At least 1,531 records · Page 85

Decarbonization of heat pump dual fuel systems using a practical model predictive control: Field demonstration in a small commercial building

In the transition from fossil fuel to electrified heating, a concerning trend is emerging in certain regions of the US. Owners of buildings with gas-based systems leave them in place after adding heat pumps (HPs). Existing control solutions for these hybrid (dual fuel) systems are rudimentary and fall short of realizing the full carbon reduction potential of these systems. Model predictive control (MPC) is often regarded as the benchmark for achieving optimal control in integrated systems. However, in the case of small-medium commercial buildings (SMCBs), the control and communication infrastructure required to facilitate the implementation of such advanced controls is often lacking. This paper presents a field implementation of easy-to-deploy MPC for a dual fuel heating system consisting of HPs and a gas-fired furnace (GF) for SMCBs. The control system is deployed on an open-source middleware platform and utilizes low-cost sensor devices to be used for real SMCBs without major retrofits. Here, we demonstrated this MPC in a real office building with 5 HPs and 1 GF for 2 months. The test results showed that MPC reduced 27% of cost while completely eliminating GF usage by shifting 23% of the thermal load from occupied-peak time to non-occupied-non-peak times.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Demonstration of gold nanorod systems for enhanced total efficiency: Experimental and numerical analysis

This study investigates the photothermal performance of gold nanorods engineered to exhibit longitudinal plasmon resonances at 695 nm, 780 nm, and 970 nm. The work combines synthesis, structural characterization, extinction measurements, numerical modeling, and controlled temperature experiments to quantify how nanorod geometry, resonance tuning, concentration, and chamber shape jointly influence heat generation. Transmission electron microscopy confirms that increasing nanorod aspect ratio systematically shifts the longitudinal plasmon peak toward the near-infrared region. Extinction measurements show strong agreement with theoretical predictions, validating the numerical model across two independent datasets. Three chamber geometries were tested under laser excitation at 640 nm, 808 nm, and 980 nm: an ascending stepped base, a flat base, and a descending stepped base. Without nanorods, the ascending geometry produced the highest efficiency due to enhanced natural convection. After introducing gold nanorods, all geometries exhibited substantial thermal enhancement, with total efficiencies exceeding 20%. The strongest improvement was obtained for nanorods resonant at 780 nm with a mass concentration of 4.6 mg/mL implemented on the descending stepped-base geometry. This performance resulted from the combined effect of spectral overlapping with the 808 nm laser, the highest nanorod concentration, and localized heat accumulation that intensified buoyancy-driven flow. The findings demonstrate that total efficiency is governed by a synergistic interplay between optical resonance, nanoparticle concentration, and macroscopic chamber design, revealing the system-level coupling between nanoscale plasmonic absorption and macroscale heat-transfer phenomena. The results provide a validated framework for tuning nanoscale plasmonic absorbers and optimizing thermal systems for applications requiring efficient light-to-heat conversion.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Saponin fraction isolated from Conyza blinii H.Lév. demonstrates strong anti-cancer activity that is due to its NF-κB inhibition

CBS (Conyza blinii saponin) is the total triterpenoidal saponins of Conyza blinii H.Lév which is a type of traditional Chinese medicine (TCM). We have discovered that CBS has a profound cytostatic activity against a range of solid tumour cells in a time- and dose-dependent manner. We also confirm that the cytostatic activity of CBS originates from its apoptosis induction effect. Additionally, we use immunoblot to find out that the apoptosis induction effect of CBS is attributable to the activation of mitochondrial pathway. Mechanistic study demonstrates that CBS is an effective NF-κB inhibitor. It inhibits p65 nuclear translocation and NF-κB downstream gene expression, including XIAP, survivin, Bcl-xL, COX-2, cyclin D1, MMP-2, MMP-9 in HeLa cells. Tumour xenografted animal models verify the anti-cancer efficacy in vivo. Tumour growth is significantly repressed in two CBS-treated groups compared with the controls (P < 0.001). CBS treatment (i.g.) leads to a 48.5% and 57.0% reduction in terms of tumour weight for the 10 and 20 mg/kg dosed groups respectively. Also no apparent observable adverse effects can be seen. These results suggest that CBS obliterate tumour, at least in part due to its NF-κB inhibition, which creates potential for CBS to be developed as a practical cancer treatment.

60 APPLIED LIFE SCIENCES↗

Characterization of human AlkB homolog 1 produced in mammalian cells and demonstration of mitochondrial dysfunction in ALKBH1-deficient cells

Highlights: • Mammalian produced ALKBH1 (ALKBH1{sub 293}) possesses m{sup 6}A demethylase and AP lyase activity. • ALKBH1{sub 293} forms an adduct with the 5′-product of the AP lyase reaction. • ALKBH1 localizes to the mitochondria in MSU1.1 and HEK293 cells. • ALKBH1-deficient cells exhibit mitochondrial dysfunction. Alkbh1 is a mammalian homolog of the Escherichia coli DNA repair enzyme AlkB, an Fe(II) and 2-oxoglutarate dependent dioxygenase that removes alkyl lesions from DNA bases. The human homolog ALKBH1 has been associated with six different enzymatic activities including DNA, mRNA, or tRNA hydroxylation, cleavage at abasic (AP) sites in DNA, as well as demethylation of histones. The reported cellular roles of this protein reflect the diverse enzymatic activities and include direct DNA repair, tRNA modification, and histone modification. We demonstrate that ALKBH1 produced in mammalian cells (ALKBH1{sub 293}) is similar to the protein produced in bacteria (ALKBH1{sub Ec}) with regard to its m{sup 6}A demethylase and AP lyase activities. In addition, we find that ALKBH1{sub 293} forms a covalent adduct with the 5′ product of the lyase product in a manner analogous to ALKBH1{sub Ec}. Localization and subcellular fractionation studies with the endogenous protein in two human cell strains confirm that ALKBH1 is primarily in the mitochondria. Two strains of CRISPR/Cas9-created ALKBH1-deficient HEK293 cells showed increases in mtDNA copy number and mitochondrial dysfunction as revealed by growth measurements and citrate synthase activity assays.

60 APPLIED LIFE SCIENCES↗

Demonstration of photoreactor platform for on-sun unassisted photoelectrochemical hydrogen generation with tandem III–V photoelectrodes

Photoelectrochemical (PEC) water splitting is a direct solar-driven technology that converts solar energy to storable chemical energy in the form of hydrogen. In addition to semiconductor and catalyst development for improved photoelectrodes, designing reactors for testing and operation of PEC systems under inherently dynamic outdoor solar illumination is necessary to further the commercial viability of PEC technology. Herein, we present a versatile photoreactor system mounted on a solar tracker for outdoor PEC testing and demonstrate unassisted PEC water splitting under real world on-sun conditions. GaInP 2 /GaAs tandem absorber photoelectrodes with a MoS 2 catalyst were fabricated and exhibit >8% solar-to-hydrogen efficiency. On-sun efficiency and stability of the photoelectrodes were characterized on both sunny and partly cloudy days with continuous monitoring of insolation and weather conditions. Furthermore, the versatile photoreactor and outdoor PEC testing capabilities and methods presented here can accelerate the development of other solar fuel generating systems and technologies.

solar fuels↗

Mobilization of trace metals from caprock and formation rocks at the Illinois Basin – Decatur Project demonstration site under geological carbon dioxide sequestration conditions

One concern for geologic CO 2 sequestration is the potential leakage of CO 2 or CO 2 -saturated brine containing trace metals into overlying aquifers, which poses the risk of adversely affecting underground sources of drinking water. In this work, rock and brine samples collected in the Illinois Basin – Decatur Project (IBDP), a large-scale geological CO 2 sequestration demonstration project in Decatur, Illinois, USA, as well as synthetic brine samples were used to understand the mobilization of trace metals as a result of CO 2 –rock–brine interactions under IBDP-specific conditions (50 °C and 20.6 MPa). Rock sample characterization indicated that, at the IBDP site, trace metal concentrations were greatest in cap rock samples from the Eau Claire Formation, compared with those from formations above and below this Formation. The natural brine samples collected from the Mt. Simon Sandstone reservoir were highly reducing and saline, with trace metal concentrations up to 680 times greater than the U.S. Environmental Protection Agency-prescribed drinking water standards. Batch leaching experiments indicated that both trace metal mobilization from rock and immobilization from the brine occurred when high-pressure CO 2 was introduced into the rock-brine system. The amounts of metals mobilized from the rock generally accounted for <5% of the total metals in the rock, but for some metals, including Ni, Pb, and Tl, up to 63% of the metals in the rock were mobilized to the brine. Leaching of trace metals into synthetic brines was different from that into the natural brine. The results of this study provided current information on the trace element sources and will help in risk simulations and experimental design to further evaluate potential impact of leakage on groundwater quality, which is important for future GCS projects to consider for monitoring and containment assurance purposes.

58 GEOSCIENCES↗

Testing and demonstration of model predictive control applied to a radiant slab cooling system in a building test facility

Radiant slab systems have the potential to significantly reduce energy consumption in buildings. However, control of radiant slab systems is challenging. Classical feedback control is inadequate due to the large thermal inertia of the systems and heuristic feed-forward control often leads to unacceptable indoor comfort and may not achieve the full energy savings potential. Model predictive control (MPC) is now attracting increasing interest in the building industry and holds promise for radiant systems. However, an often-cited barrier to its implementation in the building industry is the high computational cost and complexity relative to the feedback controls used in conventional systems. The objectives of this study were to (i) verify the correct operation of an open source MPC toolchain developed for radiant slab systems, and (ii) demonstrate its efficacy in a test facility. A matched pair of cells in the FLEXLAB building test facility at the Lawrence Berkeley National Laboratory was used in the study. The proposed MPC toolchain was implemented in one cell and the performance compared to that of the other cell, which used a conventional heuristic control strategy. Finally, the results showed that the simplified MPC approach applied in the toolchain worked as expected and realized energy savings over the conventional control strategy. The MPC yielded 42% chilled water pump power reduction and 16% cooling thermal energy savings, while maintaining equal or better indoor comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of the carbon capture with building make-up air unit

Building-integrated carbon capture technology has the potential to reduce the cost of CO 2 capture while improving indoor air quality (IAQ). To promote the adoption of CO 2 capture in a building environment, this study investigated the possibility of integrating carbon capture technology with an existing rooftop make-up air unit (MAU) system to trap CO 2 . Here, in this study, a modular compact CO 2 capture system containing amine-functionalized polymer fibers was examined. The system, which was installed at the exhaust of the MAU, captures CO 2 before it leaves the building to enter the atmosphere as a greenhouse gas. The demonstrated average amount of CO 2 captured was 1.1–1.4 mmol/g of adsorbent material. Techno-economic analysis (TEA) was further performed on the CO 2 capture system, considering material costs, energy costs, as well as transportation and regeneration costs. These results were then used to estimate the levelized cost per ton CO 2 captured (LCOC). To achieve LCOC below $\$$100/t-CO 2 , adsorbents should have working capacities of 4.9 t and 3 t-CO 2 /year for 5 years and 10 years of operation, respectively. In summary, this study highlights a viable path toward the decarbonization of the commercial buildings sector and provides quantitative performance and economic insight on the suitability of building-integrated carbon capture technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and field demonstration of residential air source integrated heat pump using a three-stage compressor

To promote decarbonization and all electrification at residential sectors, it is necessary to use air source heat pumps (ASHPs) to replace natural gas for space heating and water heating. ASHPs are widely utilized for residential space cooling, heating, and water heating due to their simplicity and cost-effectiveness. However, their performance can be compromised in cold climates, where they may experience reduced heating capacity. A multi-functional heat pump, using a single compressor, to meet all home space conditioning and water heating demands, is an emerging technology. To address this limitation, we have developed and demonstrated an air source integrated heat pump to fulfill comprehensive home comfort requirements. This system employs a three-stage compressor and a single set of heat exchangers and valves, optimizing functionality while minimizing costs. The performance of the developed system was rigorously evaluated in both laboratory and field settings. In laboratory conditions, the system achieved a Seasonal Energy Efficiency Ratio of 17.0 (average COP of 4.98) and a Heating Seasonal Performance Factor of 11.0 (3.22). Additionally, in its most efficient operational mode—combining space cooling and water heating—the unit attained a total energy efficiency exceeding 7.0 seasonal COP in the field and could heat a 189-liter tank of water in just 25 min. The field study corroborated the laboratory findings, validating the system’s performance in real-world conditions. Here, this integrated heat pump represents an ideal solution for decarbonizing homes in northern climates by providing efficient space heating and water heating, thereby replacing the need for natural gas.

Integrated heat pump↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

Toward more mechanistic representations of biogeochemical processes in river networks: Implementation and demonstration of a multiscale model

A recently introduced multiscale model for representing the effects of small-scale hyporheic-zone biogeochemical processes is extended from the reach scale to river network scales. The model uses advection-dispersion-reaction equations for the channel network and one-dimensional advection-reaction subgrid models for the hyporheic zone. We summarize implementation in the integrated surface/subsurface hydrology modeling system Amanzi-ATS. The extension uses topologically defined meshes to represent stream/river networks and associates a hyporheic subgrid model with each channel grid cell. Biogeochemical reaction modeling capability residing in community software is accessed through an application programming interface. The implementation is verified against independent numerical solutions on a single reach. Mesh convergence studies show that commonly used semi-distributed representations can introduce significant spatial discretization error. Denitrification of farm runoff in a subbasin of the Portage River Basin in Ohio, USA is used to demonstrate the general-purpose reactive transport capability.

54 ENVIRONMENTAL SCIENCES↗

ARC: A compact, high-field, fusion nuclear science facility and demonstration power plant with demountable magnets

The affordable, robust, compact (ARC) reactor is the product of a conceptual design study focused on reducing the size, cost, and complexity of a combined fusion nuclear science facility (FNSF) and demonstration fusion Pilot power plant. ARC is a ~200–250 MWe tokamak reactor with a major radius of 3.3 m, a minor radius of 1.1 m, and an on-axis magnetic field of 9.2 T. ARC has rare earth barium copper oxide (REBCO) superconducting toroidal field coils, which have joints to enable disassembly. This enables the vacuum vessel to be replaced quickly, mitigating first wall survivability concerns, and permits a single device to test many vacuum vessel designs and divertor materials. The design point has a plasma fusion gain of Q p ≈ 13.6, yet is fully non-inductive, with a modest bootstrap fraction of only ~63%. Thus ARC offers a high power gain with relatively large external control of the current profile. This highly attractive combination is enabled by the ~23 T peak field on coil achievable with newly available REBCO superconductor technology. External current drive is provided by two innovative inboard RF launchers using 25 MW of lower hybrid and 13.6 MW of ion cyclotron fast wave power. The concluding efficient current drive provides a robust, steady state core plasma far from disruptive limits. ARC uses an all-liquid blanket, consisting of low pressure, slowly flowing fluorine lithium beryllium (FLiBe) molten salt. The liquid blanket is low-risk technology and provides effective neutron moderation and shielding, excellent heat removal, and a tritium breeding ratio ≥ 1.1. The large temperature range over which FLiBe is liquid permits an output blanket temperature of 900 K, single phase fluid cooling, and a high efficiency helium Brayton cycle, which allows for net electricity generation when operating ARC as a Pilot power plant.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of RELAP5-3D for transient analysis of a dual coolant lead lithium fusion blanket concept

Our research aims to build a multiphysics framework for transient analysis of the Dual- Coolant Lead-Lithium (DCLL) blanket design of the proposed Fusion Nuclear Science Facility (FNSF) for all Onticipated Operational Occurrences (AOOs) using Reduced Order Models (ROMs). This paper presents an assessment of using RELAP5-3D for transient thermal-hydraulic blanket analysis of the DCLL design. Preliminary validation studies for the RELAP5-3D properties were conducted using a representative vertical flow loop model and a comparison study using experimental data from the thermal convection corrosion loops at ORNL. These studies inspected the thermal hydraulic response of Lead-Lithium Eutectic (PbLi) systems within the RELAP5-3D code; mainly pressure drop and heat transfer, as compared to analytical calculations and experimental data. The Magnetohydrodynamic (MHD) pressure drop effect for liquid metal under the effects of a uniform magnetic field was implemented into our models using an equivalent forms loss coefficient based on the phasic momentum equations. We verified our implementation of MHD pressure drop within RELAP5-3D using a systematic approach consisting of two studies. Models were developed to perform comparison studies based on experimental data from the Argonne Liquid metal EXperiment (ALEX) facility and the Magnetohydrodynamic PbLi Experiment (MaPLE) facility. Using the developed validation basis, we built a simplified DCLL channel model within RELAP5-3D, inspected MHD pressure drop and performed transient temperature analysis. The DCLL channel model used radial heating data from the International Thermonuclear Experimental Reactor (ITER) which was normalized to the FNSF design. Here, a representative startup transient was performed using a relative power curve from the initial ramp up of a long-term power pulse of the Tore Supra reactor. This study demonstrated that RELAP5-3D ROMs are capable of accurate transient analysis of the DCLL blanket. We have since utilized MCNP to develop heating profiles based on the FNSF design and are working toward implementing them into our DCLL model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Northwest Geysers EGS Demonstration Project, California

Our project goal is to demonstrate the feasibility of stimulating a deep high-temperature reservoir (HTR) (up to 400 °C, 750 °F). There were two previously abandoned wells, Prati State 31 (PS-31) and Prati 32 (P-32), reopened and deepened to be used as an injection and production doublet to stimulate the HTR. The deepened portions of both wells have conductive temperature gradients of 10 °F/100 ft (182 °C/km), produce connate native fluids and magmatic gas, and the rocks were isotopically unexchanged by meteoric water. The ambient temperature meteoric water injected into these hot dry rocks has evidently created a permeability volume of several cubic kilometers as determined by seismic monitoring. Preliminary isotopic analyses of the injected and produced water indicate that 50–75% of the steam from the created EGS reservoir is injection-derived.

15 GEOTHERMAL ENERGY↗

Demonstration of space-resolved x-ray Thomson scattering capability for warm dense matter experiments on the Z accelerator

Experiments on the Sandia Z pulsed-power accelerator demonstrated the ability to produce warm dense matter (WDM) states with unprecedented uniformity, duration, and size, which are ideal for investigations of fundamental WDM properties. For the first time, space-resolved x-ray Thomson scattering (XRTS) spectra from shocked carbon foams were recorded on Z. The large (> 20 MA) electrical current produced by Z was used to launch Al flyer plates up to 25 km/s. The impact of the flyer plate on a CH 2 foam target produced a shocked state with an estimated pressure of 0.75 Mbar, density of 0.52 g/cm 3 , and temperature of 4.3 eV. Both unshocked and shocked portions of the foam target were probed with 6.2 keV x-rays produced by focusing the Z-Beamlet laser onto a nearby Mn foil. The data is composed of three spatially distinct spectra that were simultaneously captured with a single spectrometer with high spectral (4.8 eV) and spatial (190 μm) resolutions. Furthermore, these spectra provide detailed information on three target locations: the laser spot, the unshocked foam, and the shocked foam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Demonstration of repeatability in a high-energy-density planar shear mixing layer experiment

On laser-driven platforms the assumption of experiment repeatability is particularly important due to a typically low data acquisition rate that doesn’t often allow for data redundancy. If the platform is repeatable, then measurements of the repeatable dynamics from multiple experiments can be treated as measurements of the same system. In high-energy-density hydrodynamic instability experiments the interface growth is assumed to be one of the repeatable aspects of the system. In this paper we demonstrate the repeatability of the instability growth in the counter-propagating shear experiment at the OMEGA laser facility, where the instability growth is characterized by the tracer layer thickness or mix-width evolution. Furthermore, in our previous experiment campaigns we have assumed the instability growth was repeatable enough to identify trends, but in this work we explicitly show that the mix-width measurements for nominally identical experiments are repeatable within the measurement error bars.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction and demonstration of periodic tensile cracking in rate-dependent porous cement

Periodic dilation bands are shown to occur when cylinder-shaped saturated cement specimens are subjected to rapid decompression, with the spacing between the bands scaling as a power law of the decompression time. This behavior is predicted by theory, which is specified to this scenario based on prior work that was more general and applied to compaction. Specifically, the formation of the bands is shown to coincide with periodicity that naturally arises in the effective stress when the material follows a Terzaghi-type consolidation law, although in reverse for dilation and with material deformation described by a rate-dependent viscoplastic law. When strain rate is proportional to effective stress to a power that is greater than one, periodic regions of tensile effective stress arise through the poromechanical fluid-solid coupling. The theoretically-predicted exponent of the resulting power-law relationship between dilation band spacing and unloading time successfully brackets the experimental results, for which it is observed that the exponent is slightly stronger than a square-root relationship (0.28 to 0.67) at testing temperatures of 20 °C and 90 °C. Further, these results demonstrate that rapid-depressurization leads to periodic fracturing that could, on the one hand, be detrimental to the isolation provided by cement used to seal wellbores in the petroleum industry. On the other hand, the dilation bands could also be favorable to production if generated in low-permeability reservoir rocks such as shales that are targeted for petroleum production or granites that are targeted for geothermal energy.

36 MATERIALS SCIENCE↗