Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Optical Signal Processing: Poisson Image Restoration and Shearing Interferometry

Optical signal processing can be performed in either digital or analog systems. Digital computers and coherent optical systems are discussed as they are used in optical signal processing. Topics include: image restoration; phase-object visualization; image contrast reversal; optical computation; image multiplexing; and fabrication of spatial filters. Digital optical data processing deals with restoration of images degraded by signal-dependent noise. When the input data of an image restoration system are the numbers of photoelectrons received from various areas of a photosensitive surface, the data are Poisson distributed with mean values proportional to the illuminance of the incoherently radiating object and background light. Optical signal processing using coherent optical systems is also discussed. Following a brief review of the pertinent details of Ronchi's diffraction grating interferometer, moire effect, carrier-frequency photography, and achromatic holography, two new shearing interferometers based on them are presented. Both interferometers can produce variable shear.

Hong, Yie-Ming↗

Doppler shift system

A system is described for measuring velocities of radiating particles based on Doppler shift. Light from the particles is directed through a narrow band optical filter to a Fabry-Perot interferometer initially tuned to a selected center line corresponding to zero particle Doppler shift. The movable mirror of the interferometer is made to sweep about the center line by the output of a modulation oscillator. The fringe pattern output is imaged onto a pin hole through which light is directed to a photomultiplier. The output of the photomultiplier is supplied to a phase sensitive detector with the oscillator output as a reference signal and which operates in the quadrature mode. The detector's output is gain controlled and is combined with the oscillator's output to adjust the interferometer's movable mirror to acquire the line center.

Aisenberg, S.↗

Very Long Baseline Interferometry (VLBI) earth physics

The characteristics of the Michelson/Pease stellar interferometer are discussed. An analog of the interferometer using radio waves is described. The use of a conventional hard-wired interferometer with very long base line interferometry (VLBI) is analyzed. Mathematical models are developed to analyze the VLBI techniques. A summary of VLBI geodetic experiments is tabulated. The concept and application of the astronomical radio interferometric earth surveys (ARIES) are reported. A schematic diagram of ARIES implementation is provided.

Macdoran, P. F.↗

Research in millimeter wave techniques

During the past six months, efforts on this project have been devoted to: (1) continuation of construction and testing of a 6 GHz subharmonic mixer model with extension of the pumping frequency of this mixer to omega sub s/4, (2) construction of a 183 GHz subharmonic mixer based on the results of tests on this 6 GHz model, (3) ground-based radiometric measurements at 183 GHz, (4) fabrication and testing of wire grid interferometers, (5) calculations of reflected and lost power in these interferometers, and (6) calculations of the antenna temperature due to water vapor to be expected in down-looking radiometry as a function of frequency. Significant events during the past six months include: (1) Receipt of a 183 GHz single-ended fundamental mixer, (2) attainment of 6 db single sideband conversion loss with the 6 GHz subharmonic mixer model by using a 1.5 GHz (omega sub s/4) pump frequency, (3) additional ground-based radiometric measurements and (4) derivation of equations for reflection and loss for wire grid interferometers.

Mcmillan, R. W.↗

A high declination search at 8 GHz for compact radio sources

With the Haystack-NRAO interferometer (baseline length of 20 million wavelengths at 3.8 cm) 37 sources were observed whose declinations were above 50 deg. Seven of these sources have compact cores with diameters smaller than 5 milliarcsec and with correlated flux densities greater than about 0.5 Jy; the remaining sources have no cores with flux densities above about 0.3 Jy, the sensitivity limit of the interferometer. Two of the sources with detected compact cores, 4C 67.05 and 3C 418, were also observed with longer-baseline interferometers; the diameter of the core of 4C 67.05 was estimated to be smaller than 1 milliarcsec and that of 3C 418 to be smaller than 0.4 milliarcsec. All diameter estimates were based on an assumed circular Gaussian distribution of radio brightness and refer to the contour with brightness density e to the -1/2 power times that of the center. Positions for the detected sources were also obtained from the interferometric data, the uncertainty in these coordinate estimates ranging from 0.04 to 0.6 arcsec. The compact core detected in 3C 390.3 was found to lie near the center of this extended (approximately 4 arcmin in diameter) double radio source and to be coincident to within 1 arcsec with an N galaxy previously identified with 3C 390.3.

Wittels, J. J.↗

Astronomical monochromatic imaging as applied to the Io sodium cloud

Four types of instruments for recording monochromatic astronomical images are compared: filters; slitless spectrographs; multislit spectrographs; and interferometers. Each of these instruments has been used on the sodium emission cloud of Io, with varying degrees of success. Multislit spectrographs and interferometers encode the signal, and it can be extracted with a noise level close to that for photon statistics. This is not normally the case for filters and slitless spectrographs. On balance, it is found that a Mach-Zehnder interferometer provides the best system for imaging faint monochromatic signals on a brighter continuum background.

Murcray, F. J.↗

Fine structure and time variation of the quiet sun at 1.3 cm

The Hat Creek two-element interferometer has been used to study the quiet sun at 22 GHz. A statistical analysis of output of the interferometer clearly shows the existence of time variations on the quiet sun with time scales of approximately 180 s. The observations suggest that the fine structure on the quiet sun might consist of two components - one which varies with the time scales of approximately 3 min and the other being relatively stable. The average visibility amplitude indicates that the fine structure on the sun has a typical angular size of approximately 6 sec. The observation that the variance and the mean of the visibility amplitudes depend in the same way on the projected baseline suggests that the transient sources have angular size similar to the average size of the fine structure on the quiet sun. Power spectra of the output of the interferometer show no significant periodicity.

Rao, A. P.↗

On the limitations of the concept of space frequency equivalence

A narrow-band correlation interferometer using directive (large) antennas is equivalent to a wideband correlation interferometer employing isotropic (small) antennas. This concept of space frequency equivalence, due to Kock and Stone, is reexamined and is shown to hold exactly only for the mean or expected values of the correlation interferometer outputs. If their variances are considered, the equivalence disappears, with the variance fo the wideband system always equal to or greater than that of the narrow-band system.

Macphie, R. H.↗

Thermal expansion of graphite-epoxy between 116 K and 366 K

A Priest laser interferometer was developed to measure the thermal strain of composite laminates. The salient features of this interferometer are that: (1) it operates between 116 K and 366 K; (2) it is easy to operate; (3) minimum specimen preparation is required; (4) coefficients of thermal expansion in the range of 0-5 micro epsilon/K can be measured; and (5) the resolution of thermal strain is on the order of micro epsilon. The thermal response of quasi-isotropic, T300/5208, grahite-epoxy composite material was studied with this interferometer. The study showed that: (1) for the material tested, thermal cycling effects are negligible; (2) variability of thermal response from specimen to specimen may become significant at cryogenic temperatures; and (3) the thermal response of 0.6 cm and 2.5 cm wide specimens are the same above room temperature.

Short, J. S.↗

Fiber optic sensors

A survey of the developments in the field of fiber optics sensor technology is presented along with a discussion of the advantages of optical measuring instruments as compared with electronic sensors. The two primary types of fiber optics sensors, specifically those with multiwave fibers and those with monowave fibers, are described. Examples of each major sensor type are presented and discussed. Multiwave detectors include external and internal fiber optics sensors. Among the monowave detectors are Mach-Zender interferometers, Michelson interferometers, Sagnac interferometers (optical gyroscopes), waveguide resonators, and polarimeter sensors. Integrated optical sensors and their application in spectroscopy are briefly discussed.

Hesse, J.↗

Multipath induced errors in meteorological Doppler/interferometer location systems

One application of an RF interferometer aboard a low-orbiting spacecraft to determine the location of ground-based transmitters is in tracking high-altitude balloons for meteorological studies. A source of error in this application is reflection of the signal from the sea surface. Through propagating and signal analysis, the magnitude of the reflection-induced error in both Doppler frequency measurements and interferometer phase measurements was estimated. The theory of diffuse scattering from random surfaces was applied to obtain the power spectral density of the reflected signal. The processing of the combined direct and reflected signals was then analyzed to find the statistics of the measurement error. It was found that the error varies greatly during the satellite overpass and attains its maximum value at closest approach. The maximum values of interferometer phase error and Doppler frequency error found for the system configuration considered were comparable to thermal noise-induced error.

Wallace, R. G.↗

Special topics in infrared interferometry

Topics in IR interferometry related to the development of a Michelson interferometer are treated. The selection and reading of the signal from the detector to the analog to digital converter is explained. The requirements for the Michelson interferometer advance speed are deduced. The effects of intensity modulation on the interferogram are discussed. Wavelength and intensity calibration of the interferometer are explained. Noise sources (Nyquist or Johnson noise, phonon noise), definitions of measuring methods of noise, and noise measurements are presented.

Hanel, R. A.↗

Determination of atmospheric backscatter at 10.6 microns

Profiles have been obtained for atmospheric aerosol backscatter coefficient versus altitude at four different geographical locations, by means of a 10.6-micron lidar that uses a CO2 laser. A Mach-Zehnder interferometer is used to separate the laser output beam into a measurement beam and a reference beam. The interferometer combines the reference beam with backscattered radiation collected by a telescope, and the combined beams are focused onto a cooled HgCdTe photodiode at the interferometer exit. Attention is given to the results of a backscatter study experiment flown aboard a NASA research aircraft.

Jones, W. D.↗

Are young stars always associated with cold massive disks? A CO and millimeter interferometric continuum survey

The results of a combined millimeter-spectral-line and continuum survey of cold far-infrared sources selected to favor embedded young stars in the Galaxy are presented. The spectral-line observations were performed with the 5 meter antenna of the University of Texas Millimeter-Wave Observatory. High resolution continuum observations were obtained with the Owens Valley (OVRO) Millimeter-Wave Interferometer. The goal of the survey was to gain insight into the mass, temperature, and distribution of cold dust which envelopes stars during the earliest stages of their evolution. The first phase of our survey involved 1.2 arcmin resolution observations of CO-12 and CO-13 emission lines toward each source. All but two sources had detectable CO emission. We found that 40% of the sources appear to be associated with star formation as evidenced by the presence of enhanced CO-12 line widths or broad wings. At least five of these objects are associated with bipolar molecular outflows. The second phase of our survey involves high resolution 2.7 mm continuum observations with 3 interferometer baselines ranging from 15 to 55 m in length. Preliminary results indicate that about 25% of the sources in our sample have detectable continuum emission on scales less than 30 arcsec. The high percentage of sources with enhanced CO-12 line widths or broad wings indicates that a significant fraction of our samples, 40%, are likely to be young stars. The lower detection percentage in the continuum observations, 25%, suggest that such objects are not always surrounded by large concentrations of gas and dust. The continuum detection percentage for actual dust emission could be lower than that given above since emission from ionized gas could be responsible for the observed 2.7 mm emission in some objects. To get an understanding of the type of object detected in our survey, a map of one of the survey sources, L1689N, has been made using the OVRO mm interferometer.

Mundy, L. G.↗

Speckle interferometry using fiber optic phase stepping

A system employing closed-loop phase-stepping is used to measure the out-of-plane deformation of a diffusely reflecting object. Optical fibers are used to provide reference and object beam illumination for a standard two-beam speckle interferometer, providing set-up flexibility and ease of alignment. Piezoelectric fiber-stretchers and a phase-measurement/servo system are used to provide highly accurate phase steps. Intensity data is captured with a charge-injection-device camera, and is converted into a phase map using a desktop computer. The closed-loop phase-stepping system provides 90 deg phase steps which are accurate to 0.02 deg, greatly improving this system relative to open-loop interferometers. The system is demonstrated on a speckle interferometer, measuring the rigid-body translation of a diffusely reflecting object with an accuracy + or - 10 deg, or roughly + or - 15 nanometers. This accuracy is achieved without the use of a pneumatically mounted optics table.

Mercer, Carolyn R.↗

A laser spectrometer and wavemeter for pulsed lasers

The design, construction, calibration, and evaluation of a pulsed laser wavemeter and spectral analyzer are described. This instrument, called the Laserscope for its oscilloscope-like display of laser spectral structure, was delivered to NASA Langley Research Center as a prototype of a laboratory instrument. The key component is a multibeam Fizeau wedge interferometer, providing high (0.2 pm) spectral resolution and a linear dispersion of spectral information, ideally suited to linear array photodiode detectors. Even operating alone, with the classic order-number ambiguity of interferometers unresolved, this optical element will provide a fast, real-time display of the spectral structure of a laser output. If precise wavelength information is also desired then additional stages must be provided to obtain a wavelength measurement within the order-number uncertainty, i.e., within the free spectral range of the Fizeau wedge interferometer. A Snyder (single-beam Fizeau) wedge is included to provide this initial wavelength measurement. Difficulties in achieving the required wide-spectrum calibration limit the usefulness of this function.

Mckay, J. A.↗

High resolution solar spectrometer system for measuring atmospheric constituents

A mid-IR Michelson interferometer capable of obtaining 0.002/cm resolution solar spectra has been developed for balloon use. The interferometer is based on the Bomem self-aligning instrument, and is equipped with a solar tracking system, telemetry, and recording systems, as well as temperature control and gondola orientation. The interferometer has made two successful flights in the 7-14-micron interval up to 40 km. The basic systems are described and sample spectra are presented.

Murcray, Frank J.↗