Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

An Optical Streak Diagnostic for Observing Anode-Cathode Plasmas for Radiographic Source Development

National Security Technologies, LLC, and Sandia National Laboratories are collaborating in the development of pulsed power–driven flash x-ray radiographic sources that utilize high-intensity electron beam diodes. The RITS 6 (Radiographic Integrated Test Stand) accelerator at Sandia is used to drive a self magnetic pinch diode to produce a Bremsstrahlung x-ray source. The high electric fields and current densities associated with these short A-K gap pinch beam diodes present many challenges in diode development. Plasmas generated at both the anode and cathode affect the diode performance, which is manifested in varying spot (source) sizes, total dose output, and impedance profiles. Understanding the nature of these plasmas including closure rates and densities is important in modeling their behavior and providing insight into their mitigation. In this paper we describe a streak camera–based optical diagnostic that is capable of observing and measuring plasma evolution within the A-K gap. By imaging a region of interest onto the input slit of a streak camera, we are able to produce a time-resolved one-dimensional image of the evolving plasma. Typical data are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated Diagnostic and Prognostic Tools for Residual Life Estimation in Aging Nuclear Power Plant Components

Recent events in Japan have focused renewed attention on the safe operation of light water reactor (LWR) nuclear power plants (NPPs). A central issue in safe, long-term operations of existing and planned NPPs is the early detection and monitoring of significant materials degradation. Materials aging and degradation in passive components is expected to be the key factor in determining the operational life of an NPP and may limit long-term operations in the current LWR fleet. Methods for detecting and assessing the degradation state in NPP structural materials, followed by approaches to estimate the remaining useful life (RUL) of the component, are therefore necessary for safe, long-term operations. This paper explores advanced diagnostic and prognostic approaches to detecting material degradation, and then determining RUL given the current material state.

Advanced Diagnostics↗

NONEQUILIBRIUM LASER SYNTHESIS AND REAL-TIME DIAGNOSTICS OF CARBON NANOMATERIAL GROWTH

Lasers provide unique growth conditions for the synthesis of novel nanomaterials. In addition, they can serve as remote spectroscopic probes of the growth environment. Ultimately, through the process understanding they provide, real-time laser diagnostics that can be used to control the nanomanufacturing of nanomaterials. Here, progress in the laser-based synthesis and investigations of carbon nanomaterial growth kinetics will be reviewed with an emphasis on single-wall carbon nanotubes (SWNTs), single-wall carbon nanohorns (SWNHs), and graphene. Two synthesis methods will be compared. First, the unique high-temperature growth environment of a laser plasma will be examined using time-resolved imaging and laser spectroscopy to understand how pure carbon can self-assemble rapidly into a variety of forms including SWNHs and graphene flakes, and with catalyst-assistance, SWNTs. Atomic resolution images of SWNTs, SWNHs, and graphene reveals that graphene flakes are likely building blocks for the growth of these materials. Second, lower-temperature, chemical vapor deposition (CVD) methods suitable for mass production of nanomaterials will be examined. Pulsed-CVD and pulsed laser deposition (PLD) are described to investigate the catalyst-assisted growth kinetics of graphene and SWNTs. Time-resolved laser reflectivity and Raman spectroscopy studies show that autocatalytic kinetics imply the existence of intermediates crucial to the efficient nanomanufacturing of these materials for energy applications.

graphene↗

Diagnostic Models for Wind Turbine Gearbox Components Using SCADA Time Series Data: Preprint

This paper presents a scalable, autonomous framework for diagnostics of wind turbine gearbox failures using a multi-feature supervisory control and data acquisition data set spanning multiple years. Because of the size of the data set studied, all algorithms were constructed to be scalable using a Spark-Hadoop data framework. An unsupervised approach was used to detect significant failures based on predetermined criteria. The initial criteria selected were an abnormal spike in turbine component temperature followed by a turbine power off, which helps reduce the number of potential false alarms. To detect abnormal spikes in component temperature, a model was introduced to adjust the temperature data for effects caused by ambient temperature and normal temperature increases when loaded. This study evaluates methods for normalizing temperature sensor data to identify anomalies. The models that performed the best were a linear regression and a multivariate polynomial regression. The proposed process for finding failures has tunable parameters that can be adjusted to be more or less sensitive. The combination of sensor data normalization and application of these criteria is successful in finding turbine failures resulting in downtime. The proposed methods can operate without failure or maintenance logs and can be utilized for offline analysis of large high-resolution data sets.

17 WIND ENERGY↗

All-Digital Time-Resolved Spot Diagnostic

Presentation describes research into construction of a time-resolved spot diagnostic using mostly commercial off-the-shelf components, with system requirements to include (among others) comparable or better signal-to-noise ratio than a streak camera; low-loss fiber network, likely less than a few dB; optimized interface to the scintillators; and fast detectors to capture the pulse shape, 500 MHz to 1 GHz analog bandwidth with good linearity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Bunch Length Diagnostic, Phase I. Interim report

We Report Progress to date in the development of a Novel Bunch Length Diagnostic which uniquely uses the spatial profile of coherent transition radiation or coherent diffraction radiation to measure the root mean square average bunch length of an electron beam produced by an accelerator. This new technique can potentially be applied to a wide variety of accelerators and is simple and straightforward to use.

43 PARTICLE ACCELERATORS↗

Lithium-Ion Battery Diagnostics Using Electrochemical Impedance via Machine-Learning

Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.

battery↗

Design Aspects of the Emittance Diagnostic for the Scorpius Accelerator

Dear author, This is a reminder that we are expecting you to resubmit your IPAC'23 paper 1268 at https://indico.jacow.org/event/41/papers/2549/ in a format compliant with the IoP guidelines posted at https://publishingsupport.iopscience.iop.org/author-guidelines-for-conference-proceedings/ Could you please upload your paper as a PDF file in the IoP format at https://indico.jacow.org/event/41/papers/2549/ Title: The Design of the Emittance Diagnostic for the Scorpius Accelerator id: 1268 The deadline for resubmitting your paper is July 1st 2023 but we would appreciate if you could submit it earlier. Thank you in advance, Nicolas Delerue on behalf of the IPAC'23 LPR SPB

43 PARTICLE ACCELERATORS↗

Plasma/Wall interaction of an insulated material by laser-induced fluorescence diagnostic

We present Argon Ion Velocity Distribution Function (IVDF) in the vicinity of an insulated BNSiO{sub 2} ceramic and a glass plate in a non magnetized plasma by laser-induced fluorescence diagnostic. Results show the rather surprising self-consistent formation of a positive or inverse sheath in the two cases. The positive plasma potential repels ions from the insulated wall and is not explained by any sheath theory. Electron secondary emission of the ceramic can be a good candidate to explain these results. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic Components in Harsh Radiation Environments: Possible Overlap in R&D Requirements of IC and MF Systems

The next generation of large scale fusion devices--ITER/LMJ/NIF--will require diagnostic components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiation, and in some cases debris and shrapnel, at levels several orders of magnitude higher than those experienced in today's devices. For several years the question of possible synergy between inertial and the magnetic confinement research has been pursued by members of the respective communities. A first joint workshop specifically devoted to the identification and promotion of these synergies was organized in France, at Aix-en-Provence from June 27th to 29th, 2007. The workshop was attended by about 50 invited specialists. The participants identified a number of subject areas where common overlapping interests could benefit from additional interactions and meetings: windows, optical fibers, mirrors, cables, electronic components and 14 MeV neutron sources. In this paper we summarize the findings of these working groups. We put the discussion into context by including a brief description of the environments and the physical effects that have to be handled.

42 ENGINEERING↗

Diagnostics for the Biased Electrode Experiment on NSTX

A linear array of four small biased electrodes was installed in NSTX in an attempt to control the width of the scrape-off layer (SOL) by creating a strong local poloidal electric field. The set of electrodes were separated poloidally by a 1 cm gap between electrodes and were located slightly below the midplane of NSTX, 1 cm behind the RF antenna and oriented so that each electrode is facing approximately normal to the magnetic field. Each electrode can be independently biased to ±100 volts. Present power supplies limit the current on two electrodes to 30 amps the other two to 10 amps each. The effect of local biasing was measured with a set of Langmuir probes placed between the electrodes and another set extending radially outward from the electrodes, and also by the gas puff imaging diagnostic (GPI) located 1 m away along the magnetic field lines intersecting the electrodes. Two fast cameras were also aimed directly at the electrode array. The hardware and controls of the biasing experiment will be presented and the initial effects on local plasma parameters will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data and Analysis from a Time-Resolved Tomographic Optical Beam Diagnostic

An optical tomographic diagnostic instrument developed for the acquisition of high-speed time-resolved images has been fielded at the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility at Los Alamos National Laboratory. The instrument was developed for the creation of time histories of electron-beam cross section through the collection of Cerenkov light. Four optical lines of sight optically collapse an image and relay projections via an optical fiber relay to recording instruments; a tomographic reconstruction algorithm creates the time history. Because the instrument may be operated in an adverse environment, it may be operated, adjusted, and calibrated remotely. The instrument was operated over the course of various activities during and after DARHT commissioning, and tomographic reconstructions reported verifiable beam characteristics. Results from the collected data and reconstructions and analysis of the data are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extinction Imaging Diagnostics for In Situ Quantification of Soot within Explosively Generated Fireballs

Fireballs produced from the detonation of high explosives often contain particulates primarily composed of various phases of carbon soot. The transport and concentration of these particulates is of interest for model validation and emission characterization. Here, this work proposes ultra-high-speed imaging techniques to observe a fireball's structure and optical depth. An extinction-based diagnostic applied at two wavelengths indicates that extinction scales inversely with wavelength, consistent with particles in the Rayleigh limit and dimensionless extinction coefficients which are independent of wavelength. Within current confidence bounds, the extinction-derived soot mass concentrations agree with expectations based upon literature reported soot yields. Results also identify areas of high uncertainty where additional work is recommended.

33 ADVANCED PROPULSION SYSTEMS↗

Diagnostic accuracy of MRI with extracellular vs. hepatobiliary contrast material for detection of residual hepatocellular carcinoma after locoregional treatment

Purpose: To compare the diagnostic accuracy of extracellular gadolinium-based contrast-enhanced MRI (Gd-MRI) and gadoxetic acid-enhanced MRI (EOB-MRI) for the assessment of hepatocellular carcinoma (HCC) response to locoregional therapy (LRT) using explant correlation as the reference standard. Methods: Forty-nine subjects with cirrhosis and HCC treated with LRT who underwent liver MRI using either Gd-MRI (n = 26) or EOB-MRI (n = 23) within 90 days of liver transplantation were included. Four radiologists reviewed the MR images blinded to histology to determine the size and percentage of viable residual HCC using a per-lesion explant reference standard. Sensitivities, specificities, accuracies, and agreement with histology for the detection residual HCC were calculated. Results: Gd-MRI had greater agreement with histology (ICC: 0.98 [0.95–0.99] vs. 0.80 [0.63–0.90]) and greater sensitivity for viable HCC (76% [13/17 50–93%] vs. 58% [7/12; 28–85%]) than EOB-MRI; specificities were similar (84% [16/19; 60–97%] vs. 85% [23/27; 66–96%]). Areas under ROC curves for detecting residual viable tumor were 0.80 (0.64–0.92) for Gd-MRI and 0.72 (0.55–0.85) for EOB-MRI. Gd-MRI had greater inter-rater agreement than EOB-MRI for determining the size of residual viable HCC (ICC: 0.96 [0.92–0.98] vs. 0.85 [0.72–0.92]). Conclusion: Gd-MRI may be more accurate and precise than EOB-MRI for the assessment of viable HCC following LRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostic performance of magnetic resonance to assess treatment response after neoadjuvant therapy in patients with locally advanced rectal cancer

Purpose: Our study aimed to evaluate the diagnostic performance of rectal magnetic resonance imaging (MRI) for local restaging in patients with non-metastatic locally advanced rectal cancer (LARC) after neoadjuvant chemoradiotherapy (CRT) using surgical histopathology of total mesorectal excision as the reference standard. Methods: Ninety-five patients with LARC who underwent rectal MRI after CRT between January 2014 and December 2016 were included. Accuracy, sensitivity, specificity, positive, and negative predictive value for local staging regarding T-stage, N-stage, circumferential resection margin, and MRI tumor regression grade (ymriTRG) were calculated, and inter-test agreements were assessed. Results: 22/95 (23.2%) patients had radiological complete response (rCR), whereas 20/95 (21.1%) had pathological complete response (pCR). Among the patients with pCR, 11/20 (55%) had rCR. Fair agreement was demonstrated between ymriTRG and pathological TRG (ypTRG) (κ = 0.255). The sensitivity and specificity for detection of pCR were 61.1% (95% CI 35.7–82.7) and 89.6% (95% CI 80.6–95.4). For the detection of ypTRG grades 1 and 2, the corresponding values were 67.2% (95% CI 54.3–78.4) and 51.6 (95% CI 33.1–69.8). The accuracy of ymriTRG was 24.2% (95% CI 15.6–32.8). Inter-test agreement in TRG between MRI and pathology was overall fair (κ = 0.255) and slight (κ = 0.179), if TRG 1 + 2. Conclusion: Qualitative assessment on MRI for diagnosing pCR showed moderate sensitivity and high specificity, whereas the diagnosis of TRG had moderate sensitivity and low specificity with slight to fair inter-test agreement when compared with pathological specimens.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chronic Pelvic Pain due to Pelvic Congestion Syndrome: The Role of Diagnostic and Interventional Radiology

Chronic pelvic pain (CPP) is a common cause of gynecologic referral. Pelvic congestion syndrome, which is said to occurs due to ovarian vein incompetence, is a recognized cause of CPP. The aim of this paper is to briefly describe the clinical manifestations, and to review the role of diagnostic and interventional radiology in the management of this probably under-diagnosed condition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗