to evaluate and improve pediatric imaging devices and to optimize CT protocols in terms of image quality and radiation dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Symmetries of migration related segments of all [001] coincidence site lattice tilt boundaries in (001) projections for all holohedral cubic materials

Utilizing bicrystallography in two dimensions (2D), the symmetries of migration related segments of Coincidence Site Lattice (CSL) boundaries are derived for projections along their [001] tilt axis in grain boundaries of crystalline materials that possess the holohedral point symmetry of the cubic system (i.e. m3m). These kinds of “edge-on” projections are typical for atomic resolution imaging of such tilt boundaries with Transmission Electron Microscopes (TEM). This fact facilitates the visual confirmation of our predictions by recently published Zcontrast scanning TEM investigations [H. Yang et al., Phil. Mag. 93 (2013) 1219] and many other TEM studies.

Coincidence Site Lattice (CSL) boundaries↗

Relocation of Light and Moderate-Magnitude ( M 4-6) Seismicity Along the Central Mid-Atlantic

In this study, we estimate precise relative epicentroid locations of earthquakes along the Mid-Atlantic Ridge (MAR) between 12°N and 19°N using intermediate-period Rayleigh and Love wave cross-correlation measurements. We relocate 152 earthquakes with magnitudes ranging between 4.0 and 6.0 and when possible use P waveform modeling to estimate centroid depths. We compare surface-wave locations to locations in the U.S. Geological Survey, Global Centroid Moment Tensor, and Pacific Marine Environmental Laboratory hydroacoustic catalogs (Smith et al., 2002, https://doi.org/10.1029/2001GL013912) and demonstrate that surface-wave based relative location techniques provide significant improvement on precision. Our analyses shift locations to more tectonically consistent alignments that correlate strongly with bathymetric features. Relocations along the Fifteen-Twenty and Marathon Fracture Zones (FZs) move to within a few kilometers of the transform bathymetry. Events along ridge segments scatter over a distance of about 10–20 km perpendicular to the local plate boundary and most ridge-segment seismicity clusters spatially. North of the Fifteen-Twenty FZ, ridge events along several segments locate preferentially in the North American Plate, suggesting recent asymmetric seismic strain release and perhaps asymmetric spreading. Along the ridge between 13°N and 14°N, moderate-magnitude seismic strain release concentrates in an area with two active oceanic core complexes (OCC) along the western rift boundary, but the largest events along this segment appear to occur along the eastern boundary rift valley faults and represent deformation opposite the OCC detachment surface processes. Finally, precise moderate-magnitude earthquake epicentroid locations for events that occurred over the last few decades complement the results of temporary seismometer deployments that have imaged microseismic activity along the MAR.

58 GEOSCIENCES↗

MULTI-STRANDED AND MULTI-THERMAL SOLAR CORONAL LOOPS: EVIDENCE FROM HINODE X-RAY TELESCOPE AND EUV IMAGING SPECTROMETER DATA

Data from the X-Ray Telescope (XRT) and the EUV Imaging Spectrometer (EIS) on the Japanese/USA/UK Hinode spacecraft were used to investigate the spatial and thermal properties of an isolated quiescent coronal loop. We constructed differential emission measure (DEM) curves using Monte Carlo based, iterative forward fitting algorithms. We studied the loop as a whole, in segments, in transverse cuts, and point-by-point, always with some form of background subtraction, and find that the loop DEM is neither isothermal nor extremely broad, with approximately 96% of the EM between 6.2 {<=}log T{<=} 6.7, and an EM-weighted temperature of log T = 6.48 {+-} 0.16. We find evidence for a gradual change in temperature along the loop, with log T increasing only by {approx}0.1 from the footpoints to the peak. The combine XRT-EIS data set does a good job of constraining the temperature distribution for coronal loop plasma. Our studies show that the strong constraints at high and low temperatures provided by the combined data set are crucial for obtaining reasonable solutions. These results confirm that the observations of at least some loops are not consistent with isothermal plasma, and therefore cannot be modeled with a single flux tube and must be multi-stranded.

79 ASTRONOMY AND ASTROPHYSICS↗

Semantics-enabled Spatio-Temporal Modeling of Earth Observation Data: An application to Flood Monitoring

Extreme events such as urban floods are dynamic in nature, i.e. they evolve with time. The spatiotemporal analysis of such disastrous events is important for understanding the resiliency of an urban system during these events. Remote Sensing (RS) data is one of the crucial earth observation (EO) data sources that can facilitate such spatiotemporal analysis due to its wide spatial coverage and high temporal availability. In this paper, we propose a discrete mereotopology (DM) based approach to enable representation and querying of spatiotemporal information from a series of multitemporal RS images that are acquired during a flood disaster event. We represent this spatiotemporal information using a semantic model called Dynamic Flood Ontology (DFO). To establish the effectiveness and applicability of the proposed approach, spatiotemporal queries relevant during an urban flood scenario such as, show me road segments that were partially flooded during the time interval t1 have been demonstrated with promising results.

Kurte, Kuldeep↗