Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,531 records · Page 85

SU-D-16A-02: A Novel Methodology for Accurate, Semi-Automated Delineation of Oral Mucosa for Radiation Therapy Dose-Response Studies

Purpose: The significant morbidity caused by radiation-induced acute oral mucositis means that studies aiming to elucidate dose-response relationships in this tissue are a high priority. However, there is currently no standardized method for delineating the mucosal structures within the oral cavity. This report describes the development of a methodology to delineate the oral mucosa accurately on CT scans in a semi-automated manner. Methods: An oral mucosa atlas for automated segmentation was constructed using the RayStation Atlas-Based Segmentation (ABS) module. A radiation oncologist manually delineated the full surface of the oral mucosa on a planning CT scan of a patient receiving radiotherapy (RT) to the head and neck region. A 3mm fixed annulus was added to incorporate the mucosal wall thickness. This structure was saved as an atlas template. ABS followed by model-based segmentation was performed on four further patients sequentially, adding each patient to the atlas. Manual editing of the automatically segmented structure was performed. A dose comparison between these contours and previously used oral cavity volume contours was performed. Results: The new approach was successful in delineating the mucosa, as assessed by an experienced radiation oncologist, when applied to a new series of patients receiving head and neck RT. Reductions in the mean doses obtained when using the new delineation approach, compared with the previously used technique, were demonstrated for all patients (median: 36.0%, range: 25.6% – 39.6%) and were of a magnitude that might be expected to be clinically significant. Differences in the maximum dose that might reasonably be expected to be clinically significant were observed for two patients. Conclusion: The method developed provides a means of obtaining the dose distribution delivered to the oral mucosa more accurately than has previously been achieved. This will enable the acquisition of high quality dosimetric data for use in dose-response studies. We would like to thank the Engineering and Physical Sciences Research Council for funding. We acknowledge support from the NIHR RM/ICR Biomedical Research Centre. RayStatation was used under an evaluation agreement with RaySearch Laboratories AB.

60 APPLIED LIFE SCIENCES↗

The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance

Purpose: High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named “magic phantom” (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. Methods: The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the “position–time gamma index,” was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. Results: For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position–time gamma index showed that all modifications made could be readily detected. The MPh was able to measure dwell times down to 0.067 ± 0.001 s and planned dwell positions separated by 1 mm. The dose calculation carried out by the MPh software was found to be in agreement with values calculated by the treatment planning system within 0.75%. Using the 2D gamma index, the dose map of the MPh plane and measured EBT3 were found to have a pass rate of over 95% when compared to the original plan. Conclusions: The application of this magic phantom quality assurance system to HDR brachytherapy has demonstrated promising ability to perform the verification of treatment plans, based upon the measured dwell positions and times. The introduction of the quantitative position–time gamma index allows for direct comparison of measured parameters against the plan and could be used prior to patient treatment to ensure accurate delivery.

60 APPLIED LIFE SCIENCES↗

TU-CD-304-04: Scanning Field Total Body Irradiation Using Dynamic Arc with Variable Dose Rate and Gantry Speed

Purpose: Enable a scanning field total body irradiation (TBI) technique, using dynamic arcs, which is biologically equivalent to a moving couch TBI. Methods: Patient is treated slightly above the floor and the treatment field scans across the patient by a moving gantry. MLC positions change during gantry motion to keep same field opening at the level of the treatment plane (170 cm). This is done to mimic the same geometry as the moving couch TBI technique which has been used in our institution for over 10 years. The dose rate and the gantry speed are determined considering a constant speed of the moving field, variations in SSD and slanted depths resulting from oblique gantry angles. An Eclipse (Varian) planning system is commissioned to accommodate the extended SSD. The dosimetric foundations of the technique have been thoroughly investigated using phantom measurements. Results: Dose uniformity better than 2% across 180 cm length at 10cm depth is achieved by moving the gantry from −55 to +55 deg. Treatment range can be extended by increasing gantry range. No device such as a gravity-oriented compensator is needed to achieve a uniform dose. It is feasible to modify the dose distribution by adjusting the dose rate at each gantry angle to compensate for body thickness differences. Total treatment time for 2 Gy AP/PA fields is 40–50 minutes excluding patient set up time, at the machine dose rate of 100 MU/min. Conclusion: This novel yet transportable moving field technique enables TBI treatment in a small treatment room with less program development preparation than other techniques. Treatment length can be extended per need, and. MLC-based thickness compensation and partial lung blocking are also possible.

60 APPLIED LIFE SCIENCES↗

SU-F-T-32: Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source

Purpose: To evaluate the performance of a two-dimensional (2D) array-diode- detector for geometric and dosimetric quality assurance (QA) tests of high-dose-rate (HDR) brachytherapy with an Ir-192-source. Methods: A phantom setup was designed that encapsulated a two-dimensional (2D) array-diode-detector (MapCheck2) and a catheter for the HDR brachytherapy Ir-192 source. This setup was used to perform both geometric and dosimetric quality assurance for the HDR-Ir192 source. The geometric tests included: (a) measurement of the position of the source and (b) spacing between different dwell positions. The dosimteric tests include: (a) linearity of output with time, (b) end effect and (c) relative dose verification. The 2D-dose distribution measured with MapCheck2 was used to perform the previous tests. The results of MapCheck2 were compared with the corresponding quality assurance testes performed with Gafchromic-film and well-ionization-chamber. Results: The position of the source and the spacing between different dwell-positions were reproducible within 1 mm accuracy by measuring the position of maximal dose using MapCheck2 in contrast to the film which showed a blurred image of the dwell positions due to limited film sensitivity to irradiation. The linearity of the dose with dwell times measured from MapCheck2 was superior to the linearity measured with ionization chamber due to higher signal-to-noise ratio of the diode readings. MapCheck2 provided more accurate measurement of the end effect with uncertainty < 1.5% in comparison with the ionization chamber uncertainty of 3%. Although MapCheck2 did not provide absolute calibration dosimeter for the activity of the source, it provided accurate tool for relative dose verification in HDR-brachytherapy. Conclusion: The 2D-array-diode-detector provides a practical, compact and accurate tool to perform quality assurance for HDR-brachytherapy with an Ir-192 source. The diodes in MapCheck2 have high radiation sensitivity and linearity that is superior to Gafchromic-films and ionization chamber used for geometric and dosimetric QA in HDR-brachytherapy, respectively.

60 APPLIED LIFE SCIENCES↗

SU-F-T-58: Dosimetric Evaluation of Breast Tissue Composition for Electronic Brachytherapy (BET) Source In High Dose Rate Accelerated Partial Breast (APBI) Irradiation

Purpose: To quantitatively evaluate the dosimetric impact of differing breast tissue compositions for electronic brachytherapy source for high dose rate accelerated partial breast irradiation. Methods: A series of Monte Carlo Simulation were created using the GEANT4 toolkit (version 10.0). The breast phantom was modeled as a semi-circle with a radius of 5.0 cm. A water balloon with a radius of 1.5 cm was located in the phantom with the Xoft AxxentTM EBT source placed at center as a point source. A mixed of two tissue types (adipose and glandular tissue) was assigned as the materials for the breast phantom with different weight ratios. The proportionality of glandular and adipose tissue was simulated in four different fashions, 80/20, 70/30, 50/50 and 30/70 respectively. The custom energy spectrum for the 50 kVp XOFT source was provided via the manufacturer and used to generate incident photons. The dose distributions were recorded using a parallel three dimensional mesh with a size of 30 × 30 × 30 cm3 with 1 × 1 × 1 mm3 voxels. The simulated doses absorbed along the transverse axis were normalized at the distance of 1 cm and then compared with the calculations using standard TG-43 formalism. Results: All simulations showed underestimation of dose beyond balloon surface compared to standard TG-43 calculations. The maximum percentage differences within 2 cm distance from balloon surface were found to be 18%, 11%, 10% and 8% for the fat breast (30/70), standard breast (50/50), dense breast (70/30 and 80/20), respectively. Conclusion: The accuracy of dose calculations for low energy EBT source was limited when considering tissue heterogeneous composition. The impact of atomic number on photo-electric effect for lower energy Brachytherapy source is not accounted for and resulting in significant errors in dose calculation.

60 APPLIED LIFE SCIENCES↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

Dose dependence of strength after low-temperature irradiation in metallic materials

This study intends to review and characterize the low-temperature (< 200 oC) irradiation hardening behaviors in metallic materials and to propose new interpretations on the dose dependence of strength, particularly in the pre-hardening and saturation regimes. The analysis results of yield stress-dose curves indicate that four dose-dependence regimes exist: the pre-hardening, main hardening, saturation, and embrittlement regimes. The semi-log plots of yield stress versus dose data revealed that the pre-hardening regime displaying zero-hardening or softening was common at least for the alloys with low dose data available. It was observed that the dose range of the pre-hardening regime increased with the strength of material, which indicates that slower initiation in irradiation hardening is expected when strength is higher. For the majority of the metallic materials analyzed, it was reconfirmed that the exponent of the power-law hardening function was evaluated to be about 0.5 in the main hardening regime and about 0.1 in the saturation regime. In these positive hardening regimes the low strength pure metals such as Fe, Ta, Cu, and Zr displayed lower hardening exponents. The minimum dose to the saturation of irradiation hardening was in the range of 0.003 0.08 dpa, depending on the category of materials. It was also reaffirmed that there exists a strong relationship between the saturation in irradiation hardening and the occurrence of plastic instability at yield.

Byun, Thak Sang↗

Characterizing regional-scale temporal evolution of air dose rates after the Fukushima Daiichi Nuclear Power Plant accident

In this paper, we quantify the temporal changes of air dose rates in the regional scale around the Fukushima Dai-ichi Nuclear Power Plant in Japan, and predict the spatial distribution of air dose rates in the future. We first apply the Bayesian geostatistical method developed by Wainwright et al. (2017) to integrate multiscale datasets including ground-based walk and car surveys, and airborne surveys, all of which have different scales, resolutions, spatial coverage, and accuracy. This method is based on geostatistics to represent spatial heterogeneous structures, and also on Bayesian hierarchical models to integrate multiscale, multi-type datasets in a consistent manner. We apply this method to the datasets from three years: 2014 to 2016. The temporal changes among the three integrated maps enables us to characterize the spatiotemporal dynamics of radiation air dose rates. The data-driven ecological decay model is then coupled with the integrated map to predict future dose rates. Results show that the air dose rates are decreasing consistently across the region. While slower in the forested region, the decrease is particularly significant in the town area. The decontamination has contributed to significant reduction of air dose rates. By 2026, the air dose rates will continue to decrease, and the area above 3.8 μSv/h will be almost fully contained within the non-residential forested zone.

54 ENVIRONMENTAL SCIENCES↗

Characterizing regional-scale temporal evolution of air dose rates after the Fukushima Daiichi Nuclear Power Plant accident

In this study, we quantify the temporal changes of air dose rates in the regional scale around the Fukushima Dai-ichi Nuclear Power Plant in Japan, and predict the spatial distribution of air dose rates in the future. We first apply the Bayesian geostatistical method developed by Wainwright et al. (2017) to integrate multiscale datasets including ground-based walk and car surveys, and airborne surveys, all of which have different scales, resolutions, spatial coverage, and accuracy. This method is based on geostatistics to represent spatial heterogeneous structures, and also on Bayesian hierarchical models to integrate multiscale, multi-type datasets in a consistent manner. We apply this method to the datasets from three years: 2014 to 2016. The temporal changes among the three integrated maps enables us to characterize the spatiotemporal dynamics of radiation air dose rates. The data-driven ecological decay model is then coupled with the integrated map to predict future dose rates. Results show that the air dose rates are decreasing consistently across the region. While slower in the forested region, the decrease is particularly significant in the town area. The decontamination has contributed to significant reduction of air dose rates. By 2026, the air dose rates will continue to decrease, and the area above 3.8 μSv/h will be almost fully contained within the non-residential forested zone.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nonhuman biota dose rate estimation from liquid effluent releases during normal operations of light water reactors using the LADTAP II computer code

Here, the LADTAP II computer code was used to estimate the dose rates to seven nonhuman biota (fish, algae, invertebrate, muskrat, raccoon, heron, and duck) from liquid effluent releases during the normal operations of new light water reactor facilities in the United States. The estimated dose rates to nonhuman biota depended on the nuclear power plant design but were orders of magnitude less than the ‘derived consideration reference levels’ (DCRL) in International Commission on Radiological Protection (ICRP) Publication 108. The estimated dose rates were at least three orders of magnitude lower than the guideline values identified by the International Atomic Energy Agency (IAEA) and the National Council on Radiation Protection and Measurements to cause observable changes in populations of biota. Radionuclides that contributed most of the dose rates for seven nonhuman biota depended on the nuclear power plant design. The differences in the estimated dose rates to seven nonhuman biota calculated from the default bioaccumulation factors used in the LADTAP II computer code and the dose rates calculated from the concentration ratios of radionuclides in the IAEA Technical Report Series (TRS) wildlife handbook were less than one order of magnitude for most default biota in LADTAP. The concentration ratios for some radionuclides in liquid effluent releases from nuclear power plant designs that contributed more than 5% of the internal dose rates for invertebrates (P, and Ru) and algae (La and Pr) were not available in the IAEA TRS wildlife handbook.

54 ENVIRONMENTAL SCIENCES↗

Effects of Alcohol Administered with Flibanserin in Healthy Premenopausal Women: A Randomized, Double-Blind, Single-Dose Crossover Study

Abstract Introduction Flibanserin is approved in the United States and Canada for the treatment of hypoactive sexual desire disorder in premenopausal women. Aim The purpose of this trial was to evaluate the safety of concomitant administration of flibanserin with alcohol. Methods In this single-center, randomized, double-blind, single-dose, crossover study, participants were randomly assigned to 1 of 12 sequences to receive each of 7 treatments: flibanserin 100 mg or placebo with ethanol 0.2 g/kg, 0.4 g/kg, or 0.6 g/kg, or flibanserin 100 mg only. Treatments were administered using a worst-case approach that included morning dosing and consumption of alcohol within 10 minutes. Main Outcome Measure The primary end point was the proportion of participants who experienced dizziness, syncope, or hypotension. Safety end points included orthostatic vital signs. Results The study included 96 premenopausal women (mean age 31 ± 8 years). The incidence of dizziness for ethanol + flibanserin was 39.8% for ethanol 0.6 g/kg, 34.1% for 0.4 g/kg, and 27.4% for 0.2 g/kg compared with 31.1% for flibanserin without ethanol. Based on the available vital signs data, there was no effect of ethanol concentration on orthostatic blood pressure, vertigo, or hypotension; no instances of syncope were observed. The overall incidence of adverse events (AEs) was similar when flibanserin was administered alone (96.7%) or with ethanol (90.5–97.6%). Clinical Implications Consumption of the tested amounts of alcohol (0.2–0.6 g/kg) does not have an additive effect on the AE profile of flibanserin 100 mg in healthy premenopausal women. Strengths & Limitations Strengths include the study population (premenopausal women, as indicated for flibanserin) and range of ethanol doses. Limitations include the morning dosing of study medication, which is inconsistent with the bedtime dosing recommended for flibanserin, and the method of handling missing vital sign measurements. Conclusion Co-administration of flibanserin 100 mg with varying doses of ethanol resulted in few AEs of special interest, with no notable alcohol dose response. However, a significantly greater percentage of participants administered flibanserin with 0.6 g/kg and 0.4 g/kg of alcohol were characterized as “Participants in Whom Standing Blood Pressure Was Not Obtained” compared with participants administered flibanserin alone.

Simon, James A.↗

Comparative Pharmacokinetics of High and Low Doses of the Herbicide Propanil in Mice

We have documented that the herbicide propanil is immunotoxic in mice, and our in vitro tissue culture experiments largely recapitulate the in vivo studies. Laboratory studies on environmental contaminants are the most meaningful when these studies are conducted using concentrations that approximate levels in the environment. Many techniques to measure the distribution and pharmacokinetics (PK) on compounds rely on techniques, such as liquid scintillation counting (LSC) of radio-labeled starting compound, that require concentrations higher than environmental levels. The aim of this study was to compare tissue PK after exposure to propanil concentrations more relevant to levels of exposure to agricultural workers and the general population to concentrations previously reported for laboratory studies. To this end, we conducted a study to measure propanil distribution in three immune organs, using ultrasensitive accelerator mass spectrometry (AMS). Here, we used two doses: the lower dose modeled levels expected in the environment or long-term occupational exposure to low doses, while the higher dose was to model the effects of an accidental exposure. Our results showed that the distribution and PK profiles from these two different concentrations was markedly different. The profile of the high dose (concentration) exposure was indicative of saturation of the detoxifying capability of the animal. In contrast, at the lower environmentally relevant concentration, in vivo concentrations of propanil in spleen, liver, and blood dropped to a very low level by 720 min. In conclusion, these studies highlight the differences in PK of propanil at these two doses, which suggests that the toxicity of this chemical should be re-investigated to obtain better data on toxic effects at doses relevant for humans.

59 BASIC BIOLOGICAL SCIENCES↗

Electron paramagnetic resonance dose measurements in teeth of tissue donors to the United States Transuranium and Uranium Registries

Abstract The United States Transuranium and Uranium Registries (USTUR) is a research program that studies actinide biokinetics in occupationally exposed individuals with known intakes of these elements. Electron paramagnetic resonance (EPR) in tooth enamel was applied to reconstruct external doses of nine USTUR registrants. Only in two cases there is a reasonable agreement between the EPR-measured dose and the worksite external dose record. For two registrants, high EPR doses can be explained by possible cancer radiotherapy. For the remaining five cases, EPR doses significantly exceed official occupational doses with no plausible explanation for the observed discrepancy. More EPR dose measurements need to be done to explain this anomaly.

Environmental Sciences & Ecology↗

Organ and effective dose coefficients for cranial and caudal irradiation geometries: photons

With the introduction of new recommendations of the International Commission on Radiological Protection (ICRP) in Publication 103, the methodology for determining the protection quantity, effective dose, has been modified. The modifications include changes to the defined organs and tissues, the associated tissue weighting factors, radiation weighting factors and the introduction of reference sex-specific computational phantoms. Computations of equivalent doses in organs and tissues are now performed in both the male and female phantoms and the sex-averaged values used to determine the effective dose. Dose coefficients based on the ICRP 103 recommendations were reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Publication 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT) and isotropic (ISO). In this work, the methodology of ICRP Publication 116 was used to compute dose coefficients for photon irradiation of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace from personnel standing on contaminated surfaces or volumes and from overhead sources. Calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. As with calculations reported in ICRP 116, the effects of charged-particle transport are evident when compared with values obtained by using the kerma approximation. At lower energies the effective dose per particle fluence for cranial and caudal exposures is less than AP orientations while above similar to 30 MeV the cranial and caudal values are greater.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Monoenergetic Photon Organ Dose Rate Coefficients for the Female Stylized and Voxel Phantoms Submerged in Air

Dose rate coefficients computed using the International Commission on Radiological Protection (ICRP) reference adult female voxel phantom were compared with values computed using the Oak Ridge National Laboratory (ORNL) adult female stylized phantom in an air submersion exposure geometry. This is a continuation of previous work comparing monoenergetic organ dose rate coefficients for the male adult phantoms. With both the male and female data computed, effective dose rate as defined by ICRP Publication 103 was compared for both phantoms. Organ dose rate coefficients for the female phantom and ratios of organ dose rates for the voxel and stylized phantoms are provided in the energy range from 30 to 5 MeV. Analysis of the contribution of the organs to effective dose is also provided. Lastly, comparison of effective dose rates between the voxel and stylized phantoms was within 8% at 100 keV and is <5% between 200 and 5000 keV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessment of the point-source method for estimating dose rates to members of the public from exposure to patients with 131I thyroid treatment

The U.S. Nuclear Regulatory Commission (USNRC) initiated a contract with Oak Ridge National Laboratory (ORNL) to calculate radiation dose rates to members of the public that may result from exposure to patients recently administered iodine-131 ( 131 I) as part of medical therapy. The main purpose was to compare dose rate estimates based on a point source and target with values derived from more realistic simulations that considered the time-dependent distribution of 131 I in the patient and attenuation of emitted photons by the patient’s tissues. The external dose rate estimates were derived using Monte Carlo methods and two representations of the Phantom with Movable Arms and Legs, previously developed by ORNL and the USNRC, to model the patient and a nearby member of the public. Dose rates to tissues and effective dose rates were calculated for distances ranging from 10 to 300 cm between the phantoms and compared to estimates based on the point-source method, as well as to results of previous studies that estimated exposure from 131 I patients. The point-source method overestimates dose rates to members of the public in very close proximity to an 131 I patient but is a broadly accurate method of dose rate estimation at separation distances of 300 cm or more at times closer to administration.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gamma-ray dose from an overhead plume

Standard plume models can underestimate the gamma-ray dose when most of the radioactive material is above the heads of the receptors. Typically, a model is used to calculate the air concentration at the height of the receptor, and the dose is calculated by multiplying the air concentration by a concentration-to-dose conversion factor. Models indicate that if the plume is emitted from a stack during stable atmospheric conditions, the lower edges of the plume may not reach the ground, in which case both the ground-level concentration and the dose are usually reported as zero. However, in such cases, the dose from overhead gamma-emitting radionuclides may be substantial. Such underestimates could impact decision making in emergency situations. The Monte Carlo N-Particle code, MCNP, was used to calculate the overhead shine dose and to compare with standard plume models. At long distances and during unstable atmospheric conditions, the MCNP results agree with the standard models. As a result, at short distances, where many models calculate zero, the true dose (as modeled by MCNP) can be estimated with simple equations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Oak Ridge Reservation Environmental Protection Rad Neshaps Radionuclide Inventory Web Database and Rad Neshaps Source and Dose Database

The U.S. Environmental Protection Agency promulgated national emission standards for emissions of radionuclides other than radon from US Department of Energy facilities in Chapter 40 of the Code of Federal Regulations (CFR) 61, Subpart H. This regulatory standard limits the annual effective dose that any member of the public can receive from Department of Energy facilities to 0.1 mSv. As defined in the preamble of the final rule, all of the facilities on the Oak Ridge Reservation, i.e., the Y–12 National Security Complex, Oak Ridge National Laboratory, East Tennessee Technology Park, and any other U.S. Department of Energy operations on Oak Ridge Reservation, combined, must meet the annual dose limit of 0.1 mSv. At Oak Ridge National Laboratory, there are monitored sources and numerous unmonitored sources. To maintain radiological source and inventory information for these unmonitored sources, e.g., laboratory hoods, equipment exhausts, and room exhausts not currently venting to monitored stacks on the Oak Ridge National Laboratory campus, the Environmental Protection Rad NESHAPs Inventory Web Database was developed. This database is updated annually and is used to compile emissions data for the annual Radionuclide National Emission Standards for Hazardous Air Pollutants (Rad NESHAPs) report required by 40 CFR 61.94. It also provides supporting documentation for facility compliance audits. In addition, a Rad NESHAPs source and dose database was developed to import the source and dose summary data from Clean Air Act Assessment Package—1988 computer model files. As a result, this database provides Oak Ridge Reservation and facility-specific source inventory; doses associated with each source and facility; and total doses for the Oak Ridge Reservation dose.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗