Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTRONIC MODULE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Self-modulated nanostructures in super-large-period Bi{sub 11}(Fe{sub 5}CoTi{sub 3}){sub 10/9}O{sub 33} epitaxial thin films

Super-large-period Aurivillius thin films with a pseudo-period of ten were grown on (0 0 1) SrTiO{sub 3} substrates using the pulsed laser deposition method. The as-grown films are found to be coherently strained to the substrate and atomically smooth. X-ray diffraction indicates an average periodicity of ten, while analysis with the high resolution scanning transmission electron microscopy reveals a self-modulated nanostructure in which the periodicity changes as the film thickness increases. Finally, we discuss the magnetic and possible ferroelectric properties of the self-modulated large period Aurivillius films at the room temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced high-gain harmonic generation for x-ray free-electron laser

The harmonic generation free-electron laser (HG-FEL) is capable of producing temporally and spatially coherent pulses in the vacuum ultraviolet and shorter wavelength regions. In this letter an easy-to-implement scheme that significantly enhances the performance of HG-FEL and extends its short-wavelength range is proposed. By adding a short phase-reversed modulator after the dispersive section, the electron energy spread is reduced and simultaneously the electron microbunching is enhanced. Three-dimensional simulations demonstrate the energy spread reduction and the bunching enhancement and show that more powerful higher harmonic radiation can be obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On The Propagation And Modulation Of Electrostatic Solitary Waves Observed Near The Magnetopause On Cluster

We present the results of a study of Electrostatic Solitary Waves (ESWs) in which propagation of a series of noncyclical ESWs is observed from one Cluster spacecraft to another over distances as great as tens of km and time lags as great as a few tens of ms. This propagation study was conducted for locations near the magnetopause on the magnetosheath side. Propagation was found primarily toward the earth with speeds on the order of 1500 to 2400 km/s. The sizes of the ESWs obtained from these velocities were on the order of 1 km along the magnetic field direction and several tens of km perpendicular. These results are consistent with measurements on single spacecraft in which the ESW propagation is observed with time lags of only {approx}0.1 ms. Our results thus show the stability of ESWs over time periods much greater than their own characteristic pulse durations of a few 100s of microseconds. We present also the results of a study of ESW modulation at the magnetopause on the earthward side. We found that ESWs were modulated at {approx}1.3 Hz, consistent with a Pc1 wave which was observed concurrently. During this time, tens of eV electron beams are present. We propose a Buneman type instability in which the E{sub ''''} component of the Pc1 waves provides a mechanism for accelerating electrons, resulting in the generation of the ESWs modulated at the Pc1 frequency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using an Emittance Exchange Scheme for High Harmonic Generation by Free-Electron Lasers

We propose combining a transverse-to-longitudinal emittance exchange beam line and a conventional modulator to generate high harmonics with short-wavelength free-electron lasers. The key point of this scheme is the use of a multi-slit mask to create a transverse-shaped beam. In an emittance exchange beam line, the transverse-shaped bunch will produce a longitudinal-shaped one, resulting in separated energy bands. The modulator that follows this step will generate micro-bunches containing high harmonics. A coherent synchrotron radiation effect is also considered in this paper; compared to the two-modulator scheme, the method investigated here is more flexible and can be used to relax the coherent synchrotron radiation effect.

43 PARTICLE ACCELERATORS↗

Diagnostic x-ray source using electrons produced by a 100 J-class picosecond laser

Many laser-based high-energy-density science (HEDS) facilities have one or more short-pulse (sub- to few-picosecond) laser beams for diagnostics. For the past decade, we have been developing a novel x-ray probing capability using such picosecond lasers interacting with an underdense plasma to produce relativistic electrons. The ultimate goal of these experiments is to demonstrate a new type of x-ray backlighter using the short-pulse ARC laser at the National Ignition Facility (NIF). Before this diagnostic is fielded at the NIF, it is critical to demonstrate the viability and reproducibility of the x-ray source on comparable high-power short-pulse laser systems. We present experiments that were carried out with the OMEGA EP laser at the University of Rochester’s laboratory for laser energetics. In these experiments, high-energy electrons are produced through a combination of the self-modulation instability and direct laser acceleration in an underdense gas jet. These electrons generate directional x-rays with characteristic energies up to several tens of keV as they execute betatron motion in the ion channel, and the inverse Compton scattering process generates even harder x-rays, with characteristic photon energies of 60–240 keV. When implemented on the OMEGA EP laser(s), this x-ray source yields results that are comparable to those obtained recently on the short-pulse Titan laser at the Jupiter Laser Facility at Lawrence Livermore National Laboratory, after accounting for differences in laser energy, peak intensity, focusing f/#, and plasma source. Applications of such an x-ray source for HEDS experiments are discussed.

backlighter↗

Digitally Enhanced Heterodyne Interferometry

Spurious interference limits the performance of many interferometric measurements. Digitally enhanced interferometry (DEI) improves measurement sensitivity by augmenting conventional heterodyne interferometry with pseudo-random noise (PRN) code phase modulation. DEI effectively changes the measurement problem from one of hardware (optics, electronics), which may deteriorate over time, to one of software (modulation, digital signal processing), which does not. DEI isolates interferometric signals based on their delay. Interferometric signals are effectively time-tagged by phase-modulating the laser source with a PRN code. DEI improves measurement sensitivity by exploiting the autocorrelation properties of the PRN to isolate only the signal of interest and reject spurious interference. The properties of the PRN code determine the degree of isolation.

Shaddock, Daniel↗

Integrated modeling of electron cyclotron resonance ion sources and charge breeders with GEM, MCBC, and IonEx

A numerical toolset to help in understanding physical processes in the electron cyclotron resonance charge breeder (ECRCB) and further to help optimization and design of current and future machines is presented. The toolset consists of three modules (Monte Carlo charge breeding code, generalized electron cyclotron resonance ion source modeling, and ion extraction), each modeling different processes occurring in the ECRCB from beam injection to extraction. The toolset provides qualitative study, such as parameter studies, and scaling of the operation, and physical understanding in the ECRCB. The methodology and a sample integrated modeling are presented.

43 PARTICLE ACCELERATORS↗

Plasma electron contribution to beam emittance growth from Coulomb collisions in plasma-based accelerators

Coulomb collisions with background plasma can cause emittance growth in plasma accelerators. This paper extends the theory to consider collisions with not only motionless plasma ions but also plasma electrons with relativistic motion, based on the Frankel cross section. The theory is verified by particle-in-cell simulations with a Monte Carlo collision module. Further, it is shown that the electron contribution has the same amount as that of ions in linear acceleration regime and may not be negligible in nonlinear regime depending on the plasma electron density and its relativistic bulk velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a high efficiency relativistic backward wave oscillator with low guiding magnetic field

A high efficiency relativistic backward wave oscillator working at a low guiding magnetic field is designed and simulated. A trapezoidal resonant reflector is used to reduce the modulation field in the resonant reflector to avoid overmodulation of the electron beam which will lead to a large momentum spread and then low conversion efficiency. The envelope of the inner radius of the slow wave structure (SWS) increases stepwise to keep conformal to the trajectory of the electron beam which will alleviate the bombardment of the electron on the surface of the SWS. The length of period of the SWS is reduced gradually to make a better match between phase velocity and electron beam, which decelerates continually and improves the RF current distribution. Meanwhile the modulation field is reduced by the introduction of nonuniform SWS also. The particle in cell simulation results reveal that a microwave with a power of 1.8 GW and a frequency of 14.7 GHz is generated with an efficiency of 47% when the diode voltage is 620 kV, the beam current 6.1 kA, and the guiding magnetic field 0.95 T.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating conversion of negative muons into electrons in the coulomb field of an Al nucleus, planning to reach a single event sensitivity of about $3\cdot10^{−17}$, four orders of magnitude beyond the current best limit.The conversion electron has a clear monoenergetic signature at 104.967 MeV, slightly below the muon rest mass, and will be identified by a complementary measurement carried out by a high-resolution tracker and an electromagnetic calorimeter (EMC). The calorimeter is composed of 1348 pure CsI crystals, each read by two custom UV-extended SiPMs, that are arranged in two annular disks. The EMC should achieve better than 10% energy resolution and 500 ps timing resolution for 100 MeV electrons and maintain extremely high levels of reliability and stability and in a harsh operating environment with high vacuum, 1 T B-field and radiation exposures up to 100 krad and $10^{12} \rm{n}_\rm{1MeVeq}/\rm{cm}^{2}$.The calorimeter technological choice, along with the design of the custom front-end electronics, cooling and mechanical systems were validated through an electron beam test on a large-scale 51-crystals prototype (Module-0) and extensive test campaigns that characterised and verified the performance of crystals, photodetectors, analogue and digital electronics. This included hardware stress tests and irradiation campaigns with neutrons, protons, and photons.The production and QC phases of all calorimeter components is completed apart for the digital electronics that has been revised for improving its resilience to SEU and SEL. A series of vertical slice tests with the final electronics is being carried out on the Module-0 at LNF along with the implementation and validation of the calibration procedures. The first disk has been assembled in 2022 while the second disk is under assembly at the moment of writing. Status of construction will be summarised, along with plans for commissioning and first calibration of the fully assembled disks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Coherent Synchrotron Radiation and its Impact on the LCLS Electron Beam

In order to reach the high peak current required for an x-ray FEL, two separate magnetic dipole chicanes are used in the LCLS accelerator to compress the electron bunch length in stages. In these bunch compressors, coherent synchrotron radiation (CSR) can be emitted-induced either by a short electron bunch, or by any longitudinal density modulation that may be on the bunch. We present measurements, simulations, and analysis of (1) the CSR-induced energy loss, (2) the related transverse emittance growth, and (3) the microbunching-induced CSR directly observed at optical wavelengths.

43 PARTICLE ACCELERATORS↗

On benchmarking of simulations of particle transport in ITER

We present results of benchmarking of core particle transport simulations by a collection of codes widely used in transport modelling of tokamak plasmas. Our analysis includes formulation of transport equations, difference between electron and ion solvers, comparison of modules of the pellet and edge gas fuelling on the ITER baseline scenario. During the first phase of benchmarking we address the particle transport effects in the stationary phase. Firstly, simulations are performed with identical sources, sinks, transport coefficients, and boundary conditions prescribed in the flattop H-mode phase. The transformation of ion particle transport equations is introduced so to directly compare their results to electron transport solvers. Moreover, the pellet fuelling models are benchmarked in various conditions to evaluate the dependency of the pellet deposition on the pellet volume, injection side, pedestal and separatrix parameters. Thirdly, edge gas fuelling is benchmarked to assess sensitivities of source profile predictions to uncertainties in plasma conditions and detailed model assumptions. At the second phase, we address particle transport effects in the time-evolving plasma including the current ramp-up to the ramp-down phase. The ion and the electron solvers are benchmarked together. Differences between the simulation results of the solvers are investigated in terms of equilibrium, grid resolution, radial coordinate, radial grid distribution, and plasma volume evolution term. We found that the selection of the radial coordinate can yield prominent differences between the solvers mainly due to differences in the edge grid distribution. The simulations reveal that electron and ion solvers predict noticeably different density peaking for the same diffusion and pinch velocity while with the peaked profile of helium, expected in fusion reactors. The fuelling benchmarking demonstrates that gas puffing is not efficient for core fuelling in H-modes and density control should be done by the high field side pellet injection in contrast to present machines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetooptical study of CdSe/ZnMnSe semimagnetic quantum-dot ensembles with n-type modulation doping

Magnetic and polarization investigations of the photoluminescence and resonant electron spin-flip Raman scattering in ensembles of self-organized CdSe/ZnMnSe semimagnetic quantum dots with n-type modulation doping are carried out. It is demonstrated that exciton transitions contribute to the photoluminescence band intensity, along with the transitions of trions in the singlet state. In the Hanle-effect measurements, negative circular polarization in zero magnetic field is observed, which is related to the optical orientation of a trion heavy hole. The lifetime and spin-relaxation time of a heavy hole are estimated as ≤3 and ≤1 ps, respectively. Such short times are assumed to be due to Auger recombination with the excitation of an intrinsic transition in a Mn{sup 2+} ion. Investigations of the photoluminescence-maximum intensity and shift in a longitudinal magnetic field at the σ{sup −}σ{sup +} and σ{sup −}σ{sup −} polarizations reveal the pronounced spin polarization of electrons. Under resonant excitation conditions, a sharp increase in the photoluminescence-band maximum intensity at σ{sup −} excitation polarization over the σ{sup +} one is observed. The Raman scattering peak at the electron spin-flip transition is observed upon resonant excitation in a transverse magnetic field in crossed linear polarizations. This peak is shown to be a Brillouin function of a magnetic field.

36 MATERIALS SCIENCE↗

Performance enhancement of perovskite solar cells with Mg-doped TiO{sub 2} compact film as the hole-blocking layer

In this letter, we report perovskite solar cells with thin dense Mg-doped TiO{sub 2} as hole-blocking layers (HBLs), which outperform cells using TiO{sub 2} HBLs in several ways: higher open-circuit voltage (V{sub oc}) (1.08 V), power conversion efficiency (12.28%), short-circuit current, and fill factor. These properties improvements are attributed to the better properties of Mg-modulated TiO{sub 2} as compared to TiO{sub 2} such as better optical transmission properties, upshifted conduction band minimum (CBM) and downshifted valence band maximum (VBM), better hole-blocking effect, and higher electron life time. The higher-lying CBM due to the modulation with wider band gap MgO and the formation of magnesium oxide and magnesium hydroxides together resulted in an increment of V{sub oc}. In addition, the Mg-modulated TiO{sub 2} with lower VBM played a better role in the hole-blocking. The HBL with modulated band position provided better electron transport and hole blocking effects within the device.

30 DIRECT ENERGY CONVERSION↗

Solar powered hybrid sensor module program

Geo-orbital systems of the near future will require more sophisticated electronic and electromechanical monitoring and control systems than current satellite systems with an emphasis in the design on the electronic density and autonomy of the subsystem components. Results of a project to develop, design, and implement a proof-of-concept sensor system for space applications, with hybrids forming the active subsystem components are described. The design of the solar power hybrid sensor modules is discussed. Module construction and function are described. These modules combined low power CMOS electronics, GaAs solar cells, a crystal oscillatory standard UART data formatting, and a bidirectional optical data link into a single 1.25 x 1.25 x 0.25 inch hybrid package which has no need for electrical input or output. Several modules were built and tested. Applications of such a system for future space missions are also discussed.

Johnson, J. M.↗

First Results of the LCLS Laser-Heater System

he very bright electron beam required for an x-ray free electron laser (FEL), such as the LCLS, is susceptible to a microbunching instability in the magnetic bunch compres sors, prior to the FEL undulator. The uncorrelated electron energy spread in the LCLS can be increased by an order of magnitude to provide strong Landau damping against the instability without degrading the FEL performance. To this end, a ‘laser-heater’ system has been installed in the LCLS injector, which modulates the energy of a 135-MeV electron bunch with an IR laser beam in a short undulator, enclosed within a four-dipole chicane. The last half of the chicane time-smears the energy modulation leaving an effective thermal energy spread increase. We present the first commissioning results of this system, its operational issues, its impact on the microbunching instability, and finally its effect on the FEL performance.

43 PARTICLE ACCELERATORS↗

Solution‐Processed Spin‐Polarized Light‐Emitting Diodes of Colloidal Quantum Wells and Magnetic Nanoparticles

Electrical injection of spin-polarized carriers into semiconductors enables circularly-polarized emission from spin-polarized light-emitting diodes (spin-LEDs). The incredible level of tunability of magnetic and electronic properties in colloidal nanocrystals offers unprecedented opportunities for the modulation of polarization of light in solution-processed spin-LEDs based on magnetic nanoparticles unlike epitaxially grown spin-LEDs restricted by a very limited range of materials for their exploitation, and solution-processed spin-LEDs based on chiral molecules, which do not allow the modulation of polarization in general. Here, it is shown that electrical injection of spin-polarized electrons from magnetic Fe 3 O 4 nanoparticles into CdSe/CdZnS core/shell colloidal quantum wells (CQWs) in solution-processed LEDs that allows for polarization modulation of electroluminescence. In this structure, a monolayer of face-down oriented CQWs is deposited as an active layer to avoid polarization losses due to the hopping of the electrons between the CQWs before the radiative recombination process. In this solution-processed spin-LED, the circular polarization reaches 4.5% at 3 K and survives up to 100 K. A net circular polarization is observed at zero magnetic field up to 100 K because of the remnant magnetization of the Fe 3 O 4 nanoparticles. This new colloidal spin-LED architecture presents significant prospects for future solution-processed advanced opto-spintronic devices.

circularly polarized electroluminescence↗