Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Forward Drift Chamber for the GlueX Experiment at the 12 GeV CEBAF Machine

The GlueX experiment will search for exotic mesons produced by 9 GeV linearly polarized photons from the upgraded CEBAF machine. It is critical to detect and measure the four-momenta of all the charged particles and photons resulting from the decays of the mesons. The solenoid-based detector system includes tracking detectors and calorimeters. The Forward Drift Chamber, FDC, consists of 24 circular planar drift chambers of 1m diameter. Additional cathode readout is required to achieve efficient pattern recognition. The detection of photons by the electromagnetic calorimeters imposes constraints on the amount of material used in the FDC. The specific features of the detector and the readout electronics will be described. Results from the tests of the full scale prototype will be presented, as well.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Focal Surface of the JEM-EUSO Instrument

The Extreme Universe Space Observatory on JEM/EF (JEM-EUSO) is a space mission to study extremely high-energy cosmic rays. The JEM-EUSO instrument is a wide-angle refractive telescope in the near-ultraviolet wavelength region which will be mounted to the International Space Station. Its goal is to measure time-resolved fluorescence images of extensive air showers in the atmosphere. In this paper we describe in detail the main features and technological aspects of the focal surface of the instrument. The JEM-EUSO focal surface is a spherically curved surface, with an area of about 4.5m{sup 2}. The focal surface detector is made of more than 5,000 multi-anode photomultipliers (MAPMTs). Current baseline is Hamamatsu R11265-03-M64. The approach to the focal surface detector is highly modular. Photo-Detector-Modules (PDM) are the basic units that drive the mechanical structure and data acquisition. Each PDM consists of 9 Elementary Cells (ECs). The EC, which is the basic unit of the MAPMT support structure and of the front-end electronics, contains 4 units of MAPMTs. In total, about 1,200 ECs or about 150 PDMs are arranged on the whole of the focal surface of JEM-EUSO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TESTING THE NO-HAIR THEOREM WITH OBSERVATIONS IN THE ELECTROMAGNETIC SPECTRUM. IV. RELATIVISTICALLY BROADENED IRON LINES

According to the no-hair theorem, astrophysical black holes are fully characterized by their masses and spins and are described by the Kerr metric. This theorem can be tested observationally by measuring (at least) three different multipole moments of the spacetimes of black holes. In this paper, we calculate the profiles of fluorescent iron lines emitted from the accretion flows around black hole candidates within a framework that allows us to perform the calculation as a function of its mass and spin as well as of a free parameter that measures potential deviations from the Kerr metric. We show that such deviations lead to line profiles that are significantly altered and may exhibit a modified flux ratio of the two peaks in their characteristic double-peaked shape. We also show that the disk inclination can be measured independently of the spin and the deviation parameter at low to intermediate inclination angles, as in the case of Kerr black holes. We estimate the precision that near-future X-ray missions such as Astro-H and ATHENA+ are required to achieve in order to resolve deviations from the Kerr metric in iron line profiles and show that constraints on such deviations will be strongest for rapidly spinning black holes. More generally, we show that measuring the line profile with a precision of {approx}5% at disk inclinations of 30 Degree-Sign or 60 Degree-Sign constrains the deviation parameter to order unity for values of the spin a {approx}> 0.5M.

79 ASTRONOMY AND ASTROPHYSICS↗

MULTI-STRANDED AND MULTI-THERMAL SOLAR CORONAL LOOPS: EVIDENCE FROM HINODE X-RAY TELESCOPE AND EUV IMAGING SPECTROMETER DATA

Data from the X-Ray Telescope (XRT) and the EUV Imaging Spectrometer (EIS) on the Japanese/USA/UK Hinode spacecraft were used to investigate the spatial and thermal properties of an isolated quiescent coronal loop. We constructed differential emission measure (DEM) curves using Monte Carlo based, iterative forward fitting algorithms. We studied the loop as a whole, in segments, in transverse cuts, and point-by-point, always with some form of background subtraction, and find that the loop DEM is neither isothermal nor extremely broad, with approximately 96% of the EM between 6.2 {<=}log T{<=} 6.7, and an EM-weighted temperature of log T = 6.48 {+-} 0.16. We find evidence for a gradual change in temperature along the loop, with log T increasing only by {approx}0.1 from the footpoints to the peak. The combine XRT-EIS data set does a good job of constraining the temperature distribution for coronal loop plasma. Our studies show that the strong constraints at high and low temperatures provided by the combined data set are crucial for obtaining reasonable solutions. These results confirm that the observations of at least some loops are not consistent with isothermal plasma, and therefore cannot be modeled with a single flux tube and must be multi-stranded.

79 ASTRONOMY AND ASTROPHYSICS↗

J/ ψ -hadron correlations at midrapidity in pp collisions at $\sqrt{s}$ = 13 TeV

We report on the measurement of inclusive, non-prompt, and prompt J/ψ-hadron correlations by the ALICE Collaboration at the CERN Large Hadron Collider in pp collisions at a center-of-mass energy of 13 TeV. The correlations are studied at midrapidity (|y| < 0.9) in the transverse momentum ranges p T < 40 GeV/c for the J/ψ and 0.15 < p T < 10 GeV/c and |η| < 0.9 for the associated hadrons. The measurement is based on minimum bias and high multiplicity data samples corresponding to integrated luminosities of L int = 34 nb −1 and L int = 6.9 pb −1 , respectively. In addition, two more data samples are employed, requiring, on top of the minimum bias condition, a threshold on the tower energy of E = 4 and 9 GeV in the ALICE electromagnetic calorimeters, which correspond to integrated luminosities of L int = 0.9 pb −1 and L int = 8.4 pb −1 , respectively. The azimuthally integrated near and away side yields of associated charged hadrons per J/ψ trigger are presented as a function of the J/ψ and associated hadron transverse momentum. The measurements are discussed in comparison to PYTHIA calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Relativistic effects in ab initio electron-nucleus scattering

The electromagnetic responses obtained from Green's function Monte Carlo (GFMC) calculations are based on realistic treatments of nuclear interactions and currents. The main limitations of this method comes from its nonrelativistic nature and its computational cost, the latter hampering the direct evaluation of the inclusive cross sections as measured by experiments. We extend the applicability of GFMC in the quasielastic region to intermediate momentum transfers by performing the calculations in a reference frame that minimizes nucleon momenta. Additional relativistic effects in the kinematics are accounted for employing the two-fragment model. In addition, we developed a novel algorithm, based on the concept of first-kind scaling, to compute the inclusive electromagnetic cross section of 4 He through an accurate and reliable interpolation of the response functions. A very good agreement is obtained between theoretical and experimental cross sections for a variety of kinematical setups. Finally, this offers a promising prospect for the data analysis of neutrino-oscillation experiments that requires an accurate description of nuclear dynamics in which relativistic effects are fully accounted for.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prototype muon detectors for the AMIGA component of the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary Cell, are to identify and resolve all engineering issues as well as to understand the muon-number counting uncertainties related to the design of the detector. The mechanical design, fabrication and deployment processes of the muon counters of the Unitary Cell are described in this document. These muon counters modules comprise sealed PVC casings containing plastic scintillation bars, wavelength-shifter optical fibers, 64 pixel photomultiplier tubes, and acquisition electronics. The modules are buried approximately 2.25 m below ground level in order to minimize contamination from electromagnetic shower particles. The mechanical setup, which allows access to the electronics for maintenance, is also described in addition to tests of the modules' response and integrity. As a result, the completed Unitary Cell has measured a number of air showers of which a first analysis of a sample event is included here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single Crystal Diamond Beam Position Monitors with Radiofrequency Electronic Readout

Over the energy range 5{approx}30 keV a suitably contacted, thin ({approx}100 {mu}m) diamond plate can be operated in situ as a continuous monitor of X-ray beam intensity and position as the diamond absorbs only a small percentage of the incident beam. Single crystal diamond is a completely homogeneous material showing fast (ns), spatially uniform signal response and negligible (<pA) leakage currents. Due to its unsurpassed thermal conductivity, it is the only semiconductor material that can be used in intense synchrotron white beams. We report on tests made at ESRF and DESY using diamond beam position monitors of simple quadrant electrode designs with metal contacts, operated using wideband electronic readout corresponding to the RF accelerator frequency. The instrumentation for these monitors must cover a large range of operating conditions: different beam sizes, fluxes, energies and time structure corresponding to the synchrotron fill patterns. Sophisticated new RF sampling electronics can satisfy most requirements: using a modified Libera Brilliance readout system, we measured the center of gravity position of a 25 {mu}m beam at the DORIS III F4 beam line at a rate of 130 Msample/s with narrowband filtering of a few MHz bandwidth. Digitally averaging the signal further provided a spatial resolution {approx}20 nm.

43 PARTICLE ACCELERATORS↗

Baryon spectroscopy: Recent results from the Crystal Barrel/TAPS experiment at ELSA

To understand the spectrum and the properties of baryon resonances, the CBELSA/TAPS experiment at ELSA investigates the photoproduction of single- and multi-meson final states off the nucleon. In the latter final states baryon cascades via Dp and Dh and also via higher mass baryon resonances are clearly observed. A partial wave analysis based on single and double meson photoproduction data as well as data from other reactions allows a first determination of resonance properties including partial decay widths of various N* and {Delta}* states. Those include also the decays into the different p{pi}{sup 0{pi}0} and p{pi}{sup 0{eta}} decay channels resulting partly in unexpected results. Recently not only single but also double polarisation experiments have been performed, which are absolutelly necessary to resolve ambiguities in the partial wave analyses (PWA) used to extract the resonances from the data; without the measurement of polarisation observables a model-independent PWA will not be possible. Polarisation observables have been investigated using linearly, circularly polarized or unpolarized photons impinging on an longitudinally polarized or unpolarized target. Given the angular coverage of the Crystal-Barrel/TAPS experiment this data cover almost the full angular range and phase space. This data will provide key information for the partial wave analyses and brings us one step closer towards the needed complete experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-crystal sapphire resonator at millikelvin temperatures: Observation of thermal bistability in high-Q factor whispering gallery modes

Resonance modes in single crystal sapphire ({alpha}-Al{sub 2}O{sub 3}) exhibit extremely high electrical and mechanical Q factors ({approx_equal}10{sup 9} at 4 K), which are important characteristics for electromechanical experiments at the quantum limit. We report the cool down of a bulk sapphire sample below superfluid liquid-helium temperature (1.6 K) to as low as 25 mK. The electromagnetic properties were characterized at microwave frequencies, and we report the observation of electromagnetically induced thermal bistability in whispering gallery modes due to the material T{sup 3} dependence on thermal conductivity and the ultralow dielectric loss tangent. We identify ''magic temperatures'' between 80 and 2100 mK, the lowest ever measured, at which the onset of bistability is suppressed and the frequency-temperature dependence is annulled. These phenomena at low temperatures make sapphire suitable for quantum metrology and ultrastable clock applications, including the possible realization of the quantum-limited sapphire clock.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of an X-ray Pinhole Monitor at NSRRC

An X-ray pinhole monitor is designed to measure the size, emittance and energy spread of the electron beam at NSRRC. The profile of the electron beam in a synchrotron radiation source is commonly assessed with a pinhole monitor of a cheap and simple design. To increase the resolution of the measurement, one method is to use the X-ray regime. The beam passes through a pinhole and the low-energy photons are eliminated with a filter. The beam profile is imaged with a fluorescent screen. The pinhole dimension is optimized on minimizing the diffraction blurring and maximizing the geometric resolution. The X-ray pinhole monitor is simulated with a SRW program. We designed an X-ray pinhole monitor to have three sets of pinhole array, six sets of filters and three sets to screens to increase the information acquired about the characteristics of the X-ray pinhole monitor. The simulation and design are presented here.

43 PARTICLE ACCELERATORS↗

TIME-SEQUENCED X-RAY OBSERVATION OF A THERMAL EXPLOSION

The evolution of a thermally-initiated explosion is studied using a multiple-image x-ray system. HMX-based PBX 9501 is used in this work, enabling direct comparison to recently-published data obtained with proton radiography [1]. Multiple x-ray images of the explosion are obtained with image spacing of ten microseconds or more. The explosion is simultaneously characterized with a high-speed camera using an interframe spacing of 11 mus. X-ray and camera images were both initiated passively by signals from an embedded thermocouple array, as opposed to being actively triggered by a laser pulse or other external source. X-ray images show an accelerating reacting front within the explosive, and also show unreacted explosive at the time the containment vessel bursts. High-speed camera images show debris ejected from the vessel expanding at 800-2100 m/s in the first tens of mus after the container wall failure. The effective center of the initiation volume is about 6 mm from the geometric center of the explosive.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma Diagnostics of a Capillary Plasma Channel for Laser Guiding

We demonstrated the production of an optical waveguide in a capillary discharge-produced plasma using a cylindrical capillary. Plasma parameters of its waveguide were characterized by use of both a Normarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 200 A. An ultrashort, intense laser pulse was guided by use of this plasma channel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative NO{sub 2} molecular tagging velocimetry at 500 kHz frame rate

NO{sub 2} molecular tagging velocimetry (MTV) is demonstrated at repetition rates as high as 500 kHz in a laboratory scale Mach 5 wind tunnel. A pulse burst laser and a home built optical parametric oscillator system were used to simultaneously generate the required 355 and 226 nm wavelengths for NO{sub 2} photodissociation (tagging) and NO planar laser induced fluorescence imaging (interrogation), respectively. NO{sub 2} MTV images were obtained both in front and behind the characteristic bow shock from a 5 mm diameter cylinder. From Gaussian curve fitting, an average free stream flow velocity of 719 m/s was obtained. Absolute statistical precision in velocity of {approx}11.5 m/s was determined, corresponding to relative precision of 1.6%-5%, depending upon the region of the flow probed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification of spin wave modes in yttrium iron garnet strongly coupled to a co-axial cavity

We demonstrate, at room temperature, the strong coupling of the fundamental and non-uniform magnetostatic modes of an yttrium iron garnet ferrimagnetic sphere to the electromagnetic modes of a co-axial cavity. The well-defined field profile within the cavity yields a specific coupling strength for each magnetostatic mode. We experimentally measure the coupling strength for the different magnetostatic modes and, by calculating the expected coupling strengths, we are able to identify the modes themselves.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental study of A0 Lamb wave tomography

Corrosion damage in inaccessible regions presents a significant challenge to the petrochemical industry, and determining the remaining wall thickness is important to establish the remaining service life. Guided wave tomography is one solution and involves transmitting Lamb waves through the area of interest and using the received signals to reconstruct the remaining wall thickness. This avoids the need to access all points on the surface, making the technique well suited to inspection beneath supports. For this purpose a tomography system for pipe inspections is developed using low frequency A0 Lamb waves that are excited and detected with two arrays of electromagnetic acoustic transducers (EMATs). Two different defect depths are considered with different contrasts relative to the nominal wall thickness and in a first step, the repeatability of the measurements is demonstrated. Due to the limited view array configuration, the maximum depth of the reconstruction underestimates the true depth. In a second experimental study, the influence of a pipe clamp on the thickness reconstruction is considered, representing an inspection problem with restricted access. Preliminary results have shown that the maximum defect depth is further underestimated when compared to the thickness reconstructions without the clamp. However, it is possible to detect the defect underneath the clamp for all conducted experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CHIANTI-AN ATOMIC DATABASE FOR EMISSION LINES. XI. EXTREME-ULTRAVIOLET EMISSION LINES OF Fe VII, Fe VIII, AND Fe IX OBSERVED BY HINODE/EIS

A detailed study of emission lines from Fe VII, Fe VIII, and Fe IX observed by the EUV Imaging Spectrometer on board the Hinode satellite is presented. Spectra in the ranges 170-212 A and 246-292 A show strongly enhanced lines from the upper solar transition region (temperatures 5.4 <= log T <= 5.9) allowing a number of new line identifications to be made. Comparisons of Fe VII lines with predictions from a new atomic model reveal new plasma diagnostics, however there are a number of disagreements between theory and observation for emission line ratios insensitive to density and temperature, suggesting improved atomic data are required. Line ratios for Fe VIII also show discrepancies with theory, with the strong lambda185.21 and lambda186.60 lines underestimated by 60%-80% compared to lines between 192 and 198 A. A newly identified multiplet between 253.9 and 255.8 A offers excellent temperature diagnostic opportunities relative to the lines between 185 and 198 A, however the atomic model underestimates the strength of these lines by factors of 3-6. Two new line identifications are made for Fe IX at wavelengths 176.959 A and 177.594 A, while seven other lines between 186 and 200 A are suggested to be due to Fe IX but for which transition identifications cannot be made. The new atomic data for Fe VII and Fe IX are demonstrated to significantly modify models for the response function of the Transition Region And Coronal Explorer 195 A imaging channel, affecting temperature determinations from this channel. The data will also affect the response functions for other solar EUV imaging instruments such as SOHO/EIT, STEREO/EUVI, and the upcoming AIA instrument on the Solar Dynamics Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗