Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Effects of magnetic fields on HPGe tracking detectors

Here, we present a study of magnetic fields effects on the position resolution and energy response of hyper-pure germanium detectors. Our results provide realistic estimates of the potential impact on the resolving power of tracking-arrays from (fringe) magnetic fields present when operating together with large spectrometers. By solving the equations of motion for the electron and holes in the presence of both electric and magnetic fields, we analyzed the drift trajectories of the charge carriers to determine the deviations in the positions at the end point of the trajectories, as well as changes in drift lengths affecting the energy resolution and peak shift due to trapping. Our results show that the major effect is in the deviation of the transverse (to the electric field direction) position and suggest that, if no corrective action is taken in the pulse-shape and tracking data analysis procedures, a field strength ≳ 0.1 T will start to impact the intrinsic position resolution of 2 mm (RMS). At fields above ~1 T, the degradation of the energy response becomes observable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

135 Xe measurements with a two-element CZT-based radioxenon detector for nuclear explosion monitoring

Measurement of elevated concentrations of xenon radioisotopes ( 131m Xe, 133m Xe, 133 Xe and 135 Xe) in the atmosphere has been shown to be a very powerful method for verifying whether or not a detected explosion is nuclear in nature. These isotopes are among the few with enough mobility and with half-lives long enough to make their detection at long distances realistic. Existing radioxenon detection systems used by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) suffer from problems such as complexity, need for high maintenance and memory effect. To study the response of CdZnTe (CZT) detectors to xenon radioisotopes and investigate whether it is capable of mitigating the afore-mentioned issues with the current radioxenon detection systems, a prototype detector utilizing two coplanar CZT detectors was built and tested at Oregon State University. The detection system measures xenon radioisotopes through beta-gamma coincidence technique by detecting coincidence events be-tween the two detectors. Here in this paper, we introduce the detector design and report our measurement results with radioactive lab sources and 135 Xe produced in the OSU TRIGA reactor. Minimum Detectable Concentration (MDC) for 135 Xe was calculated to be 1.47 ± 0.05 mBq/m 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New two-dimensional space-resolving flux detection technique for measurement of hohlraum inner radiation in Shenguang-III prototype

The space-resolving measurement of X-ray flux from a specific area (laser spot, re-emitting wall, or capsule) inside the hohlraum is an ongoing and critical problem in indirectly driven inertial-confinement fusion experiments. In this work, we developed a new two-dimensional space-resolving flux detection technique to measure the X-ray flux from specific areas inside the hohlraum by using the time- and space-resolving flux detector (SRFD). In two typical hohlraum experiments conducted at the Shenguang-III prototype laser facility, the X-ray flux and radiation temperature from an area 0.2 mm in diameter inside the hohlraum were measured through the laser entrance hole (LEH). The different flux intensities and radiation temperatures detected using the SRFD from the inner area of the LEH were compared with the result measured using the flat-response X-ray detector from the entire LEH. This comparison was also analyzed theoretically. The inner area detected using the SRFD was found to be the re-emitting wall area alone. This important improvement in space-resolving X-ray flux measurement will enhance the current X-ray flux space characterization techniques, thereby furthering the quantitative understanding of X-ray flux space behavior in the hohlraum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LL13-MatModelRadDetect-PD2Jf Final Report: Materials Modeling for High-Performance Radiation Detectors

The aims of this project are to enable rational materials design for select high-payoff challenges in radiation detection materials by using state-of-the-art predictive atomistic modeling techniques. Three specific high-impact challenges are addressed: (i) design and optimization of electrical contact stacks for TlBr detectors to stabilize temporal response at room-temperature; (ii) identification of chemical design principles of host glass materials for large-volume, low-cost, highperformance glass scintillators; and (iii) determination of the electrical impacts of dislocation networks in Cd 1-x Zn x Te (CZT) that limit its performance and usable single-crystal volume. The specific goals are to establish design and process strategies to achieve improved materials for high performance detectors. Each of the major tasks is discussed below in three sections, which include the goals for the task and a summary of the major results, followed by a listing of publications that contain the full details, including details of the methodologies used. The appendix lists 12 conference presentations given for this project, including 1 invited talk and 1 invited poster.

36 MATERIALS SCIENCE↗

D-T gamma-to-neutron branching ratio determined from inertial confinement fusion plasmas

A new deuterium-tritium (D-T) fusion gamma-to-neutron branching ratio [{sup 3}H(d,{gamma}){sup 5}He/{sup 3}H(d,n){sup 4}He] value of (4.2 {+-} 2.0) Multiplication-Sign 10{sup -5} was recently reported by this group [Y. Kim et al. Phys. Rev. C (submitted)]. This measurement, conducted at the OMEGA laser facility located at the University of Rochester, was made for the first time using inertial confinement fusion (ICF) plasmas. Neutron-induced backgrounds are significantly reduced in these experiments as compared to traditional beam-target accelerator-based experiments due to the short pulse nature of ICF implosions and the use of gas Cherenkov {gamma}-ray detectors with fast temporal responses and inherent energy thresholds. It is expected that this ICF-based measurement will help resolve the large and long-standing inconsistencies in previously reported accelerator-based values, which vary by a factor of approximately 30. The reported value at ICF conditions was determined by averaging the results of two methods: (1) a direct measurement of ICF D-T {gamma}-ray and neutron emissions using absolutely calibrated detectors and (2) a separate cross-calibration against the better known D-{sup 3}He gamma-to-proton branching ratio [{sup 3}He(d, {gamma}){sup 5}Li/{sup 3}He(d,p){sup 4}He]. Here we include a detailed explanation of these results, and introduce as a corroborative method an in-situ{gamma}-ray detector calibration using neutron-induced {gamma}-rays. Also, by extending the established techniques to two additional series of implosions with significantly different ion temperatures, we test the branching ratio dependence on ion temperature. The data show a D-T branching ratio is nearly constant over the temperature range 2-9 keV. These studies motivate further investigation into the {sup 5}He and {sup 5}Li systems resulting from D-T and D-{sup 3}He fusion, respectively, and result in improved ICF {gamma}-ray reaction history diagnosis at the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Collaborative Research Initiatives to Advance the Aerospace Sciences-via the Communications, Electronics, Information Systems Focus Group

The primary goal of the Adaptive Vision Laboratory Research project was to develop advanced computer vision systems for automatic target recognition. The approach used in this effort combined several machine learning paradigms including evolutionary learning algorithms, neural networks, and adaptive clustering techniques to develop the E-MOR.PH system. This system is capable of generating pattern recognition systems to solve a wide variety of complex recognition tasks. A series of simulation experiments were conducted using E-MORPH to solve problems in OCR, military target recognition, industrial inspection, and medical image analysis. The bulk of the funds provided through this grant were used to purchase computer hardware and software to support these computationally intensive simulations. The payoff from this effort is the reduced need for human involvement in the design and implementation of recognition systems. We have shown that the techniques used in E-MORPH are generic and readily transition to other problem domains. Specifically, E-MORPH is multi-phase evolutionary leaming system that evolves cooperative sets of features detectors and combines their response using an adaptive classifier to form a complete pattern recognition system. The system can operate on binary or grayscale images. In our most recent experiments, we used multi-resolution images that are formed by applying a Gabor wavelet transform to a set of grayscale input images. To begin the leaming process, candidate chips are extracted from the multi-resolution images to form a training set and a test set. A population of detector sets is randomly initialized to start the evolutionary process. Using a combination of evolutionary programming and genetic algorithms, the feature detectors are enhanced to solve a recognition problem. The design of E-MORPH and recognition results for a complex problem in medical image analysis are described at the end of this report. The specific task involves the identification of vertebrae in x-ray images of human spinal columns. This problem is extremely challenging because the individual vertebra exhibit variation in shape, scale, orientation, and contrast. E-MORPH generated several accurate recognition systems to solve this task. This dual use of this ATR technology clearly demonstrates the flexibility and power of our approach.

Knasel, T. Michael↗

Development of a 83 mKr source for the calibration of the CENNS-10 liquid argon detector

We report on the preparation of and calibration measurements with a 83 mKr source for the CENNS-10 liquid argon detector. 83 mKr atoms generated in the decay of a 83 Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of 83 mKr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9% at the total 83 mKr decay energy of 41.5 keV. Lastly, we performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV.

47 OTHER INSTRUMENTATION↗

Analytical expressions for the gate utilization factors of passive multiplicity counters including signal build-up

In the realm of nuclear safeguards, passive neutron multiplicity counting using shift register pulse train analysis to nondestructively quantify Pu in product materials is a familiar and widely applied technique. The approach most commonly taken is to construct a neutron detector consisting of {sup 3}He filled cylindrical proportional counters embedded in a high density polyethylene moderator. Fast neutrons from the item enter the moderator and are quickly slowed down, on timescales of the order of 1-2 {micro}s, creating a thermal population which then persists typically for several 10's {micro}s and is sampled by the {sup 3}He detectors. Because the initial transient is of comparatively short duration it has been traditional to treat it as instantaneous and furthermore to approximate the subsequent capture time distribution as exponential in shape. With these approximations simple expressions for the various Gate Utilization Factors (GUFs) can be obtained. These factors represent the proportion of time correlated events i.e. Doubles and Triples signal present in the pulse train that is detected by the coincidence gate structure chosen (predelay and gate width settings of the multiplicity shift register). More complicated expressions can be derived by generalizing the capture time distribution to multiple time components or harmonics typically present in real systems. When it comes to applying passive neutron multiplicity methods to extremely intense (i.e. high emission rate and highly multiplying) neutron sources there is a drive to use detector types with very fast response characteristics in order to cope with the high rates. In addition to short pulse width, detectors with a short capture time profile are also desirable so that a short coincidence gate width can be set in order to reduce the chance or Accidental coincidence signal. In extreme cases, such as might be realized using boron loaded scintillators, the dieaway time may be so short that the build-up (thermalization transient) within the detector cannot be ignored. Another example where signal build-up might be observed is when a {sup 3}He based system is used to track the evolution of the time correlated signal created by a higher multiplying item within a reflective configuration such as the measurement of a spent fuel assembly. In this work we develop expressions for the GUFs which include signal build-up.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-328: The Volume Effect Correction of Probe-Type Dosimetric Detectors Derived From the Convolution Model

Purpose: To derive and introduce a new correction factor kV, the “volume effect correction factor”, that accounts for not only the dose averaging over the detector's sensitive volume but also the secondary electron generation and transport inclusive of the disturbance of the field of secondary electrons within the detector. Materials and Methods: Mathematical convolutions and Fourier's convolution theorem have been used. Monte Carlo simulations of photon pencil beams were performed using EGSnrc. Detector constructions were adapted from manufacturers' information. Results: For the calculation of kV, the three basic convolution kernels have to be taken into account: the dose deposition kernel KD(x) (fluence to dose), the photon fluence response kernel KM(x) (photon fluence to detector signal) and the “dose response kernel” K(x) (dose to detector signal). K(x) is calculated from FT[K(x)] = [1/sqrt(2”)]FT[KM(x)]/FT[KD(x)], where the magnitude of kV(x) can be thereby calculated for arbitrary photon beam profiles and the areanormalized K(x). Conclusions: n order to take into account for the dimensions of dosimetric detectors in narrow photon beams, the “volume effect correction factor” kV has been introduced into the fundamental equation of probe-type dosimetry, and the convolution method has proven to be a method for the derivation of its numerical values. For narrow photon beams, whose width is comparable to the secondary electron ranges, kV can reach very high values, but it can be shown that the signals of small diamond detectors are well representing the absorbed dose to water averaged over the detector volume.

07 ISOTOPE AND RADIATION SOURCES↗

Thermal IR imaging system using a self-scanned HgCdTe/CCD detector array

It is likely that future high resolution earth observation imaging systems will utilize self-scanned IR detectors. In an initial step toward this goal, an IR imaging system operating in the 10 to 12 micron spectral region has been developed. This system uses a 9-element HgCdTe/CCD linear array operating in the photoconductive mode, nine pre-amplifiers and a silicon CCD multiplexer integrated into a focal plane assembly. Opto-mechanical techniques are used to scan the scene and images are produced in real time. The imaging performance of this system is described and measurements of noise, responsivity, specific detectivity, and detector sensitivity profiles are presented. The requirements for more advanced detector arrays for use in future NASA remote sensing missions are also discussed.

Husain-Abidi, A. S.↗

Fast, Large-Area, Wide-Bandgap UV Photodetector for Cherenkov Light Detection

Due to limited resources available for power and space for payloads, miniaturizing and integrating instrumentation is a high priority for addressing the challenges of manned and unmanned deep space missions to high Earth orbit (HEO), near Earth objects (NEOs), Lunar and Martian orbits and surfaces, and outer planetary systems, as well as improvements to high-altitude aircraft safety. New, robust, and compact detectors allow future instrumentation packages more options in satisfying specific mission goals. A solid-state ultraviolet (UV) detector was developed with a theoretical fast response time and large detection area intended for application to Cherenkov detectors. The detector is based on the wide-bandgap semiconductor zinc oxide (ZnO), which in a bridge circuit can detect small, fast pulses of UV light like those required for Cherenkov detectors. The goal is to replace the role of photomultiplier tubes in Cherenkov detectors with these solid-state devices, saving on size, weight, and required power. For improving detection geometry, a spherical detector to measure high atomic number and energy (HZE) ions from any direction has been patented as part of a larger space radiation detector system. The detector will require the development of solid-state UV photodetectors fast enough (2 ns response time or better) to detect the shockwave of Cherenkov light emitted as the ions pass through a quartz, sapphire, or acrylic ball. The detector must be small enough to fit in the detector system structure, but have an active area large enough to capture enough Cherenkov light from the sphere. The detector is fabricated on bulk single-crystal undoped ZnO. Inter - digitated finger electrodes and contact pads are patterned via photolithography, and formed by sputtered metal of silver, platinum, or other high-conductivity metal.

Wrbanek, John D.↗

Position sensitive detection of neutrons in high radiation background field

We present the development of a high-resolution position sensitive device for detection of slow neutrons in the environment of extremely high γ and e{sup −} radiation background. We make use of a planar silicon pixelated (pixel size: 55 × 55 μm{sup 2}) spectroscopic Timepix detector adapted for neutron detection utilizing very thin {sup 10}B converter placed onto detector surface. We demonstrate that electromagnetic radiation background can be discriminated from the neutron signal utilizing the fact that each particle type produces characteristic ionization tracks in the pixelated detector. Particular tracks can be distinguished by their 2D shape (in the detector plane) and spectroscopic response using single event analysis. A Cd sheet served as thermal neutron stopper as well as intensive source of gamma rays and energetic electrons. Highly efficient discrimination was successful even at very low neutron to electromagnetic background ratio about 10{sup −4}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical calibration of the SNO+ detector in the water phase with deployed sources

SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. Finally, the calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.

47 OTHER INSTRUMENTATION↗

Measurement of the directional sensitivity of Dark Matter Time Projection Chamber detectors

The dark matter time projection chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling 19 F and 12 C nuclei in low-pressure CF 4 gas using optical and charge readout systems. In this paper, we employ measurements from two DMTPC detectors, with operating pressures of 30–60 torr, to develop and validate a model of the directional response and performance of such detectors as a function of recoil energy. Using our model as a benchmark, we formulate the necessary specifications for a scalable directional detector with sensitivity comparable to that of current-generation counting (nondirectional) experiments, which measure only recoil energy. Furthermore assuming the performance of existing DMTPC detectors, as well as current limits on the spin-dependent WIMP-nucleus cross section, we find that a 10–20 kg scale direction-sensitive detector is capable of correlating the measured direction of nuclear recoils with the predicted direction of incident dark matter particles and providing decisive (3σ) confirmation that a candidate signal from a nondirectional experiment was indeed induced by elastic scattering of dark matter particles off of target nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of neutron spectra generated from bombardment of 4 to 24 MeV protons on a thick {sup 9}Be target and estimation of neutron yields

A systematic study on the measurement of neutron spectra emitted from the interaction of protons of various energies with a thick beryllium target has been carried out. The measurements were carried out in the forward direction (at 0° with respect to the direction of protons) using CR-39 detectors. The doses were estimated using the in-house image analyzing program autoTRAK-n, which works on the principle of luminosity variation in and around the track boundaries. A total of six different proton energies starting from 4 MeV to 24 MeV with an energy gap of 4 MeV were chosen for the study of the neutron yields and the estimation of doses. Nearly, 92% of the recoil tracks developed after chemical etching were circular in nature, but the size distributions of the recoil tracks were not found to be linearly dependent on the projectile energy. The neutron yield and dose values were found to be increasing linearly with increasing projectile energies. The response of CR-39 detector was also investigated at different beam currents at two different proton energies. A linear increase of neutron yield with beam current was observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of energy partitioning on electron-hole recombination, trapping, and detection in silicon detectors

The dynamics of electron-hole pair creation and transport in a semiconductor control the fundamental signal response for radiation detection. Extensive studies on silicon detectors have led to contradictory interpretations on the origins of the pulse height defect (PHD) and nonlinear response. In this study, recombination and trapping behaviors of a controlled number of electron-hole pairs produced within different volumes along the ion path are investigated, and the pulse height generated is analyzed in terms of energy partitioning. The results clearly demonstrate that a high recombination rate is not observed for heavy ions; moreover, significant trapping associated with the atomic defects produced by individual ions is responsible for the nonlinear response at low energies and PHD at high energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GeSn p-i-n waveguide photodetectors on silicon substrates

We report an investigation on GeSn p-i-n waveguide photodetectors grown on a Ge-buffered Si wafer. In comparison with a reference Ge detector, the GeSn detector shows an enhanced responsivity in the measured energy range, mainly attributed to the smaller bandgap caused by Sn-alloying. Analysis of the quantum efficiency indicates that increasing the Sn content in the active layers can significantly shorten the required device length to achieve the maximum efficiency. The present investigation demonstrates the planar photodetectors desired for monolithic integration with electronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗