Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

GEO2D - Two-Dimensional Computer Model of a Ground Source Heat Pump System

This file contains a zipped file that contains many files required to run GEO2D. GEO2D is a computer code for simulating ground source heat pump (GSHP) systems in two-dimensions. GEO2D performs a detailed finite difference simulation of the heat transfer occurring within the working fluid, the tube wall, the grout, and the ground. Both horizontal and vertical wells can be simulated with this program, but it should be noted that the vertical wall is modeled as a single tube. This program also models the heat pump in conjunction with the heat transfer occurring. GEO2D simulates the heat pump and ground loop as a system. Many results are produced by GEO2D as a function of time and position, such as heat transfer rates, temperatures and heat pump performance. On top of this information from an economic comparison between the geothermal system simulated and a comparable air heat pump systems or a comparable gas, oil or propane heating systems with a vapor compression air conditioner. The version of GEO2D in the attached file has been coupled to the DOE heating and cooling load software called ENERGYPLUS. This is a great convenience for the user because heating and cooling loads are an input to GEO2D. GEO2D is a user friendly program that uses a graphical user interface for inputs and outputs. These make entering data simple and they produce many plotted results that are easy to understand. In order to run GEO2D access to MATLAB is required. If this program is not available on your computer you can download the program MCRInstaller.exe, the 64 bit version, from the MATLAB website or from the Geothermal Data Repository. This is a free download which will enable you to run GEO2D.

15 GEOTHERMAL ENERGY↗

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of self-heating of thermally assisted spin-transfer torque magnetic random access memory

Thermal assistance has been shown to significantly reduce the required operation power for spin torque transfer magnetic random access memory (STT-MRAM). Proposed heating methods include modified material stack compositions that result in increased self-heating or external heat sources. Here, we analyze the self-heating process of a standard perpendicular magnetic anisotropy STT-MRAM device through numerical simulations in order to understand the relative contributions of Joule, thermoelectric Peltier and Thomson, and tunneling junction heating. A 2D rotationally symmetric numerical model is used to solve the coupled electro-thermal equations including thermoelectric effects and heat absorbed or released at the tunneling junction. We compare self-heating for different common passivation materials, positive and negative electrical current polarity, and different device thermal anchoring and boundaries resistance configurations. The variations considered are found to result in significant differences in maximum temperatures reached. Average increases of 3 K, 10 K, and 100 K for different passivation materials, positive and negative polarity, and different thermal anchoring configurations, respectively, are observed. Furthermore, the highest temperatures, up to 424 K, are obtained for silicon dioxide as the passivation material, positive polarity, and low thermal anchoring with thermal boundary resistance configurations. Interestingly it is also found that due to the tunneling heat, Peltier effect, device geometry, and numerous interfacial layers around the magnetic tunnel junction (MTJ), most of the heat is dissipated on the lower potential side of the magnetic junction. We have observed this asymmetry in heating and is important as thermally assisted switching requires heating of the free layer specifically and this will be significantly different for the two polarity operations, set and reset.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

HOW AGN JETS HEAT THE INTRACLUSTER MEDIUM—INSIGHTS FROM HYDRODYNAMIC SIMULATIONS

Feedback from active galactic nuclei (AGNs) is believed to prevent catastrophic cooling in galaxy clusters. However, how the feedback energy is transformed into heat, and how the AGN jets heat the intracluster medium (ICM) isotropically, still remain elusive. In this work, we gain insights into the relative importance of different heating mechanisms using three-dimensional hydrodynamic simulations including cold gas accretion and momentum-driven jet feedback, which are the most successful models to date in terms of reproducing the properties of cool cores. We find that there is net heating within two “jet cones” (within ∼30° from the axis of jet precession) where the ICM gains entropy by shock heating and mixing with the hot thermal gas within bubbles. Outside the jet cones, the ambient gas is heated by weak shocks, but not enough to overcome radiative cooling, therefore, forming a “reduced” cooling flow. Consequently, the cluster core is in a process of “gentle circulation” over billions of years. Within the jet cones, there is significant adiabatic cooling as the gas is uplifted by buoyantly rising bubbles; outside the cones, energy is supplied by the inflow of already-heated gas from the jet cones as well as adiabatic compression as the gas moves toward the center. In other words, the fluid dynamics self-adjusts such that it compensates and transports the heat provided by the AGN, and hence no fine-tuning of the heating profile of any process is necessary. Throughout the cluster evolution, turbulent energy is only at the percent level compared to gas thermal energy, and thus turbulent heating is not the main source of heating in our simulation.

79 ASTRONOMY AND ASTROPHYSICS↗

Compressor Selection and Equipment Sizing for Cold Climate Heat Pumps

In order to limit heating capacity degradation at -25 C (-13 F) ambient to 25%, compared to the nominal rating point capacity at 8.3 C (47 F), an extensive array of design and sizing options were investigated, based on fundamental equipment system modeling and building energy simulation. Sixteen equipment design options were evaluated in one commercial building and one residential building, respectively in seven cities. The energy simulation results were compared to three baseline cases: 100% electric resistance heating, a 9.6 HSPF single-speed heat pump unit, and 90% AFUE gas heating system. The general recommendation is that variable-speed compressors and tandem compressors, sized such that their rated heating capacity at a low speed matching the building design cooling load, are able to achieve the capacity goal at low ambient temperatures by over-speeding, for example, a home with a 3.0 ton design cooling load, a tandem heat pump could meet this cooling load running a single compressor, while running both compressors to meet heating load at low ambient temperatures in a cold climate. Energy savings and electric resistance heat reductions vary with building types, energy codes and climate zones. Oversizing a heat pump can result in larger energy saving in a less energy efficient building and colder regions due to reducing electric resistance heating. However, in a more energy-efficient building or for buildings in warmer climates, one has to consider balance between reduction of resistance heat and addition of cyclic loss.

Building Energy Simulation↗

Numerical Analysis of Novel Plate Type Heat Exchanger with Oval-Twisted Channels

The novel heat exchanger (HX) designs implementing geometrical and surface modification combinations are expected to perform better than traditional HX technologies. Applied enhancement techniques seek to achieve (1) higher overall heat transfer performance, (2) increased compactness, and (3) simplified or comparable manufacturability. One innovative enhancement technique is to generate swirling flow vortices induced by channel or tube twisting. The turbulence generated by the twisted cross-section greatly enhances the heat transfer rate with minimal increases in pressure drop. Plate-type HXs and Printed Circuit Heat Exchangers (PCHXs) are compact designs that achieve high heat transfer rates per unit volume by utilizing several small channels, which maximizes the heat transfer surface area between the hot and cold fluids. Currently, advanced manufacturing technologies enable the design and fabrication of compact-type units with complicated channel geometries to achieve the highest performance and meet the compactness criteria of innovative HX technology. The proposed HX design concept combines the compactness of plate-type HXs and twisted channels, which provide additional turbulence and flow swirl enhancement. The plate-type oval-twisted HX (PTOTHX) is a crossflow configuration, with 16 short channels on one side (for hot fluid) and 8 long channels on the perpendicular side (for cold fluid). The inlet plenums have flow guide vanes to redirect flow and produce uniformity across the various flow paths. The compact size and purportedly improved heat transfer performance of the PTOTHX investigated herein prove its viability in various applications. Some notable potential nuclear applications of the PTOTHX include reactor core, spent fuel cooling, and residual heat dissipation. To establish a reference case, circular channels (PTCHX) are also considered in the present study for comparison with (PTOTHX). This paper aims to outline the numerical analysis procedures for determining the viability of the PTOTHX by comparing its heat transfer performance with the PTCHX units. The computational study used STAR-CCM+, a commercial computational fluid dynamics (CFD) code. Sensitivity analysis and model selection studies are conducted to determine the appropriate mesh density and turbulence model to provide the reported results. Numerical analyses comparing the Nusselt number (Nu) of the PTOTHX design with a comparable HX unit, including a circular cross-section and no twisting (PTCHX), show an overall heat transfer performance increase of 29-55% for balanced flow and 29-59% for imbalanced flow. Oval-cross-sectional twisted channels induce swirling flow vortices, enhancing the working fluid's convective heat transfer capabilities.

25 ENERGY STORAGE↗

Convection heat transfer of CO{sub 2} at supercritical pressures in a vertical mini tube at relatively low reynolds numbers

Convection heat transfer of CO{sub 2} at supercritical pressures in a 0.27 mm diameter vertical mini tube was investigated experimentally and numerically for upward and downward flows at relatively low inlet Reynolds numbers (2900 and 1900). The effects of inlet temperature, pressure, mass flow rate, heat flux, flow direction, buoyancy and flow acceleration on the convection heat transfer were investigated. For inlet Reynolds numbers less than 2.9 x 10{sup 3}, the local wall temperature varies non-linearly for both flow directions at high heat fluxes (113 kW/m{sup 2}). For the mini tube used in the current study, the buoyancy effect is normally low even when the heating is relatively strong, while the flow acceleration due to heating can strongly influence the turbulence and reduce the heat transfer for high heat fluxes. For relatively low Reynolds numbers (Re{sub in} {<=} 2.9 x 10{sup 3}) and the low heat flux (30.0 kW/m{sup 2}) the predicted values using the LB low Reynolds number correspond well with the measured data. However, for the high heat flux (113 kW/m{sup 2}), the predicted values do not correspond well with the measured data due to the influence of the flow acceleration on the turbulence. (author)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance of Gas-Engine Driven Heat Pump Unit

Air-conditioning (cooling) for buildings is the single largest use of electricity in the United States (U.S.). This drives summer peak electric demand in much of the U.S. Improved air-conditioning technology thus has the greatest potential impact on the electric grid compared to other technologies that use electricity. Thermally-activated technologies (TAT), such as natural gas engine-driven heat pumps (GHP), can provide overall peak load reduction and electric grid relief for summer peak demand. GHP offers an attractive opportunity for commercial building owners to reduce electric demand charges and operating expenses. Engine-driven systems have several potential advantages over conventional single-speed or single-capacity electric motor-driven units. Among them are variable speed operation, high part load efficiency, high temperature waste heat recovery from the engine, and reduced annual operating costs (SCGC 1998). Although gas engine-driven systems have been in use since the 1960s, current research is resulting in better performance, lower maintenance requirements, and longer operating lifetimes. Gas engine-driven systems are typically more expensive to purchase than comparable electric motor-driven systems, but they typically cost less to operate, especially for commercial building applications. Operating cost savings for commercial applications are primarily driven by electric demand charges. GHP operating costs are dominated by fuel costs, but also include maintenance costs. The reliability of gas cooling equipment has improved in the last few years and maintenance requirements have decreased (SCGC 1998, Yahagi et al. 2006). Another advantage of the GHP over electric motor-driven is the ability to use the heat rejected from the engine during heating operation. The recovered heat can be used to supplement the vapor compression cycle during heating or to supply other process loads, such as water heating. The use of the engine waste heat results in greater operating efficiency compared to conventional electric motor-driven units (SCGC 1998). In Japan, many hundreds of thousands of natural gas-driven heat pumps have been sold (typically 40,000 systems annually) (Yahagi et al. 2006). The goal of this program is to develop dependable and energy efficient GHPs suitable for U.S. commercial rooftop applications (the single largest commercial product segment). This study describes the laboratory performance evaluation of an integrated 10-ton GHP rooftop unit (a 900cc Daihatsu-Aisin natural gas engine) which uses R410A as the refrigerant (GEDAC No.23). ORNL Thermally-Activated Heat Pump (TAHP) Environmental Chambers were used to evaluate this unit in a controlled laboratory environment.

03 NATURAL GAS↗

Analysis on the Heat Transfer Phenomena Inside the Scaled-Down VHTR RCCS Riser Experiment

Very High Temperature gas-cooled Reactor (VHTR) that is one of GEN-IV reactors has been developed for the purpose of hydrogen production. VHTR is characterized by high operating temperature and stepped-up inherent safety given by passive safety systems such as Reactor Cavity Cooling System (RCCS). In case the active heat removal system losses its capability, RCCS significantly contributes to the inherent safety of VHTR by removing the decay heat transferred from the reactor core to the reactor vessel. Therefore, the performance of RCCS is the key parameter to ensure the safety of the reactor. Several computation and experiment researches on the performance of RCCS have been conducted. There are two types of RCCS depending on its coolant; one is the air-cooled type and the other is water-cooled type. This study focused on the former type. Due to the excessive height of the prototype RCCS, experiment facilities were constructed in reduced scale. Korea Atomic Energy Research Institute (KAERI) constructed the quarter-scale RCCS experiment facility, NACEF and Argonne National Laboratory (ANL) has constructed half-scale experiment facility, NSTF. University of Wisconsin (UW) also has the quarter-scale experiment facility and Texas A and M University has conducted separate effect test on the jet effect at the upper plenum of RCCS. From the reduced scale experiment result, the performance of RCCS such as a heat removal rate of RCCS and a peak temperature of reactor vessel were evaluated. When the reduced-scale result is applied to the prototype, however, a distortion could be brought about due to the reduced height of RCCS in the experiments. Especially, if the heat transfer regime inside the riser which roles as a heat exchanger to discharge the decay heat into the atmosphere is not identical, the riser wall temperature and the consequent reactor vessel temperature of the prototype could be incorrectly predicted. Thus, the convective heat transfer phenomena inside the riser duct both in the reduced scale and in the prototype is necessary to be investigated. In this study, the preliminary analysis on the heat transfer phenomena inside the RCCS riser was conducted. The subjects of the analysis were the prototype RCCS riser of PMR 200, and its scaled-down experiment facilities, NACEF. First, the geometry, flow and thermal conditions of the riser in PMR200 RCCS and NACEF were introduced with a scaling method. And then, the heat transfer regimes and the heat transfer coefficient corresponding to each condition were predicted using correlation and CFD calculation. Finally, planned activities including the experiment was introduced. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A two-phase three-field modeling framework for heat pipe application in nuclear reactors

Heat pipes and two-phase thermosyphons are highly efficient heat transfer devices utilizing continuous evaporation and condensation of working fluid for two-phase heat transport in closed systems. Because of the nearly isothermal and fully passive phase-change heat transfer mechanism, heat pipes and thermosyphons have found many applications in nuclear engineering, space technologies, and other energy systems. High-temperature heat pipes are used in nuclear microreactors to remove fission power from the primary system and are coupled with power conversion systems or process heat applications. Modeling of the two-phase flow phenomena inside a heat pipe is essential to its design and safety analysis. In this study, a comprehensive one-dimensional two-phase three-field flow model has been developed for the analysis of heat pipes in normal operation conditions and transients. The conservation or field equations of mass, momentum, and energy were developed for the liquid film, vapor, and droplet. In addition, constitutive models or correlations were reviewed thoroughly and provided for the closure of the three-field equations. Specific constitutive equations regarding interfacial mass and heat transfer at two interfaces, namely film-gas interface and gas-droplet interface, were reviewed for droplet entrainment and deposition rates as well as film and droplet evaporation rates. Furthermore, mechanistic correlations of annular flow film thickness were recommended for the modeling of the thermosyphons without a wick as a critical constitutive correlation. Furthermore, experimental data needs from new experiments using a prototype working fluid or surrogate fluids for the model validation of high-temperature heat pipes in microreactors were recommended for future research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On Variations of Space-heating Energy Use in Office Buildings

Space heating is the largest energy end use, consuming more than 7 quintillion joules of site energy annually in the U.S. building sector. A few recent studies showed discrepancies in simulated space-heating energy use among different building energy modeling programs, and the simulated results are suspected to be underpredicting reality. While various uncertainties are associated with building simulations, especially when simulations are performed by different modelers using different simulation programs for buildings with different configurations, it is crucial to identify and evaluate key driving factors to space-heating energy use in order to support the design and operation of low-energy buildings. In this study, 10 design and operation parameters for space-heating systems of two prototypical office buildings in each of three U.S. heating climates are identified and evaluated, using building simulations with EnergyPlus, to determine the most influential parameters and their impacts on variations of space-heating energy use. The influence of annual weather change on space-heating energy is also investigated using 30-year actual weather data. The simulated space-heating energy use is further benchmarked against those from similar actual office buildings in two U.S. commercial-building databases to better understand the discrepancies between simulated and actual energy use. In summary, variations of both the simulated and actual space-heating energy use of office buildings in all three heating climates can be very large. However these variations are mostly driven by a few influential parameters related to building design and operation. The findings provide insights for building designers, owners, operators, and energy policy makers to make better decisions on energy-efficiency technologies to reduce space-heating energy use for both new and existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and dynamic modeling of printed circuit heat exchangers for supercritical carbon dioxide Brayton power cycles

Due to the unique geometries and hydraulics of printed circuit heat exchangers and rapidly changing properties of supercritical carbon dioxide, the effective design and rating of printed circuit heat exchangers is an essential requirement for their use in supercritical carbon dioxide power cycles. In this study, one-dimensional design and dynamic models have been developed in Aspen Custom Modeler for printed circuit heat exchangers utilized in printed circuit heat exchangers Brayton power cycles. The design model is used to determine the optimal geometry parameters by minimizing the metal mass. The dynamic model is used to predict transient behavior and can be easily implemented into system-level models developed in Aspen Plus Dynamics for cycle performance evaluations. In these models, the heat transfer coefficient and friction factor are calculated using data reported by Heatric, a prominent printed circuit heat exchanger manufacturer. Both models are validated by comparing with the data from a small-scale exchanger used in the 100 kWe facility operated by the Naval Nuclear Laboratory, and then applied to design and simulate low- and high-temperature recuperators for a 10 MWe supercritical carbon dioxide indirect recompression closed Brayton cycle, which is of interest to the U.S. Department of Energy. The designs and dynamic responses of the printed circuit heat exchangers are compared with conventional shell-and-tube exchangers and microtube shell-and-tube exchangers for the same applications. Here, the simulation results indicate that the proposed printed circuit heat exchangers have fast dynamic responses due to their small metal masses and high heat transfer coefficients compared with the conventional shell-and-tube exchangers. Even though the metal masses of the designed PCHEs are slightly higher than those of the microtube shell-and-tube exchangers, the printed circuit heat exchangers are still promising candidates for heat recuperation because of their mature manufacturing procedures and abundant laboratory and industrial operating experience.

42 ENGINEERING↗

Direct Measurement of the Selective Microwave-Induced Heating of Agglomerates of Dipolar Molecules: The Origin of and Parameters Controlling a Microwave Specific Superheating Effect

Agglomerates of polar molecules in nonpolar solvents are selectively heated by microwave radiation. The magnitude of the selective heating was directly measured by using the temperature dependence of the intensities of the Stokes and anti-Stokes bands in the Raman spectra of p-nitroanisole (pNA) and mesitylene. Under dynamic heating conditions, a large apparent temperature difference (ΔT) of over 100 °C was observed between the polar pNA solute and the nonpolar mesitylene solvent. This represents the first direct measurement of the selective microwave heating process. The magnitude of the selective microwave heating was affected by the properties of the agglomerated pNA. As the concentration of the pNA increases, the magnitude of the selective heating of the pNA was observed to decrease. This is explained by the tendency of the pNA dipoles to orient in an antiparallel fashion in the aggregates as measured by the Kirkwood g value, which decreased with increasing concentration. This effect reduces the net dipole moment of the agglomerates, which decreases the microwave absorption. After the radiation was terminated, the effective temperature of the dipolar molecules returned slowly to that of the medium. The slow heat transfer was modeled successfully by treating the solutions as a biphasic solvent/solute system. Based on modeling and the fact that the agglomerate can be heated above the boiling temperature of the solvent, an insulating layer of solvent vapor is suggested to form around the heated agglomerate, slowing convective heat transfer out of the agglomerate. Furthermore, this is an effect unique to microwave heating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined resistive and laser heating technique for in situ radial X-ray diffraction in the diamond anvil cell at high pressure and temperature

To extend the range of high-temperature, high-pressure studies within the diamond anvil cell, a Liermann-type diamond anvil cell with radial diffraction geometry (rDAC) was redesigned and developed for synchrotron X-ray diffraction experiments at beamline 12.2.2 of the Advanced Light Source. The rDAC, equipped with graphite heating arrays, allows simultaneous resistive and laser heating while the material is subjected to high pressure. The goals are both to extend the temperature range of external (resistive) heating and to produce environments with lower temperature gradients in a simultaneously resistive- and laser-heated rDAC. Three different geomaterials were used as pilot samples to calibrate and optimize conditions for combined resistive and laser heating. For example, in Run1, FeO was loaded in a boron-mica gasket and compressed to 11 GPa then gradually resistively heated to 1007 K (1073 K at the diamond side). The laser heating was further applied to FeO to raise temperature to 2273 K. In Run2, Fe-Ni alloy was compressed to 18 GPa and resistively heated to 1785 K (1973 K at the diamond side). The combined resistive and laser heating was successfully performed again on (Mg{sub 0.9}Fe{sub 0.1})O in Run3. In this instance, the sample was loaded in a boron-kapton gasket, compressed to 29 GPa, resistive-heated up to 1007 K (1073 K at the diamond side), and further simultaneously laser-heated to achieve a temperature in excess of 2273 K at the sample position. Diffraction patterns obtained from the experiments were deconvoluted using the Rietveld method and quantified for lattice preferred orientation of each material under extreme conditions and during phase transformation.

36 MATERIALS SCIENCE↗

Heating-induced glass-glass and glass-liquid transformations in computer simulations of water

Water exists in at least two families of glassy states, broadly categorized as the low-density (LDA) and high-density amorphous ice (HDA). Remarkably, LDA and HDA can be reversibly interconverted via appropriate thermodynamic paths, such as isothermal compression and isobaric heating, exhibiting first-order-like phase transitions. We perform out-of-equilibrium molecular dynamics simulations of glassy water using the ST2 model to study the evolution of LDA and HDA upon isobaric heating. Depending on pressure, glass-to-glass, glass-to-crystal, glass-to-vapor, as well as glass-to-liquid transformations are found. Specifically, heating LDA results in the following transformations, with increasing heating pressures: (i) LDA-to-vapor (sublimation), (ii) LDA-to-liquid (glass transition), (iii) LDA-to-HDA-to-liquid, (iv) LDA-to-HDA-to-liquid-to-crystal, and (v) LDA-to-HDA-to-crystal. Similarly, heating HDA results in the following transformations, with decreasing heating pressures: (a) HDA-to-crystal, (b) HDA-to-liquid-to-crystal, (c) HDA-to-liquid (glass transition), (d) HDA-to-LDA-to-liquid, and (e) HDA-to-LDA-to-vapor. A more complex sequence may be possible using lower heating rates. For each of these transformations, we determine the corresponding transformation temperature as function of pressure, and provide a P-T “phase diagram” for glassy water based on isobaric heating. Our results for isobaric heating dovetail with the LDA-HDA transformations reported for ST2 glassy water based on isothermal compression/decompression processes [Chiu et al., J. Chem. Phys. 139, 184504 (2013)]. The resulting phase diagram is consistent with the liquid-liquid phase transition hypothesis. At the same time, the glass phase diagram is sensitive to sample preparation, such as heating or compression rates. Interestingly, at least for the rates explored, our results suggest that the LDA-to-liquid (HDA-to-liquid) and LDA-to-HDA (HDA-to-LDA) transformation lines on heating are related, both being associated with the limit of kinetic stability of LDA (HDA)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planning for cooler communities: Vacant lots as components of heat resilience in Mesa, Arizona

Vacant lots are often perceived as contributing to negative socioeconomic and environmental impacts on surrounding communities. However, they also offer opportunities for strategic interventions that promote heat resilience. This study uses a decision-scale congruence analytic approach to examine the correlation between extreme heat and community resilience in the context of vacant lots in the city of Mesa, Arizona. By identifying and analyzing over 1,200 vacant lots, we assessed spatial patterns of Community Resilience Estimates (CRE) for Heat and Body Heat Storage (BHS) to understand their correlation at the unit of analysis of vacant lots, where key decisions are made concerning land use. The results reveal a nonrandom spatial distribution of CRE for Heat and BHS across Mesa’s vacant lots. Vacant lots are disproportionately concentrated in neighborhoods with lower resilience, exacerbating heat exposure. Communities with limited access to cooling infrastructure, tree canopy, and other resources experience lowered heat resilience. A positive correlation between CRE for Heat and BHS shows that areas with higher heat exposure tend to have lower community resilience, reinforcing the need for cooling interventions. This study highlights the potential for converting vacant lots into heat-resilient, community-serving spaces. Using our findings, decision makers can identify priority areas and leverage vacant lots to mitigate heat impacts and foster community resilience.

community resilience↗

High-Fidelity Modeling and Experiments to Inform Safety Analysis Codes for Heat Pipe Microreactors

Heat pipe microreactors are reactor designs that primarily use liquid-metal heat pipes to cool the core. The main interest in heat pipes is the fact that they can remove heat passively. This, along with the use of liquid metal, allows the reactor to operate at higher temperatures. Although the use of heat pipes in nuclear reactors is new, liquid-metal heat pipe technology is mature. Nevertheless, experimental data on heat pipes are scarce, and very little is known about their behavior during abnormal operations and close to their thermal limits. Therefore, new experiments and accurate heat pipe simulations are needed to develop reliable closure models. This work describes a joint experimental and numerical investigation into heat pipes that attempts an initial closure of this gap. Further, the numerical and experimental efforts are currently proceeding in parallel, aimed at different aspects of heat pipes. The numerical part is focused on gaps in local closures, and the experiments capture the overall heat pipe behavior.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An improved model for the accurate calculation of parallel heat fluxes at the JET bulk tungsten outer divertor

Parallel heat flux calculations at the JET divertor have been based on the assumption that all incoming heat is due to the projection of the heat flux parallel to the magnetic line, q ∥ , plus a constant background. This simplification led to inconsistencies during the analysis of a series of dedicated tungsten melting experiments performed in 2013, for which infrared (IR) thermography surface measurements could not be recreated through simulations unless the parallel heat flux was reduced by 80% for L-mode and 60% for H-mode. We give an explanation for these differences using a new IR inverse analysis code, a set of geometrical corrections, and most importantly an additional term for the divertor heat flux accounting for non-parallel effects such as cross-field transport, recycled neutrals or charge exchange. This component has been evaluated comparing four different geometries with impinging angles varying from 2 to 90°. Its magnitude corresponds to 1.2%–1.9% of q ∥ , but because it is not affected by the magnetic projection, it accounts for up to 20%–30% of the tile surface heat flux. The geometrical corrections imply a further reduction of 24% of the measured heat flux. In addition, the application of the new inverse code increases the accuracy of the tile heat flux calculation, eliminating any previous discrepancy. The parallel heat flux computed with this new model is actually much lower than previously deduced by inverse analysis of IR temperatures—40% for L-mode and 50% for H-mode—while being independent of the geometry on which it is measured. This main result confirms the validity of the optical projection as long as a non-constant and non-parallel component is considered. For a given total heating power, the model predicts over 10% reduction of the maximum tile surface heat flux compared to strict optical modelling, as well as a 30% reduced sensitivity to manufacturing and assembling tolerances. Furthermore these conclusions, along with the improvement in the predictability of the divertor thermal behaviour, are critical for JET future DT operations, and are also directly applicable to the design of the ITER divertor monoblocks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗