Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Exoplanet Sciences with Nulling Interferometers and a Single-mode Fiber-fed Spectrograph

Understanding the atmospheres of exoplanets is a milestone to decipher their formation history and potential habitability. High-contrast imaging and spectroscopy of exoplanets is the major pathway toward the goal. Direct imaging of an exoplanet requires high spatial resolution. Interferometry has proven to be an effective way of improving spatial resolution. However, means of combining interferometry, high-contrast imaging, and high-resolution spectroscopy have been rarely explored. To fill in the gap, we present the dual-aperture fiber nuller (FN) for current-generation 8–10 m telescopes, which provides the necessary spatial and spectral resolution to (1) conduct follow-up spectroscopy of known exoplanets and (2) detect planets in debris-disk systems. The concept of feeding an FN to a high-resolution spectrograph can also be used for future space and ground-based missions. We present a case study of using the dual-aperture FN to search for biosignatures in rocky planets around M stars for a future space interferometry mission. Moreover, we discuss how an FN can be equipped on future extremely large telescopes by using the Giant Magellan Telescope as an example.

79 ASTRONOMY AND ASTROPHYSICS↗

The Stellar Imager (SI) Project: A Deep Space UV/Optical Interferometer (UVOI) to Observe the Universe at 0.1 Milli-Arcsec Angular Resolution

The Stellar Imager (SI) is a space-based, UV/ Optical Interferometer (UVOI) designed to enable 0.1 milliarcsecond (mas) spectral imaging of stellar surfaces and of the Universe in general. It will also probe via asteroseismology flows and structures in stellar interiors. SI's science focuses on the role of magnetism in the Universe and will revolutionize our understanding, of the formation of planetary systems, of the habitability and climatology of distant planets, and of many magneto-hydrodynamically controlled processes, such as accretion, in the Universe. The ultra-sharp images of SI will revolutionize our view of many dynamic astrophysical processes by transforming point sources into extended sources, and snapshots into evolving views. SI is a "Flagship and Landmark Discovery Mission" in the 2005 Heliophysics Roadmap and a potential implementation of the UVOI in the 2006 Science Program for NASA's Astronomy and Physics Division. We present here the science goals of the SI Mission, a mission architecture that could meet those goals, and the technology development needed to enable this missin. Additional information on SI can be found at: http://hires.gsfc.nasa.gov/si/.

Carpenter, Kenneth G.↗

Properties of the Binary Black Hole Merger GW150914

On September 14, 2015, the Laser Interferometer Gravitational-Wave Observatory (LIGO) detected a gravitational-wave transient (GW150914); we characterize the properties of the source and its parameters. The data around the time of the event were analyzed coherently across the LIGO network using a suite of accurate waveform models that describe gravitational waves from a compact binary system in general relativity. GW150914 was produced by a nearly equal mass binary black hole of masses 36(+5/-4) solar mass and 29(+4/-4) solar mass; for each parameter we report the median value and the range of the 90% credible interval. The dimensionless spin magnitude of the more massive black hole is bound to be less than 0.7 (at 90% probability). The luminosity distance to the source is 410(+160/-180) Mpc, corresponding to a redshift 0.09(+0.03/−0.04) assuming standard cosmology. The source location is constrained to an annulus section of 610 sq deg, primarily in the southern hemisphere. The binary merges into a black hole of mass 62(+4/−4) solar mass and spin 0.67(+0.05/−0.07). This black hole is significantly more massive than any other inferred from electromagnetic observations in the stellar-mass regime.

Abbott, B. P.↗

Optimal light beams and mirror shapes for future LIGO interferometers

We report the results of a recent search for the lowest value of thermal noise that can be achieved in LIGO by changing the shape of mirrors, while fixing the mirror radius and maintaining a low diffractional loss. The result of this minimization is a beam with thermal noise a factor of 2.32 (in power) lower than previously considered Mesa Beams and a factor of 5.45 (in power) lower than the Gaussian beams employed in the current baseline design. Mirrors that confine these beams have been found to be roughly conical in shape, with an average slope approximately equal to the mirror radius divided by arm length, and with mild corrections varying at the Fresnel scale. Such a mirror system, if built, would impact the sensitivity of LIGO, increasing the event rate of observing gravitational waves in the frequency range of maximum sensitivity roughly by a factor of 3 compared to an Advanced LIGO using Mesa beams (assuming all other noises remain unchanged). We discuss the resulting beam and mirror properties and study requirements on mirror tilt, displacement, and figure error, in order for this beam to be used in LIGO detectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impact of mergers on LISA parameter estimation for nonspinning black hole binaries

We investigate the precision with which the parameters describing the characteristics and location of nonspinning black hole binaries can be measured with the Laser Interferometer Space Antenna (LISA). By using complete waveforms including the inspiral, merger, and ringdown portions of the signals, we find that LISA will have far greater precision than previous estimates for nonspinning mergers that ignored the merger and ringdown. Our analysis covers nonspinning waveforms with moderate mass ratios, q{>=}1/10, and total masses 10{sup 5} < or approx. M/M{sub {center_dot}}< or approx. 10{sup 7}. We compare the parameter uncertainties using the Fisher-matrix formalism, and establish the significance of mass asymmetry and higher-order content to the predicted parameter uncertainties resulting from inclusion of the merger. In real-time observations, the later parts of the signal lead to significant improvements in sky-position precision in the last hours and even the final minutes of observation. For comparable-mass systems with total mass M/M{sub {center_dot}{approx}1}0{sup 6}, we find that the increased precision resulting from including the merger is comparable to the increase in signal-to-noise ratio. For the most precise systems under investigation, half can be localized to within O(10 arcmin), and 10% can be localized to within O(1 arcmin).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Method of optical coherence tomography with parallel depth-resolved signal reception and fibre-optic phase modulators

The method of optical coherence tomography with the scheme of parallel reception of the interference signal (P-OCT) is developed on the basis of spatial paralleling of the reference wave by means of a phase diffraction grating producing the appropriate time delay in the Mach–Zehnder interferometer. The absence of mechanical variation of the optical path difference in the interferometer essentially reduces the time required for 2D imaging of the object internal structure, as compared to the classical OCT that uses the time-domain method of the image construction, the sensitivity and the dynamic range being comparable in both approaches. For the resulting field of the interfering object and reference waves an analytical expression is derived that allows the calculation of the autocorrelation function in the plane of photodetectors. For the first time a method of linear phase modulation by 2π is proposed for P-OCT systems, which allows the use of compact high-frequency (a few hundred kHz) piezoelectric cell-based modulators. For the demonstration of the P-OCT method an experimental setup was created, using which the images of the inner structure of biological objects at the depth up to 1 mm with the axial spatial resolution of 12 μm were obtained. (optical coherence tomography)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of precision weak-link stage systems with large travel range and sub-nanometer-scale resolution

To use x-ray optics with nanometer resolution limit, scanning x-ray nanoprobes with corresponding mechanical positioning capability need to be designed. In particular, positioning stages with both sub-nanometer resolution and a positioning/scanning range of several millimeters are required. Based on our design of precision weak-link stages with interferometric encoders for the Center for Nanoscale Materials (CNM) hard x-ray nanoprobe at the Advanced Photon Source (APS) Sector 26, we have developed a new two-dimensional (2-D) weak-link stage system for nanopositioning of a specimen holder. This system provides sub-nanometer resolution, coupled with sub-nanometer metrology at a travel range of several millimeters. The 2-D weak-link stage system is designed with high structure stiffness using laminar overconstrained weak-link mechanisms [4-6]. In this paper we present the study of a linear precision weak-link stage system with sub-centimeter travel range and sub-nanometer positioning resolution. Design of a rotary weak-link stage system with 10-nrad resolution and 10-degree-level travel range is also discussed in this paper.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Measurements of the plasma density in the FTU tokamak by a pulsed time-of-flight X-wave refractometer

On-line control over the plasma density in tokamaks (especially, in long-term discharges) requires reliable measurements of the averaged plasma density. For this purpose, a new method of density measurements-a pulsed time-of-flight plasma refractometry-was developed and tested in the T-11M tokamak. This method allows one to determine the averaged density from the measured time delay of nanosecond microwave pulses propagating through the plasma. For an O-wave, the measured time delay is proportional to the line-averaged density and is independent of the density profile (f>>f{sub p}) {tau}{sub o} {approx} k{sub o} 1/f{sup 2} {integral}{sub l} N(x)dx. Here, f is the frequency of the probing wave, f{sub p} is the plasma frequency, l= 4 a is the path length for two-pass probing in the equatorial plane, a is the plasma minor radius, k{sub O} and k{sub X} are numerical factors, f{sub c} is the electron-cyclotron frequency at the axis of the plasma column, and f{sub p}>>f{sub c}, f. Measurements of the time delay provide the same information as plasma interferometry, though they do no employ the effect of interference. When the conditions f{sub p}>>f{sub c}, f are not satisfied, the measured time delay depends on the shape of the density profile. In this case, in order to determine the average density regardless of the density profile, it is necessary to perform simultaneous measurements at several probing frequencies in order to determine the average density. In ITER (Bt {approx} 5T), a spectral window between the lower and upper cutoff frequencies in the range of 50-100 GHz can be used for pulsed time-of-flight X-wave refractometry. This appreciably simplifies the diagnostics and eliminates the problem of the first mirror. In this paper, the first results obtained in the FTU tokamak with a prototype of the ITER pulsed time-of-flight refractometer are presented. The geometry and layout of experiments similar to the planned ITER experiments are described. The density measured by pulsed time-of-flight refractometry is shown to agree well with the results obtained in FTU with a two-frequency scanning IR interferometer. The results obtained are analyzed, and the future experiments are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Connecting Current and Future Dual Active Galactic Nucleus Searches to LISA and Pulsar Timing Array Gravitational-wave Detections

Abstract Dual active galactic nuclei (DAGN) mark the observable stage of massive black hole (MBH) pairing during galaxy mergers and are the progenitors of the MBH binaries that generate low-frequency gravitational waves. Using the large-volume ASTRID cosmological simulation, we construct mock DAGN catalogs tailored to the selection functions of current (COSMOS-Web and DESI) and forthcoming (Nancy Grace Roman Space Telescope (Roman) and Lynx X-ray Observatory (Lynx)) surveys, enabling direct comparisons between simulations and observations. With realistic observational selections, ASTRID reproduces the observed dual fractions, projected separations, and host-galaxy properties across redshifts. We predict a substantial population of small-separation (<5 kpc) duals that remain inaccessible to current surveys, demonstrating that the apparent paucity of subkiloparsec systems in COSMOS-Web is primarily a consequence of observational selection rather than an intrinsic absence. Following each simulated dual to coalescence, we show that DAGN are effective tracers of MBH mergers: ∼30%–70% merge within ≲1 Gyr, and 20%–60% of these mergers produce gravitational-wave signals detectable by the Laser Interferometer Space Antenna (LISA). Duals observable with Roman and Lynx are the progenitors of ∼10%–50% of low-redshift LISA sources and contribute ∼30% of the PTA-band stochastic gravitational-wave background. We further identify massive green-valley galaxies hosting moderate-luminosity active galactic nuclei (AGN), together with massive star-forming galaxies containing bright quasars at z > 1, as the environments most likely to host imminent MBH binaries. These results establish a unified cosmological framework connecting DAGN demographics, MBH binary evolution, and gravitational-wave sources, while identifying high-priority targets for coordinated electromagnetic and multimessenger observations in the coming decade.

Chen, Nianyi [Max-Planck-Institut für Astrophysik;↗

The M.I.T. Ku-band radio interferometer.

The construction of a Ku-band radio interferometer and some preliminary observations are reported. The interferometer was built for the purpose of mapping discrete radio sources like the Crab Nebula, Cassiopeia A, and Cygnus A. It has two 8-ft parabolic antennas operating at 17.128 GHz. The maximum baseline of 100 m corresponds to a resolution of 35 sec of arc. A PDP-8 computer is incorporated in the system and is used for pointing, tracking, delay compensation, and real-time data analysis. The phase stability of the system was better than 10 deg over a period of 2 hours. Consistent fringe components were obtained from the Crab Nebula with a baseline set at 8 m.

Papadopoulos, G. D.↗

Fuel spray diagnostics

Several laser measurement methods are being studied to provide the capability to make droplet size and velocity measurements under a variety of spray conditions. The droplet sizing interferometer (DSI) promises to be a successful technique because of its capability for rapid data acquisition, compilation and analysis. Its main advantage is the ability to obtain size and velocity measurements in air-fuel mixing studies and hot flows. The existing DSI at NASA Lewis is a two-color, two-component system. Two independent orthogonal measurements of size and velocity components can be made simultaneously. It also uses an off-axis large-angle light scatter detection. The fundamental features of the system are optics, signal processing and data management system. The major component includes a transmitter unit, two receiver units, two signal processors, two data management systems, two Bragg cell systems, two printer/plotters, a laser, power supply and color monitor.

Bosque, M. A.↗

Infrared Submillimeter and Radio Astronomy Research and Analysis Program

This program entitled "Infrared Submillimeter and Radio Astronomy Research and Analysis Program" with NASA-Ames Research Center (ARC) was proposed by the Smithsonian Astrophysical Observatory (SAO) to cover three years. Due to funding constraints only the first year installment of $18,436 was funded, but this funding was spread out over two years to try to maximize the benefit to the program. During the tenure of this contact, the investigators at the SAO, Drs. Wesley A. Traub and Nathaniel P. Carleton, worked with the investigators at ARC, Drs. Jesse Bregman and Fred Wittebom, on the following three main areas: 1. Rapid scanning SAO and ARC collaborated on purchasing and constructing a Rapid Scan Platform for the delay arm of the Infrared-Optical Telescope Array (IOTA) interferometer on Mt. Hopkins, Arizona. The Rapid Scan Platform was tested and improved by the addition of stiffening plates which eliminated a very small but noticeable bending of the metal platform at the micro-meter level. 2. Star tracking Bregman and Wittebom conducted a study of the IOTA CCD-based star tracker system, by constructing a device to simulate star motion having a specified frequency and amplitude of motion, and by examining the response of the tracker to this simulated star input. 3. Fringe tracking. ARC, and in particular Dr. Robert Mah, developed a fringe-packet tracking algorithm, based on data that Bregman and Witteborn obtained on IOTA. The algorithm was tested in the laboratory at ARC, and found to work well for both strong and weak fringes.

Traub, Wesley A.↗

System and method for determination of the reflection wavelength of multiple low-reflectivity bragg gratings in a sensing optical fiber

A system and method for determining a reflection wavelength of multiple Bragg gratings in a sensing optical fiber comprise: (1) a source laser; (2) an optical detector configured to detect a reflected signal from the sensing optical fiber; (3) a plurality of frequency generators configured to generate a signal having a frequency corresponding to an interferometer frequency of a different one of the plurality of Bragg gratings; (4) a plurality of demodulation elements, each demodulation element configured to combine the signal produced by a different one of the plurality of frequency generators with the detected signal from the sensing optical fiber; (5) a plurality of peak detectors, each peak detector configured to detect a peak of the combined signal from a different one of the demodulation elements; and (6) a laser wavenumber detection element configured to determine a wavenumber of the laser when any of the peak detectors detects a peak.

Moore, Jason P.↗

Thermal Signature Identification System (TheSIS)

We characterize both nonlinear and high order linear responses of fiber-optic and optoelectronic components using spread spectrum temperature cycling methods. This Thermal Signature Identification System (TheSIS) provides much more detail than conventional narrowband or quasi-static temperature profiling methods. This detail allows us to match components more thoroughly, detect subtle reversible shifts in performance, and investigate the cause of instabilities or irreversible changes. In particular, we create parameterized models of athermal fiber Bragg gratings (FBGs), delay line interferometers (DLIs), and distributed feedback (DFB) lasers, then subject the alternative models to selection via the Akaike Information Criterion (AIC). Detailed pairing of components, e.g. FBGs, is accomplished by means of weighted distance metrics or norms, rather than on the basis of a single parameter, such as center wavelength.

Laser↗

A GridFTP transport driver for Globus XIO.

GridFTP is a high-performance, reliable data transfer protocol optimized for high-bandwidth wide-area networks. Based on the Internet FTP protocol, it defines extensions for high-performance operation and security. The Globus implementation of GridFTP provides a modular and extensible data transfer system architecture suitable for wide area and high-performance environments. GridFTP is the de facto standard in projects requiring secure, robust, high-speed bulk data transport. For example, the high energy physics community is basing its entire tiered data movement infrastructure for the Large Hadron Collider computing Grid on GridFTP; the Laser Interferometer Gravitational Wave Observatory routinely uses GridFTP to move 1 TB a day during production runs; and GridFTP is the recommended data transfer mechanism to maximize data transfer rates on the TeraGrid. Commonly used GridFTP clients include globus-url-copy, uberftp, and the Globus Reliable File Transfer service. In this paper, we present a Globus XIO based client to GridFTP that provides a simple Open/Close/Read/Write (OCRW) interface to the users. Such a client greatly eases the addition of GridFTP support to third-party programs, such as SRB and MPICH-G2. Further, this client provides an easier and familiar interface for applications to efficiently access remote files. We compare the performance of this client with that of globus-url-copy on multiple endpoints in the TeraGrid infrastructure. We perform both memory-to-memory and disk-to-disk transfers and show that the performance of this OCRW client is comparable to that of globus-url-copy. We also show that our GridFTP client significantly outperforms the GPFS WAN on the TeraGrid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time domain simulations of arm locking in LISA

Arm locking is a proposed laser frequency stabilization technique for the Laser Interferometer Space Antenna (LISA), a gravitational-wave observatory sensitive in the milliHertz frequency band. Arm locking takes advantage of the geometric stability of the triangular constellation of three spacecraft that compose LISA to provide a frequency reference with a stability in the LISA measurement band that exceeds that available from a standard reference such as an optical cavity or molecular absorption line. We have implemented a time-domain simulation of a Kalman-filter-based arm-locking system that includes the expected limiting noise sources as well as the effects of imperfect a priori knowledge of the constellation geometry on which the design is based. We use the simulation to study aspects of the system performance that are difficult to capture in a steady-state frequency-domain analysis such as frequency pulling of the master laser due to errors in estimates of heterodyne frequency. We find that our implementation meets requirements on both the noise and dynamic range of the laser frequency with acceptable tolerances and that the design is sufficiently insensitive to errors in the estimated constellation geometry that the required performance can be maintained for the longest continuous measurement intervals expected for the LISA mission.

79 ASTRONOMY AND ASTROPHYSICS↗

A compact fiber optics-based heterodyne combined normal and transverse displacement interferometer

While Photonic Doppler Velocimetry (PDV) has become a common diagnostic tool for the measurement of normal component of particle motion in shock wave experiments, this technique has not yet been modified for the measurement of combined normal and transverse motion, as needed in oblique plate impact experiments. In this study, we discuss the design and implementation of a compact fiber-optics-based heterodyne combined normal and transverse displacement interferometer. Like the standard PDV, this diagnostic tool is assembled using commercially available telecommunications hardware and uses a 1550 nm wavelength 2 W fiber-coupled laser, an optical focuser, and single mode fibers to transport light to and from the target. Two additional optical probes capture first-order beams diffracted from a reflective grating at the target free-surface and deliver the beams past circulators and a coupler where the signal is combined to form a beat frequency. The combined signal is then digitized and analyzed to determine the transverse component of the particle motion. The maximum normal velocity that can be measured by this system is limited by the equivalent transmission bandwidth (3.795 GHz) of the combined detector, amplifier, and digitizer and is estimated to be ~2.9 km/s. Finally, sample symmetric oblique plate-impact experiments are performed to demonstrate the capability of this diagnostic tool in the measurement of the combined normal and transverse displacement particle motion.

47 OTHER INSTRUMENTATION↗

RESOLVED DEPLETION ZONES AND SPATIAL DIFFERENTIATION OF N{sub 2}H{sup +} AND N{sub 2}D{sup +}

We present a study on the spatial distribution of N{sub 2}D{sup +} and N{sub 2}H{sup +} in 13 protostellar systems. Eight of thirteen objects observed with the IRAM 30 m telescope show relative offsets between the peak N{sub 2}D{sup +} (J = 2 {yields} 1) and N{sub 2}H{sup +} (J = 1 {yields} 0) emission. We highlight the case of L1157 using interferometric observations from the Submillimeter Array and Plateau de Bure Interferometer of the N{sub 2}D{sup +} (J = 3 {yields} 2) and N{sub 2}H{sup +} (J = 1 {yields} 0) transitions, respectively. Depletion of N{sub 2}D{sup +} in L1157 is clearly observed inside a radius of {approx}2000 AU (7'') and the N{sub 2}H{sup +} emission is resolved into two peaks at radii of {approx}1000 AU (3.''5), inside the depletion region of N{sub 2}D{sup +}. Chemical models predict a depletion zone in N{sub 2}D{sup +} and N{sub 2}H{sup +} due to destruction of H{sub 2}D{sup +} at T {approx} 20 K and the evaporation of CO off dust grains at the same temperature. However, the abundance offsets of 1000 AU between the two species are not reproduced by chemical models, including a model that follows the infall of the protostellar envelope. The average abundance ratios of N{sub 2}D{sup +} to N{sub 2}H{sup +} have been shown to decrease as protostars evolve by Emprechtinger et al., but this is the first time depletion zones of N{sub 2}D{sup +} have been spatially resolved. We suggest that the difference in depletion zone radii for N{sub 2}H{sup +} and N{sub 2}D{sup +} is caused by either the CO evaporation temperature being above 20 K or an H{sub 2} ortho-to-para ratio gradient in the inner envelope.

79 ASTRONOMY AND ASTROPHYSICS↗