Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Conduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Studies of solar flares using optical, X-ray and radio data

X-ray, radio, H-alpha, and 3835-A data for a number of solar flares identified as sources of X-ray bursts are compared and analyzed. Eight of the more distinctive flares are described in detail, the exact value of H-alpha intensity is determined, and the production of the H-alpha emission is considered. It is shown that: (1) there is a good correspondence between the rise and peak of H-alpha emission and hard X-ray flux; (2) the H-alpha surface brightness of hard and soft X-ray bursts is the same for flares of the same soft X-ray flux; (3) all multiple spikes correspond to different steps in optical flares development; (4) smaller flares produce no observed brightening; (5) there is evidence that the low chromospheric network is not heated by conduction from above; and (6) the flare H-alpha emission can be explained by direct excitation of a preflare cloud or prominence by the flare electrons and their secondaries.

Zirin, H.↗

Design, fabrication and test of a hydrogen heat pipe

Re-entrant groove technology was extended to hydrogen heat pipes. Parametric analyses are presented which optimize the theoretical design while considering the limitations of state-of-the-art extrusion technology. The 6063-T6 aluminum extrusion is 14.6 mm OD with a wall thickness of 1.66 mm and contains 20 axial grooves which surround a central 9.3 mm diameter vapor core. Each axial groove is 0.775 mm diameter with a 0.33 mm opening. An excess vapor reservoir is provided at the evaporator to minimize the pressure containment hazard during ambient storage. Modifications to the basic re-entrant groove profile resulted in improved overall performance. While the maximum heat transport capacity decreased slightly to 103 w-m the static wicking height increased markedly to 4.5 cm. The heat pipe became operational between 20 and 30 K after a cooldown from 77 K without any difficulty. Steady state performance data taken over a 19 to 23 K temperature range indicated: (1) maximum heat transport capacity of 5.4 w-m; (2) static wicking height of 1.42 cm; and (3) overall heat pipe conductance of 1.7 watts/deg C.

Alario, J.↗

On the internal structure of the major satellites of the outer planets

The structures and thermal evolutions of the large icy-satellites of the outer solar system are considered. It is shown (for bodies comparable in size and mass to the Galilean satellites, having sizeable mass fraction of H2O, and with meteoritic abundances of radioactive materials contained within their silicate fractions) that the crust of solid ice over a liquid mantle predicted by conductive heat-transfer calculations is unstable to large-scale solid-state convection. For appropriate material parameters, convective heat-transfer rates are sufficient to freeze a large liquid mantle on a time scale that is short compared to the lifetime of the body. It is also concluded that the ice layer is convecting at the present time. A reevaluation of previous work, using improved values for material parameters and boundary conditions, reverses earlier conclusions and implies a rigid outer crust with resulting long-term stability of surface features to creep deformation. The combination of a rigid crust with active internal convection presents the additional possibility of surface features that are produced and maintained by dynamic internal processes.

Reynolds, R. T.↗

Improved Thermal-Diffusivity-Measuring Apparatus

Accuracy at high temperature improved. Furnace heats specimen to experimental temperature, and flash tube raises specimen temperature by small amount and for short time so diffusivity (composite property of heat capacity and conductivity) determined. Specimen mount ensures minimum heat loss during temperature-rise measurement. Measurement temperatures up to 1,000 degrees C realized with fused-quartz light pipe and up to 1,600 degrees C with sapphire light pipe.

Wood, C.↗

A Model of the Soft X-ray Background as a Blast Wave Viewed from Inside

The suggestion that the soft X-ray background arises in part from the Sun which is inside a large supernova blastwave was examined by models of spherical blastwaves. The models can produce quantitative fits to both surface brightnesses and energy band ratios when t = 10 to the 5th power E sub o = 5 x 10 to the 50th power ergs, and n sub approx. 0.004 cm to the -3 power. The models are generalized by varying the relative importance of factors such as thermal conduction, Coulomb heating of electrons, and external pressure; and to allow the explosions to occur in preexisting cavities with steep density gradients, or by examination of the effects of large obstructions or other anisotrophies in the ambient medium.

Edgar, R. J.↗

Characterization-curing-property studies of HBRF 55A resin formulations

Characterization curing property investigations on HBRF 55A resin formulations are reported. The initial studies on as received cured samples cut from a full-size FWC are reviewed. Inadequacies of as-received and aged samples are pointed out and additional electron microscopic evidence is offered. Characterization of as-received ingredients of HBRF 55A formulation is described. Specifically, Epon 826, Epon 828, EpiRez 5022, RD-2 and various amines, including Tonox and Tonox 60.40, were characterized. Cure kinetics of various formulations are investigated. Changes in physical/thermal properties (viscosity, specific heat, thermal conductivity and density) during cure are described.

Pearce, E. M.↗

Ball-and-Socket Mount for Instruments

Jaws engage instrument precisely but release it readily. Mounting mechanism holds scientific instrument securely, allows instrument to be oriented, and minimizes conduction of heat to and from instrument. Mechanism also allows quick replacement of instrument.

Kaelber, E.↗

Thermal-capillary analysis of small-scale floating zones Steady-state calculations

Galerkin finite element analysis of a thermal-capillary model of the floating zone crystal growth process is used to predict the dependence of molten zone shape on operating conditions for the growth of small silicon boules. The model accounts for conduction-dominated heat transport in the melt, feed rod and growing crystal and for radiation between these phases, the ambient and a heater. Surface tension acting on the shape of the melt/gas meniscus counteracts gravity to set the shape of the molten zone. The maximum diameter of the growing crystal is set by the dewetting of the melt from the feed rod when the crystal radius is large. Calculations with small Bond number show the increased zone lengths possible for growth in a microgravity environment. The sensitivity of the method to the shape and intensity of the applied heating distribution is demonstrated. The calculations are compared with experimental observations.

Duranceau, J. L.↗

Characterization of NTD germanium and ion-implanted Si bolometers at 0.3K and 0.1K

Bolometer elements were built and tested using NTD germanium and ion-implanted Si thermometer elements. The thermal links were made using aluminum wires and NbC(x)N(y) coated carbon fibers. The temperature dependence of the detector resistance, lead thermal conductivity, and heat capacity were measured. The dependence of the detector resistance on applied electric field was also measured. This, combined with the current-voltage curve for the detector, allowed the calculation of the detector responsivity. Known amounts of energy were deposited into the detector by allowing X-rays from the decay of Fe-55 to be thermalized in the detector. In the best-measured case, the predicted pulse height/measured height was 1.04 + or - .05. The noise at frequencies above 25 Hz in the NTD Ge was near that predicted by thermodynamics. The noise below 25 Hz has a 1/f character and may be in the carbon fiber/bolometer junction. The implanted detectors show some 1/f noise which depends on the total thermometer volume. Comparison between noise measurements and theory will be presented.

Moseley, H.↗

Discrimination of soil hydraulic properties by combined thermal infrared and microwave remote sensing

Using the De Vries models for thermal conductivity and heat capacity, thermal inertia was determined as a function of soil moisture for 12 classes of soil types ranging from sand to clay. A coupled heat and moisture balance model was used to describe the thermal behavior of the top soil, while microwave remote sensing was used to estimate the soil moisture content of the same top soil. Soil hydraulic parameters are found to be very highly correlated with the combination of soil moisture content and thermal inertia at the same moisture content. Therefore, a remotely sensed estimate of the thermal behavior of the soil from diurnal soil temperature observations and an independent remotely sensed estimate of soil moisture content gives the possibility of estimating soil hydraulic properties by remote sensing.

Vandegriend, A. A.↗

A 1987 overview of free-piston Stirling technology for space power application

An overview is presented of the NASA Lewis Research Center free-piston Stirling engine activities directed toward space-power application. NASA Lewis serves as the project office to manage the newly initiated NASA SP-100 Advanced Technology Program. One of the major elements of this five-year program is the development of advanced power conversion concepts of which the Stirling cycle is a viable growth candidate. Under this program the status of the 25 kWe opposed-piston Space Power Demonstrator Engine (SPDE) is presented. Included in the SPDE discussion are comparisons between predicted and experimental engine performance, enhanced performance resulting from regenerator modification, increased operating stroke brought about by isolating the gas bearing flow between the displacer and power piston, identifying excessive energy losses and recommending corrective action, and a better understanding of linear alternator design and operation. Technology work is also conducted on heat exchanger concepts, both design and fabrication. Design parameters and conceptual design features are also presented for a 25 kWe, single-cylinder free-piston Stirling space-power converter.

Slaby, Jack G.↗

Regenerative fuel cell study for satellites in GEO orbit

Summarized are the results of a 12-month study to identify high performance regenerative hydrogen-oxygen fuel cell concepts for geosynchronous satellite application. Emphasis was placed on concepts with the potential for high energy density (W-hr/lb) and passive means for water and heat management to maximize system reliability. Both polymer membrane and alkaline electrolyte fuel cells were considered, with emphasis on the alkaline cell because of its high performance, advanced state of development, and proven ability to operate in a launch and space environment. Three alkaline system concepts were studied. The first, the integrated design, utilized a configuration in which the fuel cell and electrolysis cells are alternately stacked inside a pressure vessel. Product water is transferred by diffusion during electrolysis and waste heat is conducted through the pressure wall, thus using completely passive means for transfer and control. The second alkaline system, the dedicated design, uses a separate fuel cell and electrolysis stack so that each unit can be optimized in size and weight based on its orbital operating period. The third design was a dual function stack configuration, in which each cell can operate in both fuel cell and electrolysis mode, thus eliminating the need for two separate stacks and associated equipment. Results indicate that using near term technology energy densities between 46 and 52 W-hr/lb can be achieved at efficiencies of 55 percent. System densities of 115 W-hr/lb are contemplated.

Levy, Alexander↗

Analytical modeling of helium II in forced flow conditions

A numerical model was developed to examine the flow behavior of He II under forced flow conditions. The model basically solves the governing equations in the two-fluid model of He II, and can be used to assess the pump requirement for transferring He II in spaceborne systems. Predictions of liquid temperature and pressure drop agree well with empirical data obtained from small scale tests. At high transfer rates, the model predicts that the forced convection dominates the Gorter-Mellink conduction in heat transfer, and the classical turbulent flow correlation is sufficient for calculating the pressure drop across the transfer line.

Ng, Y. S.↗

A nonlinear filtering process diagnostic system for the Space Station

A nonlinear filtering process diagnostic system, terrestrial simulation and real time implementation studies is presented. Possible applications to Space Station subsystem elements are discussed. A process diagnostic system using model based nonlinear filtering for systems with random structure was shown to provide improvements in stability, robustness, and overall performance in comparison to linear filter based systems. A suboptimal version of the nonlinear filter (zero order approximation filter, or ZOA filter) was used in simulation studies, initially, with a pressurized water reactor model and then with water/steam heat exchanger models. Finally, a real time implementation for leak detection in a water/steam heat exchanger was conducted using the ZOA filter and heat exchanger models.

Yoel, Raymond R.↗

Dielectric composites incorporating enthalpy stabilization for NbTi windings

Composites of ceramic powders in epoxies appropriate for both insulating and impregnating NbTi windings are studied. Specific heat, thermal conductivity, thermal contraction, and magnetocaloric measurements on composites are presented. Thermal contractions well matched to copper are found and thermal shock resistance is greatly enhanced. Enthalpies, 4.2-6 K, range up to 80 mJ/cu cm and are 20-50 times larger than that of the pure epoxies. Results are not specific to the epoxies used but apply to composites with any amorphous matrices.

Lawless, W. N.↗

Pressurized-Flat-Interface Heat Exchanger

High thermal conductance obtained without leakage between loops. Heat-exchanger interface enables efficient transfer of heat between two working fluids without allowing fluids to intermingle. Interface thin, flat, and easy to integrate into thermal system. Possible application in chemical or pharmaceutical manufacturing when even trace contamination of process stream with water or other coolant ruins product. Reduces costs when highly corrosive fluids must be cooled or heated.

Voss, F. E.↗

Swept shock/boundary layer interaction experiments in support of CFD code validation

Research on the topic of shock wave/turbulent boundary layer interaction was carried out. Skin friction and surface pressure measurements in fin-induced, swept interactions were conducted, and heat transfer measurements in the same flows are planned. The skin friction data for a strong interaction case (Mach 4, fin-angles equal 16 and 20 degrees) were obtained, and their comparison with computational results was published. Surface pressure data for weak-to-strong fin interactions were also obtained.

Settles, G. S.↗