Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data virtualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

Risk Importance Ranking of Fire Data Parameters to Enhance Fire PRA Model Realism

Fire is historically and analytically a significant contributor to nuclear power plant risk. The level of fire risk and the methods, tools and data for modeling this risk is highly debated by experts. One area of debate is the input data used in fire modeling and how to deal with this data’s high uncertainty. This report outlines initial work performed for determining the key parameters causing this uncertainty and how it propagates into nuclear power plant models. This research paves the way for the development of methods to reduce fire data uncertainty used in modeling. The Nuclear Regulatory Commission has mandated that nuclear power plants perform fire risk modeling. However, there are several issues with the current risk modeling implementation that affect the results. Approved modeling methods can be overly conservative and often do not match plant experience. Also, the data used in the modeling can have high uncertainties and is influenced by expert judgement. To evaluate input data uncertainty, researchers performed an initial review of several fire experiments done at Sandia National Laboratories. Uncertainties for fire data can come from many sources, such as experiment design constraints, environmental conditions, or other plant-specific aspects. There are many different significant and insignificant parameters driving the uncertainty. Additionally, the uncertainty of the different input data used in the fire modeling could have a significant or insignificant effect on the entire plant risk. A four-step methodology was developed to perform Integrated Probabilistic Risk Assessment Importance Ranking. A demonstration case using these steps was set up and three of the four steps were completed in fiscal year (FY) 2019 and the fourth step done FY 2020. These steps are: 1. The qualitative analysis of potential sources was conducted with the following items identified for the demonstration. • Maximum heat release rate • Time to maximum heat release rate • Duration of max heat release rate • Time to decay • Thermal conductivity of concrete • Specific heat of concrete • Density of concrete • Cable jacket thickness 2. A quantitative characterization of dominant sources of uncertainty was performed. A list of distributions and determined values of the dominant sources is shown in Appendix A. 3. A quantitative screening of the potential sources of uncertainty using Morris Elementary Effects Analysis was completed. An experimental model using the physics-based fire modeling tool Fire Dynamics Simulator was developed and coupled with the Risk Analysis Virtual Environment. The Morris analysis identified at least two parameters that can be eliminated as significant contributors (specific heat of concrete and cable jacket thickness). 4. Global importance measure (Global IM) analysis to generate a comprehensive ranking based on their influence on the plant risk. In this research, a moment-independent Global IM is used since it can address (a) uncertainty in the input parameters of the fire model, (b) uncertainty in the risk outputs, and (c) non-linearity and interactions among input parameters in the fire model, more accurately than the correlation-based and variance-based global methods. The observations from the research showed that, depending on the initial and boundary conditions of the fire scenarios, fire-induced damage could have a very small probability and could be dominated by the tail of the uncertainty distribution; hence, the accuracy of the correlation-based and variance-based methods is questionable. The moment-independent Global IM analysis in this research provides a better understanding of how experimental uncertainty data affects industry’s plant models and where improvements in that data will have the largest benefit for improving fire modeling accuracy in causing core damage. Among the five unscreened parameters obtained from the Morris EE analysis, the Global IM analysis results for the case study indicated that max heat release rate and fire location are the most important parameters. The report also outlines benefits of using a unified computational platform that integrates the underlying simulations (e.g., a fire progression model), quantitative screening (using the Morris EE method), and the Global IM analysis. A unified platform can (i) facilitate the ranking of input parameters considering multiple key fire scenarios simultaneously, rather than considering one scenario at a time, (ii) contribute to more explicit and accurate treatment of dependencies at multiple levels of Fire PRA, (iii) facilitate the sampling-based uncertainty quantification for Fire PRA, and (iv) help generating both “industry-wide” and "plant-specific" ranking of uncertainty sources in Fire PRA. Future research should be done to include additional parameters such as detection/suppression or cable fire spread. Adding a PRA software such as SAPHIRE to the RAVEN platform would help with plant model integration and improve treatment of fire-induced dependency. The I-PRA risk importance ranking methodology offered in this report can provide valuable information for efficiently (a) enhancing the realism of Fire PRA for existing plants and (b) supporting the development of Dynamic Fire PRA for advanced reactors and new plants.

97 MATHEMATICS AND COMPUTING↗

Nucleon Resonance Physics

Recent results of meson photo-production at the existing electron machines with polarized real photon beams and the measurement of polarization observables of the final state baryons have provided high precision data that led to the discovery of new excited nucleon and $\Delta$ states using multi-channel partial wave analyses procedures. The internal structure of several prominent excited states has been revealed employing meson electroproduction processes. On the theoretical front, lattice QCD is now predicting the baryon spectrum with very similar characteristics as the constituent quark model, and continuum QCD, such as is represented in the Dyson-Schwinger Equations approach and in light front relativistic quark models, describes the non-perturbative behavior of resonance excitations at photon virtuality of $Q^2 > 1.5GeV^2$. In this talk I discuss the need to continue a vigorous program of nucleon spectroscopy and the study of the internal structure of excited states as a way to reveal the effective degrees of freedom underlying the excited states and their dependence on the distance scale probed.

Burkert, Volker D. (ORCID:0000000347470838)↗

Assessment of cardiac single-photon emission computed tomography performance using a scanning linear observer

Purpose: Single-photon emission computed tomography (SPECT) is widely used to detect myocardial ischemia and myocardial infarction. It is important to assess and compare different SPECT system designs in order to achieve the highest detectability of cardiac defects. Methods: Whitaker et al.'s study ['Estimating random signal parameters from noisy images with nuisance parameters: linear and scanning-linear methods,' Opt. Express 16(11), 8150-8173 (2008)] on the scanning linear observer (SLO) shows that the SLO can be used to estimate the location and size of signals. One major advantage of the SLO is that it can be used with projection data rather than with reconstruction data. Thus, this observer model assesses the overall hardware performance independent of any reconstruction algorithm. In addition, the computation time of image quality studies is significantly reduced. In this study, three systems based on the design of the GE cadmium zinc telluride-based dedicated cardiac SPECT camera Discovery 530c were assessed. This design, which is officially named the Alcyone Technology: Discovery NM 530c, was commercialized in August, 2009. The three systems, GE27, GE19, and GE13, contain 27, 19, and 13 detectors, respectively. Clinically, a human heart can be virtually segmented into three coronary artery territories: the left-anterior descending artery, left-circumflex artery, and right coronary artery. One of the most important functions of a cardiac SPECT system is to produce images from which a radiologist can accurately predict in which territory the defect exists [http://www.asnc.org/media/PDFs/PPReporting081511.pdf, Guideline from American Society of Nuclear Cardiology]. A good estimation of the extent of the defect from the projection images is also very helpful for determining the seriousness of the myocardial ischemia. In this study, both the location and extent of defects were estimated by the SLO, and the system performance was assessed by localization receiver operating characteristic (LROC) [P. Khurd and G. Gindi, 'Decision strategies maximizing the area under the LROC curve,' Proc. SPIE 5749, 150-161 (2005)] or estimation receiver operating characteristic (EROC) [E. Clarkson, 'Estimation receiver operating characteristic curve and ideal observers for combined detection/estimation tasks,' J. Opt. Soc. Am. A 24, B91-B98 (2007)] curves. Results: The area under the LROC/EROC curve (AULC/AUEC) and the true positive fraction (TPF) at a specific false positive fraction (FPF) can be treated as the figures of merit. For radii estimation with a 1 mm tolerance, the AUEC values of the GE27, GE19, and GE13 systems are 0.8545, 0.8488, and 0.8329, and the TPF at FPF = 5% are 77.1%, 76.46%, and 73.55%, respectively. The assessment of all three systems revealed that the GE19 system yields estimated information and cardiac defect detectability very close to those of the GE27 system while using eight fewer detectors. Thus, 30% of the expensive detector units can be removed with confidence. Conclusions: As the results show, a combination of the SLO and LROC/EROC curves can determine the configuration that yields the most relevant estimation/detection information. Thus, this is a useful method for assessing cardiac SPECT systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calibration of a Neutron Hydroprobe for Moisture Measurements in Small-Diameter Steel-Cased Boreholes

Computation of soil moisture content from thermalized neutron counts for the T-Farm Interim cover requires a calibration relationship but none exists for 2-in tubes. A number of calibration options are available for the neutron probe, including vendor calibration, field calibration, but none of these methods were deemed appropriate for the configuration of interest. The objective of this work was to develop a calibration relation for converting neutron counts measured in 2-in access tubes to soil water content. The calibration method chosen for this study was a computational approach using the Monte Carlo N-Particle Transport Code (MCNP). Model calibration was performed using field measurements in the Hanford calibration models with 6-in access tubes, in air and in the probe shield. The bet-fit model relating known water content to measured neutron counts was an exponential model that was essentially equivalent to that currently being used for 6-in steel cased wells. The MCNP simulations successfully predicted the neutron count rate for the neutron shield and the three calibration models for which data were collected in the field. However, predictions for air were about 65% lower than the measured counts . This discrepancy can be attributed to uncertainties in the configuration used for the air measurements. MCNP-simulated counts for the physical models were essentially equal to the measured counts with values. Accurate prediction of the response in 6-in casings in the three calibration models was motivation to predict the response in 2-in access tubes. Simulations were performed for six of the seven calibration models as well as 4 virtual models with the entire set covering a moisture range of 0 to 40%. Predicted counts for the calibration models with 2-in access tubes were 40 to 50% higher than in the 6-inch tubes. Predicted counts for water were about 60% higher in the 2-in tube than in the 6-in tube. The discrepancy between the 2-in and 6-in tube can be attributed to the smaller air gap between the probe and the 2-in access tube. The best-fit model relating volumetric water content to count ratio (CR) is of the form e^A x CR^B with A=0.3596 ± 0.0216 and B=0.4629 ± 0.0629 and r^2= 0.9998. It is recommended that the calibration function based on the count ratio, rather than raw counts, be used to avoid the effects of electronic noise in the probe that may arise due to the conditions at the time of measurement. These results suggest that the MCNP code can be used to extend calibrations for the neutron probe to different conditions including access tube size as well as composition without the need to construct additional physical models.

36 MATERIALS SCIENCE↗

Neural Network Analysis of Nuclear Magnetic Resonance and Infrared Spectra

Nuclear magnetic resonance (NMR) spectroscopy and infrared (IR) spectroscopy are powerful chemical characterization techniques with broad general usage. However, the manual evaluation of the resulting spectra is time-consuming and requires significant expertise, preventing insights from being used in real-time applications. With recent advances in computation and artificial intelligence (AI), new tools are available for automating spectral interpretation. In this work, machine learning (ML) algorithms using 1-dimensional convolutional neural networks (CNNs) were applied to identify common functional groups from spectral information. Raw spectra were collected virtually from the Human Metabolome Database (HMDB) and National Institute of Standards and Technology (NIST) Chemistry WebBook and processed into a suitable standard. Algorithm design was tailored to best fit the nature of the problem, with built-in flexibility to accommodate relevant parameters beyond the raw spectral input, specifically solvent identity and magnetic frequency for NMR. The predictive capability of the algorithm in identifying functional groups is displayed in several examples. This methodology has been compiled into a code repository and could easily be modified to adapt alternative data sources, including other spectrum types. To mitigate overfitting, a common problem in mathematical modeling where overfamiliarity with training data produces trends that are not representative of the general data, a novel metric was developed, referred to as Accufit. Accufit includes a parameter that penalizes substantial differences in the training accuracy and the accuracy of an independent validation set. Examples are presented showing the effectiveness of Accufit in maintaining the model’s predictive capability while controlling the overfitting when used as a custom metric for hyperparameter tuning.

Sturgill, James↗

AGC-4 Experiment Irradiation Monitoring Data Qualification Final Report

The Graphite Technology Development Program ran a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. This report focuses on the fourth experiment, Advanced Graphite Creep 4 (AGC 4). The Advanced Reactor Development (ARD) Technology Development Office (TDO) Program for research and development activities require documentation of qualified monitoring data to design and license the first high-temperature reactor nuclear plant. Qualified data meets the requirements for use as described in the experiment planning and quality assurance documents. Failed data do not meet the requirements and provide no useable information. Trend data may not meet all requirements but still provide some useable information. Use of Trend data requires assessment of how any deficiencies affect a particular use of the data. AGC-4 began with Advanced Test Reactor (ATR) Cycle 157D on May 30, 2015. After irradiating the graphite for two cycles, the capsule was removed from the reactor after ATR Cycle 158A, which ended on January 2, 2016, due to interference with another experiment. Irradiation was resumed with Cycle 162A on October 7, 2017 after the interfering experiment was removed from the reactor. AGC-4 irradiation completed by the end of Cycle 166B on January 10, 2020. Between Cycles 162A and 166B, AGC-4 capsule was removed from the reactor core during two Powered Axial Locator Mechanism (PALM) Cycles 163A and 165A to avoid overheating. All thermocouples (TCs) have functioned throughout the AGC-4 experiment. A total of 9,256,184 out of all 11,167,213 temperature records (or 82.9%) are Qualified for use by the ARD Program and 1,911,029 missing values are Failed. Argon, helium, and total gas flow data were within expected ranges, except only eight out-of-range values occurred during outages. A total of 21,240,627 out of all 22,288,5103 gas flow rates (or 92.8%) are Qualified for use by the ARD Program and 1,644,476 are Failed records mostly due to missing values. Discharge gas line moisture values were consistently low during full ATR power, except for 162B, when moisture content was increasing to more than 200 ppmv by the end of this cycle. During outages, moisture content reached as high as 700 ppmv. 1,089,941 out of a total of 1,107,331 moisture values (or 98.4%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 17,390 missing moisture values are Failed. Graphite creep specimens were subjected to one of three loads: 393, 491, or 589 lbf. For a brief period during Cycle 157D between 12:19 on June 2, 2015, and 08:23 on June 11, 2015, the load cells were wired incorrectly, resulting in missing stack load data. Missing stack loads were estimated from measured ram pressures using regression equations developed from the existing data from Cycle 157D. Estimated stack loads during this period are considered to be an accurate representation of actual load applied to the stacks. These loads deviate slightly from the planned loads. This deviation does not prevent the data from being Qualified for use but must be taken into account when analyzing the effect of load on creep. 6,095,728 out of a total of 6,403,985 moisture values (or 95.2%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 308,257 missing load values are Failed. Stack displacement increased consistently throughout the eight cycles, with total displacement reached highest value of 2.4 in by the end of irradiation. During ATR outages, a set of pneumatic rams raised the stacks of graphite creep specimens to ensure the specimens were not stuck within the test train. This stack raising was performed seven times throughout irradiation. All stacks were raised successfully each time. 4,744,974 out of a total of 6,094,513 displacement values (or 77.9%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 1,349,539 displacement values are Failed mostly due to missing values. Analyses were conducted on correlations between TCs to look for trends and step changes that might indicate instrument degradation or failure. Correlation analysis was used to identify instances when TCs form short circuits, referred to as virtual junctions, which result in TCs reporting temperatures from some location in the capsule other than the location where they were intended to read. No evidence of virtual junctions was found. Analyses were also conducted on control charts of temperature differences of between two TCs, which are expected to behave consistently throughout the entire irradiation period. Upward or downward trend over time indicates at least one TC in the pair was drifted. Examining control charts for all 66 possible pairs out of twelve TCs installed in the AGC-4 capsules reveal no clear drift failures occurred, except unstable behavior of two TCs in Zone 3, TC-7 and TC-8, over irradiation time. In conclus

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sentinel Devices LLC (CRADA Final Report)

Industrial equipment is a critical component of virtually all at-scale manufacturing and infrastructure. Broadly speaking, modern equipment is predominantly controlled using hardened digital controllers – computers designed to be able to operate continuously for sometimes extremely long periods of time, with little to no maintenance. Due to the nature of how these digital controllers have evolved, they are solely optimized to execute a single task, and do not have the capabilities or resources to monitor or analyze their internal state beyond simple execution of their program. As a result, for many “common sense” situations where individual data points can be easily determined to be out-of-normal, the controllers are unable to identify these incorrect operational modes unless a human has explicitly programmed in detection of this degradation. This project seeks to develop an AI/ML system which can identify incorrect or anomalous trends in industrial data streams, of exactly the kind that would be produced and seen by these digital controllers, with a minimal amount of computing resources. The benefits produced by developing this system would ultimately be self-monitoring and self-reporting infrastructure, capable of identifying and alerting humans to issues as soon as they happen, potentially long before they have the chance to impact the industrial process.

42 ENGINEERING↗

VERSION 1 OF THE HUBBLE SOURCE CATALOG

The Hubble Source Catalog is designed to help optimize science from the Hubble Space Telescope (HST) by combining the tens of thousands of visit-based source lists in the Hubble Legacy Archive (HLA) into a single master catalog. Version 1 of the Hubble Source Catalog includes WFPC2, ACS/WFC, WFC3/UVIS, and WFC3/IR photometric data generated using SExtractor software to produce the individual source lists. The catalog includes roughly 80 million detections of 30 million objects involving 112 different detector/filter combinations, and about 160,000 HST exposures. Source lists from Data Release 8 of the HLA are matched using an algorithm developed by Budavári and Lubow. The mean photometric accuracy for the catalog as a whole is better than 0.10 mag, with relative accuracy as good as 0.02 mag in certain circumstances (e.g., bright isolated stars). The relative astrometric residuals are typically within 10 mas, with a value for the mode (i.e., most common value) of 2.3 mas. The absolute astrometric accuracy is better than 0{sup ″} .1 for most sources, but can be much larger for a fraction of fields that could not be matched to the PanSTARRS, SDSS, or 2MASS reference systems. In this paper we describe the database design with emphasis on those aspects that enable the users to fully exploit the catalog while avoiding common misunderstandings and potential pitfalls. We provide usage examples to illustrate some of the science capabilities and data quality characteristics, and briefly discuss plans for future improvements to the Hubble Source Catalog.

79 ASTRONOMY AND ASTROPHYSICS↗

Virtuality Distributions and γγ * -> π 0 Transition at Handbag Level

We outline a new approach to transverse momentum dependence in hard processes using as an example the exclusive transition ${\gamma^{*}\gamma \to \pi^{0}}$ at the handbag level. We start with the coordinate representation for a matrix element ${\langle p |{\cal O}(0,z) |0 \rangle}$ of a bilocal operator ${{\cal O} (0,z)}$ describing a hadron with momentum p. Treated as a function of (pz) and z$^{2}$, it is parametrized through virtuality distribution amplitude (VDA) Φ (x, σ), with x being Fourier-conjugate to (pz) and σ Laplace-conjugate to z$^{2}$. For intervals with z$^{+}$ = 0, we introduce the transverse momentum distribution amplitude (TMDA) ${\Ψ (x,k_{\perp})}$ , and write it in terms of VDA Φ (x, σ). The results of covariant calculations, written in terms of Φ (x, σ) are converted into expressions involving ${\Ψ (x,k_{\perp})}$ . We propose simple models for soft VDAs/TMDAs, and use them for comparison of handbag results with experimental (BaBar and BELLE) data on the pion transition form factor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Higgsinos in final states with low-momentum lepton-track pairs at 13 TeV

We present a search for the pair production of Higgsinos in final states with large missing transverse momentum and either two reconstructed muons or a reconstructed lepton (muon or electron) and an isolated track. The analyzed data correspond to proton-proton collisions with an integrated luminosity of 137 fb −1 , collected by the CMS experiment at $\sqrt{𝑠}$ =13 TeV in 2016, 2017, and 2018. The signal scenario assumes four nearly mass degenerate Higgsino mass eigenstates: two neutralino states $\tilde{𝜒}^0_2$ and $\tilde{𝜒}^0_1$ with a small mass difference in the range 1–10 GeV and two chargino states $\tilde{𝜒}^±_1$ with an intermediate mass. The analysis focuses on the decay of the heavier neutralino into the lighter one and a virtual 𝑍 boson, which decays into two same-flavor leptons. The leptons have small transverse momentum and/or a small opening angle between the identified muons. An isolated track is used to recover events in which only one of the two leptons is identified. Multivariate discriminants are used to enhance the sensitivity by efficiently rejecting backgrounds from SM processes or misreconstructed tracks and/or leptons. The search explores a unique phase space and probes a previously unexplored region of the signal model parameter space. Mass differences between the two neutralinos are probed down to 1.5 GeV, assuming a Higgsino mass of 100 GeV. The maximum excluded Higgsino mass is 115 GeV.

Hayrapetyan, A. [Yerevan Physics Institute]↗

TU-D-201-05: Validation of Treatment Planning Dose Calculations: Experience Working with MPPG 5.a

Purpose: Newly published medical physics practice guideline (MPPG 5.a.) has set the minimum requirements for commissioning and QA of treatment planning dose calculations. We present our experience in the validation of a commercial treatment planning system based on MPPG 5.a. Methods: In addition to tests traditionally performed to commission a model-based dose calculation algorithm, extensive tests were carried out at short and extended SSDs, various depths, oblique gantry angles and off-axis conditions to verify the robustness and limitations of a dose calculation algorithm. A comparison between measured and calculated dose was performed based on validation tests and evaluation criteria recommended by MPPG 5.a. An ion chamber was used for the measurement of dose at points of interest, and diodes were used for photon IMRT/VMAT validations. Dose profiles were measured with a three-dimensional scanning system and calculated in the TPS using a virtual water phantom. Results: Calculated and measured absolute dose profiles were compared at each specified SSD and depth for open fields. The disagreement is easily identifiable with the difference curve. Subtle discrepancy has revealed the limitation of the measurement, e.g., a spike at the high dose region and an asymmetrical penumbra observed on the tests with an oblique MLC beam. The excellent results we had (> 98% pass rate on 3%/3mm gamma index) on the end-to-end tests for both IMRT and VMAT are attributed to the quality beam data and the good understanding of the modeling. The limitation of the model and the uncertainty of measurement were considered when comparing the results. Conclusion: The extensive tests recommended by the MPPG encourage us to understand the accuracy and limitations of a dose algorithm as well as the uncertainty of measurement. Our experience has shown how the suggested tests can be performed effectively to validate dose calculation models.

60 APPLIED LIFE SCIENCES↗

Development of a Tender-Energy Microprobe for Geosciences at NSLS and NSLS-II

This funding is to develop a new Synchrotron user facility for microbeam X-ray absorption spectroscopy (XAS) and quantitative X-ray fluorescence (XRF) imaging, at the National Synchrotron Light Source (NSLS) and NSLS-II. It includes design, purchase of components, and construction of the microprobe endstation and controls. Initial development, commissioning, and application is ongoing at NSLS Beamline X15B, with planned transition in 2014-15 to the NSLS-II TES (Tender-Energy Spatially Resolved X-ray Absorption Spectroscopy) beamline. It is optimized for the “tender” energy range of 1-5 keV, reaching up to 8 keV. Thus it uniquely covers the K absorption edges of critical elements Mg, Al, Si, P, S, Cl, and Ca, and can reach up to Co. A stable, high-flux microbeam focus, user-tunable from ~50 to ~5 microns, has been achieved using two-stage achromatic focusing. Existing beamline optics collimate, monochromate, and macro-focus the X-ray beam to ~1 mm at a secondary source aperture (SSA). Beam from the SSA is then re-focused by a pair of mirrors in KB geometry to the microbeam scale. Size of the microbeam is tunable, at the expense of flux, by adjusting the size of the SSA as a virtual source. The new experimental endstation consists of 1) a sample chamber operable as a radiation enclosure with helium atmosphere to facilitate measurements in this energy range, 2) the KB microfocusing optics, 3) a sample-positioning stage for raster-scanning and positioning the sample, 4) X-ray fluorescence detectors, an existing Ge detector for low-signal sensitivity and a new Si detector for high count rates, 5) an optical camera for viewing samples and locating target locations, 6) beam intensity monitors and diagnostics, and 7) controls and data acquisition system. An important aspect of this project is the added capability for fast, on-the-fly scanning of the monochromator (energy), required for fast XAS and advanced XAS imaging. This instrument will be available for initial PI and Co-I measurements, and for General Users to apply for beamtime to use, at NSLS X15B for the remaining operation of NSLS, to September 30, 2014. Phase two of this project will transition this facility, both the primary optics and the endstation, to NSLS-II after NSLS ceases operation. While this transition itself is beyond the scope of the current grant, preparation and planning for it is included.

58 GEOSCIENCES↗

Once-Through Steam Generator Model Analysis Using Python and Advanced Optimization Tools (Summer Internship Report)

This study focuses on the parametric analysis of design parameters for a once-through steam generator (OTSG) model, using python and advanced optimization tools to facilitate applications such as the flowing autoclave steam generator (FASG) test cases. Building on previous research involving another OTSG with a different design, this project aims to enhance our understanding of how steam generators (SGs) behave and how their outputs are influenced by changes in design. The reason for this design change is to allow for more precise modeling and optimization of SG performance, to provide a comparative analysis between the two designs, and to set up the model for integration with the FASG test case. The OTSG python-model is a mathematical representation (including fluid flow and heat transfer equations/models/correlations) of a steam-generating unit in a pressurized water reactor-type small modular reactor system. Design studies involve changing the model’s input design parameters to observe the resulting effects on the output of the system. By using advanced optimization tools, such as the Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory, detailed design parametric studies and model optimization were performed. Six input parameters—pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid), respectively, of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (i.e., ±1%, ±5% and ±10% relative changes) for 600 samples. The analysis provides valuable insights into SG optimization and can be used for sensor placement optimization to effectively monitor and obtain experimental data in other tests.

20 FOSSIL-FUELED POWER PLANTS↗

p +p - electroproduction off protons in deuterium: measurements of quasi-free cross sections and kinematic probing of final state interactions

In this study, the process of pi+pi- electroproduction off protons bound in deuterium nuclei is explored. The exploration is performed through the analysis of experimental data on electron scattering off the deuteron target, collected in Hall B at Jefferson Lab with the CLAS detector. As a main result, the set of integrated and single-differential cross sections of the reaction yvp(n) -> p'(n')pi+pi- is obtained. The cross sections are extracted in the quasi-free regime, which implies that only events not affected by final state interactions are subject to selection. The measurements are performed in the kinematic region of the invariant mass W from 1.3 GeV to 1.825 GeV and photon virtuality Q2 from 0.4 GeV2 to 1 GeV2. Sufficient experimental statistics allows narrow binning, i.e. 25 MeV in W and 0.05 GeV2 in Q2, while maintaining an adequate statistical uncertainty. The extraction of quasi-free cross sections is accompanied by the kinematic probing of FSI between the reaction final hadrons and the spectator neutron in the aforementioned exclusive channel. In this probing the distributions of missing quantities are used in order to investigate the relative spread of events with FSI along the reaction phase space, trace the difference of FSI manifestations in different reaction topologies, reveal details on alterations of the hadron momentum in FSI, and isolate FSI contributions of various final hadrons. The performed examination is also capable of retrieving information on some underlying FSI mechanisms, among which the process of resonance formation in the intermediate state of pion-neutron interactions is particularly remarkable.

Skorodumina, Iuliia↗

Steam Generator Model Design Parameter Sensitivity Study Using Advanced Optimization Tools

This study focuses on design parameter sensitivity studies pertaining to a steam generator (SG) model, using both Python and machine-learning tools. The SG model is a mathematical representation (including fluid flow and heat transfer equations/models/correlations) of a steam-generating unit in a pressurized water reactor (PWR)-type small modular reactor (SMR) system. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system (e.g., heat transfer coefficient [HTC], Nusselt number, heat transfer performance). Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in input parameters. By using machine-learning tools such as the Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), detailed design parametric sensitivity studies and model optimization were performed. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (±1% relative changes). The analysis results give valuable insights into SG system performance and optimization, and provide justification for researching optimized sensor placement to effectively monitor and obtain experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Steam Generator Model Design Parameter Sensitivity Study Using Advanced Optimization Tools

This study focuses on design parameter sensitivity studies pertaining to a steam generator (SG) model, using both Python and machine-learning tools. The SG model is a mathematical representation (including fluid flow and heat transfer equations/models/correlations) of a steam-generating unit in a pressurized water reactor (PWR)-type small modular reactor (SMR) system. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system (e.g., heat transfer coefficient [HTC], Nusselt number, heat transfer performance). Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in input parameters. By using machine-learning tools such as the Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), detailed design parametric sensitivity studies and model optimization were performed. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (±1% relative changes). The analysis results give valuable insights into SG system performance and optimization, and provide justification for researching optimized sensor placement to effectively monitor and obtain experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Timelike Compton Scattering from a longitudinally polarised target with CLAS12 at Jefferson Lab

Explorations into the internal dynamics of hadrons are constantly evolving, and the requirement for experimental results to verify theoretical models of hadron structure is paramount. A key area in this field is the study of Generalised Parton Distributions (GPDs), which are functions used to model the momenta of quarks and gluons within hadrons, and the methods to access GPDs experimentally. One such scattering process that allows access to these is Timelike Compton Scattering. TCS complements existing Deeply Virtual Compton Scattering experiments and allows investigation into the universality of GPDs through access to the real and imaginary parts of the parton helicity independent GPD Hq via beam spin asymmetries (BSA), and it provides novel access to the real and imaginary parts of the parton helicity dependent GPD ˜Hq through target polarisation asymmetries (TSA). This thesis work presents a comparative study with the first published BSA for TCS at the Thomas Jefferson National Accelerator Facility (JLab), alongside a first time extraction of a Target Spin Asymmetry with the Summer 2022 data taking run. JLab hosts the Continuous Electron Beam Accelerator Facility (CEBAF) which provides a 12 GeV electron beam to four experimental halls. Hall-B contains the CEBAF Large Acceptance Spectrometer, which took data across three run periods on a longitudinally polarised NH3 and ND3 fixed target from 2022-2023, to extract measurements of electron-proton scattering, from which a TCS signal could be extracted. The thesis discusses work done to understand and eliminate contributions from the non-/low-polarised nuclear background, testing pre-established cuts to eliminate pion background from a dilepton (e+e-) final state and modifying them as needed for the new experimental run, and attempts to hone in on a clean TCS signal from which to extract the two asymmetry observables. A comparison with existing BSA results was performed; however, the statistical errors are too large to draw a significant conclusion as to whether there is agreement across each bin. More data is needed for a multidimensionally binned extraction. A proof of principle was achieved in the TSA measurements, with two out of four kinematic bins showing preliminary agreement in shape with theoretical values. Again, the errors are significant due to the contributions from the nuclear background. To support these conclusions, a further study was done, which takes into account an estimate of the asymmetries with the full available dataset (this thesis is based only on data taken in the summer set; at the time of writing processing was still being conducted for the final two datasets), as well as an estimate including additional future experiment days that were awarded in July 2024. Additional work was done on a secondary project exploring the feasibility of measuring TCS at the upcoming Electron Ion Collider, supporting the design proposal for the detector for the first interaction region and giving a positive outlook for the future of these types of measurements beyond JLab.

Gates, Kayleigh [Univ. of Glasgow, Scotland (Unite↗

Nucleon Structure Studies at Jefferson Lab and the Electron Ion Collider

The research programs of Thomas Jefferson Laboratory (JLab) and the future Electron- Ion Collider (EIC) focus on one of the main goals of strong interaction studies : understanding the structure of nucleons in terms of the quarks and gluons composing them. Their structure is encoded in functions such as Generalized Parton Distributions (GPDs), which describe how quarks and gluons’ transverse position and longitudinal momentum are distributed inside nucleons. GPDs allow to obtain three-dimensional pictures of nucleons and to understand some of their fundamental properties, such as their internal pressure or the emergence of their spin from the dynamics of the partons composing them. At JLab and the EIC, electron beams are used to probe nucleons. Measurement of reactions such as Deeply Virtual Compton Scattering (DVCS) allows access to GPDs. The first longitudinally polarized-target experiment of the CLAS12 program at Jlab took place in 2022-2023. Combining polarized electron beams and nucleon targets, this experiment offers unique access to observables that allow the measurement of different types of GPDs. In particular, the DVCS beam- and target-spin asymmetries for protons and neutrons in deuterium will be measured for the first time. They give access to kinds of GPDs that are still poorly known, and the comparison between proton and neutron data will allow the extraction of the flavor dependence of the structure of nucleons. Specific analysis methods have been implemented to work with a polarized nuclear target and are presented in this thesis. These methods allow to obtain preliminary results for the asymmetries, waiting for the complete statistics to be available. In the long term, the experimental program for the EIC has been established with a strong emphasis on the measurement of the structure of nucleons at high energy. Measurements of reactions such as DVCS impose strict requirements on the electromagnetic calorimeter that will allow to measure the energy of the scattered electrons and photons. This calorimeter, which is under development, will be based on scintillating crystals read by Silicon Photomultipliers (SiPMs). A new type of glass-based scintillating material was tested, evaluating the possibilities to meet the technical requirements concerning their light yield and resistance to radiation damage in particular. Several models of SiPMs have been characterized, demonstrating they can operate over the vast energy range necessary to address the physics case at the EIC and providing guidelines for developing their readout electronics.

Pilleux, Noemie↗